• 제목/요약/키워드: Kaolin surface contamination

검색결과 10건 처리시간 0.033초

여러 환경조건에 대한 고분자애자의 누설전류 특성 변화 (Variation in Leakage Current Characteristics of Polymer Insulator for Various Environmental Condition)

  • 박재준;최인혁;이동일
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.169-175
    • /
    • 2006
  • This study investigated variation leakage current maximum value and waveform considering applied voltage phase angel by simulating three environmental conditions, such as fog, salt fog, and kaolin contamination .As the result of applied voltage phase angel characteristics, leakage currents presented almost in phases in the early stage regardless of environmental conditions just after applying the voltage, and the phase of leakage currents certain phase lags for the discharge of the applied voltage when surface discharges occurred due to the continuous environmental contamination. In addition, the difference in phase significantly increased according to the intensity of discharges. The change in distortion rates according to the environmental contamination presented a nearly same level just after applying the voltage. The distortion rate of third harmonic for the fundamental wave presented by the order of fog>salt fog>kaolin when surface discharges occurred due to the applied voltage for certain continued periods. In the case of the fog and salt fog, the scale of spectrums decreased according to the increase in frequencies from the results of the analysis of high frequencies. In addition, the even number frequency presented a relatively large level compared to the odd number frequency under the kaolin contamination.

HF-CT센서를 이용한 고분자애자의 오손특성 (Contamination Characteristics of Polymer Insulator using High Frequency Current Transformer)

  • 박재준
    • 정보학연구
    • /
    • 제8권4호
    • /
    • pp.1-7
    • /
    • 2005
  • Investigations of high frequency current transformer(HF-CT) waveform characteristics of the surface leakage on kaolin polluted EPDM polymer insulators have been performed. This work is part of a program aimed at examining the potential for HF-CT waveform characteristics analysis to provide information about the environment contaminants and environment condition of polymer insulators. The investigation reported examined the HF-CT waveform characteristics at high frequencies. The use of high frequency measurements for on-line applications reduces electrical inference. This work was peformed utilizing HF-CT to monitor of surface polluted discharge. It was found that HF-CT waveform frequency spectrum, magnitude depend on importantly the duration of the surface discharge activity.

  • PDF

방사전자파를 이용한 고분자애자의 오손량 분류기법 (Classification Technique of Kaolin Contaminants Degree for Polymer Insulator using Electromagnetic Wave)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.162-168
    • /
    • 2006
  • Recently, diagnosis techniques have been investigated to detect a Partial Discharge associated with a dielectric material defect in a high voltage electrical apparatus, However, the properties of detection technique of Partial Discharge aren't completely understood because the physical process of Partial Discharge. Therefore, this paper analyzes the process on surface discharge of polymer insulator using wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time~frequency domain. As it is important to develop a non-contact method for detecting the kaolin contamination degree, this research analyzes the electromagnetic waves emitted from Partial Discharge using wavelet transform. This result experimentally shows the process of Partial Discharge as a two-dimensional distribution in the time-frequency domain. Feature extraction parameter namely, maximum and average of wavelet coefficients values, wavelet coefficients value at the point of $95\%$ in a histogram and number of maximum wavelet coefficient have used electromagnetic wave signals as input signals in the preprocessing process of neural networks in order to identify kaolin contamination rates. As result, root sum square error was produced by the test with a learning of neural networks obtained 0.00828.

열화된 고분자애자의 카올린 오손에따른 표면방전특성 (Characteristics Leakage Current of Surface Discharge according to Kaolin Contamination by Deteriorated Polymer Insulators)

  • 박재준;가평현;서의원;정명연;김희동;송일근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1100-1103
    • /
    • 2004
  • The paper presents the results of using the fundamental and the low frequency harmonic components of leakage current to study aging of EPDM insulator for contaminated condition by kaolin. The largeer the leakage current during 200ms, the higher harmonic component at 60hz. The harmonic component at 60hz and the odd order harmonics is increase relation without Kaolin Conent. Arcing on the surface was always associated with distortion in the leakage current; hence the low frequency components of the leakage currnent can be used as a means to evaluate the surface degration. Both the fundamental and 3rd & 5th harmonics increase dry-band activity.

  • PDF

애자표면의 오손물 누적에 관한 메커니즘 연구 (A Study on Mechanism about Contaminant Accumulation of Insulator Surface)

  • 박재준
    • 정보학연구
    • /
    • 제8권2호
    • /
    • pp.85-91
    • /
    • 2005
  • We studied a pollution mechanism for simulation of contamination environment in industrial concentrated area of around a metropolitan that made to circulated flow in the chamber. In case of the virgin both side of EPDM or Silicon insulator, we confirmed that the pollution to much more than service insulator in the field. Also contamination of initial state of the virgin didn't falling in spite of physical outside factor easily. This study confirmed to that the silicon was too much accumulated pollution contrast to EPDM insulator from scatter(spray) point to regular interval position use the Kaolin contaminant in the chamber. There are effected to the hydrophobicity of polymer insulator due to the pollution. In ceramic insulator, we get to know that pollution is much more at the Post insulator with vertical than with horizontal setup insulator.

  • PDF

옥외에서 사용되는 배전급 폴리머 현수애자의 오손특성에 관한 연구

  • 이병성;한상옥
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권7호
    • /
    • pp.340-345
    • /
    • 2001
  • Because they have superior insulating properties and lower in price than their ceramic equivalents, polymeric insulators have been used in outdoor insulators. But polymeric insulators mainly using in an heavy contamination area of outdoor could be easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we dismounted polymeric insulators adhered contaminant in the field, and evaluated its electrical characteristics, CA, and ESDD. We also manufactured slurry mixed by some kaolin and salt for the artificial contamination test and measured the degree of contaminant, AC leakage current for these contaminated samples. Consequently, the adhered contaminants to its surface is likely to be affected the performance of insulation.

  • PDF

카올린으로 오손된 애자의 표면방전 및 방사전자파의 신호 분석 (Signal analysis of surface discharge and electromagnetic wave for insulator by kaolin contamination)

  • 박재준
    • 정보학연구
    • /
    • 제7권3호
    • /
    • pp.113-118
    • /
    • 2004
  • 기존의 누설전류기법에서 한층 진일보된 비접촉식 수신용 안테나를 이용하여 복잡한 지역과 광범위한 지역에서 효율적인 고분자 애자의 오손정도를 진단하기 위하여 본 연구를 착수하였다. 착수된 연구는 가공된 챔버 내 설치된 고분자애자에 인위적으로 카올린과 소금을 혼합후 증류수에 혼합하여 인공 오손실시 후 방사전자파와 스페트럼 그리고 부분방전전하량을 동시에 측정 후 전자파 신호에 대한 카올린의 오손정도에 대한 특징추출을 위하여 다우비치 이산웨이블렛 변환기법에 적용 후 각각의 통계적인 파라미터의 특징을 추출하였다.

  • PDF

환경에 따른 송전용 애자의 누설전류 분석 (Analyses of Leakage Current of Transmission Insulator as a Function of Environmental Condition)

  • 최인혁;이동일;김찬영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1166-1170
    • /
    • 2004
  • The leakage currents of transmission insulator were investigated as a function of environmental conditions, such as temperature, humidity, and rainfall. The insulators were artificially contaminated with insoluble yellow soil and kaolin which helped salt to stick on the surface of insulator. The insulators contaminated with the grade of B, C, and D were installed in the KoChang Testing Center. The leakage currents were measured and compared with non-contaminated insulators. The results indicated that the most important factor affecting leakage current was humidity. After heavy rain, the artificially contaminated salt was dissolved, resulting in similar characteristics between with and without contamination

  • PDF

온산공업지역 산성 토양 프로화일 내에서의 점토광물의 생성과 중금속 이온의 거동에 관한 광물학적 연구 (Mineralogical Study on the Clay Formation and Heavy Metal Speciation in the Acidified Soil Profile of the Onsan Industrial Area)

  • 이상수;김수진
    • 한국광물학회지
    • /
    • 제15권1호
    • /
    • pp.1-10
    • /
    • 2002
  • 이 논문은 온산공업단지 내 화강암의 풍화 및 토양화 과정, 그리고 토양 내 중금속 오염과 토양 광물간의 관계에 관한 연구이다. 프로화일 연구를 위해 각 깊이별로 토양시료를 채취하여 각 샘플에 대한 실험분석을 실시하였다. X선 회절분석 결과 주 구성 점토광물은 캐올린 광물과 버미큘라이트, 그리고 미량의 일라이트이다. 포름아마이드 처리를 통해 프로화일 내 토양 중의 캐올린 광물의 종류에 대해 분석한 결과 프로화일 하부에 존재하는 캐올린 광물은 대부분 할로이사이트 임이 밝혀졌으며, 지표면으로 갈수록 상대적으로 캐올리나이트에 대한 할로이사이트의 양이 감소하는 경향을 보이는데, 이는 상부로 갈수록 할로이사이트에서 캐올리나이트로의 전환이 이루어지고 있음을 의미한다. $110^{\circ}C,\;300^{\circ}C,\;550^{\circ}C$ 열처리를 한 결과 X선회절분석 그래프 상의 $10\;{\AA}에서\;14\;{\AA}$ 사이의 피크가 분화된 형태를 보여주는 것이 관찰된다. 이는 시료상에 수산화알루미늄 혼합층 버미큘라이트가 존재함을 지시한다. 이것은 구연산나트륨 처리실험을 통해 버미큘라이트 층간 불순 알루미늄 이온을 추출하여 원형상으로 전환시킴으로써 열처리시 $14\;{\AA}$피크가 다시 $10\;{\AA}$으로 변화하는 것을 관찰함으로써 재확인하였다. 토양의 수소이온농도 분포 양상이 하부에서 3.9, 상부에서 3.6으로 상부로 갈수록 산성화경향이 심해지는 경향을 보여주는데, 이는 산성화된 토양에서 안정적으로 나타나는 수산화알루미늄 혼합층 버미큘라이트의 존재를 뒷받침하고 있다. 토양 내 중금속 이온의 존재양상에 대한 연구를 위해 연속추출실험을 실시하였다. 그 결과 상대적으로 많은 양의 중금속 이온이 프로화일의 상부의 철/망간 산화물과 유기물에 흡착되어 있으며 점토광물에는 적은 양만이 흡착되어 있는 것으로 밝혀졌다. 이러한 결과는 대부분의 중금속 오염물들이 상부 토양에 농집되어 있고 점토광물에는 낮은 중금속 함량을 보여주는 것은 산성화된 토양을 이루고 있는 주 점토광물인 캐올린광물과 수산화알루미늄 혼합층 버미큘라이트가 낮은 흡착능력을 가지고 있기 때문인 것으로 판단한다.

세라믹 막여과의 성능향상을 위한 응집 전처리의 적용 (Application of coagulation pretreatment for enhancing the performance of ceramic membrane filtration)

  • 강준석;송지영;박서경;정아영;이정준;서인석;채선하;김성수;김한승
    • 상하수도학회지
    • /
    • 제31권6호
    • /
    • pp.501-510
    • /
    • 2017
  • In this study, it is estimated that ceramic membrane process which can operate stably in harsh conditions replacing existing organic membrane connected with coagulation, sedimentation etc.. Jar-test was conducted by using artificial raw water containing kaolin and humic acid. It was observed that coagulant (A-PAC, 10.6%) 4mg/l is the optimal dose. As a results of evaluation of membrane single filtration process (A), coagulation-membrane filtration process (B) and coagulation-sedimentation-membrane filtration process (C), TMP variation is stable regardless of in Flux $2m^3/m^2{\cdot}day$. But in Flux $5m^3/m^2{\cdot}day$, it show change of 1-89.3 kpa by process. TMP of process (B) and (C) is increased 11.8, 0.6 kpa each. But, the (A) showed the greatest change of TMP. When evaluate (A) and (C) in Flux $10m^3/m^2{\cdot}day$, TMP of (A) stopped operation being exceeded 120 kpa in 20 minutes. On the other hand, TMP of (C) is increased only 3 kpa in 120 minutes. Through this, membrane filtration process can be operated stably by using the linkage between the pretreatment process and the ceramic membrane filtration process. Turbidity of treated water remained under 0.1 NTU regardless of flux condition and DOC and $UV_{254}$ showed a removal rate of 65-85%, 95% more each at process connected with pretreatment. Physical cleaning was carried out using water and air of 500kpa to show the recovery of pollutants formed on membrane surface by filtration. In (A) process, TMP has increased rapidly and decreased the recovery by physical cleaning as the flux rises. This means that contamination on membrane surface is irreversible fouling difficult to recover by using physical cleaning. Process (B) and (C) are observed high recovery rate of 60% more in high flux and especially recovery rate of process (B) is the highest at 95.8%. This can be judged that the coagulation flocs in the raw water formed cake layer with irreversible fouling and are favorable to physical cleaning. As a result of estimation, observe that ceramic membrane filtration connected with pretreatment improves efficiency of filtration and recovery rate of physical cleaning. And ceramic membrane which is possible to operate in the higher flux than organic membrane can be reduce the area of water purification facilities and secure a stable quantity of water by connecting the ceramic membrane with pretreatment process.