• Title/Summary/Keyword: Kim Jeong-hee

Search Result 10,204, Processing Time 0.061 seconds

Standard Performance Measurements of GE $Advance^{TM}$ Positron Emission Tomography (GE $Advance^{TM}$ 양전자방출단층촬영기의 표준 성능평가)

  • Jeong, Ha-Kyu;Kim, Hee-Joung;Son, Hye-Kyung;Bong, Jung-Kyun;Jung, Hai-Jo;Jeon, Tae-Joo;Kim, Jae-Sam;Lee, Jong-Doo;Yoo, Hyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.2
    • /
    • pp.100-112
    • /
    • 2001
  • Purpose: The purpose of this study was to establish optimal imaging acquisition conditions for the GE $Advance^{TM}$ PET imaging system by performing the acceptance tests designed by National Electrical Manufacturers Association (NEMA) protocol and General Electric Medical Systems (GEMS) test procedures. Materials and Methods: Performance tests were carried out with $^{18}FDG$ radioactivity source and phantoms by using a standard acquisition mode. Transaxial resolution and scatter traction tests were performed with a line source and axial resolution with a point source, respectively. A cylindrical phantom made of polymethylmethacrylate (PMMA) was used to measure sensitivity, count rate losses and randoms, uniformity correction, and attenuation inserts were added to measure remaining tests. The test results were acquired in a diagnostic acquisition mode and analyzed mainly on high sensitivity mode. Results: Transaxial resolution and axial resolution were measured as average of 4.65 mm and 3.98 mm at 0 cm, and 6.02 mm and 6.71 mm at 20 cm on high sensitivity mode, respectively. Average scatter fraction was 9.87%, and sensitivity was $225.8kcps/{\mu}Ci/cc$ of trues. Activity at 50% deadtime was $4.6{\mu}Ci/cc$, and the error of count rate correction at that activity was from 1.49% to 3.83%. Average nonuniformity for total slice w3s 8.37%. The accuracy of scatter correction was -0.95%. The accuracies of attenuation correction were 5.68% for air, 0.04% for water and -6.51% for polytetrafluoroethylene (PTFE). Conclusion: The results satisfied most acceptance criteria, indicating that the GE $Advance^{TM}$ PET system can be optimally used for clinical applications.

  • PDF

Relationship between Pathogenic Vibrios and Zooplankton Biomass in Coastal Area, Korea (병원성 비브리오균과 동물성 플랑크톤과의 관계에 관한 연구)

  • CHANG Dong-Suck;KIM Chang-Hoon;YU Hong-Sik;KIM Shin-Hee;JEONG Eun-Tak;SHIN Il-Shik
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.5
    • /
    • pp.557-566
    • /
    • 1996
  • An ecological study on pathogenic vibrios was done in the aquatic environments of southern coast of Korea during summer in 1995, to investigate the distribution and relationship between pathogenic vibrio and zooplankton. Furthermore, special emphasis was given to study on the efforts of zooplankton existence on the wintering of Vibrio cholerae in the aquatic region in Korea. During the study period, pathogenic vibrios were isolated from the samples such as V. parahaemolyticus, V. vulnificus, V. mimicus, and V. cholerae non O1, but V. cholerae O1 was not detected in any sample submitted in this study. Adsorption ratio of V. parahaemolyticus onto zooplankton was higher than that of E. coli. The efficiency of adsorption was found to be on the concentration of NaCl and other ions found in sea water. For example, adsorption ratio of V. parahaemolyticus were $75\%\;at\;5\%_{\circ}$ of NaCl solution and $55\%$ at same salinity of diluted sea water, but those were decreased as $20\%\;and\;7\%\;at\;15\%_{\circ}$ salinity of NaCl solution and diluted sea water, respectively. In addition, survival period of pathogenic vibrio was extended in the presence of live copepods at $25^{\circ}C$, but zooplankton existence has no significant effect on the survival rate at $5^{\circ}C$ in closed microcosm and also microalgae and dead copepods do not affect on the survival of V. parahaemolyticus. According to these experimental results, zooplankton has positive effects on the growth and survival rate of pathogenic vibrios in sea water during the summer season, but copepods have no significant effects on the growth and survival rate of them in winter season in Korea. Finally, authors suggest that V. cholerae is not able to over winter with zooplankton in adjacent sea water in Korea.

  • PDF

Physicochemical Characteristics of Sikhye (Korean Traditional Rice Beverage) with Specialty Rice Varieties (특수미 품종에 따른 식혜의 이화학적 특성)

  • Kim, Kee-Jong;Woo, Koan-Sik;Lee, Jin-Seok;Chun, A-Reum;Choi, Yoon-Hee;Song, Jin;Suh, Sae-Jung;Kim, Sun-Lim;Jeong, Heon-Sang
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.11
    • /
    • pp.1523-1528
    • /
    • 2008
  • This study was carried out to compare the physicochemical characteristics and sensory quality of Sikhye (a Korean traditional rice beverage) prepared with specialty rice varieties. The results showed that Ilpum had higher hulling recovery, milled/brown rice ratio, and milling recovery than Sulgaeng, Baegjinju, Baegjinju 1, and Dongjinchal. The alkali digestive value, protein content, and amylose contents of Sulgaeng were 6.3, 7.3% and 19.3%, respectively. The highest brix degree was $10.00^{\circ}Bx$ in Baegjinju Sikhye. The turbidity appeared at 0.4440, 0.4100, 0.3828, 0.3372, 0.1414 in Ilpum, Baegjinju, Baegjinju 1, Sulgaeng, and Dongjinchal Sikhye, respectively. There were no significant differences in pH and maltose contents among the groups. The highest L-value was 44.62 in Ilpum Sikhye. The a-value and b-value were $-1.66{\sim}-0.70$ and $-9.18{\sim}-5.19$, respectively. Finally, the sensory evaluation results indicated that there were no significant differences in appearance, aroma, and taste between the groups, and the Sulgaeng Sikhye showed higher overall quality than the Dongjinchal Sikhye as the control.

Ferucarbotran-Enhanced Hepatic MRI at 3T Unit: Quantitative and Qualitative Comparison of Fast Breath-hold Imaging Sequences (간의 3T 자기공명영상에서 초상자성산화철 조영증강 급속호흡정지영상기법들간의 양적 및 질적 비교평가)

  • Cho, Kyung-Eun;Yu, Jeong-Sik;Chung, Jae-Joon;Kim, Joo-Hee;Kim, Ki-Whang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.31-40
    • /
    • 2010
  • Purpose : To compare the relative values of various fast breath-hold imaging sequences for superparamagnetic iron-oxide (SPIO)-enhanced hepatic MRI for the assessment of solid focal lesions with a 3T MRI unit. Materials and Methods : 102 consecutive patients with one or more solid malignant hepatic lesions were evaluated by spoiled gradient echo (GRE) sequences with three different echo times (2.4 msec [GRE_2.4], 5.8 msec [GRE_5.8], and 10 msec [GRE_10]) for $T2^*$-weighted imaging in addition to T2-weighted turbo spin echo (TSE) sequence following intravenous SPIO injection. Image qualities of the hepatic contour, vascular landmarks and artifacts were rated by two independent readers using a four-point scale. For quantitative analysis, contrast-to-noise ratio (CNR) was measured in 170 solid focal lesions larger than 1 cm (107 hepatocellular carcinomas, nine cholangiocarcinomas and 54 metastases). Results : GRE_5.8 showed the highest mean points for hepatic contour, vascular anatomy and imaging artifact presence among all of the subjected sequences (p<0.001) and was comparable (p=0.414) with GRE_10 with regard to lesion conspicuity. The mean CNRs were significantly higher (p<0.001) in the following order: GRE_10 ($24.4{\pm}14.5$), GRE_5.8 ($14.8{\pm}9.4$), TSE ($9.7{\pm}6.3$), and GRE_2.4 ($7.9{\pm}6.4$). The mean CNRs of CCCs and metastases were higher than those of HCCs for all imaging sequences (p<0.05). Conclusion : Regarding overall performances, GRE using a moderate echo time of 5.8 msec can provide the most reliable data among the various fast breath-hold SPIO-enhanced hepatic MRI sequences at 3T unit despite the lower CNR of GRE_5.8 compared to that of GRE_10.

Real-Time PCR for Quantitative Detection of Bovine Herpesvirus Type 1 (Bovine Herpesvirus Type 1 정량 검출을 위한 Real-Time PCR)

  • Lee, Dong-Hyuck;Jeong, Hyo-Sun;Lee, Jung-Hee;Kim, Tae-Eun;Lee, Jung-Suk;Kim, In-Seop
    • Korean Journal of Microbiology
    • /
    • v.44 no.1
    • /
    • pp.14-21
    • /
    • 2008
  • Bovine blood, cell, tissue, and organ are used as raw materials for manufacturing biopharmaceuticals, tissue engineered products, and cell therapy. Manufacturing processes for the biologicals using bovine materials have the risk of viral contamination. Therefore viral validation is, essential in ensuring the safety of the products. Bovine herpesvirus type 1 (BHV-1) is the most common bovine pathogen found in bovine blood, cell, tissue, and organ. In order to establish the validation system for the BHV-1 safety of the products, a real-time PCR method was developed for quantitative detection of BHV-1 in raw materials, manufacturing processes, and final products as well as BHV-1 clearance validation. Specific primers for amplification of BHV-1 DNA was selected, and BHV-1 DNA was quantified by use of SYBR Green I. The sensitivity of the assay was calculated to be $2\;TCID_{50}/ml$. The real-time PCR method was validated to be reproducible and very specific to BHV-1. The established real-time PCR assay was successfully applied to the validation of Chinese hamster ovary (CHO) cell artificially infected with BHV-1. BHV-1 DNA could be quantified in CHO cell as well as culture supernatant. Also the real-time PCR assay could detect $10\;TCID_{50}/ml$ of BHV-1 artificially contaminated in bovine collagen. The overall results indicated that this rapid, specific, sensitive, and robust assay can be reliably used for quantitative detection of BHV-1 contamination during the manufacture of biologics.

Aided Distance Visual Acuity and Refractive Error Changes by Using Smartphone (스마트폰 사용이 원거리 교정시력과 굴절 이상 변화에 미치는 영향)

  • Kim, Bong-Hwan;Han, Sun-Hee;Shin, Young Gul;Kim, Da Yeong;Park, Jin Young;Sin, Won Chul;Yoon, Jeong Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.305-309
    • /
    • 2012
  • Purpose:This study was conducted to research any effect on aided distance visual acuity and refractive error changes by using smartphone at near for long term. Methods: 20($20.6{\pm}0.9$ years) young adults subjects with no ocular diseases, over 0.8 of aided distance visual acuity, normal amplitude of accommodation and normal accommodative facility agreed to participate in this study. The subjects were divided into two group, Group 1 (15 cm fixation distance) included 10 subjects and Group 2(40 cm fixation distance) included 10 subjects. Aided distance visual acuity and refractive error were measured before and after using smartphone for 30 minutes by auto-chart project (CP-1000, Dongyang, Korea), phoropter (VT-20, Dongyang, Korea), auto refractor-keratometer (MRK-3100, Huvitz, Korea). After then, the subjects looked at distance with wearing spectacles. Refractive error was measured at 5 minutes, 10 minutes, and 15 minutes later, respectively. Results: After using smartphone at 15 cm for 30 minutes, there was statistically significant reduction of aided distance visual acuity (p=0.030) and increasing myopia (p=0.001). The increased myopia was not statistically significant after 5 minutes rest (p${\geq}$0.464). However there was no statistically significant changes in aided distance visual acuity (p=0.163) and refractive error (p=0.077) after using smartphone at 40 cm for 30 minutes. Conclusions: It is recommend to keep 40 cm off the smartphone from eyes to avoid any aided distance visual acuity and refractive error changes. If smartphone is used closer than 40 cm, a rest for 5 minutes is also recommend after every 30 minutes use with smartphone to avoid any aided distance visual acuity and refractive error changes.

Comparison of total body irradiation-based or non-total body irradiation-based conditioning regimens for allogeneic stem cell transplantation in pediatric leukemia patients (소아 백혈병 환자의 동종 조혈모세포이식 전처치로서 전신방사선 조사 포함군과 비포함군의 비교)

  • Kim, Sang-Jeong;Han, Dong-Kyun;Baek, Hee-Jo;Kim, Dong-Yeon;Nam, Taek-Keun;Hwang, Tai-Ju;Kook, Hoon
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.4
    • /
    • pp.538-547
    • /
    • 2010
  • Purpose : This study aims to compare the outcome of total body irradiation (TBI)- or non-TBI-containing conditioning regimens for leukemia in children. Methods : We retrospectively evaluated 77 children conditioned with TBI (n=40) or non-TBI (n=37) regimens, transplanted at Chonnam National University Hospital between January 1996 and December 2007. The type of transplantation, disease status at the time of transplant, conditioning regimen, engraftment kinetics, development of graft-versus-host disease (GVHD), complications, cause of deaths, overall survival (OS), and event-free survival (EFS) were compared between the 2 groups. Results : Among 34 patients with acute lymphoblastic leukemia (ALL), 28 (82.4%) were in the TBI group, while 72.7% (24/33) of patients with myeloid leukemia were in the non-TBI group. Although the 5-year EFS of the 2 groups was similar for all patients (62% vs 63%), the TBI group showed a better 5-year EFS than the non-TBI group when only ALL patients were analyzed (65% vs 17%; $P$=0.005). In acute myelogenous leukemia patients, the non-TBI group had better survival tendency (73% vs 38%; $P$=0.089). The incidence of GVHD, engraftment, survival, cause of death, and late complications was not different between the 2 groups. Conclusion : The TBI and non-TBI groups showed comparable results, but the TBI group showed a significantly higher 5-year EFS than the non-TBI group in ALL patients. Further prospective, randomized controlled studies involving larger number of patients are needed to assess the late-onset complications and to compare the socioeconomic quality of life.

A Comparative Study Concerning the Psychopathologies between the Patients with Peptic Ulcer and Those with Essential Hypertension - Focused on Medically-Ill Out Patients - (소화성 궤양과 본태성 고혈압 환자의 정신병리에 관한 비교 연구 - 내과외래환자를 중심으로 -)

  • Choi, Hyun-Kyoung;Kim, Chan-Woo;Lee, Dong-Gun;Kwak, Chung-Whan;Park, Seung-Ken;Park, Hee-Ouk;Ok, Jong-Whan;Kim, Jeong-Gee
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.11 no.2
    • /
    • pp.149-158
    • /
    • 2003
  • Objectives: The authors studied the anxiety, depression and psychological characteristics of medical out-patients, which are diagnosed as peptic ulcer disorder and essential hypertension. We also examined the state of psychiatric consultation. Methods: The subjects were composed of 56 patients with peptic ulcer disorder, 44 patients with essential hypertension and 116 controls. STAI, BDI and SCL-90R was administered to all subjects. Chart review, telephone interview and Self report questionnaire of etiology and severity of illness, drug compliance and so forth were performed in disease groups. Results: Considerable depression was noticed in 39.3% among the patients with peptic ulcer disorder, 27.7% in hypertension and 12.1% in control group by BDI. State anxiety was noticed in 44.6% among the patients with peptic ulcer disorder, 54.5% in hypertension and 18.1% in control group by State anxiety. Trait anxiety was noticed in 42.9% among the patients with peptic ulcer disorder, 34.1% in hypertension and 25.8% in control group by Trait anxiety. The higher SOM, BDI, STAI, the lower drug compliance and rapport. Psychological problems are considered of the most important etiology in 48.2% of peptic ulcer group and 45.7% of hypertensive group. But psychiatric consultation is made only in 1.8% of peptic ulcer group and 2.3% of hypertensive group. Conclusions: Anxiety and depression are common phenomena in medical outpatients. In comparison with the normal control group, peptic ulcer group showed significantly higher trait anxiety and depression and hypertensive group higher state anxiety. These characteristics are related to the drug compliance and doctor-patient relationship. These results suggested the needs of active psychiatric consultation.

  • PDF

Effect of Pre-Germination by Treatment of Soaking on Germination of Soybean (콩의 발아 전 침종처리가 발아에 미치는 영향)

  • Cho, Seong-Woo;Kim, Tae-Sun;Kwon, Soo-Jeong;Roy, Swapan Kumar;Lee, Chul-Won;Kim, Hong-Sig;Woo, Sun-Hee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.60 no.1
    • /
    • pp.123-137
    • /
    • 2015
  • This study was carried out to investigate the effect of pre-germination soaking on germination in 90 Korean soybean varieties and identification of protein in seeds of 7 soybean varieties. The results obtained that germination rate of soybean seeds was decreased as amount of soaking water and soaking duration in number of days. Difference in germination rate of soybean seeds was significant at three days soaking with water volume of 90 ml. Water absorption of seeds was rapidly increased during the first 6 hours, followed by slow increase until 24 hours and then decreased 24 to 48 hours after soaking soybean varieties for bean sprout soaked the lowest amount of water, while soybean varieties for cooking with rice showed the lowest seed water content. Dissolved oxygen (DO) in soaking water was rapidly decreased during the first 3 hours after soaking, and then slowly decreased. Soybean varieties for vegetable and early maturity showed the lowest DO during early soaking periods, but showed higher DO after 24 hours than other groups of soybean varieties. Electrical conductivity and Total Dissolved Solid (TDS) were increased as number of soaking days increased. Soybean varieties for vegetable and early maturity showed the highest electrical conductivity and TDS, followed by those for sauce and paste or cooking with rice, while showed the lowest electrical conductivity and TDS, varieties for bean sprout. Among 90 Korean soybean varieties, varieties which showed the highest germination rate were Jangsu-kong for sauce and paste, Sobaegnamul-kong for bean sprout, Seonheuk-kong for cooking with rice, Seunnokkong for vegetable and early maturity. On the ather hand varieties which showed the lowest germination rate were Iksan and Songhak-kong for sauce and paste, Pangsa-kong for bean sprout, Jinyeul-kong for cooking with rice, Sinlok-kong for vegetable and early maturity. Germination rates of soybean seeds were higher when electrical conductivity, TDS and water absorption of seeds were lower. There were negative correlations between electrical conductivity, TDS and water absorption of seeds and germination rate, while there were positive correlations among electrical conductivity, TDS and soybean seed weight.

Comparison of defect size measured by transthoracic and transesophageal echocardiography with balloon occlusive diameter measured during transcatheter closure of atrial septal defect (경피적 심방중격결손 폐쇄술 시 경흉부 및 경식도 초음파 검사 상의 결손의 크기와 풍선 폐쇄 직경과의 관계)

  • Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.10
    • /
    • pp.970-975
    • /
    • 2007
  • Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.