• Title/Summary/Keyword: KE-T5

Search Result 82, Processing Time 0.03 seconds

Antimutagenicity and Immuno Activity of Extracts from Epimedium koreanum Nakai Containing Different Icariin Quantity (Icariin 함량에 따른 삼지구엽초 추출물의 항돌연변이 및 면역활성)

  • Park, Myoung-Su;Kim, Seo-Jin;Forghani, Fereidoun;Rahman, S.M.E.;Eo, Ji-Hyun;Eun, Jong-Bang;Oh, Deog-Hwan
    • Food Science and Preservation
    • /
    • v.18 no.6
    • /
    • pp.938-945
    • /
    • 2011
  • Epimedium koreanum Nakai is a wild herb commonly consumed in South Korea due to its beneficial health effects. In the present study, the antimutagenic and immunoactivities of extracts from E. koreanum Nakai containing different icariin quantities were investigated for food use. In the Ames test, both the water and ethanol extracts were found not to have a mutagenic effect on Salmonella typhimurium TA98 and TA100, respectively. The E. koreanum Nakai extracts showed over 80 and 90% antimutagenic effects on benzo(${\alpha}$)pyrene (B(a)P) in S. typhimurium TA98 and TA100, respectively. Moreover, all the extracts showed over 70% antimutagenicity on S. typhimurium TA98 and TA100 against 4-nitroquinoline-1-oxide (4NQO). The E. koreanum Nakai extract with ethanol showed strong antimutagenic activity, higher than that of the water extract and the sequenced KE9412, KE9408, and KE9405. In the immunomodulating activity test, the effect of E. koreanum Nakai on the B (Rhamos) and T (Jukat) cells were investigated. The immunoactivity results showed that the growth and viability of the B and T cells increased and were activated more in KE9405 (1.8 times), KE9408 (1.6 times), and KE9412 (1.32 times) in the water extracts, and least in KE9412 (1.74 times), KE9408 (1.52 times), and KE9405 (1.4 times) in the ethanol extracts. In the case of both the water and ethanol extracts ($500{\mu}g/mL$) from E. koreanum Nakai, the highest cell number of the human B (Rhamos) and T (Jukat) cells was observed on day 4 in KE9405 and KE9412, and on day 5 in KE9408. Based on the obtained results, the development of E. koreanum Nakai as a food material is recommended.

Some Characteristics of Teflon-Thermoluminescent Dosimeters (테프론 열형광선량계(熱螢光線量計)의 특성(特性))

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.23-33
    • /
    • 1982
  • The characteristic thermoluminescence responses of Teflon thermoluminescent dosimeters to radiations have been studied by the variation of radiation qualities as well as the high dose radiations. The change in the sensitivity of TLDs for different radiation qualities were studied through not only the photon energy dependence but also the change of supralinearity on the photon energy dependence, by exposing $^{60}Co$ gamma rays, the effective X-rays of 44keV, 69keV, 108keV, and thermal neutron of 0.04 eV. The results were as the following: The TL response of $T-CaSO_4$: Dy as a function of absorbed dose was linear up to about 5 Gy, and the response beyond 5Gy was supralinear for $^{60}Co$ gamma rays. The supralinearity of T-LiF-7 became noticeably apparent more than that of $T-CaSO_4$:Dy and also the lower the LET of radiation became the higher the supralinear effects were. No supralinearity appeared for the thermal neutron irradiations equivalent to 10Gy of $^{60}Co$ gamma rays. The relative sensitivities (Rs), which depended on the doses of $^{60}Co$ gamma rays to the TLDs of T-LiF-7 and T-$CaSO_4$:Dy could be, respectively, approximated to the following empirical formula fitted by the least square method: $$R_{LiF}=1.021-0.04581\;logD+0.402(logD)^2-0.405(logD)^3,\;\;5{\times}10^3{\geq}D{\geq}1(Gy)$$ $$R_{CaSO_4}=0.976-0.3241\;logD+0.262(logD)^2-0.298(logD)^3,\;5{\times}10^3{\geq}D{\geq}1(Gy)$$.

  • PDF

Shielding 140 keV Gamma Ray Evaluation of Dose by Depth According to Thickness of Lead Shield (140 keV 감마선 차폐 시 납 차폐체 두께에 따른 깊이별 선량 평가)

  • Kim, Ji-Young;Lee, Wang-Hui;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.129-134
    • /
    • 2018
  • The present study made a phantom for gamma ray of 140 keV radiated from $^{99m}Tc$, examined shielding effect of lead by thickness of the shielding material, and measured surface dose and depth dose by body depth. The OSL Nano Dot dosimeter was inserted at 0, 3, 15, 40, 90, and 180 mm depths of the phantom, and when there was no shield, 0.2 mm lead shield, 0.5 mm lead shield, The depth dose was measured. Experimental results show that the total cumulative dose of dosimeters with depth is highest at 366.24 uSv without shield and lowest at 94.12 uSv with 0.5 mm lead shield. The shielding effect of 0.2 mm lead shielding was about 30.18% and the shielding effect of 0.5 mm lead shielding was 74.30%, when the total sum of the accumulated doses of radiation dosimeter was 100%. The phantom depth and depth dose measurements showed the highest values at 0 mm depth for all three experiments and the dose decreases as the depth increases. This study proved that the thicker a shielding material, the highest its shielding effect is against gamma ray of 140 keV. However, it was known that shielding material can't completely shield a body from gamma ray; it reached deep part of a human body. Aside from the International Commission on Radiation Units and Measurements (ICRU) recommending depth dose by 10 mm in thickness, a plan is necessary for employees working in department of nuclear medicine where they deal with gamma ray, which is highly penetrable, to measure depth dose by body depth, which can help them manage exposed dose properly.

HPLC Method for the Determination of Nicorandil in Human Plasma

  • Park, Sun-Hee;Shin, In-Chul
    • Biomolecules & Therapeutics
    • /
    • v.16 no.2
    • /
    • pp.168-172
    • /
    • 2008
  • The present study is to determine of sensitive nicorandil analysis method using HPLC and measure the pharmacokinetics parameters (bioavailability, $C_{max}$, $T_{max}$, Ke, $T_{1/2}$) of nicorandil (5 mg, Tab; Choongwae Pharma Corporation). Plasma (500 ul) was mixed with furosemide (internal standard, 500 ug/ml). Detection wavelength was 256 nm. The mixture of 0.01 M ammonium acetate and acetonitrile 80:20 (v/v) was used mobile phase. The HPLC separation was accomplished on ODC reverse HPLC column. The nicorandil was analyzed by a HPLC system, which consists of CAPCELL PAK C18 column (5 ${\mu}$m, 4.6 × 150 mm) and a chromatography data analysis S/W, using a isocratic mobile phase (mixture of 0.01 M ammonium acetate and acetonitrile 80:20 ) at 1.0 ml/min. Its sensitivity, selectivity, accuracy and precision must be adequate for the bioavailabilty study of nicorandil, and the linearity ($r^2$ ≥ 0.9994) of nicorandil was also proved in the range of 0.05 ug/ml . 3 ug/ml. The pharmacokinetic parameters of nicorandil (5 mg) tablets were measured as the follow. AUC: 0.19 ug/ml·hr, $C_{max}$: 0.14 ug/ml, $t_{max}$: 0.58 hr, Ke: 0.11 hr., $t_{1/2\beta}$: 6.76 hrs. This method is simple and sensitive HPLC method using UV detector for determination of nicorandil in human plasma.

A Fast Neutron Time-of-Flight Spectrometer with High Resolution

  • Cho, Mann
    • Nuclear Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.116-131
    • /
    • 1972
  • A fast neutron time-of-flight spectrometer has been constructed with suitable choice of target thickness and proton bombarding energy in Li$^{7}$ (p, n) Be$^{7}$ nuclear reaction for a continuous keV spectrum of neutrons at 0 degree in 1-nsec pulse from a Van do Graaff and a time-pick-up fast neutron detector assembled with a 5 mm-thick 92% enriched B$^{10}$ slab and four heavily shielded 4"$\times$3" NaI scintillation detectors. Energy resolution of this spectrometer is better than 0.3% at 50 keV and the signal-to-background ratio is also improved. Total cross section measurements of several separated single isotopes have been carried out with this spectrometer and analyzed by Rmaxtrix multi-level computer code. The spin values and resonance parameters of each individual resonances are given.

  • PDF

The comparisons of three scatter correction methods using Monte Carlo simulation (몬테카를로 시뮬레이션을 이용한 산란보정 방법들에 대한 비교)

  • 봉정균;김희중;이종두;권수일
    • Progress in Medical Physics
    • /
    • v.10 no.2
    • /
    • pp.73-81
    • /
    • 1999
  • Scatter correction for single photon emission computed tomography (SPECT) plays an important role to improve image quality and quantitation. The purpose of this study was to investigate three scatter correction methods using Monte Carlo simulation. Point source and Jaszack phantom filled with Tc-99m were simulated by Monte Carlo code, SIMIND. For scatter correction, we applied three methods, Compton window (CW) method, triple window (TW) method, and dual photopeak window (DPW) method. Point sources located at various depths along the center line within a 20-cm phantom were simulated to calculate the window ratios and corresponding scatter fractions by evaluating the polynomial coefficients for DPW method. Energy windows were located in W$_1$=92-125 keV, W$_2$=124-126 keV, W$_3$=136-140 keV, W$_4$=140-141 keV, and W$_{5}$=154-156 keV. The results showed that in Jaszack phantom with cold sphere and hot sphere, the TW gave the closest contrast and percentage recovery to the ideal image, respectively, while CW overestimated and DPW underestimated the contrast of ideal one. All three scatter correction methods showed an improved image contrast. In conclusion, scatter correction is essential for improving image contrast and accurate quantification. The choice of scatter correction method should be made on the basis of accuracies and ease of implementation.

  • PDF

Scintillation Characteristics of CsI(Li) Single Crystals (CsI(Li) 단결정의 섬광특성)

  • Lee, W.G.;Doh, S.H.;Ro, T.I.;Kim, W.;Kang, H.D.;Moon, B.S.
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.359-367
    • /
    • 1999
  • CsI(Li) single crystals doped with 0.02, 0.1, 0.2 and 0.3 mole% lithium as an activator were grown by Czochralski method. The lattice structure of grown CsI(Li) single crystal was bcc, its lattice constant was $4.568\;{\AA}$. The absorption edge of CsI(Li) single crystal was 245 nm, and the spectral range of luminescence was $300{\sim}600\;nm$, its maximum luminescence intensity appeared at 425 nm. The energy resolutions of CsI(Li) single crystal doped with 0.2 mole% lithium were 14.5% for $^{137}Cs$(662 keV), 11.4% for $^{54}Mn$(835 keV) and 17.7% and 7.9% for $^{22}Na$(511 keV and 1275 keV), respectively. The relation formula of $\gamma$-ray energy versus energy resolution was ln (FWHM%) = -0.893lnE + 8.456 and energy calibration formula was ${\log}E_r=1.455\;{\log}(ch.)-1.277$. The phosphorescence decay time of CsI(Li) crystal doped with 0.2 mole% lithium was 0.51 s at room temperature, and its time resolution measured by CFT(constant-fraction timing method) was 9.0 ns.

  • PDF

Virtual Monochromatic Image Quality from Dual-Layer Dual-Energy Computed Tomography for Detecting Brain Tumors

  • Shota Tanoue;Takeshi Nakaura;Yasunori Nagayama;Hiroyuki Uetani;Osamu Ikeda;Yasuyuki Yamashita
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.951-958
    • /
    • 2021
  • Objective: To evaluate the usefulness of virtual monochromatic images (VMIs) obtained using dual-layer dual-energy CT (DL-DECT) for evaluating brain tumors. Materials and Methods: This retrospective study included 32 patients with brain tumors who had undergone non-contrast head CT using DL-DECT. Among them, 15 had glioblastoma (GBM), 7 had malignant lymphoma, 5 had high-grade glioma other than GBM, 3 had low-grade glioma, and 2 had metastatic tumors. Conventional polychromatic images and VMIs (40-200 keV at 10 keV intervals) were generated. We compared CT attenuation, image noise, contrast, and contrast-to-noise ratio (CNR) between tumor and white matter (WM) or grey matter (GM) between VMIs showing the highest CNR (optimized VMI) and conventional CT images using the paired t test. Two radiologists subjectively assessed the contrast, margin, noise, artifact, and diagnostic confidence of optimized VMIs and conventional images on a 4-point scale. Results: The image noise of VMIs at all energy levels tested was significantly lower than that of conventional CT images (p < 0.05). The 40-keV VMIs yielded the best CNR. Furthermore, both contrast and CNR between the tumor and WM were significantly higher in the 40 keV images than in the conventional CT images (p < 0.001); however, the contrast and CNR between tumor and GM were not significantly different (p = 0.47 and p = 0.31, respectively). The subjective scores assigned to contrast, margin, and diagnostic confidence were significantly higher for 40 keV images than for conventional CT images (p < 0.01). Conclusion: In head CT for patients with brain tumors, compared with conventional CT images, 40 keV VMIs from DL-DECT yielded superior tumor contrast and diagnostic confidence, especially for brain tumors located in the WM.

X-RAY PROPERTIES OF THE PULSAR PSR J0205+6449 IN 3C 58

  • Kim, Minjun;An, Hongjun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.53.2-53.2
    • /
    • 2020
  • We measure X-ray timing and spectral properties of the pulsar PSR J0205+6449. Pulsar's rotation frequency ν = 15.20102357(9) s-1 and its derivative ${\dot{\nu}}=-4.5(1){\times}10^{-11}s^{-2}$ are measured, and the pulsed spectrum of 2-30 keV is model of power law with photon index ��psr = 1.07(16) and F2-30 keV = 7.3(6) × 10-13 erg cm-2 s-1. We use thermal emission models and non-thermal model to fit the pulsar spectrum and measure the surface temperature and luminosity of the pulsar. The surface temperature T∞ = 0.5-0.8 MK and luminosity Lth = 1-5 × 1032 erg s-1 are measure, and this result verifies the previous results known to have low surface temperature and luminosity for the age range of

  • PDF

Effect of keratinase on ileal amino acid digestibility in five feedstuffs fed to growing pigs

  • Huang, Chengfei;Ma, Dongli;Zang, Jianjun;Zhang, Bo;Sun, Brian;Liu, Ling;Zhang, Shuai
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.12
    • /
    • pp.1946-1955
    • /
    • 2018
  • Objective: This study was conducted to evaluate the effect of keratinase (KE) on the apparent ileal digestibility (AID) and standardized ileal digestibility (SID) of amino acids (AA) in rice bran, cottonseed meal (CSM), rapeseed meal (RSM), corn distillers dried grains with solubles (DDGS), and peanut meal (PNM). Methods: Twelve crossbred barrows (Duroc${\times}$Landrace${\times}$Yorkshire, $50.5{\pm}1.4kg$ body weight [BW]) fitted with T-cannulas at the terminal ileum were allotted to a $12{\times}6$ Youden Square design with 12 diets and 6 periods. The treatment diets included rice bran, CSM, RSM, corn DDGS, PNM, or corn-soybean meal (cSBM) supplemented with 0.05% KE or not. Diets were given to pigs at a level of 3% BW in two equal meals. The endogenous AA losses were the mean results of three previously experiments determined by a same nitrogen-free diet fed to pigs. Pigs had free access to water during the experiment. Results: The KE supplementation improved (p<0.05) the AID and SID of Met, Thr, Val, Asp, Cys, and Tyr in rice bran. Inclusion of KE increased (p<0.05) the AID and SID of Met and Val in CSM. The KE supplementation decreased (p<0.05) the AID and SID of His in RSM and all measured AA except for Arg, Met, Trp, Val, Gly, and Pro in corn DDGS. There was an increase (p<0.05) in AID and SID of Leu, Ile, Met, Ala, Cys, Ser, and Tyr in PNM supplemented with KE compared with that without KE. Inclusion of KE increased (p<0.05) the AID and SID of crude protein, Leu, Ile, Phe, Thr, Asp, and Ser in cSBM. Conclusion: This study indicated that KE had different effects on ileal AA digestibility of feedstuffs for growing pigs, which can give some usage directions of KE in swine feed containing those detected feedstuffs.