• Title/Summary/Keyword: K-S test

Search Result 24,629, Processing Time 0.051 seconds

ISO 9705 Room-Corner Test & Model simulations (ISO 9705 Room-Corner Test와 모델 평가)

  • ;S.E. Dillom;J,G Quintiere
    • Fire Science and Engineering
    • /
    • v.13 no.2
    • /
    • pp.3-11
    • /
    • 1999
  • New examination of a predictive model for the ISO 9705 room-corner test have been m made for materials studied by L S Fire Laboratories, Italy. The ISO 9705 test subjects wall a and ceiling mounted materials to a comer ignition source of 100 kW for a duration of 10 m minutes; if flashover does not occur this is followed by 300 kW for another 10 minutes. The m materials that did not stay in place during combustion because of melting, dripping, or d distorting were simulated by an adjustment to the material's total available energy. For m mat려als that remain in place the simulation model appears to do well in its prl어ictions. A l large-s떠Ie room test results 뾰 compar벼 with the m여el’s prediction also.

  • PDF

The Analysis of the Ship's Maneuverability According to the Ship's Trim and Draft (선박 TRIM변화에 따른 조종성능의 분석)

  • PARK, Byung-Soo;KANG, Donghoon;KANG, Il-Kwon;KIM, Hyun-Mu
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.6
    • /
    • pp.1865-1871
    • /
    • 2015
  • Ship's trim is the one of the most important factor for safety at the sea. Turning circle test and Z-test were carried out to find the effect of ship's trim and draft changes. The results are as follows. 1. If the ship's draft and trim became large, turning circle would be wide. 2. If the ship's draft and trim became large, ship's drift angle would be small. Small drift angle made wide turning circle. 3. Trim by the head made slow ship's final speed when turning circle test. 4. By Z-test, the deeper draft and trim by the stern made small OSA. Small OSA means strong ship's stability. 5. Totally 2nd OSA is smaller than 1st OSA on Z-test. 6. There were small differences of 2nd OSA in trim by the stern, but there were large OSA in trim by the head. 7. The larger trim by the stern, the smaller OSW. The small OSW means better ship's stability and maneuverability.

A Study of Environment & Bullet-Proof Capability Test Method for KLTV's Transparent Armour (한국형 전술차량 방탄유리 환경 및 방호력 시험 적용 기법 연구)

  • Park, Jinwon;Park, Youngchan;Kim, Seonjin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.69-73
    • /
    • 2018
  • Korean-peacekeeper's transparent armors in Iraq showed delamination, cracking and clouding a decade ago. And there were also similar deterioration recurrences in KLTV during the operational test a few years ago. Also, the differences between operational capability & lab Bullet-proof test condition, and insufficiency of military protection spec resulted in incomplete bullet-proof results. Moreover, although so many ground weapon systems have been developed, there were not secure test & evaluation codes to verify transparent armoured glasses equal to advanced-overseas products. So in this study, first, environmental test codes were established that all tests should be carried out as the application of only one specimen with newly adopted thermal shock test instead of completing each test with different one. Second, protection standards were integrated through the analysis of global developed country's specifications and reinforced as adding to the real mock-up condition if vehicle's glasses are smaller than standard specimen. Hereby, by applying to test-codes which including actual operational & vehicular conditions, the gap between development test and operational environment was minimized.

On a Nonparametric Test for Parallelism against Ordered Alternatives

  • Song, Moon Sup;Kim, Jaehee;Jean, Jong Woo;Park, Changsoon
    • Journal of Korean Society for Quality Management
    • /
    • v.17 no.2
    • /
    • pp.70-80
    • /
    • 1989
  • A nonparametric test for testing the parallelism of regression lines against ordered alternatives is proposed. The proposed test statistic is based on a linear combination of robust slope estimators. It is a modified version of the Adichie's test statistics based on scores. A snail-sample Monte Carlo study shows that the proposed test is compatible with the Adichie's test.

  • PDF

Application study of C.S.G method by the test construction and field test (시험시공 및 현장시험을 통한 C.S.G 공법의 적용성 검토)

  • Kim, Ki-Young;Park, Han-Gyu;Cho, Sung-Eun;Jeon, Je-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.61-68
    • /
    • 2006
  • Cemented Sand and Gravel(CSG) is a material made by simple mixing of rock-based raw materials such as excavated soil and riverbed gravel together with cement and water. The use of CSG methodl for cofferdam and large dam is gradually increasing in Japan because a quarry and aggregate plants can be diminished. Also, the CSG method can reduce dam construction cost, construction duration and destruction of environment. In this paper, field test and test construction of CSG method was conducted on Hwabuk Dam. The mechanical properties of CSG, such as compressive strength, extention strength and field permeability test were investigated. From the results of the experimental study, application study of CSG method was discussed.

  • PDF

Incidence and Characteristics of Frey's Syndrome after Parotidectomy by Minor's Starch-Iodine Test (이하선 절제술 후 요오드-녹말 검사를 이용한 Frey 증후군의 발생 빈도 및 임상 양상)

  • Kang, Tae Wook;Song, Chang Myeon;Kim, Hong Dae;Ko, Seok Hwa;Jang, Youn Il;Ji, Yong Bae;Tae, Kyung
    • Korean Journal of Head & Neck Oncology
    • /
    • v.32 no.1
    • /
    • pp.1-5
    • /
    • 2016
  • Objectives: Frey's syndrome is an infrequent complication after parotidectomy and its incidence varies from 23.5% to 50.8% in the literature. The objective of this study was to evaluate the actual incidence and clinical characteristics of Frey's syndrome. Methods: We analyzed 31 patients who underwent parotidectomy and serial Minor's starch-iodine test. The mean follow-up period was $66{\pm}26.1$ months (range, 24-118 months). The Frey's syndrome was analyzed using a questionnaire for the assessment of the subjective symptom and Minor's starch-iodine test for the objective measurement at 1, 3, 6, and 12 months after the surgery and then every 6 or 12 months. Minor's starch-iodine test was graded from 0 to 3 according to the area of discolorization. Results: Frey's syndrome occurred in 11 patients (35.5%) on the Minor's starch-iodine test. The mean onset of Frey's syndrome on the starch-iodine test was $13.6{\pm}10.4$ months after parotidectomy. Sixteen patients (51.6%) complained about gustatory sweating and flushing. The onset of the subjective symptom was $11.27{\pm}6.96$ months after the surgery. There was a significant correlation between the grade of the starch-iodine test and the severity of subjective symptoms (P <0.001). Various factors including size and location of tumor, incision method, and extent of parotidectomy did not correlate with the Frey's syndrome. Conclusion: The incidence of Frey's syndrome was 35.5% on the Starch-Iodine test, and the onset was about postoperative 13.6 months.

Cyclic fatigue resistance tests of Nickel-Titanium rotary files using simulated canal and weight loading conditions

  • Cho, Ok-In;Versluis, Antheunis;Cheung, Gary S.P.;Ha, Jung-Hong;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.1
    • /
    • pp.31-35
    • /
    • 2013
  • Objectives: This study compared the cyclic fatigue resistance of nickel-titanium (NiTi) files obtained in a conventional test using a simulated canal with a newly developed method that allows the application of constant fatigue load conditions. Materials and Methods: ProFile and K3 files of #25/.06, #30/.06, and #40/.04 were selected. Two types of testing devices were built to test their fatigue performance. The first (conventional) device prescribed curvature inside a simulated canal (C-test), the second new device exerted a constant load (L-test) whilst allowing any resulting curvature. Ten new instruments of each size and brand were tested with each device. The files were rotated until fracture and the number of cycles to failure (NCF) was determined. The NCF were subjected to one-way ANOVA and Duncan's post-hoc test for each method. Spearman's rank correlation coefficient was computed to examine any association between methods. Results: Spearman's rank correlation coefficient (${\rho}$ = -0.905) showed a significant negative correlation between methods. Groups with significant difference after the L-test divided into 4 clusters, whilst the C-test gave just 2 clusters. From the L-test, considering the negative correlation of NCF, K3 gave a significantly lower fatigue resistance than ProFile as in the C-test. K3 #30/.06 showed a lower fatigue resistance than K3 #25/.06, which was not found by the C-test. Variation in fatigue test methodology resulted in different cyclic fatigue resistance rankings for various NiTi files. Conclusions: The new methodology standardized the load during fatigue testing, allowing determination fatigue behavior under constant load conditions.

Design of Effective Reliability Tests for New Products (신제품 개발에 따른 효과적인 신뢰성 시험 설계)

  • Park, B.H.;Jang, J.S.;Kim, G.Y.;Lee, J.H.;Kim, S.J.;Chan, S.I.;Jeong, K.Y.;Kim, D.J.;Lee, C.B.
    • Journal of Applied Reliability
    • /
    • v.9 no.2
    • /
    • pp.107-119
    • /
    • 2009
  • Reliability tests should be designed to verify whether reliability requirements are satisfied or not effectively and efficiently. The portion of reliability requirements that a reliability test scheme composed of different types of tests can cover is defined as test coverage in software engineering. For the cases of hardwares, to be effective, a reliability test scheme should enhance the test coverage. This study is to develop an evaluation method of test coverage for a reliability test scheme proposed for new products. Case studies are also given.

  • PDF

The Reliability and Validity Test of Sasangin Diagnostic Questionnaire for Specialist(SDQ_S) (전문가용 사상체질진단지의 신뢰도와 타당도 검사)

  • Pak, Yun-Seong;kim, Je-Shin;Park, Byung-Joo;Yoo, Jung-Hee;Lee, Jun-Hee;Koh, Byung-Hee;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.28 no.2
    • /
    • pp.110-122
    • /
    • 2016
  • Objectives The purpose of this study was to develop the Sasangin Diagnostic Questionnaire for Specialist(SDQ_S) and to evaluate the reliability and validity of SDQ_S for standardization of sasang constitutional diagnosis by korean medicine Specialist in clinical practice.Methods SDQ_S was developed through discussions of three sasang constitutional medical specialist. We recruited 210 subjects aged from 20 to 70, and conducted the evaluation of SDQ_S and sasang constitutional diagnosis. For the reliability test, internal consistency was examined by calculating the cronbach's α coefficient on 88 items excepted measurements of trunk, and independence and agreement was examined by chi-square test and McNemar test for 84 subjects which retested SDQ_S. For the validity test, discriminant functions was derived from the sample group(105 subjects), and they were applied to the test group(105 subjects). We identified the hit-ratio of SDQ_S in the test group.Results and Conclusions In the reliability test, the cronbach's α coefficient was 0.664 and 87 items(98.9%) have dependent relationships between 1st test and 2nd test. And 39 items(44.3%) have high agreements(0.8≤McNemar), 26 items(29.5%) have common agreements(0.4≤McNemar<0.8). In the validity test, four discriminant variables(Soeum Index, Taeeum Index, Torso Ratio I, Taeyang Index) were selected, and two discriminant functions were derived. Total hit-ratio was 74.2%, and hit-ratio of Taeeumin(76.7%) was higher than that of Soeumin(75.9%) and Soyangin(69.7%). SDQ_S has good reliability and validity for sasang constitutional diagnosis.