• Title/Summary/Keyword: Key Comparison

Search Result 1,358, Processing Time 0.029 seconds

International Comparison of high resistance and Mutual Recognition between National Metrology Institutes (전기저항의 국제비교 및 계측기술에 관한 국제적 상호인정 추세)

  • Yu, Kwang-Min;Ryu, Je-Cheon;Kang, Jeon-Hong;Kim, Han-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.606-608
    • /
    • 1999
  • Mutual Recognition Agreement(MRA) between national metrology institutes is started on October 1999 and International Key Comparison is essentially to be used as technical basis for the agreement. High resistance is one of the Key Comparison and high resistance measurement system is established in KRISS for the purpose of the Key Comparison. Total combined uncertainty of the system is about 4ppm in $10M{\Omega}$ and 8ppm in $1G{\Omega}$. With the system, the difference of comparison results for $10M{\Omega}$ and $1G{\Omega}$ among KRISS, VNIIM in Russia and NIM in China is agreed about 6ppm within total combined uncertainty of three institutes.

  • PDF

Measurement of triple point of water temperature for improvement of the national standards and key comparison (국가표준향상과 핵심국제비교를 위한 물의 삼중점 온도 측정)

  • Yang, Inseok;Lee, Young Hee
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.349-356
    • /
    • 2021
  • The Korea Research Institute of Standards and Science (KRISS), a National Metrology Institute of Korea, participated in the second-round of the international key comparison CCT-K7.2021 of triple point of water (TPW) cells. For the key comparison, three TPW cells, one of which had been used in the old CCT-K7 comparison, were assigned as the national standard of the TPW. The temperature difference (ΔT) between the average of the new and old national standards and ΔT between the new national standard and the transfer standard were measured. The comparison between the new and old national standards indicated a temperature increase of 69.5 µK after both the standards were corrected for the isotopic composition. The uncertainty of the national standard of the TPW temperature was 28 µK, and the uncertainty of ΔT was 14 µK. Three aspects of improvements in the new comparison compared to the old one were noted: (1) inclusion of two quartz cells in the national standard strengthens its long-term stability; (2) the standard deviation associated with the measurement of ΔT was reduced from 21 µK to 9.6 µK; (3) and the measured immersion profile of the TPW cells was much closer to the theoretically predicted dependence.

Implementation of a Video Retrieval System Using Annotation and Comparison Area Learning of Key-Frames (키 프레임의 주석과 비교 영역 학습을 이용한 비디오 검색 시스템의 구현)

  • Lee Keun-Wang;Kim Hee-Sook;Lee Jong-Hee
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.2
    • /
    • pp.269-278
    • /
    • 2005
  • In order to process video data effectively, it is required that the content information of video data is loaded in database and semantics-based retrieval method can be available for various queries of users. In this paper, we propose a video retrieval system which support semantics retrieval of various users for massive video data by user's keywords and comparison area learning based on automatic agent. By user's fundamental query and selection of image for key frame that extracted from query, the agent gives the detail shape for annotation of extracted key frame. Also, key frame selected by user becomes a query image and searches the most similar key frame through color histogram comparison and comparison area learning method that proposed. From experiment, the designed and implemented system showed high precision ratio in performance assessment more than 93 percents.

  • PDF

Results of Key Comparison on LS1P Microphones (LS1P 마이크로폰 핵심측정표준 국제비교 결과)

  • Suh Jae Gap;Jho Moon Jae;Kwon Hyu-Sang;Suh Sang Joon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.194-201
    • /
    • 2005
  • Since the necessity for the accurate measurement in the field of acoustics, vibration, and ultrasound was internationally increased, CCAUV (Consultative Committee for Acoustics , Ultrasound and Vibration) was created by the CIPM (International Committee for Weights and Measures) in 1998. One of the first activities of CCAUV is the key comparison on 1' standard microphones. The key comparison was done from April. 1999 to April. 2001 and 12 NMIs(National Metrology Institutes) including KRISS (Korea Research Institute of Standards and Science) were participated. The pilot laboratory was the National Physical Laboratory(NPL). The traveling standards were two LSIP(Laboratory Standard 1' Pressure Type) microphones specified in IEC 61094-1 and the calibration frequency ranges covers from 63Hz to 8kHz. In this paper, the analyzed results in the final report were summarized.

esearch Trend Analysis Focused on Thesis Key Words: in the Fields of Korean Language and Literature, Korean Language Education, and Korean Language Education as a Foreign Language (학위논문 주제어 중심 연구동향 분석 -국어국문학, 국어교육학, 한국어교육학 분야를 중심으로-)

  • Kim, Eunsil;Kang, Seunghae
    • Journal of Korean language education
    • /
    • v.29 no.2
    • /
    • pp.25-48
    • /
    • 2018
  • The aim of this study was to analyze research trends in the fields of Korean Language and Literature, Korean Language Education, and Korean Language Education as a Foreign Language. To this end, key words were extracted from 29,470 academic theses published between 2000 and 2017. The results of the analysis are as follows. First, in the field of Korean Language and Literature, there is greater quantity in studies about Korean language than about literature, and starting from 2010, there was an increase in studies similar to those from the field of Korean Language Education as a Foreign Language. Next, in comparison to the other fields, the field of Korean Language Education has greater variance in its research theme-in particular, numerous studies related to the site of education. Finally, the field of Korean Language Education has the following trends: a) there are copious studies focused on Korean language learners in comparison to other fields, b) there are a greater number of studies focused on culture, and c) the key words change by time period which suggest that research demands transformed over time. Overall, a total of 64 highest frequency key words from the three academic fields were investigated. Of these, 22 were common key words and 42 were differential key words. In this way, it was possible to illuminate the identity of each field.

Construction and Comparison Measurement of Triple Point Water Cells for using Key Comparison and Evaluation of Uncertainty (핵심국제비교용 물의 삼중점 셀 제작과 비교 실험 및 불확도 평가)

  • Kang, Kee-Hoon;Kim, Yong-Gyoo;Gam, Kee-Sool
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.114-120
    • /
    • 2004
  • The $Comet{\acute{e}}$ Consultatif de $Thermom{\acute{e}}trie$ (CCT) under the Comete International des Poids et Measures (CIPM) has decided to perform the Key Comparison (KC) for triple point of water cells used as a reference fixed point of thermometry at the 21st meeting held at November 2001, and the Bureau International des Poids et Measures (BIPM) has been nominated as a KC coordinator. According to the KC protocol prepared by BIPM, KRISS performed the KC experiments and evaluate a uncertainty. The temperature difference between two reference cells for the Korea Research Institute of Standards and Science (KRISS) and a test cell for the transfer standard, which is moved to BIPM was 0.024 mK and the combined standard uncertainty evaluated 0.055 mK.

A Quantitative Evaluation and Comparison of Harmonic Elimination Algorithms Based on Moving Average Filter and Delayed Signal Cancellation in Phase Synchronization Applications

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.717-730
    • /
    • 2016
  • The harmonic components of grid voltage result in oscillations of the calculated phase obtained via phase synchronization. This affects the security and stability of grid-connected converters. Moving average filter, delayed signal cancellation and their related harmonic elimination algorithms are major methods for such issues. However, all of the existing methods have their limitations in dealing with multiple harmonics issues. Furthermore, few studies have focused on a comparison and evaluation of these algorithms to achieve optimal algorithm selections in specific applications. In this paper, these algorithms are quantitatively analyzed based on the derived mathematical models. Moreover, an enhanced moving average filter and enhanced delayed signal cancellation algorithms, which are applicable for eliminating a group of selective harmonics with only one calculation block, are proposed. On this basis, both a comprehensive comparison and a quantitative evaluation of all of the aforementioned algorithms are made from several aspects, including response speed, required data storage size, sensitivity to sampling frequency, and elimination of random noise and harmonics. With the conclusions derived in this paper, better overall performance in terms of harmonic elimination can be achieved. In addition, experimental results under different conditions demonstrate the validity of this study.

Construction of AC-DC Magnetic Field Standard Systems and Results of International Key Comparison (직류-교류 자기장 표준 시스템 제작 및 국제비교 결과)

  • Park, Po-Gyu;Kim, Young-Gyun
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.6
    • /
    • pp.201-206
    • /
    • 2004
  • The AC-DC magnetic field standard systems were constructed for the calibration of magnetometers for low magnetic field and the tests for low magnetic field characteristics of sensors and materials. In the range of 1 mT, the expanded uncertainty of dc is 8${\times}$10$\^$-6/, ac uncertainties are 0.16% in 0.1~1 kHz, 0.26% in 1~5 kHz, and 0.44% in 5~20 kHz. We have been participated in international key comparison(KC) to achieve the equality and the mutual agreement between standard institutes for the results of calibrations and tests. KRISS participating in ac-dc magnetic flux density of KC got equal level of uncertainty results compare with the advanced nations. It confirm that measurement ability of magnetic flux density is high level in the world.

Modeling and Analysis of Leakage Currents in PWM-VSI-Fed PMSM Drives for Air-Conditioners with High Accuracy and within a Wide Frequency Range

  • Sun, Kai;Lu, Yangjun;Xing, Yan;Huang, Lipei
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.970-981
    • /
    • 2016
  • Leakage currents occur in pulse-width-modulated voltage source inverter (PWM-VSI)-fed permanent magnet synchronous motor (PMSM) drives for air-conditioners, which seriously affect system safety and operation performance. High accuracy modeling and prediction of leakage currents are key issues for the design and implementation of air-conditioning products. In this study, the generation mechanism of leakage currents is discussed. A systematic modeling approach of leakage currents is proposed, including the modeling of leakage current sources and leakage current paths. By using the proposed approach, the complete model of leakage currents in PWM-VSI-fed PMSM drives for air-conditioners has been developed based on the extraction of all parameters. A comparison between the simulated leakage currents based on the developed model and measured leakage currents in the outdoor unit of an air-conditioning product is conducted. The comparison verifies the effectiveness of the proposed modeling approach, and the developed model exhibits high accuracy within a wide frequency range.

Secret Key Generation Using Reciprocity in Ultra-wideband Outdoor Wireless Channels

  • Huang, Jing Jing;Jiang, Ting
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.2
    • /
    • pp.524-539
    • /
    • 2014
  • To investigate schemes of secret key generation from Ultra-wideband (UWB) channel, we study a statistical characterization of UWB outdoor channel for a campus playground scenario based on extensive measurements. Moreover, an efficient secret key generation mechanism exploiting multipath relative delay is developed, and verification of this algorithm is conducted in UWB Line-of-sight (LOS) outdoor channels. For the first time, we compare key-mismatch probability of UWB indoor and outdoor environments. Simulation results demonstrate that the number of multipath proportionally affects key generation rate and key-mismatch probability. In comparison to the conventional method using received signal strength (RSS) as a common random source, our mechanism achieves better performance in terms of common secret bit generation. Simultaneously, security analysis indicates that the proposed scheme can still guarantee security even in the sparse outdoor physical environment free of many reflectors.