• 제목/요약/키워드: Kinematic Data

검색결과 711건 처리시간 0.039초

The test-retest reliability of gait kinematic data measured using a portable gait analysis system in healthy adults

  • An, Jung-Ae;Byun, Kyung-Seok;Lee, Byounghee
    • 대한물리치료과학회지
    • /
    • 제27권3호
    • /
    • pp.25-34
    • /
    • 2020
  • Background: Gait analysis is an important measurement for health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to investigate the reliability of the newly developed portable gait analysis system (PGAS). Design: Cross-sectional design. Test-retest study. Methods: The PGAS study was based on a wearable sensor, and measurement of gait kinematic parameters, such as gait velocity, cadence, step length and stride length, and joint angle (hip, knee, and ankle) in stance and swing phases. The results were compared with a motion capture system (MCS). Twenty healthy individuals were applied to the MCS and PGAS simultaneously during gait performance. Results: The test-retest reliability of the PGAS showed good repeatability in gait parameters with mean intra-class correlation coefficients (ICCs) ranging from 0.840 to 0.992, and joint angles in stance and swing phase from 0.907 to 0.988. The acceptable test-retest ICC was observed for the gait parameters (0.809 to 0.961), and joint angles (0.800 to 0.977). Conclusion: The results of this study indicated that the developed PGAS showed good grades of repeatability for gait kinematic data along with acceptable ICCs compared with the results from the MCS. The gait kinematic parameters in healthy subjects can be used as standard values for adopting this PGAS.

압연강판의 이방성에 관한 연구 (Study of anisoptopy of sheet metals)

  • 인정제
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 춘계학술대회논문집
    • /
    • pp.153.1-156
    • /
    • 1999
  • Based upon the experimental data from multi-stage tensile loading at angles to the rolling direction of steel sheets, anisotropic hardening rules are proposed. Experiments show that orthotropic anisotropy is maintained and the orientations of orthotropy axes are changed during tensile loading. A phenomenological model is proposed which includes the rotations of orthotropy axes, work hardening and kinematic hardening. Using the model, uniaxial tensile stress, R-value and tensile necking strain are predicted and compared with the experimental data.

  • PDF

이동경화 모델에 기반한 MS1470 강판의 스프링백 예측 (Spring-back Prediction of MS1470 Steel Sheets Based on a Non-linear Kinematic Hardening Model)

  • 박상천;박태준;고영우;석동윤;;;정관수
    • 소성∙가공
    • /
    • 제22권6호
    • /
    • pp.303-309
    • /
    • 2013
  • Spring-back of MS1470 steel sheets was numerically predicted using a non-linear kinematic hardening material behavior based on the Yoshida-Uemori model. From uniaxial tension and uniaxial tension-compression-tension data as well as the uniaxial tension-unloading-tension data, the parameters of the Yoshida-Uemori model were obtained. For the numerical simulations, the Yoshida-Uemori model was implemented into the commercial finite element program, ABAQUS/Explicit and ABAQUS/Standard using the user-defined material subroutines. The model performance was validated against the measured spring-back from the benchmark problems of NUMISHEET 2008 and NUMISHEET 2011, the 2-D draw bending test and the S-rail forming test, respectively.

DEVELOPMENT OF VEHICLE DYNAMICS MODEL FOR REAL-TIME ELECTRONIC CONTROL UNIT EVALUATION SYSTEM USING KINEMATIC AND COMPLIANCE TEST DATA

  • KIM S. S.;JUNG H. K.;SHIM J. S.;KIM C. W.
    • International Journal of Automotive Technology
    • /
    • 제6권6호
    • /
    • pp.599-604
    • /
    • 2005
  • A functional suspension model is proposed as a kinematic describing function of the suspension, that represents the relative wheel displacement in polynomial form in terms of the vertical displacement of the wheel center and steering rack displacement. The relative velocity and acceleration of the wheel is represented in terms of first and second derivatives of the kinematic describing function. The system equations of motion for the full vehicle dynamic model are systematically derived by using velocity transformation method of multi-body dynamics. The comparison of test and simulation results demonstrates the validity of the proposed functional suspension modeling method. The model is computationally very efficient to achieve real-time simulation on TMS 320C6711 150 MHz DSP board of HILS (hardware-in-the-loop simulation) system for ECU (electronic control unit) evaluation of semi-active suspension.

레이저-비전 센서를 이용한 Autonomous Robot Kinematic Calibration (Autonomous Robot Kinematic Calibration using a Laser-Vision Sensor)

  • 정정우;강희준
    • 한국정밀공학회지
    • /
    • 제16권2호통권95호
    • /
    • pp.176-182
    • /
    • 1999
  • This paper presents a new autonomous kinematic calibration technique by using a laser-vision sensor called "Perceptron TriCam Contour". Because the sensor measures by capturing the image of a projected laser line on the surface of the object, we set up a long, straight line of a very fine string inside the robot workspace, and then allow the sensor mounted on a robot to measure the point intersection of the line of string and the projected laser line. The point data collected by changing robot configuration and sensor measuring are constrained to on a single straght line such that the closed-loop calibration method can be applied. The obtained calibration method is simple and accurate and also suitable for on-site calibration in an industrial environment. The method is implemented using Hyundai VORG-35 for its effectiveness.

  • PDF

경직의 정량 평가를 위한 진자실험의 변수분석 (A Study on the Parameter Analysis for the Quantitative Evaluation of Spasticity Implementing Pendulum Test)

  • 임현균;이영신;조강희;채진목;김봉옥
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.268-273
    • /
    • 2000
  • Velocity-dependent increase in tonic stretch reflexes is one of the prominent characteristics of spasticity. It is very important to evaluate spasticity objectively and quantitatively before and after treatment for physicians. An accurate quantitative biomechanical evaluation for the spasticity which is caused by the disorder of central nervous system is made in this study. A sudden leg dropper which is designed to generate objective testing environment at every trial gives very effective environment for the test. Kinematic data are archived by the 3-dimensional motion analysis system($Elite^{(R)}$, B.T.S., Italy). Kinematic data are angle and angular velocity of lower limb joints, and length and lengthening velocity of lower limb muscle. A program is also developed to analyze the kinematic data of lower limb, contraction and relaxation length of muscles, and dynamic EMG data at the same tim. To evaluate spasticity quantitatively, total 31 parameters extracted from goniogram, EMG and muscle model are analyzed. Statistical analysis are made for bilateral correlations for all parameters. The described instrumentation and parameters to make quantitative and objective evaluation of spasticity shows good results.

  • PDF

Development of the Kinematic Global Positioning System Precise Point Positioning Method Using 3-Pass Filter

  • Choi, Byung-Kyu;Roh, Kyoung-Min;Cho, Sung-Ki;Park, Jong-Uk;Park, Pil-Ho;Lee, Sang-Jeong
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권3호
    • /
    • pp.269-274
    • /
    • 2012
  • Kinematic global positioning system precise point positioning (GPS PPP) technology is widely used to the several area such as monitoring of crustal movement and precise orbit determination (POD) using the dual-frequency GPS observations. In this study we developed a kinematic PPP technology and applied 3-pass (forward/backward/forward) filter for the stabilization of the initial state of the parameters to be estimated. For verification of results, we obtained GPS data sets from six international GPS reference stations (ALGO, AMC2, BJFS, GRAZ, IENG and TSKB) and processed in daily basis by using the developed software. As a result, the mean position errors by kinematic PPP showed 0.51 cm in the east-west direction, 0.31 cm in the north-south direction and 1.02 cm in the up-down direction. The root mean square values produced from them were 1.59 cm for the east-west component, 1.26 cm for the south-west component and 2.95 cm for the up-down component.

프로골퍼의 4m 퍼팅시 퍼터 헤드형태에 따른 운동학적 특성 (Kinematic Characteristics according to Types of Putter Head on Pro Golfer's 4 Meter Putts)

  • 이근혁;소재무
    • 한국운동역학회지
    • /
    • 제23권4호
    • /
    • pp.319-326
    • /
    • 2013
  • The objective of this study is to help golfers to select adequate putters and to provide golfers basic scientific data for improving athletic performance by showing differences of kinematic variables according to the shape of putter head. In this research three right-handed male pro-golfer who are listed at KPGA were studied and three video camera (GR-HD1KR, JVC, Japan) were used and recording speed was 60 frame/sec during the research. In this study kinematic variables were calculated using Kwon3D XP program and analysed on the 4 events and 3 phases. This study showed the following results : (1) The swing of heel-toe putter showed longer time than that of face balanced putter, and there are statistical significant difference of kinematic variables of each objective (2) As of the trajectory of putter head, heel-toe putter showed more approximating curve trajectory than that of in-between, face balanced putter on the X-axis (3) heel-toe putter showed longer distance follow-through than that of other putters by statistically significant difference on the Y-axis (4) Heel-toe putter showed longer distance swing trajectory over the ground than that of other putters by statistically significant difference on the Z-axis.

Relationship between the Impact Peak Force and Lower Extremity Kinematics during Treadmill Running

  • Ryu, Ji-Seon;Park, Sang-Kyoon
    • 한국운동역학회지
    • /
    • 제28권3호
    • /
    • pp.159-164
    • /
    • 2018
  • Objective: The aims of this study were to determine the impact peak force and kinematic variables in running speed and investigate the relationship between them. Method: Thirty-nine male heel strike runners ($mean\;age=21.7{\pm}1.6y$, $mean\;mass=72.5{\pm}8.7kg$, $mean\;height=176.6{\pm}6.1cm$) were recruited in this investigation. The impact peak forces during treadmill running were assessed, and the kinematic variables were computed using three-dimensional data collected using eight infrared cameras (Oqus 300, Qualisys, Sweden). One-way analysis of variance ANOVAwas used to investigate the influence of the running speed on the parameters, and Pearson's partial correlation was used to investigate the relationship between the impact peak force and kinematic variables. Results: The running speed affected the impact peak force, stride length, stride frequency, and kinematic variables during the stride phase and the foot angle at heel contact; however, it did not affect the ankle and knee joint angles in the sagittal plane at heel contact. No significant correlation was noted between the impact peak force and kinematic variables in constantrunning speed. Conclusion: Increasing ankle and knee joint angles at heel contact may not be related to the mechanism behind reducing the impact peak force during treadmill running at constant speed.

만성요통환자의 보행특성에 관한 연구 (A Study on the Characteristics of Gait in Patients with Chronic Low Back Pain)

  • 김경;고주연;이성용
    • The Journal of Korean Physical Therapy
    • /
    • 제21권2호
    • /
    • pp.79-85
    • /
    • 2009
  • Purpose: This study examined the characteristics of gait in patients with chronic low back pain. Methods: The subjects were out-patients suffering from chronic low back pain at the department of physical therapy, B hospital in Seoul. Gait analysis was performed by dividing the subjects into two groups. The study and control group comprised 15 chronic low back pain patients and 14 healthy people, respectively. Gait analysis was performed using a VICON 512 Motion Analysis System to obtain the spatio-temporal and kinematic parameters. Results: First, there was a significant difference in the spatio-temporal parameters between the two groups (p<0.05). Second, the study group showed significant differences in the kinematic parameters during the stance phase (p<0.05). Third, there were significant differences in kinematic parameters in the study group during the swing phase (p<0.05). Conclusion: The gait pattern of patients with chronic low back pain is characterized by more rigid patterns. Compared to the control group, there was a decrease in the spatio-temporal parameters and kinematic parameters in patients with chronic low back pain. These findings are expected to play a role as basic data and to form a rehabilitation program for low back pain patients.

  • PDF