• Title/Summary/Keyword: KPS

Search Result 771, Processing Time 0.03 seconds

The Study of Comparison with Industrial Standard of South-North Korea in Clothing (남.북한 의류 산업 표준에 관한 비교 연구)

  • 박지연;김용필;윤덕균
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.26 no.4
    • /
    • pp.1-5
    • /
    • 2003
  • This paper is for standard of South and North Korea clothing, especially size. It is analysis and make a comparative study of KS K 0050-0052 which is South Korea industrial standard) and KPS 8477.1∼3, 8477.6, 8477.9, 10253 which is North Korea's. With this research, it is found the difference and sameness, then this paper suggests the method for combining two different standard systems.

시선집중, 안전경영 우수기업 - 철저한 안전관리 바탕으로 발전설비 명가로 우뚝, 한전 KPS(주) 서인천사업처

  • Kim, Seong-Dae
    • The Safety technology
    • /
    • no.195
    • /
    • pp.18-20
    • /
    • 2014
  • 전국 산업현장 어디에서나 안전은 중요하게 여겨진다. 하지만 안전이 더욱 각별하게 다가오는 곳이 있다. 바로 국가 산업의 기초가 되는 금속공업, 화학공업 등 국가기반산업 현장이 그곳이다. 이 가운데 특히 전력산업에서 안전은 한 나라의 경제와 사회를 좌지우지할 만큼 엄청난 영향을 미친다. 지난 2011년 9월 15일 발생한 대정전 사태를 생각해보면 쉽게 이해가 갈 것이다. 이에 따라 발전소의 안전운행을 위해 정비 및 유지 보수 등의 업무를 수행하는 한전KPS(주) 서인천 사업처에서는 남다른 안전관리활동을 전개하고 있다. 이곳에서 어떻게 안전을 확보해 나가고 있는지 살펴봤다.

  • PDF

Preparation of Monodisperse Submicron-Sized Polymeric Particles by Emulsifier-Free Emulsion Polymerization (무유화중합에 의한 단분산 Submicron 크기의 고분자 미립자의 제조)

  • Lee, Ki-Chang
    • Journal of Adhesion and Interface
    • /
    • v.13 no.3
    • /
    • pp.101-108
    • /
    • 2012
  • Narrowly dispersed poly(BMA-co-MMA) and PBMA latices (PSD : 1.002~1.008) were synthesized successfully by surfactant-free emulsion polymerization with 2,2' azobis(2-methyl-propionamidine) dihydrochloride (AIBA) and $K_2S_2O_8$ (KPS). The number average particle diameter and the number average molecule weight were found to be 160~494 nm and (1.25~7.55) ${\times}10^4$, respectively. The influences of BMA/MMA ratio, monomer and initiator concentrations, addition of DVB/EGDMA crosslink agent, and polymerization temperature on the polymerization rates and on the particle size and molecular weight were studied. The rate of polymerization increased with increasing MMA concentration in BMA/MMA weight ratio. The particle diameter as well as the polymer molecular weight could be controlled easily by controlling the BMA/MMA weight ratio, monomer concentration, AIBA and KPS concentration, and polymerization temperature.

Zero-Correlation Linear Cryptanalysis of Reduced Round ARIA with Partial-sum and FFT

  • Yi, Wen-Tan;Chen, Shao-Zhen;Wei, Kuan-Yang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.1
    • /
    • pp.280-295
    • /
    • 2015
  • Block cipher ARIA was first proposed by some South Korean experts in 2003, and later, it was established as a Korean Standard block cipher algorithm by Korean Agency for Technology and Standards. In this paper, we focus on the security evaluation of ARIA block cipher against the recent zero-correlation linear cryptanalysis. In addition, Partial-sum technique and FFT (Fast Fourier Transform) technique are used to speed up the cryptanalysis, respectively. We first introduce some 4-round linear approximations of ARIA with zero-correlation, and then present some key-recovery attacks on 6/7-round ARIA-128/256 with the Partial-sum technique and FFT technique. The key-recovery attack with Partial-sum technique on 6-round ARIA-128 needs $2^{123.6}$ known plaintexts (KPs), $2^{121}$ encryptions and $2^{90.3}$ bytes memory, and the attack with FFT technique requires $2^{124.1}$ KPs, $2^{121.5}$ encryptions and $2^{90.3}$ bytes memory. Moreover, applying Partial-sum technique, we can attack 7-round ARIA-256 with $2^{124.6}$ KPs, $2^{203.5}$ encryptions and $2^{152}$ bytes memory and 7-round ARIA-256 employing FFT technique, requires $2^{124.7}$ KPs, $2^{209.5}$ encryptions and $2^{152}$ bytes memory. Our results are the first zero-correlation linear cryptanalysis results on ARIA.

The Experimental Study and Comparison on Usage of Vibration Monitoring Sensors for Positioning of Balancing on Rotating Machinery (진동 감시용 위치 결정 센서의 위상오차에 대한 실험적 고찰과 비교 평가)

  • Oh, Seung-Tae;Yoo, Mu-Sang;Bong, Suk-Keun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.2
    • /
    • pp.101-107
    • /
    • 2015
  • Field balancing is required in any kind of phase information for the determination location balancing mass toward a rotor unbalance mass. Phase or phase angle is a measurement of the relationship of how one vibration signal which relates to another vibration signal and is commonly used to calculate the placement of balance weight. In this paper, A right guideline shows the photo optical speed sensor as the external KeyPhasor is a very useful when diagnosing machinery vibration problems on considering a phase lag comparing to the laser optical speed sensor. Some experimental results generate the interesting phase errors when appling to a wrong conditions. So, Usage of photo optical speed sensor which is used primarily to measure the shaft rotating speed serves as a reference for measuring vibration phase information has effect on the placement of phase angle how it was misunderstood. This paper will help a right method to search for the position of balancing weight and serves as baseline for further measurements using low cost and much easier user convenience. It is concluded that the propose baseline is likely to be applicable to apply to the practical field balancing weight.

Part 1 : Soap-Free Emulsion Copolymerization of Styrene with COPS-I (Part 1 : Styrene과 COPS-I의 무유화공중합)

  • Lee, KiChang;Choo, HunSeung;Ha, JeongMi
    • Journal of Adhesion and Interface
    • /
    • v.15 no.3
    • /
    • pp.93-99
    • /
    • 2014
  • Monodisperse poly[styrene-co-(COPS-I)] latices in the size range of 165~550nm were successfully prepared by soap-free emulsion polymerization with various polymerization conditions (Styrene, COPS-I, KPS, DVB concentrations and polymerization temperature). In general, the COPS-I and KPS, DVB concentrations and polymerization temperature were closely related to the polymerization rate and the number of particles, molecular weight, and zeta potential. The polymerization rate and zeta potential increased, but molecular weight decreased, with increasing in the number of particles.

Signal Modulation Techniques and Performance Analysis for KPS Signal Design

  • Shin, Heon;Han, Kahee;Joo, Jung-Min;Won, Jong-Hoon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.9 no.4
    • /
    • pp.293-304
    • /
    • 2020
  • In this paper, various modulation techniques, including the legacy Global Navigation Satellite System (GNSS) signal modulation techniques, are introduced and the spectral characteristics and correlation characteristics of signals with various modulation techniques are analyzed based on numerical simulation. With the development of various GNSS services, the limited frequency band has become increasingly saturated, and issues of interoperability and compatibility have emerged in the new GNSS design. Since the efficient allocation of frequency resources is closely related to spectrum design, modulation techniques are one of the important signal design parameters of new signal design. Signal modulation techniques are closely related to various figure of merits (FoMs) as well as spectrum characteristic, and in some cases there is a complicated trade-off between FoMs. Thus, the FoMs associated with modulation technology should be analyzed and the best signal candidates should be chosen carefully via the trade-off analysis for FoMs. In this paper, we define the modulation technique based on Phase Shift Keying (PSK), Binary Offset Carrier (BOC) and Continuous Phase Modulation (CPM) for the design of KPS signals, and the FoMs of signals in terms of spectrum and correlation function are evaluated. Signals with various modulation techniques are implemented through a numerical simulation, and the relevant FoMs are analyzed.