• 제목/요약/키워드: Kinematic Energy

검색결과 158건 처리시간 0.026초

Numerical study on the walking load based on inverted-pendulum model

  • Cao, Liang;Liu, Jiepeng;Zhang, Xiaolin;Chen, Y. Frank
    • Structural Engineering and Mechanics
    • /
    • 제71권3호
    • /
    • pp.245-255
    • /
    • 2019
  • In this paper, an inverted-pendulum model consisting of a point supported by spring limbs with roller feet is adopted to simulate human walking load. To establish the kinematic motion of first and second single and double support phases, the Lagrangian variation method was used. Given a set of model parameters, desired walking speed and initial states, the Newmark-${\beta}$ method was used to solve the above kinematic motion for studying the effects of roller radius, stiffness, impact angle, walking speed, and step length on the ground reaction force, energy transfer, and height of center of mass transfer. The numerical simulation results show that the inverted-pendulum model for walking is conservative as there is no change in total energy and the duration time of double support phase is 50-70% of total time. Based on the numerical analysis, a dynamic load factor ${\alpha}_{wi}$ is proposed for the traditional walking load model.

석문일월무예 음양보법의 숙련성에 따른 보행 패턴의 하지 운동학 및 운동역학적 특성 (A Study of Motor Expertise about Kinematic and Kinetic Characteristics of Lower Extremity in the Seokmun Ilwol Martial Art Yin-yang Bo Gait Pattern)

  • 박복희;김기형
    • 한국운동역학회지
    • /
    • 제24권3호
    • /
    • pp.239-248
    • /
    • 2014
  • The purpose of this study was to quantify kinematic and kinetic characteristics of Yin-yang Bo gait according to their motor expertise, one of the Seokmun Ilwol martial art gait patterns. Yin-yang Bo gait pattern shows initial forefoot contact instead of heel contact, and increased time of stance phase time, internal-external rotation of ankle-knee-hip joints and pelvic. It aims to produce and store the more energy through continuous homeostasis of center of gravity (COG) and performance of stretch-shortening cycle. Some of these characteristics also were similar to the gait modification strategies for reducing knee adduction moment such as toe-out progression, medial thrust, internal rotation of hip joint. To identify the characteristics, four factors of expert Yin-yang Bo gait performance group were compared to that of none expert group; 1) angles of COG displacement and rotation 2) distal joint pre-rotation in internal-external rotation of ankle-knee-hip joints and pelvic, 3) invariability pelvic potential and pelvic segment total energy 4) knee abduction moment. Six healthy(three male) subjects participated in the experiment to perform Yin-yang gait pattern. Three-dimensional and force plate data were collected. Kinematic and kinetic data were compared between two groups using t-tests. Results showed that 1) the peak point of COG internal rotation angle was reduced in expert group, 2) kneeexternal and hip joint -internal and pelvic rotation angle peak frames were more near points in expert group.

Centrifuge modeling of dynamically penetrating anchors in sand and clay

  • An, Xiaoyu;Wang, Fei;Liang, Chao;Liu, Run
    • Geomechanics and Engineering
    • /
    • 제30권6호
    • /
    • pp.539-549
    • /
    • 2022
  • Accidental anchor drop can cause disturbances to seabed materials and pose significant threats to the safety and serviceability of submarine structures such as pipelines. In this study, a series of anchor drop tests was carried out to investigate the penetration mechanism of a Hall anchor in sand and clay. A special anchor drop apparatus was designed to model the inflight drop of a Hall anchor. Results indicate that Coriolis acceleration was the primary cause of large horizontal offsets in sand, and earth gravity had negligible impact on the lateral movement of dropped anchors. The indued final horizontal offset was shown to increase with the elevated drop height of an anchor, and the existence of water can slow down the landing velocity of an anchor. It is also observed that water conditions had a significant effect on the influence zone caused by anchors. The vertical influence depth was over 5 m, and the influence radius was more than 3 m if the anchor had a drop height of 25 m in dry sand. In comparison, the vertical influence depth and radius reduced to less than 3 m and 2 m, respectively, when the anchor was released from 10 m height and fell into the seabed with a water depth of 15 m. It is also found that the dynamically penetrating anchors could significantly influence the earth pressure in clay. There is a non-linear increase in the measured penetration depth with kinematic energy, and the resulted maximum earth pressure increased dramatically with an increase in kinematic energy. Results from centrifuge model tests in this study provide useful insights into the penetration mechanism of a dropped anchor, which provides valuable data for design and planning of future submarine structures.

다물체 동역학을 이용한 파력발전기의 동적거동 분석 (Dynamic Analysis of Wave Energy Generation System by Using Multibody Dynamics)

  • 장진석;손정현
    • 대한기계학회논문집A
    • /
    • 제35권12호
    • /
    • pp.1579-1584
    • /
    • 2011
  • 본 논문에서는 파도의 에너지를 전기에너지로 변환하는 파력발전시스템에 대해 다루며, 발전기 및 12개의 암을 가진 가동물체형 파력발전기를 기구학적 구속조건을 이용하여 다물체 동역학 모델링 하였다. 새롭게 제안하는 파력발전기의 기어 메커니즘과 구속방정식 및 전달되는 힘요소에 대해 동역학적으로 모델링하였다. 파력은 시간영역에서 모리슨 방정식을 이용하여 수치적으로 계산하여 모델에 적용하였다. 시스템 거동해석을 위해 상용 다물체동역학 해석프로그램인 MSC/ADAMS를 이용하였다. 파력발전시스템의 파도에 대한 안정성을 검토하고 동적 거동 특성을 분석하였다. 하중에 따라 거동 특성을 분석한 결과 Yaw 운동은 상대적으로 적게 나타났으며 파고 1 m 이상일 경우 충분한 운동에너지가 발생함을 알 수 있다.

A FINITE-VISCOELASTIC CONTINUUM MODEL FOR RUBBER AND ITS FINITE ELEMENT ANALYSIS

  • Kim, Seung-Jo;Kim, Kyeong-Su;Cho, Jin-Yeon
    • Journal of Theoretical and Applied Mechanics
    • /
    • 제1권1호
    • /
    • pp.97-109
    • /
    • 1995
  • In this paper, a finite viscoelastic continuum model for rubber and its finite element analysis are presented. This finite viscoelatic model based on continuum mechanics is an extended model of Johnson and Wuigley's 1-D model. In this extended model, continuum based kinematic measures are rigorously defied and by using this kinematic measures, elastic stage law and flow rule are introduced. In kinematics, three configuration are introduced. In kinematics, three configuration are introduced. They are reference, current and virtual visco configurations. In elastic state law, it is assumed that at a certain time, there exists an elastic potential which describes the recoverable elastic energy. From this elastic potential, elastic state law is derived. The proposed flow rule is based on phenomenological observation. The flow rule gives precise relaxation response. In finite element approximation, mixed Lagrangian description is used, where total and similar method of updated Lagrangian descriptions are used together. This approach reduces the numerical job and gives simple nonlinear syatem of equations. To satisfy the incompressible condition, penalty-type modified Mooney-Rivlin energy function is adopted. By this method nearly incompressible condition is obtain the virtual visco configuration. For verification, uniaxial stretch tests are simulated for various stretch rates. The simulated results show good agreement with experiments. As a practical experiments. As a preactical example, pressurized rubber plate is simulated. The result shows finite viscoelastic effects clearly.

에너지보행과 일반보행의 운동학적 비교 (The Kinematic Comparison of Energy Walking and Normal Walking)

  • 신제민;진영완
    • 한국운동역학회지
    • /
    • 제16권4호
    • /
    • pp.61-71
    • /
    • 2006
  • The purpose of this study was to compare kinematic characteristics on the limbs at 3 different walking speed during the energy and the normal walking. Eight subjects performed energy walking and normal walking at the slow speed(65 beats/min), the normal speed(115beats/min), the fast speed(160 beats/min). The 3-d angle was calculated by vector projected with least squares solution with three-dimensional cinematography(Motion Analysis corporation). The range of motion was calculated on the trunk, shoulder, elbow, hip, knee joint. The results showed that stride length was no difference of the two walking pattern. The duration of support phase was also no difference of the two walking pattern. The range of motion of shoulder joint significantly increased in the sagittal and frontal planes, and the range of motion of elbow joint significantly increased as the energy walking. The range of motion of hip joint had no significant difference in the any planes in changing of walking speed. But the most remarkable difference of the two walking patterns revealed at the trunk. The range of flexion/extension angle had significant increasing $2.36^{\circ}$ at normal speed, and the range of the right/left flexion angle had significant increasing below $4^{\circ}$ at the 3 walking speed, and The range of rotation angle had significant increasing $7.35^{\circ}$, $9.22^{\circ}$, respectively at the normal and slow speed. But there was no significant difference of range of motion at the hip and knee joints between energy walking and normal walking.

디젤차량의 주행거리에 따른 DPF 윤활유의 특성분석에 관한 실험적 연구 (Experimental Study on the DPF Engine Oil Characteristics Depending on a Mileage of Diesel Automotive)

  • 김청균
    • Tribology and Lubricants
    • /
    • 제25권5호
    • /
    • pp.318-323
    • /
    • 2009
  • The oil characteristics and wear particles of Diesel engines with a DPF have been investigated as a function of a driving distance. The engine oil of SAE 5W30 with ACEA C3 is used for an oil film lubrication of the engine, which is equipped with Diesel particulate filter. Depending on the oil test results, the kinematic viscosity of used engine oils at 40 is degraded up to 5.1% compared with that of unused engine oils, SAE 5W30. And the kinematic viscosity of used engine oils at 100 is more degraded up to 8.1% compared with that of unused engine oils. The oil characteristic as a function of a mileage is not changed depending on the driving distance because of high quality of engine oils. But the aluminum and copper compounds, which are used as base materials of the engine bearing and a pin bush, are much worn and contaminated for the increased mileage of the car. The oil properties of used engine oils are relatively good except phosphorus and calcium additives, which are heavily engaged in the performance of the oils.

파워워킹과 일반보행의 운동학적 및 EMG 비교분석 (The Comparative Analysis of Kinematic And Emg on Power Walking and Normal Gait)

  • 조규권;김유신;김은정
    • 한국운동역학회지
    • /
    • 제16권2호
    • /
    • pp.85-95
    • /
    • 2006
  • The purpose of this study of which 10 University students in their twenties are the objects was to examine the causal differences of kinematic and electromyography during power walking and normal gait. We came to the following conclusions. 1) It took less time to stance phase, swing phase and whole gait time during power walking compared with normal gait. 2) During power walking, the step length and step length and lower limb length are longer than that of normal gait. 3) During power walking, ankle joint angle became more plantar flexed at LIC and RTO, knee joint angle become more flexed, so did hip joint angle at LIC and RTO. Besides during power walking the shoulder joint angle movement was bigger and elbow joint angle was more flexed as the trait of power walking. 4) During power walking, through out the phase the muscle activity of all muscle was higher expecially the muscle activity of Biceps brachii, gastrocnemius medialis, gastrocnemius lateralis, Soleus was higher. Therefore during power walking, one's scope of activity and muscle activity is relatively higher than those of normal gait, so power walking helps one strengthen muscular power and energy metabolism. This will be useful information for those who are interested in diet and well-being.

모션 캡쳐에 기반한 도마뱀 속보에 대한 기구학적 모델링 (Kinematic Modelling of the Trot of a Lizard Based on the Motion Capture)

  • 김창회;신호철;이흥호
    • 전자공학회논문지
    • /
    • 제50권8호
    • /
    • pp.264-273
    • /
    • 2013
  • 미래의 전쟁에서 인명 피해를 최소화하기 위한 방안으로 로봇의 중요성이 부각되고 있으며 최적으로 진화된 생물체를 모방하는 생체모방로봇에 대한 연구가 활발하게 추진되고 있다. 도마뱀 모방형 로봇은 협소한 지역에서 은밀한 접근 및 은닉을 필요로 하는 정찰 및 감시 등의 임무를 수행하기에 적합하다. 본 논문에서는 적외선 마커를 이용하여 도마뱀의 보행동작을 분석하였다. 쿠반 에놀의 관절 부위에 21 개의 마커를 부착하고 광학적 모션 캡쳐 장비를 사용하여 도마뱀의 보행 동작을 측정하였다. 측정된 데이터를 분석하여 펼친 자세로 속보로 보행하는 도마뱀의 걸음 동작을 분석하였다. 또한 도마뱀의 걸음새를 충실하게 구현 가능하도록 25 자유도를 갖는 기구학 모델을 제안하였으며 시뮬레이션을 통하여 모델링의 타당성을 확인하였다.

고정식 진동수주형 파력발전기에 관한 실험적 연구 (A Study for Fixed Type Wave Energy Conversion Device with Oscillating Water Column)

  • 김성근;박노식;박인규
    • 한국해양공학회지
    • /
    • 제10권2호
    • /
    • pp.136-145
    • /
    • 1996
  • The theory is based on two thermodynamic equations for the air mass in the air column and bydrodynamic equation for the relation between the response of the air in the water column and the incident wave. The numerical model is experimented in a two dimensional water tank and the caisson model with sloped front wall is tested in the large towing tank.

  • PDF