• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.059 seconds

Study on Manufacturing and Characteristics of Phase Change Materials for Having Latent Heat (열저장 물질로써 잠열재의 제조 및 특성 연구)

  • Kwon K.H.;Jeong J.W.;Choi C.H.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.3 s.116
    • /
    • pp.168-174
    • /
    • 2006
  • The purpose of this study is to develop the cold chain system by developing optimal phase change materials (PCM). There are some benefits from developing this system such as keeping freshness of agriculture products, saving energy, etc. The major results are as follows. To decide a latent heat material, the characteristics of water, sodium, polyacrylate, ethanol and N-tetradecane are analysed. Also, an insulating material is made by mixing water, nucleating agent and latent heat material, using cementing method. In addition, the sensitivity analysis for developed latent heat material($K_l,\;K_2,\;K_3$) is conducted. For $K_l,\;K_2,\;K_3$ which cans keep latent heat temperature, ranging from $0\;to\;5^{\circ}C,\;5\;to\;10^{\circ}C,\;10\;to\;15^{\circ}C$. it can keeps latent heat temperature at radiant heat (5, 12, $17^{\circ}C$) and transportation latent heat container both melting temperature and amount of latent heat of Kl are $-1.6{\pm}1.0^{\circ}C$, 326.51 J/g, respectively and freezing temperature and latent heat are $-7.98{\pm}1.5^{\circ}C$ and 174.18 J/g. and $K_2$ are $7.41{\pm}1.5^{\circ}C$, 89.80 J/g, respectively and freezing temperature and latent heat are $-2.14{\pm}1.5^{\circ}C$ and 83.90 J/g. and $K_3$ are $9.54{\pm}1.0^{\circ}C$, 145.42 J/g, respectively and freezing temperature and latent heat are $0.21{\pm}1.0^{\circ}C$ and 152.48 J/g.

Concentration and Properties of Particulate Matters (PM10 and PM2.5) in the Seoul Metropolitan (서울시 지하철 시스템 내의 입자상물질(PM10, PM2.5) 농도 특성)

  • Lee, Tae-Jung;Lim, Hyoji;Kim, Shin-Do;Park, Duck-Shin;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.164-172
    • /
    • 2015
  • Seoul subway plays an important part for the public transportation service in Seoul metropolitan area. As the subway system is typically a closed environment, frequent air pollution problems occurred and passengers get malhealth impact. Especially particulate matters (PM) is well known as one of the major pollutants in subway environments. The purpose of this study was to compare the concentrations of $PM_{10}$ and $PM_{2.5}$ in the Seoul subway system and to provide fundamental data in order to management of subway system. $PM_{10}$ and $PM_{2.5}$ samples were collected in the M station platform and tunnel of Subway Line 4 in Seoul metropolitan and in an outdoor location close to it from Apr. 21, 2010~Oct. 27, 2013. The samples collected on teflon filters using $PM_{10}$ and $PM_{2.5}$ mini-volume portable samplers and PM sequential sampler. The PM contributions were $48.6{\mu}g/m^3$ (outdoor), $84.6{\mu}g/m^3$ (platform) and $204.8{\mu}g/m^3$ (tunnel) for $PM_{10}$, and $34.6{\mu}g/m^3$ (outdoor), $49.7{\mu}g/m^3$ (platform) and $83.1{\mu}g/m^3$ (tunnel) for $PM_{2.5}$. The $PM_{10}$ levels inside stations and outdoors are poorly correlated, indicating that $PM_{10}$ levels in the metro system are mainly influenced by internal sources. In this study, we compared PM concentrations before and after operation of ventilation and Electrostatic Precipitator (EP). Despite the increased PM concentration at outdoor, $PM_{10}$ concentration at platform and tunnel showed the 31.2% and 32.3% reduction efficiency after operation the reduction system. The overall results of this study suggest that the installation and operation of the ventilating system and EP should have served as one of the important components for maintaining the air quality in the subway system.

A CFD Study on Unsteady and Steady State of the Hydrogen Leakage for Residential Fuel Cell System (가정용 연료전지 시스템 내부 수소 누출의 비정상 및 정상 상태에 관한 전산 해석)

  • Chung, Tae-Yong;Ahn, Jae-Uk;Nam, Jin-Hyun;Shin, Dong-Hoon;Kim, Young-Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.4
    • /
    • pp.41-46
    • /
    • 2007
  • The residential fuel cell system was modeled as a box-shaped chamber with vent openings, filled with various components such as reformer, desulfurizer, fuel cell stack and humidifier. When the vent openings are 1% of the total surface and hydrogen leakage 1%, hydrogen concentration is around 0.1% higher than the other regions from leak points in the chamber at 30 seconds and hydrogen concentration is increased from 0.3% to 0.7% in the upper region of the system after 200 seconds. When the vent openings are 1% of the total surface and hydrogen leakage 1%, 3%, 5%, the steady state result of CFD, 5% of hydrogen leakage is reached the lowest ignition limit in the system. When the vent openings are 2% of the total surface and hydrogen leakage 1%, hydrogen concentration is increased in the bottom of the system for 60 seconds. After 250 seconds, hydrogen concentration is reached the steady state in the system. As the vent opening of the total surface increased from 1% to 2%, averaged hydrogen mole fraction is under 1% in the system, however, upper regions of the system from the hydrogen leakage points are shown over 1% of hydrogen mole fraction.

  • PDF

The Effects of distilled Wild Ginseng Herbal Acupuncture on the Heart Rate Variability(HRV) (산삼 약침이 정상인의 심박변이도(HRV)에 미치는 영향)

  • Roh, Jeong-Du;Kim, Lak-Hyung;Song, Beom-Yong;Yook, Tae-Han
    • Journal of Pharmacopuncture
    • /
    • v.11 no.1
    • /
    • pp.55-69
    • /
    • 2008
  • Objective : We investigated the effects of distilled Wild Ginseng Herbal Acupuncture on autonomic nervous system with the Heart Rate Variability(HRV) in adult man. as well as we tried to observe how distilled Wild Ginseng Herbal Acupuncture on the balance of the autonomic nervous system. Method : We investigated the effects of distilled Wild Ginseng Herbal Acupuncture on autonomic nervous system with the Heart Rate Variability(HRV) in adult man. as well as we tried to observe how distilled Wild Ginseng Herbal Acupuncture on the balance of the autonomic nervous system. 1 healthy volunteers consisted of 31 subjects in experiment(distilled Wild Ginseng Herbal Acupuncture) group and 30 subjects in control(Normal Saline) group. Study form was a randomized, placebo-controlled, double-blind clinical trial. 31 subjects in experiment group were injected distilled Wild Ginseng Herbal Acupuncture at $GB_{21}$(Kyonjong) and 30 subjects in control group were injected Normal Saline at $GB_{21}$(Kyonjong). except of 2 subjects(in control group) who can't be measured and 11 subjects(7 in experiment group and 4 in control group) who move or make unforceable error during measuring. Finally 24 subject in experiment group and 24 subject in control group are studied. We measured HRV by PolyG-I on 7 times : before and after injection per 5 minutes during 30 minutes. The SPSS 10.0 for windows was used to analyze the data and the paired t-test(in group) and Student t-test(between two groups) were used to verify the result. Result : 1. After distilled Wild Ginseng Herbal Acupuncture injection, Mean HRV is significantly low only for first 5 minute, SDNN is significantly high after 5 minute, Complexity is significantly low after 5 minute, HRV index is significantly high after 10 minute and pNN50 is significantly low after 5 minute. 2. SDNN of distilled Wild Ginseng Herbal Acupuncture Group significantly increased from 20minute to 25minute, and pNN50 of distilled Wild Ginseng Herbal Acupuncture Group significantly decreased from 10minute to 15minute and 20 minute to 30 minute compared with those of Normal Saline group. 3. After distilled Wild Ginseng Herbal Acupuncture injection, Ln(TP), Ln(VLF) and Ln(LF) are significantly high after 5 minute, normalized LF is significantly high after 5 minute and normalized HF is significantly low after 5 minute. 4. Ln(TP) and Ln(VLF) of distilled Wild Ginseng Herbal Acupuncture Group significantly increased from 20minute to 25 minute compared with those of Normal Saline group. Conclusion : The results suggest that distilled Wild Ginseng Herbal Acupuncture in healthy adult man tend to activate the autonomic nervous system and sympathetic nervous system compared to Normal Saline within normal range.

New Sizing System Development of Korean Male Military Winter Jacket (한국 남자 군인 방한복의 신 치수체계 개발)

  • Han, Hyunsook;Han, Hyunjung;Cho, Jayoung;Jung, Kihyo;Kim, Beomjoon;Koh, Joonseok;Park, Changkyu
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.5
    • /
    • pp.954-965
    • /
    • 2016
  • This study was designed to help develop an optimized sizing system for the military winter jackets of Korean males. First, we conducted a survey on the supply rate of military winter jackets and the wearing of suitable size jackets in order to identify problems in the current sizing system. We next developed a new sizing system generation method to satisfy the coverage rate and appropriate size number: Hybrid of Grid with Optimization. The findings of this study were: 1. The survey indicated that a 90 (chest girth) size is necessary; in addition, a one-step large size jacket fit well as a right size jacket. 2. We developed three optimized sizing systems for Korean male military winter jackets using the Hybrid of Grid with an optimization method and suggested one of them as a final new sizing system. The new sizing system consisted of two primary dimension: chest girth and stature. It has a 14 size number and its extended coverage rate is larger than the current sizing system and it has a 90 (chest girth) size. It also selected an optimized size for the area of low population density. The new sizing system is therefore considered very effective for Korean male soldiers military winter jackets.

USING LOW-VOLTAGE-HIGH-FREQUENCY ELECTRIC FIELD TO MITIGATE MINERAL FOULING IN A HEAT EXCHANGER

  • Tijing, Leonard D.;Pak, Bock-Choon;Baek, Byung-Joon;Lee, Dong-Hwan;Cho, Young-I.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2315-2320
    • /
    • 2007
  • This paper presents an investigative study on the efficacy of a new physical water treatment (PWT) technology using an oscillating electric field to mitigate mineral fouling in heat exchangers. Parallel graphite electrode plates immersed in water were used to generate the electric field directly in water. Artificial hard water at 500 ppm hardness was used in all fouling tests. The inlet temperatures were maintained at 23.5${\pm}$0.5$^{\circ}C$ and 85${\pm}$0.5$^{\circ}C$ for cold and hot water sides, respectively. The results at a cold water-side velocity of 0.3 m/s showed a 16-60% drop in fouling resistances from the baseline test depending on the frequency of the electric field for the PWT-treated cases.

  • PDF

Safety Improvement Test of a GNSS-based AGV (위성항법 기반 AGV의 안전성 향상 시험)

  • Kang, Woo-Yong;Lee, Eun-Sung;Han, Ji-Ae;Heo, Moon-Beom;Nam, Gi-Wook
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.5
    • /
    • pp.648-654
    • /
    • 2010
  • In this paper, a navigation system was designed, and performance tested in order to confirm the safety improvement of the GNSS(Global Navigation Satellite System)-based AGV(Autonomous Guided Vehicle) which used only position information on of GNSS. We developed DR(Dead Reckoning) navigation system that involve the use of GNSS abnormal positoning error detection and GNSS signal outage. The test results show that GNSS positioning error is detection can be archived with an error of more than 0.15m. In addition, the DR driving position error is 1.5m for an 8s GNSS positioning service outage.