• Title/Summary/Keyword: KS (Korea Standard)

Search Result 422, Processing Time 0.029 seconds

A Three-Set Type Korean Keyboard Model, 38K, with High Compatibility to the KS Computer Keyboard

  • Kim, Kuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.355-363
    • /
    • 2014
  • Objective:The purpose of this study is to design a three-set type (Sebulsik) keyboard that is to input Korean text with no shifted keys and also compatible with the standard Korean computer keyboard or ANSI keyboard. Background: The KS computer keyboard is two-set type (Dubulsik). Existing and proposed designs of three-set type of past studies are not compatible with KS or ANSI keyboard and are complex with many redundant letters. Method: The number of Korean letters for 3-set type is analyzed. Then Korean letters are arranged with normality and with spatial compatibility to the KS Korean keyboard, and symbols were arranged to same positions with ANSI keyboard. Results: Initial consonants of 14 numbers and 6 vowels are arranged as exactly same positions of KS keyboard, and other vowels are arranged with spatial compatibility. Symbols are arranged to the same positions with ANSI keyboard, and 10 digits are confirmed and has compatibility to International standard. Conclusion: A 38-key model, 38K, is designed to require minimal keys to input Korean text with no shifted keys, increased the compatibility to the KS Korean computer keyboard. Application: Using the proposed 38-key model, 38K, it can be taken into account for keyboards in industrial production. It is applicable to user group of 3-set type Korean keyboard with more easy than past keyboards.

A Self Visual-Acuity Testing System based on the Hand-Gesture Recognition by the KS Standard Optotype (KS 표준 시표를 어용한 손-동작 인식 기반의 자가 시력 측정 시스템)

  • Choi, Chang-Yur;Lee, Woo-Beom
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.4
    • /
    • pp.303-309
    • /
    • 2010
  • We proposes a new approach for testing the self visual-acuity by using the KS standard optotype. The proposed system provides their hand-gesture recognition method for the convenient response of subjects in the visual acuity measurement. Also, this system can measure a visual-acuity that excludes the examiner's subjective judgement or the subject's memorized guess, because of presenting a random optotype automatically by computer without a examiner. Especially, Our system guarantees the reliability by using the KS standard optotype and its presentation(KS P ISO 8596), which is defined by the Korea Standards Association in 2006. And the database management function of our system can provide the visual-acuity data to the EMR client easily. As a result, Our system shows the 98% consistency in the limit of the ${\pm}1$ visual-acuity level error by comparing the visual-acuity chart test.

Review of Revised KOLAS Standard Regulations for Test and Calibration Laboratories: General Requirements for a Competence of Management System (KOLAS 시험 및 교정기관 운영을 위한 개정된 표준 규정 리뷰: 적격성에 대한 일반 요구사항)

  • Kim, Hee Sun
    • Applied Chemistry for Engineering
    • /
    • v.31 no.3
    • /
    • pp.334-337
    • /
    • 2020
  • Korea Laboratory Accreditation Scheme (KOLAS) introduces a new standard for test and calibration laboratories to operate management system and to produce valid results in accordance with the requirements of KS Q ISO/IEC 17025. The standard is based on the national standard law for the accreditation of test, inspection and calibration laboratories. International Laboratory Accreditation Cooperation (ILAC) has recently established its new criteria. The accredited test and calibration laboratories should complete the transition of their management system by November 2020 following KS Q ISO/IEC 17025:2017. A total of 899 of test, inspection and calibration laboratories in Korea are influenced by the transition policy. This paper summarized general requirements for a competence of laboratory management system.

Evaluation of Aggregates Properties Depending on Producing Sectors and Regions in Korea (전국 골재산지 권역별 콘크리트용 골재의 물성 평가)

  • Han, Min-Cheol;Lee, Jun-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.6
    • /
    • pp.499-506
    • /
    • 2017
  • This study is to present empirical data about the needs for quality security of aggregate by randomly selecting aggregate from 4 major locations including A, B, C, D province in Korea, by investigating its quality status in terms of physical properties and particle distribution based on Korean industrial standards(KS). The test results indicated that wide variance in quality, and some of aggregate samples were far below the standard, still many of them are not satisfying KS standards. In addition, the current aggregate manufacturing process that does not include inspection of particle size distribution by sieving and fineness modulus, can induce a possibility of non-KS aggregate's distribution; this provide that the current status of aggregate quality security of Korea is seriously threatened. Thus, it is important to secure each aggregate's quality level under KS standards.

Current-Voltage Measurement Behavior of the CIGS Solar Module through the Evaluation of KS C 8562 Standard (KS C 8562 평가를 통한 CIGS 태양광모듈의 출력 거동 분석)

  • Kyung Soo Kim
    • Current Photovoltaic Research
    • /
    • v.12 no.2
    • /
    • pp.41-47
    • /
    • 2024
  • CIGS solar cells are thin film solar cells that have excellent light absorption coefficient and can be manufactured with high efficiency through the use of low materials. In Korea, they must pass KS certification for home and commercial installation. KS C 8562 is a standard for evaluating the durability of CIGS and thin film amorphous silicon solar modules and deals with contents such as light, temperature, humidity, and mechanical durability. Unlike general crystalline silicon solar modules, the CIGS solar module has a different behavior of output change through these environmental tests, so if it shows 90% or more of the rated output suggested by the manufacturer after the final test, it is judged to be a suitable product. In this paper, the output before and after individual tests was measured through the test method of KS C 8562 to observe the output change and to discover the vulnerabilities of the CIGS solar module when exposed to various environments. Through this, it was confirmed that humidity exposure was the most vulnerable and that it had output recovery characteristics for light (visible light and ultraviolet rays). This study attempted to present the output behavior characteristics and data of the CIGS module at the time when the high efficiency thin film photovoltaic module market is expected to be created in the future.

- A Study on KS A ISO 2859-2 and 2859-3 for the Best Companies in Safety management - (안전경영 우수기업을 위한 KS A ISO 2859-2 및 2859-3에 대한 고찰)

  • Lim Jae Geun;Cho Byung Sun;Jung Soo Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.4
    • /
    • pp.83-97
    • /
    • 2004
  • The growing importance of product quality is becoming more and more daily apparent as we enter the age of globalization around the world. And the product safety is getting more focus as well as product quality. As a result, many domestic companies are putting a lot of emphasis on safety measures and management activities and these companies' products are mainly superior to other companies' product. When we separate the product quality procedure into 3 steps, i.e. quality secure-quality confirm-quality guarantee, of course the 1st step is the most important, but also End step of product quality confirm process is important. And in mass production environment, sampling inspection is more desirable than the 100 % inspection procedure. As a part of globalization trend, KS system is also being revised and reestablished based on ISO, IEC, etc. which are based on international standard. Conventional KS sampling inspection standards were in many areas quite different from ISO sampling standards, only KS A 3102, 3104, 3151 are left and the rest become obsolete, and even the ones that are still around are planned to the gone step by step. It has been already 3 years since the new KS A ISO 2859-0-3 sampling inspection process has been established which the abolition of the popular KS A 3101, KS A 3105, KS A 3109, yet the implementation rate is very slow. This study will attempt to analyze the new KS A ISO 2859-2 and KS A ISO 2859-3, and try to understand the difference as that the new standard can be easily understood and used widely among companies, by using examples. Our attempt is to help implement with the companies with active safety involvement but the final result can be spread among other companies as well in the near future.

A Study on the Suggestion for the Revision of Standard Sizing System for Female Adult's Garments (성인 여성복의 KS 치수 표준 개정을 위한 제안 연구)

  • Nam, Yun-Ja;Lee, Jeong-Yim;Jung, Jae-Eun
    • Fashion & Textile Research Journal
    • /
    • v.16 no.5
    • /
    • pp.776-784
    • /
    • 2014
  • KS K 0051(2009) was established in 1990 and revised in 1994, 1999, 2004 and 2009. Recently the structure of apparel production and distribution are changing like as small quantity batch production, increase of importing abroad apparel and increase of on-line shopping mall. Based on Social and economic conditions, examine the potential for use of KS K 0051(2009) standard sizing system for female adult's garments are needed. Through which, it was intended to suggestion for the revision of standard sizing system for female adult's garments which can facilitate communication among consumer, producer and sellers. The improvement point was discussed through review of the current KS K 0051 (2009) and abroad standard sizing system for female adult's garments, ISO 3637(1977), ISO 4416(1981), BS EN 13402-2(2002), BS EN 13402-3(2004), JIS L 4005(2001) and GB/T 1335.2(2008). Also, the revision of standard sizing system for female adult's garments was suggested using data of 6th Size Korea. As a result of this study, in the revision, formal wear, casual wear, training wear and under wear were separated to simplify the classification and the classification of body type were excluded. Also, it is possible that size designation was simplified through optional notation and letter code based on bust girth could be marked together in casual wear.

The comparison of the basic human body measurement definitions and anthropometric terms between KS and ISO (인체 측정 방법 및 측정 항목에대한 KS와 ISO의 비교)

  • 이영숙;김동진;남경희;안병덕;이관석
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.247-255
    • /
    • 1997
  • In this study, the comparison of the basic human body measurement definitions and anthropometric terms between the Korean Standard and the International Standard. Measurement definitions, measurement method and measurement terms of the international standard ISO 8559, 7250 were compard with the KSRI-88-103-IR. We have tried to suggest the new methods and new terms such as eye height, waist height, arm length.

  • PDF

A Study on Floor Slip Resistance Standard and Test Method for BF Certification (BF인증을 위한 바닥 마감재 미끄럼 성능기준 및 측정방법에 대한 연구)

  • Shin, Dong-Hong;Seong, Ki-Chang;Park, Kwang-Jae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.75-83
    • /
    • 2019
  • Purpose: There are no clear criteria for slip performance in the BF certification process, so the evaluator relies on subjective judgments depending on the field situation. Physical criteria for determining the slip performance of various floor finishes are not clear. C.S.R., the only criterion currently being used to check slip performance, may raise questions about its coverage, feasibility and reliability. Method: For an analysis of domestic standards and status, KS L 1001, KS M 3510, and KS F 2375. External standards are analyzed for ADA Standard, ANSI Standard, and BS EN Standard. Analyze the test methods and evaluation criteria of O-Y-PSM, BPT, and the dynamic slip resistance test used in these criteria. It also presents an improvement plan for the rational presentation of standards. Results: To date, various kinds of test methods and measuring devices of the slip resistance coefficient have been developed, but there are not many ways to trust useful results related to user safety. Reliability and thoroughly verified test methods and criteria should be used to assess the slip performance of the floor. In order to improve the standard for the evaluation of slip performance in Korea, the existing standard should first be raised to the same level as the overseas standard, and the application of the discriminatory standard should be applied considering the characteristics and usage patterns of each space. Implication: Currently, Korean standards propose various test methods, but the proper use of test methods, scope and assessment criteria are not established, so improvement of the comprehensive standard is necessary.