• Title/Summary/Keyword: KVP model

Search Result 5, Processing Time 0.016 seconds

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

Image Restoration in Dual Energy Digital Radiography using Wiener Filtering Method

  • Min, Byoung-Goo;Park, Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.171-176
    • /
    • 1987
  • Wiener filtering method was applied to the dual energy imaging procedure in digital radiography(D.R.). A linear scanning photodiode arrays with 1024 elements(0.6mm H 1.3mm pixel size) were used to obtain chest images in 0.7 sec. For high energy image acquisition, X-ray tube was set at 140KVp, 100mA with a rare-earth phosphor screen. Low energy image was obtained with X-ray tube setting at 70KVp, 150mA. These measured dual energy images are represented in the vector matrix notation as a linear discrete model including the additive random noise. Then, the object images are restored in the minimum mean square error sense using Wiener filtering method in the transformed domain. These restored high and low energy images are used for computation of the basis image decomposition. Then the basis images are linearly combined to produce bone or tissue selective images. Using this process, we could improve the signal to noise ratio characteristics in the material selective images.

  • PDF

Denoising of Digital Mammography Images Using Wavelet Transform (웨이블릿을 이용한 디지털유방영상의 노이즈 제거)

  • Choi, Seokyoon;Ko, Seongjin;Kang, Sesik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.181-189
    • /
    • 2013
  • The optimum exposure parameters are found when examined using the automatic mode in FFDM. improve the image quality by applying denoising algorithm and propose methods to reduce AGD(Average Grandular Dose) a patient can receive. For the experiment, Nuclear Associates Model 18-222 phantom was the used, and the entrance dose and AGD were measured. And then, Signal, Noise, SNR and FOM(Figure of Merit) were measured, compared and analyzed image denoising before and after. As the experiment result, first, SNR was the highest at Mo/Mo 23kVp and W/Rh 35kvp was the lowest for the average glandular dose. It showed to use 28kVp of W/Rh to be the best through the result of FOM. SNR was the highest at Mo/Mo 23kVp(image denoising), and it showed to W/Rh and 28kVp to be the best in the FOM result which AGD was considered at the same time. By the image denoising, it is possible to reduce noise while maintain important information in the image.

Teachers' Conceptions about the Genetic Determinism of Human Behaviors (교사들이 가지는 사람의 행동적 특징에 대한 유전자 결정론적 인식)

  • Youn, Se Jin;Seo, Hae-Ae
    • Journal of The Korean Association For Science Education
    • /
    • v.34 no.4
    • /
    • pp.407-415
    • /
    • 2014
  • Genetic determinism of human behaviors is considered as a philosophical perspective that genes in humans determine biological as well as social traits. However, many biologists agree that human traits are determined by interactions between genes and genes, as well as between genes and environments. In this context, genetic determinism still affect ideas of the general public as well as research directions of biologists. According to Cl$\acute{e}$ment's KVP model (Cast$\acute{e}$ra & Cl$\acute{e}$ment, 2012), teachers' conceptions of genetic determinism influence students' concepts of genetics. This study intends to investigate teachers' conceptions on genetic determinism of human behaviors. For this end, a questionnaire adopted from a previous research (Cast$\acute{e}$ra & Cl$\acute{e}$ment, 2012) has been administered to 308 teachers including 151 pre-service and 157 in-service. Factor analysis has been conducted to extract major factors and one-way ANOVA has been employed to find out differences in extracted factors among different groups of teachers. Four factors have been extracted from 14 items of questionnaire, including factor 1, a perspective of genetic determinism of gender differences in intellectual ability, social status, and emotional traits; factor 2, a perspective of genetic determinism of individual differences in intellectual ability; factor 3, a perspective of genetic determinism of individual differences in biological immune function and behavioral trait; and factor 4, a perspective of genetic determinism of ethnic differences. From the results of One-way ANOVA among teacher groups on four factors, first, it has shown a significant difference in factor 1 (F=3.325, p=.006), factor 3 (F=3.320, p=.006) and factor 4 (F=4.325, p=.001) due to their subject matters. In post-hoc comparison there have been no significant difference between biology teachers and other teachers. It has also been found that there was a significant difference between pre-service and in-service teachers in factor 1 (t=-3.938, p=.000) and factor 4 (t=-3.121, p=.002) and in-service teachers are more genetic deterministic than pre-service teachers. Finally, different religions have no influence on teachers' conceptions of genetic determinism of human behaviors.

Remote Measurement of the Automobile′s ECU Signals with KWP2000 using Bluetooth Module (Bluetooth 모듈을 이용한 KWP2000 차량 ECU신호의 원격 계측)

  • Choi Kwang-Hun;Kwon Tae-Kyu;Lee Seong-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.10
    • /
    • pp.86-93
    • /
    • 2004
  • This paper presents the remote measurement of the ECU signals adopted with KWP 2000 protocol using the wireless communication technique of bluetooth. The bluetooth technology will be the most promising network paradigm which can open the new area in the information technology. Especially, bluetooth module is able to link all the electrical products and personal computers to cellular phone or PDA. This research has a try to design a wireless measurement model of ECU signal based on the car telemery system using bluetooth device. In order to measure the ECU signals, we designed the interface circuits which is able to communicate between the ECU system and the terminal circuits according to the ISO, SAE regulation of communication protocol standard. A microprocessor S3c341 OX is used for the system control and communication of ECU signals. The embedded system software is programmed to measure the ECU signals using the ARM compiler and ANCI C based on Micro/OS-II kernel to communicate between two bluetooth modules using bluetooth stack. The remote measurement of ECU signals using the bluetooth was designed and implemented to evaluate the performance of wireless network to the transmit measurement data. The possibility for the remote measurement of the self diagnosis signals of ECU adopted with KWP2000 protocol verified through the developed systems and algorithms in embedded system.