• 제목/요약/키워드: K-S test

검색결과 24,621건 처리시간 0.058초

A FLOW AND PRESSURE DISTRIBUTION OF APR+ REACTOR UNDER THE 4-PUMP RUNNING CONDITIONS WITH A BALANCED FLOW RATE

  • Euh, D.J.;Kim, K.H.;Youn, Y.J.;Bae, J.H.;Chu, I.C.;Kim, J.T.;Kang, H.S.;Choi, H.S.;Lee, S.T.;Kwon, T.S.
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.735-744
    • /
    • 2012
  • In order to quantify the flow distribution characteristics of APR+ reactor, a test was performed on a test facility, ACOP ($\underline{A}$PR+ $\underline{C}$ore Flow & $\underline{P}$ressure Test Facility), having a length scale of 1/5 referring to the prototype plant. The major parameters are core inlet flow and outlet pressure distribution and sectional pressure drops along the major flow path inside reactor vessel. To preserve the flow characteristics of prototype plant, the test facility was designed based on a preservation of major flow path geometry. An Euler number is considered as primary dimensionless parameter, which is conserved with a 1/40.9 of Reynolds number scaling ratio. ACOP simplifies each fuel assembly into a hydraulic simulator having the same axial flow resistance and lateral cross flow characteristics. In order to supply boundary condition to estimate thermal margins of the reactor, the distribution of inlet core flow and core exit pressure were measured in each of 257 fuel assembly simulators. In total, 584 points of static pressure and differential pressures were measured with a limited number of differential pressure transmitters by developing a sequential operation system of valves. In the current study, reactor flow characteristics under the balanced four-cold leg flow conditions at each of the cold legs were quantified, which is a part of the test matrix composing the APR+ flow distribution test program. The final identification of the reactor flow distribution was obtained by ensemble averaging 15 independent test data. The details of the design of the test facility, experiment, and data analysis are included in the current paper.

Chiness hamster lung cell(CHL)에서 십전대보탕 염색체 이상 시험 (Chromosomalanomaly test of Sipjeondaebo-tang extract using the Chiness hamster lung)

  • 마진열;황대선;이남헌;하혜경;유영법;신현규
    • 대한한의학방제학회지
    • /
    • 제16권2호
    • /
    • pp.145-153
    • /
    • 2008
  • Objectives : This study was to assessment the toxicity of Sipjeondaebo-tang(Shiquan dabu-decoction) by Chromosomalanomaly test. Methods : Sipjeondaebo-tang(Shiquan dabu-decoction) water-extract in vivo Chromosomalanomaly test was performed using chiness hamster lung cell line. Results : Sipjeondaebo-tang water extract was negative in Chromosomalanomaly test at the doses of 0, 625, 1250 and $2500{\mu}g/m\ell$ at 6h and 24h.(S9- fraction). Chromosomalanomaly test(S+fraction) was also negative at the doses of 0, 1250, 2500 and $5000{\mu}g/m\ell$. Conclusions : It was concluded that Sipjeondaebo-tang extract did not induce Chromosomalanomaly in the chiness hamster lung cell.

  • PDF

Nonpararmetric estimation for interval censored competing risk data

  • Kim, Yang-Jin;Kwon, Do young
    • Journal of the Korean Data and Information Science Society
    • /
    • 제28권4호
    • /
    • pp.947-955
    • /
    • 2017
  • A competing risk analysis has been applied when subjects experience more than one type of end points. Geskus (2011) showed three types of estimators of CIF are equivalent under left truncated and right censored data. We extend his approach to an interval censored competing risk data by using a modified risk set and evaluate their performance under several sample sizes. These estimators show very similar results. We also suggest a test statistic combining Sun's test for interval censored data and Gray's test for right censored data. The test sizes and powers are compared under several cases. As a real data application, the suggested method is applied a data where the feasibility of the vaccine to HIV was assessed in the injecting drug uses.

웃음치료가 구안와사환자의 안면마비 회복정도, 통증 및 스트레스에 미치는 효과 (Effects of Laughter Therapy on Recovery Status from Facial Paralysis, Pain and Stress in Bell's palsy Patients)

  • 김미환;김명자
    • 임상간호연구
    • /
    • 제20권2호
    • /
    • pp.211-222
    • /
    • 2014
  • Purpose: This study was done to identify the effects of Laughter therapy on recovery status from facial paralysis, pain, and stress in Bell's palsy patients. Methods: This research was a nonequivalent control group non-synchronized pre-posttest quasi-experimental research design. Data were collected from August 8, to October 15, 2013 at D university Oriental Medical Center in B city. Participants were 60 patients with Bell's palsy who were assigned to one of two groups: an experimental group of 30 patients and a control group of 30 patients. t-test, $x^2-test$, Fisher's exact test and Welth-Aspin test were used to test the homogeneity between the two groups and t-test, Welth-Aspin test and ANCOVA were used to test the research hypotheses. SPSS program was used for statistical analysis. Results: There were significant increases in recovery status from facial paralysis and decreases in stress after Laughter therapy in the experimental group. Conclusion: The results indicate that Laughter therapy is effective in facilitating recovery status from facial paralysis and decreasing stress. Therefore, Laughter therapy can be used as an effective nursing intervention for patients with facial paralysis and to relieve stress in these patients.

유도형 리니어모터의 동특성 해석 (Dynamic Characteristics Analysis of Linear Induction Motor)

  • 장석명;장건우;이성호;정상섭;박영태;김봉섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.626-628
    • /
    • 2000
  • This paper treats the dynamic analysis and test results of Linear Induction Motor. The dynamic analysis is performed by the d,q axis equivalent-circuit model. Equivalent-circut parameters are obtained with no-load, lock test and field analysis. As a results, simulation results are compared with that of dynamic test.

  • PDF

냉장고용 압축기의 가속수명시험을 위한 가혹조건 탐색 - 고온 가혹조건에서의 가속계수와 단축 시험기간 - (Investigation into the Worst Stress Condition for an Accelerated Life Test of a Compressor in Refrigerators - Acceleration Factor and the Reducible Test Time under High Temperature -)

  • 정영미;주우진;정석권
    • 동력기계공학회지
    • /
    • 제16권3호
    • /
    • pp.44-50
    • /
    • 2012
  • The reliability qualification test is essential in order to ensure the life time of the product under the normal operation conditions when a new product is developed. The reliability qualification test period has an important impact on the development time of new product. Therefore, some researches to reduce the test time of reliability qualification test have been actively studied. Generally, accelerated life test is well known as one method that can save the test time of the reliability qualification test. This test is conducted under the higher stress condition than normal condition. So we need to investigate what factor affects to the higher stress condition. This paper shows the relationship between the acceleration factor and reliability qualification test period. Especially, we focused on the method to obtain effective acceleration factors under the high temperature condition. Through some experiments for a refrigerator's compressor, we were able to confirm how to increase acceleration factors and how to reduce the reliability qualification test period with minimum samples.

Modeling and Interoperability Test Case Generation of a Real-Time QoS Monitoring Protocol

  • Chin, Byoung-Moon;Kim, Sung-Un;Kang, Sung-Won;Park, Chee-Hang
    • ETRI Journal
    • /
    • 제21권4호
    • /
    • pp.52-64
    • /
    • 1999
  • QoS monitoring is a kind of real-time systems which allows each level of the system to track the ongoing QoS levels achieved by the lower network layers. For these systems, real-time communications between corresponding transport protocol objects is essential for their correct behavior. When two or more entities are employed to perform a certain task as in the case of communication protocols, the capability to do so is called interoperability and considered as the essential aspect of correctness of communication systems. This paper describes a formal approach on modeling and interoperability test case generation of a real-time QoS monitoring protocol. For this, we specify the behavior of flow monitoring of transport layer QoS protocol, i.e., METS protocol, which is proposed to address QoS from an end-to-end's point of view, based on QoS architecture model which includes ATM net work in lower layers. We use a real-time Input/Output finite State Machine to model the behavior of real-time flow monitoring over time. From the modeled real-time I/OFSM, we generate interoperability test cases to check the correctness of METS protocol's flow monitoring behaviors for two end systems. A new approach to efficient interoperability testing is described and the method of interoperability test cases generation is shown with the example of METS protocol's flow monitoring. The current TTCN is not appropriate for testing real-time and multimedia systems. Because test events in TTCN are for message-based system and not for stream-based systems, the real-time in TTCN can only be approximated. This paper also proposes the notation of real-time Abstract Test Suite by means of real-time extension of TTCN. This approach gives the advantages that only a few syntactical changes are necessary, and TTCN and real-time TTCN are compatible. This formal approach on interoperability testing can be applied to the real-time protocols related to IMT-2000, B-ISDN and real-time systems.

  • PDF

평균과 비율 비교 (Hypothesis Testing: Means and Proportions)

  • 박선일;이영원
    • 한국임상수의학회지
    • /
    • 제26권5호
    • /
    • pp.401-407
    • /
    • 2009
  • In the previous article in this series we introduced the basic concepts for statistical analysis. The present review introduces hypothesis testing for continuous and categorical data for readers of the veterinary science literature. For the analysis of continuous data, we explained t-test to compare a single mean with a hypothesized value and the difference between two means from two independent samples or between two means arising from paired samples. When the data are categorical variables, the $x^2$ test for association and homogeneity, Fisher's exact test and Yates' continuity correction for small samples, and test for trend, in which at least one of the variables is ordinal is described, together with the worked examples. McNemar test for correlated proportions is also discussed. The topics covered may provide a basic understanding of different approaches for analyzing clinical data.

한국형 고속전철 추진성능 검증을 위한 추진시스템 통합시험 (Traction System Combined Test of KHST for Propulsion System Performance Verification)

  • 류홍제;김종수;김용주;노애숙;정은성;최종묵
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.886-890
    • /
    • 2003
  • This paper introduces the combined test results of the traction system for KHST(Korean High Speed Train: hereafter refer to KHST). The main purpose of this combined test is to verify the performance of the traction system that is designed to operate up to maximum 350km/h speed. Combined test system consists of a traction transformer, two AC-DC PWM converters, a PWM Inverter, two traction motors and flywheel system. Flywheel system represents equivalent model of the train inertia. Also traction control system and MASCON Interfaces are included. Various kinds of experiments are performed to prove total traction system performance and detail waveforms are described

  • PDF

전동차 구동대차의 구조해석 및 하중시험 비교 고찰 (A Comparision on Structure Analysis and Load Test of Driving Bogie for Electrical Multiple Unit)

  • 김원경;윤성철;권성태;박옥정
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.404-409
    • /
    • 2005
  • This paper describes the result of structure analysis and load test for bogie frame. The purpose of the analysis and test is to evaluate an safety which body structure shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load. Bogie system consists of bogie frame, suspensions, wheel-sets, braking system and transmission system. Among these component, the bogie frame is most significant component subjected to the vehicle and passenger loads. The evaluation method is used the JIS E 4207 specification throughout the FEM analysis and static load test. The analysis and test results have been very safety and stable for design load conditions.

  • PDF