• 제목/요약/키워드: KEPCO Grid

검색결과 214건 처리시간 0.032초

개폐제어형 초고압차단기의 해외적용사례와 한전계통 적용검토 (Study to Application of Controlled Switching HVAC Circuit Breaker in KEPCO Grid)

  • 오승열;곽주식;정문규;한기선;구선근;주형준;박민혜;김현석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.433-434
    • /
    • 2015
  • Dictionary meaning of circuit-breaker is a mechanical switching device, capable of making, carrying and breaking currents under normal circuit conditions and also making, carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit. and it had been recognized as being operated simultaneously. Controlled Switching System(CSS), which is technology for individual pole operation, are widely used to reduce transient phenomenon, for example switching surges, inrush current, for a all switching cases and nowadays it have become and economical solution for a switching place. The conventional solution to these problem is the use of pre-insertion resistors of $520{\Omega}$. However, it is recognised that the cost for products and maintenance are expensive and this apparatus makes more complex the circuit-breaker mechanism. Korea Electric Power Cooperation (KEPCO) has been study for relevant CCS technology since pilot application in substation in 2003 and plan to apply the actual power grid in 2017. This paper deals with the investigation of international CCS operation status and preview for application in KEPCO power grid.

  • PDF

풍력발전시스템의 배전선로 전압 영향분석 (Distribution Line Voltage Impact Analysis of Wind Power Generation System)

  • 나경윤;고성민;김세호;이수묵;신삼균;김문찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1759-1761
    • /
    • 2005
  • The exploitation of the resource wind energy is a rapidly growing area world-wide. The number of installed units is continuously increasing, and therefore, it is important to respect and to deal with the impact of wind power generation system. From the view of an electric grid utility, there is a major problem with the impact of the wind system on the voltage of the electric grid, to which a turbine in connected. The problem is rather common in the connection of a wind power system to an already existing grid, since the grid is very seldom designed for the transmission of additional power. In this paper, it is investigated the voltage impact of distribution line, to which wind power generation system is connected.

  • PDF

설계목표에 따른 독립형 마이크로그리드 경제성 평가 및 민감도 분석 (An Economic Evaluation and Sensitivity Analysis of Remote MicroGrid According to Design Objectives)

  • 원종남;채우규;이학주;심준보;신창훈
    • 전기학회논문지
    • /
    • 제66권6호
    • /
    • pp.892-897
    • /
    • 2017
  • Until now, it has been for choosing most economic result to be generally used for designing remote MicroGrid (MG) system. It is able to make economic benefit by reducing operation cost, but proportion of renewable energy will be minimum. In other words, it is difficult to get an effect by renewable energy because economic feasibility is an only consideration. Therefore, various factors should be considered and design objectives should be are diversified to design proper remote MG system. In this paper, remote MG system is classified into two types according to design objectives, and they are analysed through case study based on economic evaluation. In addition, economic feasibility for each type is analysed through sensitivity analysis according to various factors that affect the design results of the system.

Static Equivalent Model of Inverter-based Distributed Energy Resource for Fault Analysis of Power Distribution Grid

  • Kim, Dong-Eok;Cho, Namhun;Yang, Seung-Kwon
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.569-575
    • /
    • 2016
  • In this paper, we propose a method to develop a static equivalent model of an inverter-based distributed energy resource (DER), where the model is used for a steady-state fault analysis of a power grid. First, we introduce the characteristics of an inverter-based DER as well as its general configuration. Then, we derive the equivalent model of the DER on the basis of the characteristics. Last, the performance of the proposed method is proven by the results of computer simulations.

KEPCO의 지능형 원격검침 시스템에 대한 연구 (A Study on AMI System of KEPCO)

  • 명노길;김영현;이상염
    • 한국통신학회논문지
    • /
    • 제35권8B호
    • /
    • pp.1251-1258
    • /
    • 2010
  • 단방향 전력망에 정보통신 기술을 접목하여 전력공급자와 소비자가 양방향 실시간 정보를 교환함으로서 에너지 효율을 최적화하는 스마트 그리드의 핵심인 지능형 원격검침 시스템에 대한 연구개발 및 사업화가 전 세계 전력 회사별로 활발히 진행 중에 있다. 본 논문에서는 KEPCO가 대규모 사업화를 추진 중에 있는 지능형 원격검침 시스템의 구성도, 설계된 핵심 단말 및 주요 기능, 관련 통신 기술 및 부가 서비스를 소개하고 기술적 특성과 사업 방향성을 제시하고자 한다.

Lessons Learned from Energy Storage System Demonstrations for Primary Frequency Control

  • Yu, Kwang-myung;Choi, In-kyu;Woo, Joo-hee
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제4권2호
    • /
    • pp.107-114
    • /
    • 2018
  • In recent years, ESS (Energy Storage System) has been widely used in various parts of a power system. Especially, due to its fast response time and high ramp rate, ESS is known to play an important role in regulating grid frequency and providing rotational inertia. As the number of installed and commercially operating ESSs increases, the reliability becomes an important issue. This paper introduces control schemes and presents its test method for grid-connected ESS for primary frequency regulation. The test method allows to verify the control operation in the individual operation mode and state. A validation of the method through actual ESS test in a electrical substation is presented in the case study section.