• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.059 seconds

Design and Performance Analysis of a Communication System with AMC and MIMO Mode Selection Scheme (AMC와 MIMO 선택 기법이 결합된 통신 시스템의 설계 및 성능 분석)

  • Lee, Jeong-Hwan;Yoon, Gil-Sang;Cho, In-Sik;Seo, Chang-Woo;Portugal, Sherlie;Hwang, In-Tae
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.3
    • /
    • pp.22-30
    • /
    • 2010
  • This paper proposes a combination system of Adaptive Modulation and Coding (AMC) and Multiple Input Multiple Output (MIMO), which improves the throughput and has a better reliability. In addition, the system includes Precoding, Antenna Subset Selection and MIMO Mode Selection scheme. Finally, we make a performance analysis of the proposed system. The principal environmental parameters for the simulation experiment consist of a frequency non-selective rayleigh fading channel and a Spreading Factor (SF) of 16. Other parameters may be included in order to fulfill the requirements of the HSDP A Standard. The proposed system has a higher throughput and more reliability than the conventional system, which does not include MIMO Mode Selection scheme, Precoding or Antenna Subset Selection. According to the simulation results, the proposed system reaches the maximum throughput at 8dB, presentlng an improvement of 6dB and twice higher throughput, respect to the conventional system. Specifically, at the point of -6dB, the conventional system reaches 2.5Mbps, while the proposed system reaches 6.4Mbps at the same SNR. Also, at the point of 2dB, each system reaches 7.5Mbps (conventional system) and 15.3Mbps (proposed system), with near twice the difference. According to the results exposed above, we can conclude that the system proposed in this paper has, as the greatest contribution, the improvement of the throughput, especially, the average throughput.

A Study on the Field of View of the Remote FTIR Chemical Imaging Detection System (원거리 화학영상탐지시스템의 시야각에 대한 연구)

  • Lee, Jong-Min;Kang, Young-Il;Kim, Ju-Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.122-128
    • /
    • 2014
  • Remote fourier transform infrared(FTIR) chemical imaging detection system allows detection and identification of gases in the atmosphere from long distances. In this paper, the appropriate field of view(FOV) of the FTIR imaging system was examined and the main performance of the system for the interferometer was described. For the determination of the FOV, simulations of gas dispersion range were performed with the NBC reporting and modeling software(NBC-RAMS) developed by ADD. As a result, minimum 192 mrad of FOV was required for the remote FTIR imaging system to visualize chemical warfare agents dispersed in several hundred meters. At the same time, 0.75 mrad of instantaneous field of view(IFOV) for a linear interferometer proper to take a FOV for the chemical agent imaging.

A Comparative Study on the Passenger's Time Saving Effects of Urban Express Railway Service

  • Kim Gyeng-Chul;Chang Byung-Hoon
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.09a
    • /
    • pp.3-16
    • /
    • 1998
  • The goal of the transportation policy of Seoul is to increase the ridership of the subway system by constructing the public transportation network, the subway system. To accomplish this goal, the city of Seoul has been constructing the Metropolitan Subway System. Currently, seven subway lines which connect major areas in Seoul are operating. However, the ridership of subway system was not increased as much as we expected, even though more subway lines have been implemented. It seems that although the length of the subway line was extended, the current way of the subway operation that trains stop at every station cannot satisfy the passenger's need. Thus, we should try to increase the demand by providing quicker services and diversifying the subway operations; changing the point of view is required. This paper introduces the distinctive features of the express subway system and the model for analysing the effects of that system. This paper also presents the results for the feasibility study of the express subway system on the 5th Subway Line and Kyong-Eue Railway Line. Based on the results of the case studies, We can conclude as : First, the express system reduces a total travel time by about $13\%$; in particular, the Kyong-Eue Line is more effective than the subway Line ${\sharp}5$. Second, the shorter headway of express trains increases the time saving effects on subway system although it requests more waiting time to low-speed train passengers. When the service frequency is increased from 5 to 7.5 times/hour, total saved time ratio is about $10\%$ in the Subway Line ${\sharp}5$ and about $18\%$ in the Kyong-Eue Line.

  • PDF

Circular Fresnel POF(Plastic Optical Fiber) Daylighting System Performance Evaluation Study (원형 프레넬 집광형 POF 주광 조명시스템 성능 평가 연구)

  • Kang, Eun-Chul;Choi, Yong-Jun;Yoon, Kwang-Sik;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.31-36
    • /
    • 2011
  • CF(Circular Fresnel) POF(Plastic Optical Fiber) daylighting system is a beam daylighting system utilizing solar direct beam radiation. In this study, a CF POF daylighting system has been introduced, developed and applied to KIER test buildings. The CF POF daylighting system consists of three parts: light collector, light transmitter and light diffuser. The light collector includes a Circular Fresnel lens focusing solar direct illuminance by sun tracking. The light transmitter contains the POF cable which has light transmission loss of 4.5% per meter. The light diffuser has about 80% diffuser efficiency. This study aims to evaluate of POF daylighting system performance. At the results of a CFPOF system performance evaluation, the theoretical CFPOF system efficiency was 41.9% and the actual CFPOF system efficiency at the KIER test building was 37.5%. The difference was due partly to the connecting efficiency.

Evaluation of Natural Ventilation Performance using the Multi-Functional Floor Heating System (다기능온돌시스템을 이용한 자연환기성능 평가)

  • Cho, Dong-Woo;Yu, Ki-Hyung;Yu, Jung-Yeon;Jung, Hae-Kwon
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.105-112
    • /
    • 2007
  • Recently developed raised floor heating system is not only capable of basic function to reduce noise between floors, but also is a multi-functional floor heating system enabling natural ventilation. The procedure of this system for natural ventilation is to import outdoor air through bottom space of the floor heating system, circulate indoor space and discharge it out of ceiling. In winter, powerless natural ventilation is possible with buoyancy effect caused by temperature difference between outdoor and indoor. And it also allows saving of energy by importing pre-heated air in bottom space of the floor heating system. To evaluate ventilation performance of this system, on-site measurement was conducted in 2 test laboratories, and the nominal air change rate was satisfied as 0.4$\sim$0.8 h-1 under the condition of outdoor temperature $5^{\circ}C{\sim}-5^{\circ}C$, which was evaluated as highly possible to be applied as a natural ventilation system in multi-family houses.

  • PDF

Design and Control of an Optimized Battery Charger for an xEV Based on Photovoltaic Power Systems

  • Kim, Dong-Hee;Cheo, Gyu-Yeong;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1602-1613
    • /
    • 2014
  • The continuous growth of electric vehicles has caused electric power shortages in conventional utilities owing to the charging of electric-vehicle batteries. In order to increase the capacity of these utilities, photovoltaic systems may be an appropriate solution because of their benefits. However, a large amount of loss is generated in a conventional charging structure using photovoltaic sources owing to the many power conversion processes. This paper describes a simple integrated battery charger that utilizes a PV generation system. Moreover, the system control algorithm is deduced by analyzing the operation modes in order to control the proposed integrated system. The proposed system and algorithm are verified by a 3.3-kW prototype, resulting in an increase in the efficiency of approximately 7% to 15% compared with the conventional system. And, to examine the feasibility of the proposed system, the simulation for multi-charger with various conditions are progressed.

Synthesis and Studies on Anticonvulsant and Antidepressant Activities of 5-Alkoxy-tetrazolo[1,5-a]quinolines

  • Deng, Xian-Qing;Wei, Cheng-Xi;Song, Ming-Xia;Chai, Kyu-Yun;Sun, Zhi-Gang;Quan, Zhe-Shan
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.2
    • /
    • pp.447-452
    • /
    • 2010
  • A series of 5-alkoxy-tetrazolo[1,5-a]quinolines were synthesized to evaluate their anticonvulsant and antidepressant effects. Anticonvulsant effects and neurotoxicity of the compounds when injected intraperitoneally to mice were determined by a maximal electroshock (MES) test and a rotarod test, respectively. Only three of the synthesized compounds (4a, 4b, 4c) displayed anticonvulsant activity at a dose of 300 mg/kg. Most of the compounds significantly reduced immobility times during the forced swimming test (FST) at a dose of 100 mg/kg, indicative of antidepressant activity. Among the compounds, 5-(2-fluorobenzyloxy)tetrazolo[1,5-a]quinoline (4k) reduced immobility time by 66.85% at 30 mg/kg compared with the same dose of Fluoxetine, which reduced immobility time by 52.30%. According to the results of the 5-Hydroxytryptophan induced head-twitch test and yohimbine toxicity potentiation test, the noradrenergic system seems not to be involved in the antidepressant-like effect of compound 4k while the serotonergic system seems a little to be involved.

Investigation of Target Echoes in Multi-static SONAR System - Part I : Design for Acoustic Measuring System (다중상태 소나시스템을 적용한 표적반향음 연구 - Part I : 측정시스템 설계)

  • Bae, Ho Seuk;Ji, Yoon Hee;Kim, Wan-Jin;Kim, Woo-Shik;Kim, Jea Soo;Yun, Sung-Ung
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.429-439
    • /
    • 2014
  • The target echoes contain information on the target such as the orientation, kinematics, and internal structure, as well as the external geometrical shape of the target. In addition, the pattern of the target echoes depends on the arrangement of the transmitters and receivers in space. Therefore, the study of the target echoes in a multi-static SONAR system can be useful for detecting and tracking submerged objects using an underwater surveillance system. For this purpose, an acoustic measuring system for multi-static target echoes was designed and tested in an acoustic water tank. Some preliminary data are presented and discussed.

Design of Autonomous Cruise Controller with Linear Time Varying Model

  • Chang, Hyuk-Jun;Yoon, Tae Kyun;Lee, Hwi Chan;Yoon, Myung Joon;Moon, Chanwoo;Ahn, Hyun-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2162-2169
    • /
    • 2015
  • Cruise control is a technology for automatically maintaining a steady speed of vehicle as set by the driver via controlling throttle valve and brake of vehicle. In this paper we investigate cruise controller design method with consideration for distance to vehicle ahead. We employ linear time varying (LTV) model to describe longitudinal vehicle dynamic motion. With this LTV system we approximately model the nonlinear dynamics of vehicle speed by frequent update of the system parameters. In addition we reformulate the LTV system by transforming distance to leading vehicle into variation of system parameters of the model. Note that in conventional control problem formulation this distance is considered as disturbance which should be rejected. Consequently a controller can be designed by pole placement at each instance of parameter update, based on the linear model with the present system parameters. The validity of this design method is examined by simulation study.

Development of Lightweight DMFC System for Charging Secondary Battery in Military Operational Environment (군 운용환경에서 이차전지 충전을 위한 경량화 DMFC 시스템 개발)

  • LEE, SUWON;GWAK, GEONHUI;RO, JUNGHO;CHO, YOUNGRAE;KIM, DOYOUN;JU, HYUNCHUL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.5
    • /
    • pp.481-491
    • /
    • 2017
  • In this study, we developed 300 W lightweight DMFC system for charging secondary battery in small unit military operation. In order to reduce the volumetric shape and weight of the system considering the environment of the individual soldier's, the arranging of system components has been optimized. A metal bipolar plates made of STS-470FC have been implemented to the DMFC stack to meet the weight demand of the system. As a result of the performance test of the stack, the target value was satisfied by outputting 561 W exceeding 24% of the stack output 450 W required to output 300 W required for the entire system. Moreover, 2,655 hours exceeding 1,000 hours also has been satisfied. To ensure good robustness of the metallic bipolar plate based DMFC stack, finite element method based simulations are conducted using a commercial ANSYS Fluent software.