• Title/Summary/Keyword: KEPCO System

Search Result 1,667, Processing Time 0.025 seconds

The Introduction of #2 HVDC SYSTEM (육지-제주간 2차 HVDC SYSTEM 개요)

  • Jang, Suk-Han;Yoo, Sung-Hwan;Shin, Myoung-Sik;Lee, Gyu-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.107-109
    • /
    • 2008
  • Cheju-Haenam HVDC transmission system start it's commercial operation since 1998. JEJU island is supplied with it's about 45% of total electric power from main land with HVDC link. In JEJU island, the demand of electric power is growing every year. With a current power supply, electric power reserve rate will be below the recommended one. For a stable power supply to JEJU island, KEPCO start a construction of #2 HVDC transmission system. This report is for introduction and understanding of #2 HVDC system which will be installed between JEJU island and main land. This report includes a specification of converter station and DC cable. KEPCO expect that this system will solve the power supply problem and maximum wind power plant capacity problem as well.

  • PDF

Surveying a 765kV Transmission Line Using GPS (GPS를 이용한 가공송전선로 측량)

  • Jung, Tay-Ho;Kim, Chang-Ho;Yoon, Young-Soon;Lee, An-Keun;Kim, Jung-Ho;Shin, Tae-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1091-1093
    • /
    • 1999
  • This paper discusses the surveying of a power transmission line using Real Time Kinematic(RTK) GPS technology. The use of RTK provides users with an accurate position at the moment in time. Application result of a 765kV transmission line surveying proved to be more accurate and efficient than using a traditional EDM (Electro-magnetic distance measurement) method. More, decrease in numbers of trees cut down which is a major cause of public discontents was achieved. Improvements in doing a surveying of a power transmission line using GPS is expected in the future.

  • PDF

A Survey on Elements and Characteristics of Seo-DaeGu SVC (서대구 SVC의 기기구성방식 및 특성에 관한 조사)

  • Yoon, Jong-Su;Jang, Byung-Hun;Won, Jong-Ryul;Jeon, Young-Su;Oh, Kwan-Il;Jang, Gil-Su
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.312-314
    • /
    • 1999
  • 한전에서는 1996년 제주-해남간 HVDC 설치에 이어, 1999년 서대구 S/S에 SVC를 설치하였다. 이와 관련하여 본 논문에서는 한전계통에 최초로 설치한 서대구 S/S의 SVC설비운용과 관련하여 SVC의 이론 및 제어기법과 관련된 일반이론을 소개하고, 설치된 SVC의 기기구성방식 및 특성, 제어특성, 기기사양 등에 대해 간략하게 소개하고자 한다. 서대구 SVC는 345kV/13.5kV, 100MVA급으로서 TCR 및 TSC방식의 하이브리드 방식으로 되어 있다.

  • PDF

A Study on Using Large-Scale Energy Storage Systems in Automatic Generation Control Operations of the Energy Management Systems

  • Im, Jihoon;Lim, Gunpyo;Park, Chanwook;Choi, Yohan;Kim, Seunghan;Chang, Byunghoon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.1
    • /
    • pp.121-125
    • /
    • 2016
  • KEPCO has completed the installation and demonstration of a 52 MW battery energy storage system (BESS) for frequency regulation. Especially, 24 MW BESS is for Automatic Generation Control (AGC) in Shin-Yongin substation. Recently, KEPCO Research Institute has operated it connected to EMS of KPX. This paper discussed the operation strategy of EMS through a study on using 24 MW BESS in AGC operation and propose the improvement of AGC target. It is expected that this paper helps a safe and reliable operation and control of ESS for AGC through its continuous update.

The Development of KEPGO Safety Management System (한국전력공사의 안전관리시스템 개발)

  • Park, Soon-Kyu;Kang, Dae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.508-511
    • /
    • 2002
  • This study is for the development of KEPCO Safety Management System. There were so many incidents for ten years in KEPCO. So, KEPCO has been some needs to change in field of safety management. This paper presents introduction of SSM (Systematic Safety Management) of KEPCO that has procedure, checklist, computer program.

  • PDF

Development for Life Assessment System for Pipes of Thermal Power Plants

  • Hyun, Jung-Seob;Heo, Jae-Sil;Kim, Doo-Young;Park, Min-Gyu
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.583-588
    • /
    • 2016
  • The high-temperature steam pipes of thermal power plants are subjected to severe conditions such as creep and fatigue due to the power plant frequently being started up and shut down. To prevent critical pipes from serious damage and possible failure, inspection methods such as computational analysis and online piping displacement monitoring have been developed. However, these methods are limited in that they cannot determine the life consumption rate of a critical pipe precisely. Therefore, we set out to develop a life assessment system, based on a three-dimensional piping displacement monitoring system, which is capable of evaluating the life consumption rate of a critical pipe. This system was installed at the "M" thermal power plant in Malaysia, and was shown to operate well in practice. The results of this study are expected to contribute to the increase safety of piping systems by minimizing stress and extending the actual life of critical piping.

A Study on the Reliability Evaluation of KEPCO Long-term Transmission System (한전의 장기 송전계통 공급신뢰도 평가에 관한 연구)

  • Chu, Jin-Boo;Moon, Ki-Seung;Sin, Sang-Gyoun;Lee, Ki-Seon
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.67-69
    • /
    • 1993
  • The purpose of the facility investment planning for bulk power system is to appropriately configure the power system network to supply the load, which has the supply capability satisfying the probabilistically changing load on the desired reliability level. In order to achieve this purpose, this paper represents the reliability evaluation of the KEPCO's real system with using the MEXICO model, and builds the data base of the power system operation in order to effectively handle the computer model.

  • PDF

Knowledge-based System for Power Generator Annual Maintenance Scheduling (발전기 연간 정기보수계획을 위한 지식 베이스 시스템)

  • Ahn, Byong-Hun;Kim, Chul;Shin, Jae-Yeong;Lee, Kyung-Jae;Kwon, Tae-Won;Lee, Byung-Ha;Ham, Wan-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.47-50
    • /
    • 1991
  • This paper discusses a knowledge-based system being developed by KAIST and KEPCO to assist planning the annual maintenance schedule of power units. To meet users' requirements, we have designed the system with several features: man-machine interaction, catalog system, user-friendliness, the hybrid-system of math-model and knowledge-base. In this paper, we introduce the outline of our system.

  • PDF

The Development of Distribution Power Operating System using the Genetic Algorithm (유전자 알고리즘을 이용한 배전계통 운영시스템 개발)

  • Kim, Joon-Oh;Park, Chang-Ho;Lim, Sung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.480-482
    • /
    • 2000
  • The KEPCO is developing the practical power distribution operating system. The system adopt Genetic Algorithm and will be used loss reduction, load balancing, service planning for large capacity load and various kinds of simulations in the distribution power system. This paper presents the some obstacles and solutions on practical simulation system development, and some problems that need more study.

  • PDF

Analysis of Low Frequency Oscillations in KEPCO System (한전 실계통에서의 저주파 동요현상 해석)

  • Song, K.Y.;Kwon, S.H.;Kim, D.Y.;Kim, Y.J.;Song, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.397-401
    • /
    • 1991
  • Low frequency oscillations have been observed in KEPCO system. This paper represents how to analyze the power system by using the AESOPS program and analyze the various factors affecting the damping characteristics of these oscillations in KEPCO system of 1986. The characteristics of load, the amount of power flow on the transmission line and the gain of exciter have a significant effects on the damping of the system while the governing system has only a minor one. With the Power System Stabilizers, the stability of the power system has been increased.

  • PDF