• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.067 seconds

Telemetering System of Extremely Low Frequency Magnetic Field Intensity (극저주파 자계 세기를 원격 측정하는 장치)

  • Yoo, Ho-Sang;Wang, Jong-Uk;Seo, Geun-Mee;Gimm, Yoon-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.5 s.120
    • /
    • pp.553-562
    • /
    • 2007
  • In this paper, we designed and implemented the system for telemetering ELF(Extremely Low Frequency) magnetic field intensity. The magnetic field measurement system used a 3-axis magnetic field sensor to measure the magnetic field with isotropy and the equalizer to compensate the frequency characteristic in band. By multiplexing three output signals of the magnetic field sensor in time domain, we got the uniform gain and frequency characteristic among three axes. This system was designed that the magnetic field measurement level range was $0.01{\sim}10.0\;uT$ and the measurement frequency band was $40{\sim}180\;Hz$. The control system would access to the magnetic field measurement system with RF and the maximum access distance was 1.0 km. We confirmed that the measurement level error of the fabricated system was within 5 %. The fabricated system was installed to a golf practice range where a high voltage power transmission line was crossed.

System Performance Variation for Relative Location of Pre-swirl Nozzles and Receiver Holes in Radial On-Board Injection Type Pre-swirl System (반경방향 분사방식 프리스월 시스템의 프리스월 노즐과 리시버 홀의 상대적 위치에 따른 시스템 성능변화)

  • Lee, Jonggeon;Lee, Hyungyu;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.1
    • /
    • pp.43-53
    • /
    • 2020
  • The effect of the relative location between pre-swirl nozzle and receiver hole on the performance of radial on-board injection type pre-swirl system was analyzed. In this study, tendency of the change of discharge coefficient and temperature drop efficiency were analyzed for 20 design points through the combination of 5 pre-swirl nozzle location and 4 receiver hole location. Discharge coefficient of system tended to be similar to the pressure ratio of the pre-swirl nozzle. System performance variation occurred as the flow structure in the cavity was affected by the surface, and the influence of the stationary surface is greater than that of the rotating surface. Discharge coefficient of system changed -1.39% to 1.25% and temperature drop efficiency changed -5.41% to 2.94% refer to reference design point.

Tactics and Pitfalls of MED(Micro Endoscopic Discectomy) System for Lumbar Disc - For Surgeons Who Wish to Attempt - (요추간반 탈출증에 있어 MED(Microendoscopic Discectomy) System을 이용한 수술의 효율성과 수기)

  • Hong, Hyun Jong;Oh, Seong Hoon;Bak, Kwang Hum;Kim, Jae Min;Kim, Choong Hyun;Kim, Young Soo;Ko, Yong;Oh, Suck Jun;Kim, Kwang Myung;Lee, Sang Gu;Kim, Nam Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.1
    • /
    • pp.35-43
    • /
    • 2000
  • Objective : Percutaneous lumbar approaches such as arthroscopic discectomy, laser discectomy, and nucleotome remain controversial and have technical limitations to free fragment disc, bony pathology and access to L5-S1, The purpose of this study was to determine efficacy of this new endoscopic system and to report techniques and tactics. Methods : From July 1997 to May 1998, we treated 40 consecutive patients(43 levels) with the MED system. Mean age was 32 years(range ; 18 to 62). There were 30 males and 10 females. All patients had sciatica with SLRT limitation. There were 23 patients with disc herniation at L4-5 and 14 patients at L5-S1. Three patients had 2 level disc herniations. There was one far lateral disc herniation at L4-5. Results : Using modified MacNab criteria, there were 37 excellent results and 3 good result. Most patients were discharged within 3-4 days except 2 patients with dural tearing. There were no other complications. Mean operation time was 1.5 hours(range : 40 minutes to 2.5 hours). Conclusion : The MED system is a reliable approach to lumbar disc herniations. This system combines the advantages of conventional open surgery and a minimally invasive technique. As tactics for the doctors who wish to attempt, "palpate" the lamina by first dilator, identification of interlaminar space by removal of overlying soft tissue and confirmation of the shoulder portion of nerve root before discectomy are important to this procedure. We conclude that lumbar disc herniations can be successfully treated with MED approach.

  • PDF

An Extended-Weighted Buddy System for an Object-Oriented Computer (객체지향 컴퓨터를 위한 확장-가중치 버디 시스템)

  • Kim, Kwan-Joong;Kim, Byung-Gi
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.6
    • /
    • pp.1625-1635
    • /
    • 1997
  • An extension of the weighted buddy system, called the extended-weighted buddy system, for dynamic memory allocation in an object-oriented computer is presented. The extended-weighted buddy system allows block sizes of $2^k,\;3*2^k,\;5*2^k,\;7*2^k$, whereas the original weighted buddy system allowed block sizes of $2^k\;and\;3*2^k$. This extension is achieved at only the cost of additional 3 bits per block for memory management unit. Simulation results are presented which compare our method with the weighted buddy system. These results indicate that, for uniform request distributions, our system has less internal memory fragmentation than the weighted buddy system(approximately 60%). And, for exponential request distributions, it has less internal memory fragmentation than the weighted buddy method (approximately 50%). The external fragmentation is greater for this system than the weighted buddy system. But, our system has less total memory fragmentation for exponential request distributions, and two systems take a similar total memory fragmentation for uniform request distributions, so we can substitutes the extended-weighted buddy system for weighted buddy system.

  • PDF

The Noise Evaluation for Ragius 150 CR System (Regius 150 Computed Radiography 시스템의 Noise 평가에 관한 연구)

  • Kim, Jung-Min;Min, Jung-Whan;Jeong, Hea-Won;Im, Eun-Kyung;Yang, Han-Joon
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.237-240
    • /
    • 2006
  • The Noise of CR Systems is made up of X-ray quantum mottle and additional Imaging plate's structure noise, photon noise of lumine cence, noise of electrometer, quantization noise etc. In this Regius 150 system, SNR was increased from 8.2 to 30 with linearily according to radiation dose from 0.1 mR to 100 mR. It means that the Regius 150 system has enough trustability because of SNR is over 5 by Rose Model. NPS was calculated two dementional Fourier Transform with shake of pixel value in the white Image. In the spatial frequence range of $0.5\;lp/mm{\sim}2.5\;lp/mm$, the NPS was distributed $10^{-4}{\sim}10^{-5}$ at 1 mR X-ray dose. That is similar result compare other systems to that of Kodak CR system reported by Carlu, HR-CR system reported by Dobbins.

  • PDF

Mark XIIA(Mode 5) IFF System Integration and Certification Test for Surface to Air Missile System (유도무기체계 모드 5 피아식별 체계통합 및 인증시험)

  • Kim, Woo-Hyun;Jung, Se-Young;Lee, Yun-Soo;Chang, Se-Myong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.160-168
    • /
    • 2022
  • The new IFF mode, Mode-5 replacing Mode-4, has already been established by the US DoD for its allies and NATO forces. A IFF retrofit program for replacing the Mark XII Mode-4 with Mark XIIA Mode-5 is in progress in order to overcome the security limitations of the former in R.O.K. IFF certification test for the new mode, Mode-5, has been performed on medium range surface to air missile platform of the Korean armed forces for the first time in R.O.K and this is regarded as a monumental event in Korean defense industry. The present paper is a discussion on the procedures applied to the IFF system retrofit and integration, lessons learned from AIMS test with the US AIMS PO as observer. The minimum modification from the existing Mark XII Mode-4 to Mark XIIA Mode-5 and evolutional adaption from previous design including interoperability are required for the system retrofit. Letter of Certification was received from the US AIMS PO after the tests. The authors propose that the lessons learned and know-how acquired during the tests are managed by the R.O.K Government as the standard structure of a database. It is expected that the use of the database will reduce the developmental difficulties and risk, also increase efficiency in future developments and other projects.

A CFD Modeling of Heat Generation and Charge-Discharge Behavior of a Li-ion Secondary Battery (Li-ion 이차전지의 충방전 시 발열 및 충방전 특성의 CFD 모델링)

  • Kang, Hyeji;Park, Hongbeom;Han, Kyoungho;Yoon, Do Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.3
    • /
    • pp.114-121
    • /
    • 2016
  • This study investigates a CFD modeling of the charge-discharge behavior due to heat generation during charge-discharge cycles of a Li-ion secondary battery(LIB). Present LIB system adopted a current-density equation, heat and mass transfer governing equations upon the 1-dimensional system to the thickness direction for the rectangular pouch configuration. According to the 3-kinds of the charge-discharge current densities of 1C($17.5A/m^2$), 3C($52.5A/m^2$) and 5C($87.5A/m^2$) subject to a 3 V of cut-off voltage, a constant-temperature system at 298 K and three different heat generating systems were analyzed with comparison. Battery capacity decreases with increment of charge-discharge densities not only at the constant-temperature system but also at the heat-generating system. The time for charge-discharge cycles increases at the heat-generating system compare to the constant-temperature system. These trends are considered that the increase of temperature due to heat generation causes the decrement of equilibrium potential of electrodes and the increment of diffusivity of Li ions. Furthermore, cooling effects were discussed in order to control the influence of heat generation due to charge-discharge behavior of a Li-ion secondary battery.

Positioning Accuracy on Robot Self-localization by Real-time Indoor Positioning System with SS Ultrasonic Waves

  • Suzuki, Akimasa;Kumakura, Ken;Tomizuka, Daisuke;Hagiwara, Yoshinobu;Kim, Youngbok;Choi, Yongwoon
    • Journal of Power System Engineering
    • /
    • v.17 no.5
    • /
    • pp.100-111
    • /
    • 2013
  • Indoor real-time positioning for multiple targets is required to realize human-robot symbiosis. This study firstly presents positioning accuracy on an autonomous mobile robot controlled by 3-D coordinates that is obtained by a real-time indoor positioning system with spread spectrum (SS) ultrasonic signals communicated by code-division multiple access. Although many positioning systems have been investigated, the positioning system with the SS ultrasonic signals can measure identified multiple 3-D positions in every 70 ms with noise tolerance and error within 100 mm. This system is also robust to occlusion and environmental changes. However, thus far, the positioning errors in an autonomous mobile robot, controlled by these systems using the SS ultrasonic signals, have not been evaluated as an experimental study. Therefore, a positioning experiment for trajectory control is conducted using an autonomous mobile robot and our positioning system. The effectiveness of this positioning method for robot self-localization is shown, from this experiment, because the average control error between the target position and the robot's position at 29 mm is obtained.

Optimal Operation Condition of Pressurized Methanol Fuel Processor for Underwater Environment (수중환경용 가압형 메탄올 연료프로세서의 최적운전 연구)

  • JI, HYUNJIN;CHOI, EUNYEONG;LEE, JUNGHUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.5
    • /
    • pp.485-493
    • /
    • 2016
  • Recently submarine and unmanned underwater vehicle (UUV) are equipped with a fuel cell system as an air independent propulsion system. Methanol fuel processor can efficiently supply the hydrogen to the fuel cell system to improve the ability to dive. This study investigated the optimal conditions of the methanol fuel processor that may be used in the closed environment. For this purpose, the numerical model based on Gibbs minimization equation was established for steam reformer and three exhaust gas burners. After simulating the characteristics of steam reformer according to the steam-to-carbon ratio (SCR) and the pressure change, the SCR condition was able to narrow down to 1.1 to 1.5. Considering water consumption and the amount of heat recovered from three burners, the optimum condition of the SCR can be determined to be 1.5. Nevertheless, the additional heat supply is required to satisfy the heat balance of the methanol fuel processor in the SCR=1.5. In other to obtain additional amount of heat, the combustion of methanol is better than the increased of SCR in terms of system design.

A High Swing Range, High Bandwidth CMOS PGA and ADC for IF QPSK Receiver Using 1.8V Supply

  • Lee, Woo-Yol;Lim, Jong-Chul;Park, Hee-Won;Hong, Kuk-Tae;Lee, Hyeong-Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.4
    • /
    • pp.276-281
    • /
    • 2005
  • This paper presents a low voltage operating IF QPSK receiver block which is consisted of programmable gain amplifier (PGA) and analog to digital converter. This PGA has 6 bit control and 250MHz bandwidth, $0{\sim}20\;dB$ gain range. Using the proposed PGA architecture (low distortion gain control switch block), we can process the continuous fully differential $0.2{\sim}2.5Vpp$ input/output range and 44MHz carrier with 2 MHz bandwidth signal at 1.8V supply voltage. Using the sub-sampling technique (input freq. is $44{\sim}46MHz$, sampling freq. is 25MHz), we can process the IF QPSK signal ($44{\sim}46MHz$) which is the output of the 6 bit PGA. We can get the SNDR 35dB, which is the result of PGA and ADC at full gain mode. We fabricated the PGA and ADC and the digital signal processing block of the IF QPSK with the 0.18um CMOS MIM process 1.8V Supply.