• 제목/요약/키워드: Kerma

검색결과 84건 처리시간 0.024초

심장 전기생리학 검사 시 조건 변화에 따른 환자 피폭 선량 평가 (Evaluation of Patient Exposure Dose during Cardiac Electrophysiology Study under Various Conditions)

  • 고성빈;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.501-508
    • /
    • 2023
  • This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42 cm, 37 cm, and 31 cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.

MIRD 인형팬텀의 넓고 평행한 감마선빔에 대한 선량 환산계수 계산 (Calculation of Dose Conversion Coefficients in the Anthropomorphic MIRD Phantom in Broad Unidirectional Beams of Monoenergetic Photons)

  • 장재권;이재기
    • Journal of Radiation Protection and Research
    • /
    • 제22권1호
    • /
    • pp.47-58
    • /
    • 1997
  • MCNP4A 코드를 이용하여 MIRD 인형팬텀의 정면과 후방에서 입사하는 넓고 평행한 감마선빔에 대한 단위 공기커마당 유효선량 환산계수와 단위 플르언스당 장기의 등가선량을 계산하였다. 본 연구에서 고려한 감마선은 0.03-10 MeV 에너지 구간에서 20개의 단일에너지에 대해 수행되었다. 환산계수의 계산결과를 ICRP/ICRU의 연구결과 발표예정 출판물에 주어진 해당되는 값과 비교한 결과 편차 10%이내에서 일치하고 있다. 결과의 차이가 발생한 이유는 MIRD 팬텀과 ADAM/EVE 팬텀의 기하학적 차이가 주원인이며 또한 계산에 사용된 전산코드와 단면적 차이 등으로 판단된다. 특정 식도 모델을 사용한 결과로부터 얻어진 유효선량과 흉선과 췌장에 대한 등가선량을 채택함으로써 얻어지는 유효선량은 약간(최고 5%)의 차이를 보인다. 기타장기로부터 상부대장을 제외했을 때 본 연구에서 다루었던 감마선 선량학적 측면의 경우에서는 중요하지 않은 것으로 나타났다.

  • PDF

물 흡수선량 표준에 기반한 선량교정 프로그램 개발 (Development of a Dose Calibration Program Based on an Absorbed Dose-to-Water Standard)

  • 신동오;김성훈;박성용;서원섭;이창건;최진호;전하정;안희경;강진오
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.175-183
    • /
    • 2003
  • 최근 선량측정의 정확성을 향상시키기 위하여 기존의 공기커마 교정인수에 기반한 표준측정법에서 물 흡수선량 교정인수에 기반한 표준측정법으로 변환하고 있는 추세이다. 본 연구에서는 미국의학물리학회의 AAPM TG-51과 국제원자력기구의 IAEA TRS-398 표준측정법에 대한 선량교정 프로그램을 개발하였다. 이 프로그램은 윈도우 환경에서 사용이 용이하도록 비쥬얼 C++언어를 사용하여 각각의 표준측정법에서 권고하고 있는 방법 및 절차에 따라 사용자의 편의성을 고려하여 개발하였다. 이 프로그램은 이온함에 대한 정보와 물리적인 자료에 대한 표와 그래프 값들을 수식화하여 데이터베이스화함으로써 수작업으로 인해 발생할 수 있는 실수 및 오차를 줄일 수 있다. 개발된 프로그램의 활용을 통하여 국내 실정에 적합한 물 흡수선량 표준에 기반한 표준측정법 개발에 토대를 마련하는데 있어 기여할 것으로 사료된다.

  • PDF

한국원자력연구소에서 개발한 Ir-192 선원의 감마메드 치료기 호환성 연구 (Study on the Compatibility for an Ir-192 Source Manufactured by Korea Atomic Energy Research Institute (KAERI) in GammaMed Brachytherapy Machine)

  • 정동혁;이강규;김수곤;문성록
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.78-85
    • /
    • 2010
  • 본 연구에서는 한국원자력연구소에서 제작한 Ir-192 밀봉선원(IRRS20, KAERI, Korea)을 감마메드 근접치료기에 장착하고 치료기와의 호환성을 조사하였다. 기계적 호환성의 평가로서 선원의 이동간격, 채널별 이동간격, 와이어의 최소 곡률 반경, 비상시 작동을 검사하였다. 약 45일 동안 수회에 걸쳐 기준 거리에서 공기커마세기를 측정하였으며, 필름을 사용하여 기존의 선원과 선량분포를 비교하였다. KAERI 선원의 감마메드 장비와의 기계적호환성은 양호하였다. 시간에 따른 방사능 특성도 계산과 잘 일치하였으며, 선원주변의 선량분포에 있어서 기존 선원과 큰 차이를 보이지 않았다.

한국원자력연구소 기준 광자 및 베타선장 측정의 국제상호비교 (Intercomparison of the KAERI Reference Photon and Beta Radiation Measurements)

  • 장시영;김봉환;김장렬
    • Journal of Radiation Protection and Research
    • /
    • 제21권4호
    • /
    • pp.255-262
    • /
    • 1996
  • 이 논문은 최근 한국원자력연구소(KAERI)와 미국 패시픽노스웨스트 국립연구소(일명, 바텔연구소, PNNL)이 개인선량계의 성능검사를 위한 미국 ANSI N13.11 기준에 근거하여 KAERI 방사선 측정/교정실험실에서 수행한 KAERI 기준 광자 및 베타 방사선장의 국제 상호비교 측정결과를 설명하고 있다. 두 기관이 각각 자국의 일차 표준에 소급성을 갖는 방사선 검출기와 방사선 측정장치를 사용하여 자유공기중에서 광자의 조사선량(율), 공기커마(율)와 베타선의 절대 흡수선량(율)을 측정한 결과, 광자선장에 대해서는 ${\pm}2.0%$을 베타선장에 대해서는${\pm}1.0%$의 오차범위 내에서 잘 일치하였다. 따라서 KAERI의 기준 광자 및 베타 방사선장은 국제표준에 잘 만족되고 있음이 입증되었으며 장차 방사선 도시메트리 연구개발의 국가 기술기반으로 활용될 수 있음이 확인되었다

  • PDF

자궁경부암의 강내치료를 위한 선량측정 (Dose Distribution&Calibration in HDR Intracavitary Irradiation for Uterine Cervical Cancer)

  • 김진기;김정수;김형진;권형철
    • 한국의학물리학회지:의학물리
    • /
    • 제6권1호
    • /
    • pp.13-18
    • /
    • 1995
  • 고선량의 RALS(Remote Afterloding Syetem)를 이용한 근접조사에서 선원의 위치에 따라 선량분포는 거리제곱의 반비례 형태로 변화되므로, 관심점의 흡수선량은 선원의 교정에 의해 크게 영향을 받는다. 자궁경부암 강내치료시 정확한 흡수선량을 결정하고자 선원을 교정하고, 선원의 위치에 따른 선량분포도에 의한 계산값과 반도체 검출기와 전리함을 이용한 설측값과 차이를 비교하고 보정 방법을 논의 하였다. Bulcher-RALS를 이용하여 치료에 사용된 선원의 교정은 공기커마와 사각형 아크랄 팬톰을 이용하여 r 인자에 의한 거리 역자승법칙으로 계산하였고, Co-60 선원의 8cm 거리에서 검교정된 측정기를 이용한 선량율을 비교치로 이용하였다. 선량측정치의 재현성은 팬톰내에서 0.3~1.1% 였으며, 측정치의 분포는 Bulcher-RALS 선량분포도에 의한 계산값과 팬톰측정치의 비교에서 -3~17%, 강내치료를 받은 18 명의 환자를 대상으로한 직장내 흡수선량에서 체내 실측값과 차이는 환자와 선원의 위치에 따라 -6~+21%로 측정값이 평균 6.3% 높게 나타났다.

  • PDF

Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구 (A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index)

  • 김재인;이양섭;장동수;정민철;배승호;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

유방촬영용 X선 진단장치에서 IEC 60601-2-45 표준규격을 적용한 직선성 평가 (Evaluation of Linearity Air Kerma Applied to the IEC 60601-2-45 Standard in Mammographic X-ray)

  • 홍동희;정홍량;임청환;한범희;한상현;이상호;모은희;김기정;이미화;유인규
    • 디지털융복합연구
    • /
    • 제12권3호
    • /
    • pp.339-344
    • /
    • 2014
  • 현재 우리나라 유방촬영장치의 정도관리 항목에는 국제규격에서 원하는 직선성이 빠져있다. 직선성은 방사선량 및 방사선질의 조정을 위한 요구사항이다. 본 연구에서는 유방촬영장치 5대를 대상으로 IEC 60601-2-45 규격에 맞는 직선성을 시험한 결과 모두 적합한 결과를 보였으며 앞으로 좀 더 발전된 정도관리를 위해서는 지속적인 측정관리가 필요하다.

A Study of Radiation Doses to the Patient and Medical Team at Embolization Procedures

  • Castilho, Alvaro Vilas Boas;Szjenfeld, Denis;Nalli, Darcio;Fornazari, Vinicius;Moreira, Antonio Carlos;Medeiros, Regina Bitelli
    • Journal of Radiation Protection and Research
    • /
    • 제44권3호
    • /
    • pp.110-117
    • /
    • 2019
  • Background: This study aimed to estimate occupational doses and patient peak skin doses (PSDs) during interventional radiology procedures. Materials and Methods: We examined data from brain embolization (n = 30), hepatic chemoembolization (n = 50), and uterine embolization (n = 12). The PSDs were measured using radiochromic film around the patient's head (group 1) or abdominal/pelvic region (group 2). Acquisition technical data and kerma-area products (KAP) were also recorded. Occupational doses were measured using $Instadose^{TM}$ dosimeters near the left eye region (LER), chest, and left ankle. Results and Discussion: The third quartile (median) KAP values were $408.1(235.3)Gy{\cdot}cm^2$ for group 1 and $584.4(449.4)Gy{\cdot}cm^2$ for group 2. The average PSDs were greatest during vascular procedures, reaching 1,004.4 (786.4) mGy, and the highest PSD was 2,352.6 mGy (during hepatic chemoembolization). The third quartile (median) occupational doses were 0.35 (0.21) mSv at the LER, 0.25 (0.15) mSv at the chest, and 1.47 (0.64) mSv at the left ankle. Occupational doses at the LER were higher than at the chest, which highlights the importance of protective glasses and suspended shields. The occupational doses at the ankle region were also high, which highlights the importance of using a lead-lined curtain attached to the table. Conclusion: The results indicate that physicians can reach, for eye region, the weekly occupational dose limit after around 15 procedures, even when using proper protection. The average PSD values were below the threshold for tissue reactions, although the complexity of these procedures emphasises the importance of considering related risks.

Proposed Institutional Diagnostic Reference Levels in Computed and Direct Digital Radiography Examinations in Two Teaching Hospitals

  • Emmanuel Gyan;George Amoako;Stephen Inkoom;Christiana Subaar;Barry Rahman Maamah
    • Journal of Radiation Protection and Research
    • /
    • 제48권1호
    • /
    • pp.9-14
    • /
    • 2023
  • Background: The detectors of both computed radiography (CR) and direct digital radiography (DR) have a wide dynamic range that could tolerate high values of exposure factors without an adverse effect on image quality. Therefore, this study aims to assess patient radiation dose and proposes institutional diagnostic reference levels (DRLs) for two teaching hospitals in Ghana. Materials and Methods: CR and DR systems were utilized in this study from two teaching hospitals. The CR system was manufactured by Philips Medical Systems DMC GmbH, while the DR system was manufactured by General Electric. The entrance skin doses (ESDs) were calculated using the standard equation and the tube output measurements. Free-in-air kerma (µGy) was measured using a calibrated radiation dosimeter. The proposed institutional DRLs were estimated using 75th percentiles values of the estimated ESDs for nine radiographic projections. Results and Discussion: The calculated DRLs were 0.4, 1.6, 3.4, 0.5, 0.4, 1.1, 1.0, 1.2, and 1.7 mGy for chest posteroanterior (PA), lumbar spine anteroposterior (AP), lumbar spine lateral (LAT), cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively in CR system. In the DR system, the values were 0.3, 1.6, 3.1, 0.4, 0.3, 0.7, 0.6, 0.9, and 1.3 for chest PA, lumbar spine AP, lumbar spine LAT, cervical spine AP, cervical spine LAT, skull PA, pelvis AP, and abdomen AP, respectively. Conclusion: Institutional DRLs in nine radiographic projections have been proposed for two teaching hospitals in Ghana for the first time. The proposed DRLs will serve as baseline data for establishing local DRLs in the hospitals and will be a valuable tool in optimizing patient doses.