• Title/Summary/Keyword: KNEE JOINT TORQUE

Search Result 94, Processing Time 0.027 seconds

The analysis of biomechanical gender difference of K-Pop dance lower body movement (K-Pop 댄스 하지동작의 생체역학적 남녀 차이 분석)

  • Jang, Young-Kwan;Hong, Su-Yeon;Ki, Jae-sug;Jang, In-Young
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.1
    • /
    • pp.95-101
    • /
    • 2017
  • The purpose of this study was to investigate the biomechanical of K-Pop dance movement. The study was conducted on 15 male and 15 female subjects in 20-30 age groups. And they choose 150 K-Pop dance choreographies in the top 10 ranking of the main charts. We analyzed the RoM, joint moment and impulse force of the highlight movements. First, During the K-Pop dance motion, the usage of knee joints are more than the hip joints and the ankle joints, and female dancers has a larger range of motion than the male dancers. Second, male dancer uses more than female dancers when they compared the load of male dancers and female dancers. In particular, flexion and extension of the hip joints are mostly used in this study. Third, the impulse force of male dancers was greater than of female dancers, but it was statistically insignificant, this is equal to the impulse on walking. In conclusion, Female dancers use more range of motion than male dancers, but male dancer choreography requires greater torque, which can strain joints. Most choreographic exercises involve movements such as hip joint, knee joint, flexion of ankle joint, extension, rotation, and jumping.

Effects of Six-week Resistance Exercise using an Outdoor Knee Extension Machine on Function and Structure of the Knee Extensor Muscles (6주간 야외용 운동기구를 사용한 저항운동이 노인 여성의 무릎신전근 기능 및 구조에 미치는 영향)

  • Choi, Dong-Sung;Kim, Jin-Sun;Kim, Dong-Il;Jeon, Justin-Y.;Won, Young-Shin;Lee, Hae-Dong
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.2
    • /
    • pp.201-208
    • /
    • 2012
  • The purpose of this study was to investigate the effect of leg extension exercises performed on outdoor resistance exercise machines on knee extension muscle strength and quadriceps muscle group cross sectional area (CSA) in elderly women. Two groups were recruited for this study, including an exercise group (EG: n=13, $71.38{\pm}2.79$ yrs) and a control group (CG: n=5, $73.4{\pm}5.94$), In all subjects, maximum isometric and isokinetic muscle strength of knee flexion and extension were measured using an isokinetic dynamometer (Cybex(R) Humac Norm Testing & Rehabilitation System, USA). Quadriceps muscle group CSA were measured using MRI (Philps, Intera 1.5 T, NE Netherlands). The results of this study showed that post-intervention isometric knee extension peak torque value were higher than pre-intervention measures in the EG. However, the EG did not show improvement in quadriceps muscle group CSA, Also, no differences in the shift of optimal knee joint angle were observed between pre and post-intervention exercise. Outdoor leg extension exercise showed small increases in muscle strength in comparison to other resistance training exercises. The results of this study suggest that because outdoor leg extension exercise machines lack a progressive loading mechanism, significant increases in muscle strength may not be obtained.

Immediate Effects of High-frequency Diathermy on Muscle Architecture and Flexibility in Subjects With Gastrocnemius Tightness

  • Kim, Ji-hyun;Park, Joo-hee;Yoon, Hyeo-bin;Lee, Jun-hyeok;Jeon, Hye-seon
    • Physical Therapy Korea
    • /
    • v.27 no.2
    • /
    • pp.133-139
    • /
    • 2020
  • Background: The gastrocnemius (GCM) is one of the lower extremity muscles that tend to tighten easily. GCM tightness results in limited ankle dorsi-flexion (DF), especially when the knee joint is fully extended. Joint flexibility is determined by the morphological and physiological characteristics of joints, muscles, tendons, and ligaments. Impaired joint flexibility can be attributed to increased susceptibility to muscle injury. High-frequency diathermy is clinically used to reduce pain and muscle tightness and to improve limited range of motion. Objects: This study aimed to investigate the immediate effects of high-frequency therapy in subjects with GCM tightness. Methods: The study was designed as a one-group before-after trial. The subjects included 28 volunteers with GCM tightness (an active ankle DF angle of less than 12°) without any known neurological and musculoskeletal pathologies in the ankle and calf areas. WINBACK Transfer Electrode Capacitive and Resistive Therapy equipment was used to apply high-frequency therapy to the subjects' GCMs for 10-15 minutes. The pennation angle and the fascicle length of the GCM were measured using ultrasonography. The flexibility of the ankle joint, peak torque to the passive ankle DF (Biodex), and soft tissue stiffness (MyotonPRO) were also measured. Results: The pennation angle was significantly decreased following the treatment; however, no significant difference in the fascicle length was found (p < 0.05). The flexibility was significantly increased and both the passive peak torque to passive ankle DF and the soft tissue stiffness significantly decreased (p < 0.05). Conclusion: High-frequency therapy is immediately effective for improving the muscle's architectural properties and functional factors in subjects with GCM tightness. Further longitudinal clinical studies are required to investigate the long-term effects of high-frequency therapy on subjects with GCM tightness from various causes.

Design and Optimization Study of Active Trasfemoral Prosthesis leg (대퇴 절단 환자를 위한 능동대퇴의지구조 설계 및 최적화 연구)

  • Lee, K.H.;Chung, J.H.;Lee, C.-H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.41-46
    • /
    • 2013
  • IIn this paper, active trasfemoral prosthesis leg is designed for the handicapped who lost their legs upon knee. It is important to design proper knee joint to mimic walking motion of hyman. 1 degree-of-freedom active trasfemoral prosthesis leg is designed with knee joint. Operating angle and torque have been calculated using kinematics of three linkages in prosthesis leg. Finite element analysis of major components is performed to evaluate the safety under operating condition and to reduce weights. Minimum volumes of components are obtained by optimization as satisfying safety requirements. The results show that about 35% of weight of components is reduced.

  • PDF

Virtual Model Control of a Posture Balancing Biped Acrobatic Robot with Fuzzy Control for Pendulum Swing Motion Generation (진자 흔들기 퍼지 제어기가 추가된 가상모델 제어 2족 곡예로봇 자세 균형 제어)

  • Lee, Byoung-Soo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.11
    • /
    • pp.904-911
    • /
    • 2001
  • A broomstick swinging biped acrobatic controller is designed and simulated to show capability of the system of controllers: virtual model controller is employed for the robot\`s posture balancing control while a higher level fuzzy controller modulate the one of the virtual model controller\`s parameter for the pendulum swinging motion generation. The robot is of 7 degree-of-freedom, 8-link planar bipedal robot having two slim legs and a body. Each leg consists of a hip joint, a knee joint, an ankle joint and the body has a free joint at the top in the head at which a freely rotating broomstick is attached. We assume that the goal for the acrobat robot is to maintain a body balance in the sagittal plane while swinging up the freely up the freely rotating pendulum. We also assume that the actuators in the joints are all ideal torque generators. The proposed system of controllers satisfies the goal and the simulation results are presented.

  • PDF

Effects of Ankle Joint Mobilization With Movement on Lower Extremity Muscle Strength and Spatiotemporal Gait Parameters in Chronic Hemiplegic Patients (만성 편마비 환자의 발목에 적용한 능동운동을 동반한 관절가동술이 하지근력과 보행의 시공간적 변수에 미치는 영향)

  • An, Chang-Man;Won, Jong-Im
    • Physical Therapy Korea
    • /
    • v.19 no.3
    • /
    • pp.20-30
    • /
    • 2012
  • The purpose of this study was to determine the effect of ankle joint mobilization with movement (MWM) on the range of motion (ROM) in the ankle, on the muscle strength of lower extremities, and on spatiotemporal gait parameters in chronic hemiplegic patients. Fifteen subjects with chronic stroke were divided into two groups: an experimental group (8 subjects) and a control group (7 subjects). Both groups attended two or three sessions of physical therapy each week. The experimental group also attended additional MWM training sessions three times a week for five weeks. For both groups, the ROM of the ankle, the muscle strength of the lower extremities, and the spatiotemporal gait parameters in paretic limbs were evaluated before and after the training period. The results showed that the experimental group experienced more significant increases than did the control group in terms of passive (6.10%) and active (21.96%) ROM of the ankle, gait velocity (12.96%), and peak torque, of the knee flexor (81.39%), the knee extensor (24.88%), and the ankle plantar flexor (41.75%)(p<.05). These results suggest that MWM training in patients with chronic stroke may be beneficial in increasing ROM in the ankle, muscle strength in the lower extremities, and gait speed.

Evaluation of Bio-Mechanical Character istics According to Loading Deviation Methods dur ing Rowing Exercise (로잉운동의 부하편차 방식 적용에 따른 상하지 생체 역학적 평가)

  • Kang, Seung-Rok;Jung, Gu-Young;Moon, Dong-An;Jeong, Jang-Sik;Kim, Jung-Ja;Kwon, Tae-Kyu
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.3
    • /
    • pp.369-382
    • /
    • 2011
  • The purpose of this study was to verify the validation of exercise effect with loading deviation during rowing exercise. We performed evaluation of based physical fitness and joint torque before the experiment for finding muscle unbalance. So we recruited twenty four subjects who have bigger muscle strength in more 20% than average one. Subjects divided two groups. One is dominant upper limbs(DU) and the other was dominant lower limbs(DL). Subjects performed rowing exercise using electric equipment (Robo.gym.Humonic.korea). Exercise is performed four sets a day including 25 times a set, and three days a week. Measurement consist of evaluation of based physical fitness and joint torque using biodex(biodex system3.USA). Evaluation of exercise effect performed each week in joint torque of shoulder, lumbar and knee joint and each month in based physical fitness. Also we adapted 30% of 1RM for muscular endurance and 70% of 1RM for muscle strength as exercise load. The results showed that the difference of maximal peak torque were getting increase significantly during exercise. Also difference of various factor in based physical fitness were getting increase significantly except flexibility and agility. This interpreted that rowing exercise with loading deviation types could provide muscle strength and muscular endurance exercise in same time. These results could be interpret to two ways. One is effect of improving physical fitness for rowing exercise and the other meaned validation of loading deviation in rowing exercise. Our study is going to verify the validation of loading deviation during rowing and we found out that loading deviation could provide muscle strength and muscular endurance exercise for improving muscle unbalance. Our study can be used development of exercise equipment and program for normal people with muscle unbalance. Also that provide effect of whole body exercise to anybody.

Trajectory Optimization for Biped Robots Walking Up-and-Down Stairs based on Genetic Algorithms (유전자 알고리즘을 이용한 이족보행 로봇의 계단 보행)

  • Jeon Kweon-Soo;Kwon O-Hung;Park Jong-Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.4 s.181
    • /
    • pp.75-82
    • /
    • 2006
  • In this paper, we propose an optimal trajectory for biped robots to move up-and-down stairs using a genetic algorithm and a computed-torque control for biped robots to be dynamically stable. First, a Real-Coded Genetic Algorithm (RCGA) which of operators are composed of reproduction, crossover and mutation is used to minimize the total energy. Constraints are divided into equalities and inequalities: Equality constraints consist of a position condition at the start and end of a step period and repeatability conditions related to each joint angle and angular velocity. Inequality constraints include collision avoidance conditions of a swing leg at the face and edge of a stair, knee joint conditions with respect to the avoidance of the kinematic singularity, and the zero moment point condition with respect to the stability into the going direction. In order to approximate a gait, each joint angle trajectory is defined as a 4-th order polynomial of which coefficients are chromosomes. The effectiveness of the proposed optimal trajectory is shown in computer simulations with a 6-dof biped robot that consists of seven links in the sagittal plane. The trajectory is more efficient than that generated by the modified GCIPM. And various trajectories generated by the proposed GA method are analyzed in a viewpoint of the consumption energy: walking on even ground, ascending stairs, and descending stairs.

Influence of Malalignment on Tibial Post in Total Knee Replacement Using Posterior Stabilized Implant (슬관절 전치환술에서 후방 안정 임플란트의 오정렬이 경골 기둥에 미치는 영향)

  • Kim, Sang-Hoon;Ahn, Ok-Kyun;Bae, Dae-Kyung;Kim, Yoon-Hyuk;Kim, Kyung-Soo;Lee, Soon-Gul
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.108-116
    • /
    • 2007
  • Recently, it has been reported that the posterior stabilized implant, which is clinically used for the total knee replacement (TKR), may have failure risk such as wear or fracture by the contact pressure and stress on the tibial post. The purpose of this study is to investigate the influence of the mal alignment of the posterior stabilized implant on the tibial post by estimating the distributions of contact pressure and von-Mises stress on a tibial post and to analyze the failure risk of the tibial post. Finite element models of a knee joint and an implant were developed from 1mm slices of CT images and 3D CAD software, respectively. The contact pressure and the von-Mises stress applying on the implant were analyzed by the finite element analysis in the neutral alignment as well as the 8 malalignment cases (3 and 5 degrees of valgus and varus angulations, and 2 and 4 degrees of anterior and posterior tilts). Loading condition at the 40% of one whole gait cycle such as 2000N of compressive load, 25N of anterior-posterior load, and 6.5Nm of torque was applied to the TKR models. Both the maximum contact pressure and the maximum von-Mises stress were concentrated on the anterior-medial region of the tibial post regardless of the malalignment, and their magnitudes increased as the degree of the malalignment increased. From present result, it is shown that the malalignment of the implant can influence on the failure risk of the tibial post.

Immediate Effects of Stretching on Hamstring Stiffness (넙다리뒤근육에 대한 스트레칭이 근육의 뻣뻣함에 미치는 즉각적 효과)

  • Kim, Joong-Hwi;Kim, Tae-Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Purpose: Stretching exercises are commonly used in conjunction with sports and rehabilitation. Weassessed the immediate effects of stretching on passive stiffness of the hamstring muscles and knee range of motion (ROM) using three stretching techniques. Methods: A total of 45 participants were recruited. Isokinetic equipment was used to measure the passive stiffness of hamstring muscles and an inclinometer was used to measure active and passive ROM of the knee joint pre and post stretching. Stiffness was then calculated based on the incline of the torque-angle relationship. The test conditions for Group I were $3{\times}30$ seconds of static stretches using the hamstring muscle, Group II were $3{\times}30$ seconds of static stretches using the hamstring muscle with ankle dorsiflexion, and Group IIII had $3{\times}30$ seconds of active stretching. Results: Group II had significantly higher excursion of active ROM and Group IIIhad significantly higher excursion of passive muscle stiffness. All of the groups had significantly higher active and passive ROM and significantly lower muscle stiffness after stretching. The participants showed no change in hamstring muscle stiffness on the following day. Conclusion: Stretching has significant acute effects on ROM and muscle stiffness and canbe used in warm-up protocols for reducing muscle stiffness before a variety of exercise programs.