• Title/Summary/Keyword: KI

Search Result 60,259, Processing Time 0.092 seconds

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

The Evaluation of Reconstruction Method Using Attenuation Correction Position Shifting in 3D PET/CT (PET/CT 3D 영상에서 감쇠보정 위치 변화 방법을 이용한 영상 재구성법의 평가)

  • Hong, Gun-Chul;Park, Sun-Myung;Jung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.172-176
    • /
    • 2010
  • Purpose: The patients' moves occurred at PET/CT scan will cause the decline of correctness in results by resulting in inconsistency of Attenuation Correction (AC) and effecting on quantitative evaluation. This study has evaluated the utility of reconstruction method using AC position changing method when having inconsistency of AC depending on the position change of emission scan after transmission scan in obtaining PET/CT 3D image. Materials and Methods: We created 1 mL syringe injection space up to ${\pm}2$, 6, 10 cm toward x and y axis based on central point of polystyrene ($20{\times}20110$ cm) into GE Discovery STE16 equipment. After projection of syringe with $^{18}F$-FDG 5 kBq/mL, made an emission by changing the position and obtained the image by using AC depending on the position change. Reconstruction method is an iteration reconstruction method and is applied two times of iteration and 20 of subset, and for every emission data, decay correction depending on time pass is applied. Also, after setting ROI to the position of syringe, compared %Difference (%D) at each position to radioactivity concentrations (kBq/mL) and central point. Results: Radioactivity concentrations of central point of emission scan is 2.30 kBq/mL and is indicated as 1.95, 1.82 and 1.75 kBq/mL, relatively for +x axis, as 2.07, 1.75 and 1.65 kBq/mL for -x axis, as 2.07, 1.87 and 1.90 kBq/mL for +y axis and as 2.17, 1.85 and 1.67 kBq/mL for -y axis. Also, %D is yield as 15, 20, 23% for +x axis, as 9, 23, 28% for -x axis, as 12, 21, 20% for +y axis and as 8, 22, 29% for -y axis. When using AC position changing method, it is indicated as 2.00, 1.95 and 1.80 kBq/mL, relatively for +x axis, as 2.25, 2.15 and 1.90 kBq/mL for -x axis, as 2.07, 1.90 and 1.90 kBq/mL for +y axis, and as 2.10, 2.02, and 1.72 kBq/mL for -y axis. Also, %D is yield as 13, 15, 21% for +x axis, as 2, 6, 17% for -x axis, as 9, 17, 17% for +y axis, and as 8, 12, 25% for -y axis. Conclusion: When in inconsistency of AC, radioactivity concentrations for using AC position changing method increased average of 0.14, 0.03 kBq/mL at x, y axis and %D was improved 6.1, 4.2%. Also, it is indicated that the more far from the central point and the further position from the central point under the features that spatial resolution is lowered, the higher in lowering of radioactivity concentrations. However, since in actual clinic, attenuation degree increases more, it is considered that when in inconsistency, such tolerance will be increased. Therefore, at the lesion of the part where AC is not inconsistent, the tolerance of radioactivity concentrations will be reduced by applying AC position changing method.

  • PDF

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

Current Status of Children Born from Renal Transplanted Mother (신이식을 받은 산모로부터 출생한 소아의 성장상태)

  • Ki Mina;Yook Jinwon;Kim Ji Hong;Kim Pyung-Kil;Moon Jang Il;Kim Soon Il;Kim Yu Seun;Park Kiil;Park Young Won
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.77-83
    • /
    • 2000
  • Purpose: Pregnancy in transplanted mother is considered as a high-risk pregnancy, and significant incidences of prematurity and low-birthweight(LBW) infants have been reported. The objective of this study is to examine the outcome of pregnancy in transplanted mothers and to evaluate the current growth status in their children. Patients and Methods: We retrospectively reviewed 54 pregnancies in 40 kidney recipients until June 1999. Outcomes of pregnancy were reviewed and assessment of the current growth status in children was performed. Results: 54 pregnancies in 40 recipients were identified; 22 ended in termination of pregnancy because of unwanted pregnancy or therapeutic purposes. And of the other 32, 29 livebirths resulted in 28 recipients. The mean age of conception was $30.3{\pm}3.8$ years, with a mean interval from transplantation to conception of $35.9{\pm}23.2$ months. All patients were maintained on immunosuppressive regimens. Incidence of drug-treated hypertension(HTN) prior to pregancy was $52\%$, HTN during pregnancy, $48\%$; preeclampsia, $41\%$; urinary tract infection, $48\%$; oligohydramnios $4\%$; and no rejection during pregnancy and up to 3month post delivery. Of the 29 liveborn infants, prematurity(<37wk) occurred in $52\%$, LBW(<2500g) in $62\%$, VLBW(<1500g) in $7\%$ and $48\%$ born intrauterine growth retardation(IUGR). Mean gestational age was $36.3{\pm}3.0\;wk$; a mean birthweight, $2.23{\pm}0.6\;kg$; a mean birth-height, $45.1{\pm}3.6cm$. Current mean height standard deviation score (height SDS) was $0.29{\pm}0.91$ and mean weight SDS was $0.62{\pm}1.34$. Only one child($4\%$) under 1 year of age was below 10 percentile in height. Most of children had no medical problems except for 4 children; cleft palate(1), tuberous sclerosis(1), essential hematuria(1), and one child expired due to sepsis. Conclusion: This study showed similar incidence of premaure birth($57\%$) and low birth weight infants($62\%$), but lower incidence of spontaneous abortion($5.6\%$) was observed and compared to other studies. Postnatal growth in majority of children($96\%$) achieved catch-up growth before 1 year. Present study supports a more optimistic view of pregnancy in renal transplant mother and normal growth in their children.

  • PDF

Dosimetric Characteristics of Detectors in Measurement of Beam Data for Small Fields of Linear Accelerator (선형가속기의 소조사면에 대한 빔 자료 측정에서 검출기의 선량 특성 분석)

  • Koo, Ki-Lae;Yang, Oh-Nam;Lim, Cheong-Hwan;Choi, Won-Sik;Shin, Seong-Soo;Ahn, Woo-Sang
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.265-273
    • /
    • 2012
  • Aquisition of accurate beam data is very important to calculate a reliable dose distribution of the treatment planning system for small radiation fields in intensity-modulated radiation therapy(IMRT) and stereotactic radiosurgery(SRS). For the measurement of small fields, the choice of a suitable detector is important due to the shape gradient in profile penumbra, the lack of lateral electronic equilibrium, and the effect of effective detector volume. Therefore, this study was to analyze the dosimetric characteristics of various detectors in measurement of beam data for small fields of linear accelerator. 0.01cc and 0.13cc ion chambers (CC01 and CC13) and a stereotactic diode detector(SFD) were used for measurement of small fields. The beam data, including the percent depth dose, output factor, and beam profile were acquired under 6 MV and 15 MV photon beams. Measurements were performed with the field size ranging from $2{\times}2cm^2$ to $5{\times}5cm^2$. For $2{\times}2cm^2$ field size, the differences of the ratios of $PDD_{20}$ and $PDD_{10}$ measured by CC01 and SFD detectors were 1.02% and 0.12% for 6 MV and 15 MV photon beams, respectively. For field sizes larger than $3{\times}3cm^2$, the differences of values of $PDD_{20}/PDD_{10}$ obtained from each detector were 1.15% and 0.71% for 6 MV and 15 MV photon beams, respectively. The output factors obtained from CC01 and SFD for $2{\times}2cm^2$ field size were within 0.5% and 1.5% for 6 MV and 15 MV, respectively. The differences in output factor of three detectors for $3{\times}3cm^2$ to $5{\times}5cm^2$ field sizes were within 0.5%. Profile penumbras measured by the SFD, CC01, and CC13 detectors at three depths were average 2.7 mm and 3.5 mm, 3.4 mm and 4.3 mm, and 5.2 mm and 6.1 mm for 6 MV and 15 MV photon beams, respectively. In conclusion, it could be possible to use of the CC01 and SFD detectors for the measurement of percent depth dose and output factor for $2{\times}2cm^2$ field size, and to use of three detectors for $3{\times}3cm^2$ to $5{\times}5cm^2$ field sizes. CC01 and SFD detectors, consider ably smaller than the radiation field, should be used in order to accurately measure the profile penumbra for small field sizes.

Seasonal Change of Rice-mediated Methane Emission from a Rice Paddy under Different Water Management and Organic Amendments (물 관리와 유기물 시용이 다른 논에서 벼 식물체를 통한 메탄 배출의 계절변화)

  • Shin, Yong-Kwang;Lee, Yang-Soo;Ahn, Jong-Woong;Koh, Mun-Hwan;Eom, Ki-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.1
    • /
    • pp.41-49
    • /
    • 2003
  • Methane emission was measured in a rice paddy under different water management and organic amendments. Methane emission from planted chambers and unplanted chambers was monitored to evaluate the rice-mediated methane emission. In flooding methane emission from planted chambers with NPK, NPK(+P), was $0.174g\;CH_4\;m^{-2}\;d^{-1}$ while that from unplanted chambers with NPK, NPK(-P), was $0.046g\;CH_4\;m^{-2}\;d^{-1}$ Methane emission from planted chambers with rice straw compost amendment, RSC(+P), was $0.214g\;CH_4\;m^{-2}\;d^{-1}$, while that from unplanted chambers with rice straw compost amendment, RSC(-P), was $0.076g\;CH_4\;m^{-2}\;d^{-1}$. Methane emission from planted chambers with rice straw amendment in Fehruary, RS2(+P), was $0.328g\;CH_4\;m^{-2}\;d^{-1}$, while that from unplanted chambers with rice straw amendment in February, RS2(-P), was $0.1g\;CH_4\;m^{-2}\;d^{-1}$. Methane emission from planted chambers with rice straw amendment in May, RS5(+P), was $0.414g\;CH_4\;m^{-2}\;d^{-1}$, while that from unplanted chamhers with rice straw amendment in May, RS5(-P), was $0.187g\;CH_4\;m^{-2}\;d^{-1}$. In intermittent irrigation methane emission from NPK(+P) was $0.115g\;CH_4\;m^{-2}\;d^{-1}$, while that from NPK(-P) was $0.041g\;CH_4\;m^{-2}\;d^{-1}$. Methane emission from RSC(+P) was $0.137g\;CH_4\;m^{-2}\;d^{-1}$, while that from RSC(-P) was $0.06g\;CH_4\;m^{-2}\;d^{-1}$. Methane emission from RS2(+P) was $0.204g\;CH_4\;m^{-2}\;d^{-1}$, while that from RS2(-P) was $0.09g\;CH_4\;m^{-2}\;d^{-1}$. Methane emission from RS5(+P) was $0.273g\;CH_4\;m^{-2}\;d^{-1}$, while that from RS5(-P) was $0.13g\;CH_4\;m^{-2}\;d^{-1}$. Methane transport via rice plant under flooding for NPK plot, RSC plot, RS2 plot and RS5 plot was 73.6%, 64.5%, 69.5% and 54.8%, respectively, and mean was 65.6%. Methane transport via rice plants under intermittent irrigation for NPK plot, RSC plot, RS2 plot and RS5 plot was 64.3%, 59.2%, 55.9% and 52.4%, respectively, and mean was 58.0%.

Results of Total Body Irradiation in Allogeneic Bone Marrow Transplantation for Acute Non-Lymphocytic Leukemia (급성 골수성 백혈병에서 동종골수이식을 위한 전신 방사선 조사의 치료 결과)

  • Chung Su Mi;Choi Ihl Bohng;Kim In Ah;Kim Sung Hwan;Kang Ki Mun;Shinn Kyung Sub;Kim Choon Choo;Kim Dong Jip
    • Radiation Oncology Journal
    • /
    • v.10 no.2
    • /
    • pp.247-253
    • /
    • 1992
  • Between August 1987 and July 1991, 22 patients with acute nonlymphocytic leukemia have received allogeneic bone marrow transplantation (BMT) with non-T-lymphocyte-depleted marrow obtained from matched sibling donors. Of these patients, 12 patients were in first complete remission (CR) and 10 patients in second CR or greater or in relapse. All patients were treated with a preparative regimen consisting of cyclophosphamide (CTX, 60 mg/kg) or combined drugs, and 850 cGy single-dose or $150\~200$ cGy fractionated total body irradiation (TBI) administered twice daily for a total dose of $1200\~1320$ cGy. Survivors have been followed from 8 to 64.5 months (median, 24 months). The overall 2 year survival rate, relapse rate and incidence of radiation pneumonitis and graft versus host disease (GVHD) have been evaluated by age, phase of disease, initial WBC count, modality of TBI or conditioning chemotherapy. Overall 2 year survival was $58{\%}$. The median survival was 31 months and mean survival was 23.2 months. Overall survival have significant impact in patients of age >19 years old (p=0.008), patients in first CR (p=0.09). Two year survival rate is significantly correlated with age ( >19 vs $\leqq$19, $79.4\%$ vs $14.3\%$, p=0.0008), regimen of chemotherapy (CTX vs combined drug, $76.9\%\;vs\;33.3\%$, p=0.04), phase of disease (1st CR vs \geqq2nd$ CR or relapse, $83.3\%\;vs\;30\%$, p=0.01) and method of TBI (fractionated vs single dose, $70.7\%\;vs\;37.5\%$, p=0.05). The influence of French-American-British (FAB) subtypes on relapse rate is not significant, but initial WBC count > 20000/$mm^3$ is associated with increased relapse rate. There is difference in the rate of radiation pneumonitis ($14.3\%\;vs\;25\%$), GVHD ($14.3\%\;vs\;50\%$) and relapse ($21.4\%\;vs\;50\%$) according to fractionated versus single-dose TBI. As mentioned above, fractionated TBI is compatible for the preparative regimen combined with chemotherapy En allogeneic BMT of first CR patients under 41 years of age with suitable donor. Those results from a retrospective, non-randomized study clearly need additional clinical data, ideally from a randomized study.

  • PDF

The 1998, 1999 Patterns of Care Study for Breast Irradiation after Mastectomy in Korea (1998, 1999년도 우리나라에서 시행된 근치적 유방 전절제술 후 방사선치료 현황 조사)

  • Keum,, Ki-Chang;Shim, Su-Jung;Lee, Ik-Jae;Park, Won;Lee, Sang-Wook;Shin, Hyun-Soo;Chung, Eun-Ji;Chie, Eui-Kyu;Kim, Il-Han;Oh, Do-Hoon;Ha, Sung-Whan;Lee, Hyung-Sik;Ahn, Sung-Ja
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: To determine the patterns of evaluation and treatment in patients with breast cancer after mastectomy and treated with radiotherapy. A nationwide study was performed with the goal of improving radiotherapy treatment. $\underline{Materials\;and\;Methods}$: A web- based database system for the Korean Patterns of Care Study (PCS) for 6 common cancers was developed. Randomly selected records of 286 eligible patients treated between 1998 and 1999 from 17 hospitals were reviewed. $\underline{Results}$: The ages of the study patients ranged from 20 to 80 years (median age 44 years). The pathologic T stage by the AJCC was T1 in 9.7% of the cases, T2 in 59.2% of the cases, T3 in 25.6% of the cases, and T4 in 5.3% of the cases. For analysis of nodal involvement, N0 was 7.3%, N1 was 14%, N2 was 38.8%, and N3 was 38.5% of the cases. The AJCC stage was stage I in 0.7% of the cases, stage IIa in 3.8% of the cases, stage IIb in 9.8% of the cases, stage IIIa in 43% of the cases, stage IIIb in 2.8% of the cases, and IIIc in 38.5% of the cases. There were various sequences of chemotherapy and radiotherapy after mastectomy. Mastectomy and chemotherapy followed by radiotherapy was the most commonly performed sequence in 47% of the cases. Mastectomy, chemotherapy, and radiotherapy followed by additional chemotherapy was performed in 35% of the cases, and neoadjuvant chemoradiotherapy was performed in 12.5% of the cases. The radiotherapy volume was chest wall only in 5.6% of the cases. The volume was chest wall and supraclavicular fossa (SCL) in 20.3% of the cases; chest wall, SCL and internal mammary lymph node (IMN) in 27.6% of the cases; chest wall, SCL and posterior axillary lymph node in 25.9% of the cases; chest wall, SCL, IMN, and posterior axillary lymph node in 19.9% of the cases. Two patients received IMN only. The method of chest wall irradiation was tangential field in 57.3% of the cases and electron beam in 42% of the cases. A bolus for the chest wall was used in 54.8% of the tangential field cases and 52.5% of the electron beam cases. The radiation dose to the chest wall was $45{\sim}59.4\;Gy$ (median 50.4 Gy), to the SCL was $45{\sim}59.4\;Gy$ (median 50.4 Gy), and to the PAB was $4.8{\sim}38.8\;Gy$, (median 9 Gy) $\underline{Conclusion}$: Different and various treatment methods were used for radiotherapy of the breast cancer patients after mastectomy in each hospital. Most of treatment methods varied in the irradiation of the chest wall. A separate analysis for the details of radiotherapy planning also needs to be followed and the outcome of treatment is needed in order to evaluate the different processes.

Ecological Characteristics of Local Collections of Cyperus serotinus Rottb. and Their Geographical Differentiation (너도방동산이 지방수집종(地方蒐集種)들의 생태적(生態的) 특성(特性) 및 그의 생리적(生理的) 분화(分化)에 관한 연구(硏究))

  • Seong, Ki-Yeong;Kwon, Yong-Woong
    • Korean Journal of Weed Science
    • /
    • v.3 no.1
    • /
    • pp.14-22
    • /
    • 1983
  • To study ecological characteristics of Cyperus serotinus occuring in Korea its propagules were collected from 6 locations from the northern part to the southern part of Korea (Chuncheon, Suweon, Iri, Jeonju, Gwangju, Milyang) in 1981, cultured and replanted 4 times (May 20, June 5, June 20, July 5) in 1982. They flowered from August 10 to August 29 in the plants planted on May 20 and from August 22 to September 4 in the plants planted on July 5. Plant height, number of tillers and top fresh weight were 85-100cm, 375-1,500 tillers/$m^2$ and 500-1,750g/$m^2$, respectively, when they were planted on May 20, and 58-67cm, 300-625 tillers/ $m^2$ and 125-250g/$m^2$, respectively, when they were planted on July S. Weight of seeds and number of rhizomes per plant were 20-50g/$m^2$ and 20.75-61, respectively, whey, they were planted on May 20, and 5-17.5g/$m^2$ and 51.5-80.25 when they were planted on July 5. Local collections showed. the same morphological characteristics at the level of species identification, but there existed variations among the local collections. Cyperus serotinus from Chuncheon and Suweon were longer in the length of inflorescence, than those from Gwangju and Milyang and rhizomes from Chuncheon and Suweon were thicker than the others. Each of local collections may be regarded as different ecotype based on the above mentioned differences in morphology, growth and flowering response to the planting date. The results appear to imply that Cyperus serotinus weeds occuring in various locations of Korea are different one another in competitive ability with rice crop.

  • PDF