• Title/Summary/Keyword: Kim So-hee

Search Result 6,124, Processing Time 0.039 seconds

FPGA Design and SoC Implementation of Constant-Amplitude Multicode Bi-Orthogonal Modulation (정진폭 다중 부호 이진 직교 변복조기의 FPGA 설계 및 SoC 구현)

  • Hong, Dae-Ki;Kim, Yong-Seong;Kim, Sun-Hee;Cho, Jin-Woong;Kang, Sung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.11C
    • /
    • pp.1102-1110
    • /
    • 2007
  • In this paper, we design the FPGA (Field-Programmable Gate Array) of the CAMB (Constant-Amplitude Multi-code Biorthogonal) modulation, and implement the SoC (System on Chip). The ASIC (Application Specific Integrated Circuit) chip is be implemented through targeting and board test. This 12Mbps modem SoC includes the ARM (Advanced RISC Machine)7TDMI, 64Kbyte SRAM(Static Random Access Memory) and ADC (Analog to Digital Converter)/DAC (Digital to Analog Converter) for flexible applications. Additionally, the modem SoC can support the variable communication interfaces such as the 16-bits PCMCIA (Personal Computer Memory Card International Association), USB (Universal Serial Bus) 1.1, and 16C550 Compatible UART (Universal Asynchronous Receiver/Transmitter).

FGPA Design and SoC Implementation for Wireless PAN Applications (무선 PAN 응용을 위한 FPGA 설계 및 SoC)

  • Kim, Young-Sung;Kim, Sun-Hee;Hong, Dae-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.462-469
    • /
    • 2008
  • In this paper, we design the FPGA (Field-Programmable Gate Array) of the KOINONIA WPAN (Wireless Personal Area Network), and implement the SoC (System on Chip). We use the redundant bits to make a constant-amplitude in a modulator part. Additionally, the SNR (Signal to Noise Ratio) performance of the demodulator is improved by using the redundant bits in decoding steps. The four-million FPGA of the KOINONIA WPAN can be operated at 44MHz frequency. The PER (Packet Error Rate) of the designed FPGA with RF (Radio Frequency) module is below 1% at the -86dB MIPLS (Minimum Input Power Level Sensitivity), and the SNR is about 13dB. The SoC is implemented by using Hynix 0.25um CMOS (Complementary Metal Oxide Semiconductor) process. The size of the SoC is $6.52mm{\times}6.92mm$.

A Personalized Recommendation Procedure for E-Commerce

  • Kim, Jae-Kyeong;Cho, Yoon-Ho;Kim, Woo-Ju;Kim, Je-Ran;Suh, Ji-Hae
    • Proceedings of the Korea Inteligent Information System Society Conference
    • /
    • 2001.01a
    • /
    • pp.192-197
    • /
    • 2001
  • A recommendation system tracks past actions of a group of users to make a recommendation to individual members of the group. The computer-mediated marketing and commerce have grown rapidly nowadays so the concerns about various recommendation procedures are increasing. We introduce a recommendation methodology by which e-commerce sites suggest new products of services to their customers. The suggested methodology is based on web log analysis, product taxonomy, and association rule mining. A product recommendation system is developed based on our suggested methodology and applied to a Korean internet shopping mall. The validity of our recommendation system is discussed with the analysis of a real internet shopping mall case.

  • PDF

Camera for Quasars in Early Universe

  • Park, Won-Kee;Pak, Soojong;Im, Myungshin;Choi, Changsu;Jeon, Yiseul;Chang, Seunghyuk;Jeong, Hyeonju;Lim, Juhee;Kim, Eunbin;Choi, Nahyun;Lee, Hye-In;Kim, Sanghyuk;Jeong, Byeongjoon;Ji, Taegeun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.68.2-68.2
    • /
    • 2013
  • Camera for QUasars in EArly uNiverse (CQUEAN) is an optical CCD camera system made by Center for Exploration of the Origin of the Universe (CEOU). CQUEAN is developed for follow-up observation of red sources such as high-redshift quasar candidates ($z{\geq}5$), gamma-ray bursts (GRB), brown dwarfs and young stellar objects. The CQUEAN is composed of a science camera with deep-depletion CCD chip which is sensitive at around $1{\mu}m$, a set of custom-made wide-band filters for detection of quasar candidates at z~5, and a guide camera. A focal reducer was developed to secure $4.8^{\prime}{\times}4.8^{\prime}$ field of view, and an in-house user software for efficient data acquisition. CQUEAN was attached to 2.1m Otto Struve Telescope in McDonald Observatory, USA, in August 2010. About 1000 quasar candidates including 3 confirmed with follow-up spectroscopy, have been observed so far, and many high-z galaxy cluster candidates, GRBs and supernovae were also observed. And monitoring of HBC 722, a young stellar object, is under way since 2011. Further enhancement of CQUEAN including the introduction of narrow-band filters is planned.

  • PDF

Comparison Characteristic on Psychological Status between Genuine and Pseudo Halitosis (진성구취 및 가성구취 환자군의 심리적 특성차이에 대한 연구)

  • Jang, Seung-Won;Kim, Jin-Sung;Kang, Kyung;Kim, Ju-Yeon;Son, Ji-Yeong;Baek, Seung-Hwan;Choi, Jane;Ryu, Bong-Ha
    • The Journal of Internal Korean Medicine
    • /
    • v.34 no.4
    • /
    • pp.405-411
    • /
    • 2013
  • Objectives : This study was designed to investigate the difference between genuine and pseudo halitosis about qi stagnation and stress. Methods : We recruited 63 halitosis patients who visited the halitosis clinic in the Kyung Hee University Korean Medicine Hospital from June 2012 to August 2013. We classified the halitosis patients into two groups, genuine and pseudo halitosis based on organoleptic assesment (OLT) score and evaluated the severity of self-reported halitosis using visual analog scale (VAS), amount of sulfide compounds using Halimeter, qi stagnation level using qi stagnation questionnaire and stress levels using heart rate variability (HRV) parameters. Results : Comparing the genuine halitosis group and the pseudo halitosis group, there was no significant difference in VAS of halitosis but significant difference in halimeter score. Distribution of qi stagnation and non-qi stagnation groups was significantly different between genuine and pseudo halitosis. Compared to the genuine halitosis group, the pseudo halitosis group showed a significant higher value of low frequency/high frequency ratio (LF/HF ratio). Conclusions : The result of this study suggest that there is significant difference about qi stagnation and stress level between genuine halitosis and pseudo halitosis patients, so when approaching pseudo halitosis patients, we should consider their psychological and emotional status.

An Hardware Error Analysis of 3D Automatic Face Recognition Apparatus(3D-AFRA) : Surface Reconstruction (3차원 안면자동인식기(3D-AFRA)의 Hardware 정밀도 검사 : 형상복원 오차분석)

  • Seok, Jae-Hwa;Song, Jung-Hoon;Kim, Hyun-Jin;Yoo, Jung-Hee;Kwak, Chang-Kyu;Lee, Jun-Hee;Kho, Byung-Hee;Kim, Jong-Won;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.2
    • /
    • pp.30-39
    • /
    • 2007
  • 1. Objectives The Face is an important standard for the classification of Sasang Constitution. We are developing 3D Automatic Face Recognition Apparatus(3D-AFRA) to analyse the facial characteristics. This apparatus show us 3D image and data of man's face and measure facial figure data. So we should examine the figure restoration error of 3D Automatic Fare Recognition Apparatus(3D-AFRA) in hardware Error Analysis. 2. Methods We scanned Face status by using 3D Automatic Face Recognition Apparatus(3D-AFRA). And also we scanned Face status by using laser scanner(vivid 9i). We compared facial shape data be restored by 3D Automatic Face Recognition Apparatus(3D-AFRA) with facial shape data that be restorated by 3D laser scanner. And we analysed the average error and the maximum error of two data. 3. Results and Conclusions In frontal face, the average error was 0.48mm. and the maximum error was 4.60mm. In whole face, the average error of was 0.99mm. And the maximum error was 6.64mm. In conclusion, We assessed that accuracy of 3D Automatic Face Recognition Apparatus(3D-AFRA) is considerably good.

  • PDF

Comparison of the Clinical Characteristics of Patients with Gastroesophageal Reflux Disease According to Globus Sensation (인후부 이물감 호소에 따른 위식도역류질환 환자의 임상적 특징 비교)

  • Baek, So-young;Hwang, Mi-ni;Ko, Whee-hyoung;Kim, Dong-yoon;Lee, Ha-nul;Jeong, Hae-in;Ha, Na-yeon;Kim, Jin-sung
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.3
    • /
    • pp.287-294
    • /
    • 2019
  • Objectives: This study aimed to investigate the clinical characteristics of patients with gastroesophageal reflux disease (GERD) according to globus sensation (GS). Methods: We reviewed the clinical records of 29 GERD patients who visited the Department of Digestive Diseases of Kyung Hee University Korean Medicine Hospital from March 1, 2018 to February 28, 2019. The subjects were classified according to the presence of globus sensation, and the two groups were compared in terms of heart rate variability (HRV) and the Ryodoraku results. Results: In comparing the GERD with GS group (GS group) and the GERD without GS group (non-GS group), a significant difference was found in the duration of symptom and several HRV parameters. The duration of the symptom in the GS group was significantly longer than that in the non-GS group. The non-GS group showed a significantly higher value of total power and high frequency than the GS group. Conclusions: The results suggest a significant difference in the stress level between patients with GERD with GS and those without GS. When approaching patients with GERD without GS, their stress status should be considered.