• Title/Summary/Keyword: KI

Search Result 60,278, Processing Time 0.087 seconds

An Ultrastructural Study on the Development of the Knee Joint in the Human Fetus (인태아 슬관절 발육에 관한 전자현미경적 연구)

  • Kim, Baik-Yoon;Joo, Ki-Jung;Nam, Kwang-Il;Yoon, Jae-Rhyong
    • Applied Microscopy
    • /
    • v.30 no.2
    • /
    • pp.213-232
    • /
    • 2000
  • The development of the knee joint was studied by electron microscopy in human fetuses ranging from 20 mm to 260 mm crown-rump length ($7\sim30$ weeks of gestational age). The appearance of the primordium of the meniscus and cruciate ligament was conspicuous as the mesenchymal cells , preceeding that of joint space at 30 mm fetus. The primitive joint cavity was first seen in the interzone from the 40 mm fetus and its intermediate layer proceeded developing as a narrow cleft which was closely incorporated with two chondrogenic layers. Poorly differentiated mesenchymal cells of the meniscus at 40 mm fetus containing predominantly free ribosomes differentiated into fibroblasts at 60 mm fetus. By 100 mm fetus, the fibroblast in inner zone of the meniscus presented as oval profiles with a short cell processes, whereas middle and peripheral zones presented as elongated cells. Differentiation of the synovial membrane coincided with clarification of the joint cavity When dilatation of the synovial cavity occurred, the two types of synovial cells were identified at 60 mm fetus. By 100 mm fetus a majority of the intimal cells were B-type. B-type cells were clearly distinguishable from A-type cells by their content of extensive rough endoplasmic reticula and well developed Golgi complexes. In contrast, A-type cells had numerous filopodia, pinocytotic vesicles, lysosomes and large vacuoles. At 260 mm fetus the B-type cells were also a majority of intimal cells. At 260 mm fetus the inner zone of the meniscus was filled with parallel oriented fascicles of collagenous fibers and oval fibroblasts. The middle zone was constituted of parallel and radially arranged fibers and fibroblasts. The outer zone was populated by elongated fibroblasts encircled by crossed collagenous fibers with the blood vessels. At 30 mm fetus the fibroblasts of the cruciate ligament contained rough endoplasmic reticula and mitochondria. Collagen fibrils were noted within narrow cytoplasmic processes which were continued with the extracellular space. Collagen fibrils of ligament were filled in the bulk of extracellular space at 100 mm fetus. By $150\sim260mm$ fetus, the cruciate ligaments were constituted of longitudinally oriented bundle of collagen fibrils with irregular rows of round cells between.

  • PDF

Morphological Characteristics, and Coefficient of Variation, Heritability and Genetic Advance of Major Cultivars of Spray Chrysanthemum (주요 스프레이 국화 품종의 형태적 특성과 변이계수, 유전율 및 유전자 전이율)

  • Shim, Sung-Im;Lim, Ki-Byung;Kim, Chang-Kil;Chung, Mi-Young;Kim, Kyung-Min;Chung, Jae-Dong
    • Horticultural Science & Technology
    • /
    • v.34 no.2
    • /
    • pp.269-281
    • /
    • 2016
  • The statistical analyses of coefficient of variation, heritability, and genetic advance were carried out to identify differences in morphological characteristics, such as the stem and inflorescence length, of 10 major commercial cultivars of spray chrysanthemum (Chrysanthemum morifolium). For morphological characteristics, stem lengths ranged from 46.4 cm to 54.9 cm, the maximum diameter of stem was 5.6 to 8.5 mm, the hardness of the stem was 0.17 to $0.70kg{\cdot}m^{-2}$, the fresh weight of stem was 7.5 to 17.5 g, the dry weight of the stem was 1.6 to 3.3 g, the ratio of dry weight/fresh weight of stem was 15.9% to 23.1%. Also, the number of leaves on the stem was 8.4 to 12.2, the stem leaf area was 17.8 to $37.8m^2$, the fresh weight stem leaves was 5.3 to 18.6 g, the dry weight was 0.5 to 1.4 g and the ratio of dry weight /fresh weight of stem leaves was 7.6% to 11.5%. The inflorescence length ranged from 10.1 to 18.6 cm, the fresh weight of inflorescence was 7.3 to 26.7 g, the dry weight of inflorescence was 1.2 to 2.8 g, the ratio of dry weight /fresh weight of inflorescence was 10.4% to 17.1%. For flower, the diameter of the flower center was 8.2 to 13.3 mm, the petal width was 5.7 to 14.0 mm, the petal length was 12.9 to 33.1 mm, and the petal thickness was 157.8 to $354.4{\mu}m$. The mean values of each character in each cultivar were very different, and DMRT and LSD values based on morphological characteristics among 10 cultivars were highly significant. For variability and genetic parameters, the lowest CV (coefficient of variation), PCV (phenotypic coefficient of variation), and GCV (genotypic coefficient of variation) were 4.79% to 5.15% in stem length, and the highest variations were 62.97% to 65.21% in leaf area. ECV (error or environmental coefficient of variation) was the lowest for leaf area (1.71%) and it was the highest for leaf dry weight (19.30%). Heritability also significantly differed among the characteristics, ranging from 68.69% to 99.67%, the lowest value was shown in ratio of dry weight /fresh weight of stem and the highest value was for leaf area of stem. The value for genetic advance was the lowest in hardness of stem at 0.30 and the highest in leaf thickness at 156.65. The lowest genetic advance as percentage of mean of stem hardness was 9.17%, while the highest percentage of stem length was 134.27%. Thus the characters which had the highest values indicated above show the influence of additive gene action and may provide useful resources for selection programs for agronomic improvement.

Effects of Application of Fermented Swine Manure with Additional Nitrogen Fertilizer on Productivity of Corn and Leaching of Nitrogen and Phosphorous in Corn Cultivation Soil (돈분발효 퇴액비 시용과 첨가적인 질소비료 시용이 옥수수의 생산성과 질소 및 인의 용탈에 미치는 영향)

  • Choi, Ki-Choon;Jo, Nam-Chul;Jung, Min-Woong;Yook, Wan-Bang
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.30 no.1
    • /
    • pp.15-24
    • /
    • 2010
  • This study was conducted to investigate the effects of swine manure (SM) application with additional nitrogen (N) fertilizer on productivity of corn and environmental pollution in com cultivation soil. The experiment was conformed in lysimeter which was constructed with 30 cm diameter, and 100 cm height. Swine manures used in this study were the compost of swine manure fermented with sawdust (SMFWS) and soft rice hulls treated with high temperature and high pressure (SRH), and swine slurry (SS). The application rates of the additional N, as urea, with swine manure were 50 and 100 kgN/ha on each plot. This study was arranged in completely randomized design with three replication. DM yields in SM treatments with mineral N were increased significantly compared to those in SM treatment without mineral N (zero-mineral N) (P<0.05) and increased as the rate of mineral N application increased (P<0.05). DM yields in SMFWS and SS treatments with mineral 100 kgN/ha showed trends similar to those of chemical fertilizer (control) but higher than those of 50 kg N/ha. DM yields tended to be higher in SMFWS and SS treatments than in SRH treatment. Total N contents in SMFWS, SRH and SS treatments with mineral N were increased, compared with SM treatment without mineral N. N contents in SM treatments with mineral N were lower than those of chemical fertilizer treatment, but N content of chemical fertilizer treatment showed trends similar to that of SS treatments with mineral 100 kgN/ha. $NO_3$-N concentration in SM treatments with mineral N were increased significantly, compared to those in SM treatment without mineral N and in chemical fertilizer (P<0.05). $NH_4$-N concentrations in SMFWS and SS treatments with mineral 100 kgN/ha showed trends similar to those of chemical fertilizer, but higher than those of 50 kg N/ha. $PO_4$-P concentration in SM treatments with mineral N were increased significantly, compared to those in SM treatment without mineral N (P<0.05). $PO_4$-P concentration in chemical fertilizer treatment showed trends similar to that of SS treatments with mineral 100 kgN/ha. The concentrations of $NO_3$-N $NH_4$-N and $PO_4$-P increased as the rate of mineral N application increased (P<0.05). The concentrations of $NO_3$-N $NH_4$-N and $PO_4$-P were highly elevated in the concentrated rainy season in the early stage among experimental period. The maximum $NO_3$-N $NH_4$-N and $PO_4$-P concentrations in the leaching water were 3.46 mg/L, 1.11 mg/L and 0.14 mg/L, respectively.

The Study of Radiation Reducing Method during Injection Radiopharmaceuticals (방사성의약품 투여 시 피폭선량 저감에 대한 연구)

  • Cho, Seok-Won;Jung, Seok;Park, June-Young;Oh, Shin-Hyun;NamKoong, Hyuk;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • Purpose: The whole body bone scan is an examination that visualizing physiological change of bones and using bone-congenial radiopharmaceutical. The patients are intravenous injected radiopharmaceutical which labeled with radioactive isotope ($^{99m}Tc$) emitting 140 keV gammarays and scanned after injection. The 3 principles of radiation protection from external exposureare time, distance and shielding. On the 3 principles of radiation protection basis, radiopharmaceutical might just as well be injected rapidly for reducing radiation because it might be the unopened radiation source. However the radiopharmaceuticals are injected into patient directly and there is a limitation of distance control. This study confirmed the change of radiation exposure as change of distance from radiopharmaceutical and observed the change of radiation exposure afte rsetting a shelter for help to control radio-technician's exposure. Materials & methods: For calculate the average of injection time, the trained injector measured the injection time for 50 times and calculated the average (2 minutes). We made a source as filled the 99mTc-HDP 925 MBq 0.2 mL in a 1 mL syringe and measured the radiation exposure from 50 cm,100 cm,150 cm and 200 cm by using Geiger-Mueller counter (FH-40, Thermo Scientific, USA). Then we settled a lead shielding (lead equivalent 6 mm) from the source 25 cm distance and measured the radiation exposure from 50 cm distance. For verify the reproducibility, the measurement was done among 20 times. The correlation between before and after shielding was verified by using SPSS (ver. 18) as paired t-test. Results: The radiation doses according to distance during 2 minutes from the source without shielding were $1.986{\pm}0.052{\mu}$ Sv in 50 cm, $0.515{\pm}0.022{\mu}$ Sv in 100 cm, $0.251{\pm}0.012{\mu}$ Sv in 150 cm, $0.148{\pm}0.006{\mu}$ Sv in 200 cm. After setting the shielding, the radiation dose was $0.035{\pm}0.003{\mu}$ Sv. Therefore, there was a statistical significant difference between the radiation doses with shielding and without shielding ($p$<0.001). Conclusion: Because the great importance of whole body bone scan in the nuclear medicine, we should make an effort to reduce radiation exposure during radiopharmaceutical injections by referring the principles of radiation protection from external exposure. However there is a limitation of distance for direct injection and time for patients having attenuated tubules. We confirmed the reduction of radiation exposure by increasing distance. In case of setting shield from source 25 cm away, we confirmed reducing of radiation exposure. Therefore it would be better for reducing of radiation exposure to using shield during radiopharmaceutical injection.

  • PDF

The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Ryu, Jae-Kwang;Kim, Seong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose: The multi-gated cardiac blood pool scan is to evaluate the function of left ventricle (LV) and usefully observe a value of ejection fraction (EF) for a patient who is receiving chemotherapy. To calculate LVEF, we should adjust an angle of left anterior oblique (LAO) view to separate both ventricles. And by overlapped ventricles, it is possible to affect LVEF. The purpose of this study is to investigate and compare quantitative indices by changing an angle of LAO view. Materials and methods: We analyzed the 49 patients who were examined by multi-gated cardiac blood pool scan in department of nuclear medicine at Asan Medical Center from June to September 2011. Firstly, we acquired "Best septal" view. And then, we got images by addition and subtraction of angle for LAO view to anterior and lateral. We compared three LAO views for 20 people by 5 degrees and 39 people by 10 degrees. And we analyzed quantitative indices, EF, end diastole and end systole counts, by automated and manual region of interest (ROI) modes. Results: Firstly, we analyzed quantitative indices by automated ROI mode. In case of 5 degrees, the averages of EF are $61.0{\pm}7.5$, $62.1{\pm}7.1$, $60.9{\pm}6.7%$ ($p$=0.841) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $62.4{\pm}9.5$, $62.3{\pm}10.8$, $61.6{\pm}.9.3%$ ($p$=0.938) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Secondly, we analyzed quantitative indices by manual ROI mode. In case of 5 degrees, the averages of EF are $62.8{\pm}7.1$, $63.6{\pm}7.5$, $62.7{\pm}7.3%$ ($p$=0.903) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $65.5{\pm}9.0$, $66.3{\pm}8.7$, $63.5{\pm}.9.3%$ (p=0.473) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Conclusion: When an image is nearly "Best septal" view, the difference of LAO angle would not affect to change LVEF. Although there was no difference in quantitative analysis, deviations could happen when to interpret wall motion qualitatively by reading physicians.

  • PDF

The Evaluation of Difference according to Image Scan Duration in PET Scan using Short Half-Lived Radionuclide (단 반감기 핵종을 이용한 PET 검사 시 영상 획득 시간에 따른 정량성 평가)

  • Hong, Gun-Chul;Cha, Eun-Sun;Kwak, In-Suk;Lee, Hyuk;Park, Hoon;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.102-107
    • /
    • 2012
  • Purpose : Because of the rapid physical decay of the short half-lived radionuclide, counting of event for image is very limited. In this reason, long scan duration is applied for more accurate quantitative analysis in the relatively low sensitive examination. The aim of this study was to evaluate the difference according to scan duration and investigate the resonable scan duration using the radionuclide of 11C and 18F in PET scan. Materials and Methods : 1994-NEMA Phantom was filled with 11C of $30.08{\pm}4.22MBq$ and 18F of $40.08{\pm}8.29MBq$ diluted with distilled water. Dynamic images were acquired 20frames/1minute and static image was acquired for 20minutes with 11C. And dynamic images were acquired 20frames/2.5minutes and static image was acquired for 50minutes with 18F. All of data were applied with same reconstruction method and time decay correction. Region of interest (ROI) was set on the image, maximum radioactivity concentration (maxRC, kBq/mL) was compared. We compared maxRC with acquired dynamic image which was summed one bye one to increase the total scan duration. Results : maxRC over time of 11C was $3.85{\pm}0.45{\sim}5.15{\pm}0.50kBq/mL$ in dynamic image, and static image was $2.15{\pm}0.26kBq/mL$. In case of 18F, the maxRC was $9.09{\pm}0.42{\sim}9.48{\pm}0.31kBq/mL$ in dynamic image and $7.24{\pm}0.14kBq/mL$ in static. In summed image of 11C, as total scan duration was increased to 5, 10, 15, 20minutes, the maxRC were $2.47{\pm}0.4$, $2.22{\pm}0.37$, $2.08{\pm}0.42$, $1.95{\pm}0.55kBq/mL$ respectively. In case of 18F, the total scan duration was increased to 12.5, 25, 37.5, and 50minutes, the maxRC were $7.89{\pm}0.27$, $7.61{\pm}0.23$, $7.36{\pm}0.21$, $7.31{\pm}0.23kBq/mL$. Conclusion : As elapsed time was increased after completion of injection, the maxRC was increased by 33% and 4% in dynamic study of 11C and 18F respectively. Also the total scan duration was increased, the maxRC was reduced by 50% and 20% in summed image of 11C and 18F respectively. The percentage difference of each result is more larger in study using relatively shorter half-lived radionuclide. It appears that the accuracy of decay correction declined not only increment of scan duration but also increment of elapsed time from a starting point of acquisition. In study using 18F, there was no big difference so it's not necessary to consider error of quantitative evaluation according to elapsed time. It's recommended to apply additional decay correction method considering decay correction the error concerning elapsed time or to set the scan duration of static image less than 5minutes corresponding 25% of half life in study using shorter half-lived radionuclide as 11C.

  • PDF

A Study on the Extraction Rate of Brain Tissues from a $^{99m}Tc$-HMPAO Cerebral Blood flow SPECT Examination of a Patient ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰)

  • Kim, Hwa-San;Lee, Dong-Ho;Ahn, Byeong-Pil;Kim, Hyun-Ki;Jung, Jin-Yung;Lee, Hyung-Nam;Kim, Jung-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • Purpose: This study mainly focuses on the patients treated with chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO (d,l-hexamethylpropylene amine oxime) which yielded reduced image quality due to a decreased brain extraction rate. $^{99m}Tc$-HMPAO will be examined further to determine whether this product may be accounted as a factor for this cause. Material and Methods: From January 2010 until December 2010, out of 272 patients who were all subjected to $^{99m}Tc$-HMPAO brain blood flow SPECT scans resulting from Cerebral Infarction; 23 patients(ages $55.3{\pm}9$, 21 males, 3 females) with decreased tissue extraction rate were examined in detail. The radiopharmaceutical product $^{99m}Tc$-HMPAO was used on patients with normal brain tissue exchange rate as well as those with reduced rate in order to prove its' chemical stability. The patients' age, sex, blood pressure, existence of diabetes, drug use, current health status, known side effects from CT/MRI, examination of the patients' past SPECT before/after images were accounted to determine the factors and correlations affecting the rate of blood tissue extractions. Result: After multiple linear regression analysis, there were no unusual correlations between the 6 factors excluding sex, and before/after examination images. Male subjects showed reduced brain tissue extraction rate than the females ($p$ > 0.05) 91.3% male, 8.7% female. Wilcoxon Matched-Pairs Signed-Ranks Test was used on the before/after images which yielded a value of 0.06, which did not indicate a significant amount of difference on the 2 tests ($p$ > 0.05). As a result, the before/after images indicated similar brain tissue extraction rates, and there were variations depending on the individual patient. Conclusion: The effects of the chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO depended on the patient's personal characteristics and status, therefore was considered to be a factor in reducing brain tissue extraction rate. The related articles of $^{99m}Tc$-HMPAO cerebral blood flow SPECT speculates a cerebrovascular disease and factors resulting from portal veins, and it was not possible to pin point the exact cause of decreasing brain tissue extraction rate. However, the $^{99m}Tc$-HMPAO cerebral blood flow SPECT scan proved to be extremely useful in tracking and inspecting brain diseases, as well as offering accurate results from patients suffering from reduced brain tissue extraction rates.

  • PDF

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF