• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.065 seconds

An Implementation of Security System Using Speaker Recognition Algorithm (화자인식 알고리즘을 이용한 보안 시스템 구축)

  • Shin, You-Shik;Park, Kee-Young;Kim, Chong-Kyo
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.4
    • /
    • pp.17-23
    • /
    • 1999
  • This paper described a security system using text-independent speaker recognition algorithm. Security system is based on PIC16F84 and sound card. Speaker recognition algorithm applied a k-means based model and weighted cepstrum for speech features. As the experimental results, recognition rate of the training data is 100%, non-training data is 99%. Also false rejection rate is 1%, false acceptance rate is 0% and verification mean error rate is 0.5% for registered 5 persons.

  • PDF

A Novel Hybrid Supercapacitor Using a Graphite Cathode and a Niobium(V) Oxide Anode

  • Park, Gum-Jae;Kalpana, D.;Thapa, Arjun Kumar;Nakamura, Hiroyoshi;Lee, Yun-Sung;Yoshio, Masaki
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.817-820
    • /
    • 2009
  • To meet the high current load requirement from the high energy density realized by metal oxide and high power density graphite, we propose a novel hybrid supercapacitor consisting of Nb2O5 and KS6 graphite in 1.0 M LiPF6-EC:DEC (1:2). This new system exhibits a sloping voltage profile from 2.7 to 3.5 V during charging and presents a high operating voltage plateau between 1.5 and 3.5 V during discharging. The cell was tested at a current density of 100 mA/g with a cut-off voltage between 3.0 and 1.0 V. This novel energy storage system delivers the highest initial discharge capacity of 55 mAh/g and exhibits a good cycle performance.

An Advanced Fault Diagnosis System

  • Park, Young-Moon;Ahn, Bok-Shin;Lee, Heung-Jae
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.5
    • /
    • pp.45-50
    • /
    • 1997
  • This paper present an advanced fault diagnosis expert system to assist the operators at local control center. The system utilizes all th information available in a local control center for the better diagnostic performance. The major feature of the system is dealing with multiple faults diagnosis based on the certainty factor method for the reasoning process. the overall performance and the generality are also enhanced by utilizing the general topological knowledge. ASCADA simulator is also developed for he test and demonstration.

  • PDF

Projection of 21st Century Climate over Korean Peninsula: Temperature and Precipitation Simulated by WRFV3.4 Based on RCP4.5 and 8.5 Scenarios (21세기 한반도 기후변화 전망: WRF를 이용한 RCP 4.5와 8.5 시나리오 기온과 강수)

  • Ahn, Joong-Bae;Choi, Yeon-Woo;Jo, Sera;Hong, Ja-Young
    • Atmosphere
    • /
    • v.24 no.4
    • /
    • pp.541-554
    • /
    • 2014
  • Historical, RCP4.5 and RCP8.5 scenarios from HadGEM2-AO are dynamically downscaled over the northeast East Asia with WRFV3.4. The horizontal resolution of the produced data is 12.5 km and the periods of integration are 1979~2010 for historical and 2019~2100 for both RCP4.5 and RCP8.5. We analyze the time series, climatology, EOF and extreme climate in terms of 2 m-temperature and precipitation during 30-year for the Historical (1981~2010) and RCP4.5 and RCP8.5 (2071~2100) scenarios. According to the result, the temperature of the northeast Asia centered at the Korean Peninsula increase 2.9 and $4.6^{\circ}C$ in the RCP4.5 and RCP8.5 scenarios, respectively, by the end of the 21st century. The temperature increases with latitude and the increase is larger in winter rather than in summer. The annual mean precipitation is expected to increase by about $0.3mm\;day^{-1}$ in RCP4.5 scenario and $0.5mm\;day^{-1}$ in RCP8.5 scenario. The EOF analysis is also performed for both temperature and precipitation. For temperature, the EOF $1^{st}$ modes of all scenarios in summer and winter show that temperature increase with latitude. The $2^{nd}$ mode of EOF of each scenario shows the natural variability, exclusive of the global warming. The summer precipitation over the Korean Peninsula projected increases in EOF $1^{st}$ modes of all scenarios. For extreme climate, the increment of the number of days with daily maximum temperature above $30^{\circ}C$ per year ($DAY_{TX30}$) is 25.3 and 49.7 days in RCP4.5 and RCP8.5 respectively over the Korean Peninsula. The number of days with daily precipitation above $20mm\;day^{-1}$ per year ($DAY_{PR20}$) also increases 3.1 and 3.5 days in RCP4.5 and RCP8.5 respectively.

Dust Collection Characteristics of Multi-layer Multi-stage Porous Plate System with Polarization Charge to Impaction Effect (임팩션 효과에 편극전하 방식을 부가한 다층 다단 다공성 플레이트 시스템의 집진특성)

  • Kim, Bo-Bae;Kim, Il-Kyu;Yoa, Seok-Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.8
    • /
    • pp.598-605
    • /
    • 2011
  • The main object of this study is to investigate the Dust Collection Characteristics of multi-layer multi-stage porous plate system with polarization charging mechanism, experimentally. The experiment is carried to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as applied voltage, inlet velocity, inlet concentration and stage number, etc. In results, the pressure drop becomes 18 to $134mmH_2O$, with increment of stage number (1 to 5) at inlet velocity $v_{in}$ = 3.11 m/s ($v_t$ = 18 m/s) and inlet concentration 3 g/m3 for inflow current. In case of both applied voltage 0 kV and non-inflow current, the collection efficiency of 5 stage is 92.5% at $v_{in}$ = 2.58 m/s ($v_t$ = 15 m/s), while it is estimated that the collection efficiency becomes about 6% higher than that of 0 kV and non-inflow as 98.5% at $v_{in}$ = 2.58 m/s for both alternating polarization charge (applied voltage 2.5 kV) and inflow current system.

Evidence-Based Clinical Practice Guideline for Fluid Therapy to Prevent Contrast-induced Nephropathy (조영제 유발 신장병증 예방을 위한 수액요법에 관한 근거기반 임상실무지침 개발)

  • Lee, Kyung Hae;Shin, Kyung Min;Lee, Hyeon Jeong;Kim, So Young;Chae, Jung Won;Kim, Mi Ra;Han, Min Young;Ahn, Mi Sook;Park, Jin Kyung;Chung, Mi Ae;Chu, Sang Hui;Hwang, Jung Hwa
    • Journal of Korean Clinical Nursing Research
    • /
    • v.23 no.1
    • /
    • pp.83-90
    • /
    • 2017
  • Purpose: This study was to develop evidence-based clinical practice guideline in order to prevent contrastinduced nephropathy (CIN) for patients undergoing percutaneous coronary intervention (PCI). Methods: The guideline was developed based on the "Scottish Intercollegiate Guidelines Network (SIGN)". The first draft of guideline was developed through 5 stages and evaluated by 10 experts.(1) Clinical questions were ensured in PICO format.(2) Two researchers conducted a systematic search through electronic database, identifying 170 studies. We selected 27 full text articles including 16 randomized clinical trials, 7 systematic reviews, and 4 guidelines. Quality of each studies were evaluated by the Cochran's Risk of Bias, AMSTAR, K-AGREEII. Among the studies, 11 studies were excluded.(3) The strength of recommendations were classified and quality of recommendations were ranked.(4) Guideline draft was finalized.(5) Content-validation was conducted by an expert group. All contents were ranked above 0.8 in CVI. Results: Evidence-based clinical practice guideline to prevent CIN was dveloped.(1) The guideline for preventing CIN recommends using 0.9% saline.(2) Standardized rate of fluid therapy is 1 to 1.5ml/kg/hr.(3) Execute hydration for 6~12hrs before PCI and after PCI. Conclusion: This study suggests evidence-based clinical practice guideline for preventing CIN which can be more efficiently used in clinical practice.

Study on HV Nano-second Pulse Electron Gun System (고전압 Nano-second펄스 전자총에 관한 연구)

  • Son, Y.K.;Park, S.J.;Jang, S.D.;Oh, J.S.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1391-1393
    • /
    • 1995
  • An electron gun system for the Pohang Light Source has been installed and operated successfully. The basic design parameters are acceleration voltage of 80 kV, maximum peak emission current of 5 A, minimum pulse width of 1 ns, and maximum repetition rate of 100 Hz. The gun has a triode structure and is composed of a cathode, a focusing electrode(Wehnelt), and an anode. To sustain a $5{\times}10^{-9}$Torr vacuum, a $230{\ell}/s$ Ion pump has been adopted. We adopted a control and monitoring system based on the fiber-optic technology. In this article, we present the structure and operation principle of the system with special interest on the nanosecond pulser, remote control and monitoring system.

  • PDF

Decentralized Neural Network-based Excitation Control of Large-scale Power Systems

  • Liu, Wenxin;Sarangapani, Jagannathan;Venayagamoorthy, Ganesh K.;Liu, Li;Wunsch II, Donald C.;Crow, Mariesa L.;Cartes, David A.
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.5
    • /
    • pp.526-538
    • /
    • 2007
  • This paper presents a neural network based decentralized excitation controller design for large-scale power systems. The proposed controller design considers not only the dynamics of generators but also the algebraic constraints of the power flow equations. The control signals are calculated using only local signals. The transient stability and the coordination of the subsystem control activities are guaranteed through rigorous stability analysis. Neural networks in the controller design are used to approximate the unknown/imprecise dynamics of the local power system and the interconnections. All signals in the closed loop system are guaranteed to be uniformly ultimately bounded. To evaluate its performance, the proposed controller design is compared with conventional controllers optimized using particle swarm optimization. Simulations with a three-machine power system under different disturbances demonstrate the effectiveness of the proposed controller design.

The Korea Academia-industrial cooperation Society (상용 트럭의 공압 브레이크 응답 특성에 관한 연구)

  • Kim, Jin-Taek;Jung, Do-Gyun;Choi, Pan-Jin;Park, Won-Ki;Park, Chan-Hee;Ryuh, Beom-Sahng;Baek, Byung-Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.1969-1975
    • /
    • 2012
  • The air brake system used in heavy vehicle is very important from the point of safety due to its weight. In general, air brake system generates relatively long response time and large loss of pressure. It is known that the response time can be decreased by optimal design of brake system, i.e., by increasing the system pressure, minimizing the air line, and material of components. In this study, We developed experimental rigs for the measurement of braking response of heavy duty trucks and compared with the simulated results obtained from the net work fluid flow system analysis code (FLOWMASTER). The effect of several parameters such as, system pressure, diameter of pipe, chamber temperature on the brake response performance have been examined.

Combination System Design of 5G Candidate Modulation and Full Duplex Communication for the Spectrum Efficiency Enhancement (스펙트럼 효율 향상을 위한 전이중 통신 방식과 5G 후보 변조기술과의 결합시스템 설계)

  • An, Changyoung;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.4
    • /
    • pp.369-376
    • /
    • 2016
  • In this paper, we propose and design a SSD(Simultaneous Single band Duplex) system using 5G(Generation) candidate modulations. Especially, we consider HPA(High Power Amplifier) nonlinearity in the proposed system. And then, we evaluate and analyze performance of the proposed system. As simulation results, performance of SSD-OFDM(Orthogonal Frequency Division Multiplexing), SSD-FMC (Universal Filtered Multi-Carrier), and SSD-FBMC(Filter Bank Multi-Carrier) is severely degraded by HPA nonlinearity. However, performance of SSD-OFDM, SSD-UFMC, and SSD-FBMC is similar in the same condition. That is, OFDM, UFMC, and FBMC have a similar PAPR(Peak to Average Power Ratio) characteristic. Finally, we can confirm that the proposed SSD system can not cancel(SI) self-interference effectively by strong HPA nonlinearity. That is, Reducing PAPR is important in order to avoid effect of HPA nonlinearity in the proposed SSD system.