• 제목/요약/키워드: K-File

검색결과 1,997건 처리시간 0.029초

Precurved Endosonic K-file에 의한 근관확대율 및 만곡도 변화에 대한 연구 (COMPARATIVE STUDY ON PERCENTAGE OF CANAL ENLARGEMENT AND CANAL ANGULATION CHANGE BY PRECURVED ENDOSONIC K-FILE)

  • 허혜경;오원만;양규호
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.316-327
    • /
    • 1995
  • The purpose of this study was to evaluate canal shaping ability and canal angulation change of K-file, straight endosonic K-file and pre curved endosonic K-file. Twenty staight canals and thirty curved canals were selected and divided into five groups according to canals curvature and canal instrumentation method. VI group was prepared by straight endosonic K-file and H1 group by K-file in straigt canals. V2 group was instrumented by straight endosonic K-file, V3 group by pre curved endosonic K-file and H2 group by precurved K-file in curved canals. Radiographs of canals were obtained before and after canal shaping. And postoperative radiographs were compared with preoperative radiographs using superimposition method. The results obtained were as follows ; l. In straight canals, K-file group demonstrated lager percentage of canal enlargement than endosonic K-file group on facial view, but reverse results exhibit on mesial view. 2. In curved canals, precurved K-file group showed largest percentage of canal enlargement, followed by precurved endosonic K-fine group and straight endosonic K-file group was smallest. 3. Percantage of canal enlargement at convex side was greater than at concave side in apical portion of each group. Especially in straight endosonic K-file group, percantage of canal enlargement at convex side and concave side showed sharply difference. 4. In angulation change, the straight endosonic K-file group exhibited the greatest its change, followed by precurved endosonic K-file group and precurved K-file group was the least. Above results suggest that K-file is more effective endodontic instrument than endosonic K-file, and that precurved file is effective for canal shaping in curved canal.

  • PDF

수동형 Stainless Steel, Nickel-Titanium 및 엔진 구동형 Nickel-Titanium File의 근관형성 능력에 관한 비교 연구 (A STUDY ON COMPARISON OF STAINLESS STEEL, NICKEL-TITANIUM HAND, NICKEL-TITANIUM ENGINE-DRIVEN FILE INSTRUMENTATION USING COMPUTED TOMOGRAPHY)

  • 이황;임미경;이건일;이용근
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.391-400
    • /
    • 1998
  • The aim of this study was to determine the shaping ability of stainless-steel K file (S-S K file), nickel-titanium K file (Ni-Ti K file) and engine driven nickel-titanium file (Quantec file) in resin simulated root canal. Computed tomography was used to evaluate the change of the root canal morphology. Thirty nine resin simulated root canal were divided into four groups (A:12, B:12, C:12, D:3). Resin simulated canals were scanned by computed tomography before instrumentation (1st C-T scan). Canals were instrumented using step back preparation technique with S-S K file in group A and Ni-Ti K file in group B. Group C was prepared with engine driven Ni-Ti file. Group D was uninstrumented to compare the 1st C-T scan images with 2nd C-T scan images of root canal. Instrumented canals were again scanned using computed tomography (2nd C-T scan), and reformated images of the uninstrumented canals were compared with images of the instrumented canals. In the sections of 2mm and 6mm from the apex, Quantec file caused significantly less canal transportation than S-S K file and Ni-Ti K file (p<0.05). Quantec file produced more centered than S-S K file and Ni-Ti K file in the sections of 2mm and 4mm from the apex (p<0.05). There was no significant difference in the removed volume of canals among the each groups (p>0.05). However the removed canal volume from the apex to 5mm were significantly higher than them from 5mm to 1mm (p<0.05) in each groups. Under the conditions of this study, preparation with Quantec file was more effective and produce more appropriate canal shapes than S-S K file and Ni-Ti K file.

  • PDF

GT Rotary Ni-Ti file과 함께 사용한 구동용 Ni-Ti file의 근관 성형력 비교에 대한 연구 (Shaping ability of Ni-Ti Rotary files in combination with GT Rotary Ni-Ti file)

  • 신동렬;박상진;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.196-206
    • /
    • 2002
  • 본 연구는 근관의 치관부는 GT Rotary file을 이용하여 성형하고, 근단부는 K-Flexofile, ProFile .04, Lightspeed, HERO642 file로 성형하여 근관용 file의 근관성형력을 비교하는 것이다. 실험 표본으로는 resin simulated root canal blocks(Dentsply, Swiss)를 이용하였고 4개의 군으로 분류하여 실험을 실시하였다. 모든 resin block을 GT Rotary file(Dentsply, Swiss)을 이용하여 치관부를 형성한 후 근단부는 K-Flexofile(Dentsply, Swiss), ProFile .04 taper file(Denstply. Swiss), Lightspeed file(Lightspeed Tech., USA), HERO642 file(Micromega, France)로 ISO size #35까지 형성하였다. 성형 후 preparation time과 instrument failure를 측정하였고 최종 사용한 file을 resin block 내에 재위치시켜 working length의 변화량을 0.5mm 단위로 측정하였다. Resin debris에 의한 canal blockage를 조사하였으며, 근관 내의 인상을 채득하여 canal form을 평가하였다. 성형 전과 성형 후의 사진을 촬영하고 computer software를 이용하여 중첩시킨 후 canal aberration, canal transportation을 평가하여 다음과 같은 결과를 얻었다. 1. Preparation time, working length의 변화량, canal blockage, canal aberration, canal transportation에 있어서 Ni-Ti file이 stainless steel file에 비하여 우수하였다(p<0.05). 반면에 근관성형력에 있어서 canal form과 canal transportation을 제외하고는 세 Ni-Ti file 사이에는 유의차가 없었다(p>0.05). 2. Canal form 중 taper에 있어서 Lightspeed는 적절하지 못한 taper를 보여주었다(p<0.05). 3. Canal transportation에 있어서 Lightspeed 군과 HER0642 군이 K-Flexofile 군과 ProFile .04 군에 비해 적게 나타났고(p<0.05), 특히 만곡의 끝 부분에서는 Lightspeed 군이 가장 적게 나타났다(p<0.05). 이상과 같은 연구결과로 보아 부적절한 taper를 지니고 있던 Lightspeed fie과 HERO642 file 중 HERO642 file은 GT Rotary file과 함께 사용함으로써 적절한 taper로 형성할 수 있었으나 Lightspeed file은 효과적이지 못하였으므로 적절한 taper를 형성하기 위한 file이 치근의 중간부를 형성하기 위해 필요함이 확인되었다.

세 종류의 Stainless Steel File을 이용한 만곡근관 형성 후 근관형태 변화에 관한 비교 연구 (A Comparison of Three Stainless Steel Instruments in the Preparation of Curved Root Canals in vitro)

  • Young-Tae Kim;Seung-Ho Baek;Kwang-Sik Bae;Sung-Sam Lim;Soo-Han Yoon
    • Restorative Dentistry and Endodontics
    • /
    • 제26권1호
    • /
    • pp.9-15
    • /
    • 2001
  • 통상적인 근관형성 과정에서 근관형태의 직선화 경향을 발견할 수 있으며, 그 결과 만곡이 심한 근관에서 이상적인 근관형태를 얻기가 어렵다. 이를 극복하기 위한 많은 기구들과 근관 성형법들이 개선되고 소개되었다. 본 연구에서는 최근에 개발된 직사각형의 단면을 가지는 stainless steel file인 RT file과 Flex-R file, K-file을 이용하여 만곡근관 형성 후 최종 근관형태를 비교하여 각 file을 평가하고자 한다. 본 실험은 Bramante등의 방법을 변형하여 술 전의 근관형태와 술 후의 근관형태를 비교하였다. Schneider의 방법을 변형하여 3차원적 만곡을 계산하여 12도에서 36도 이내에 만곡도를 가진 근관을 선택하였다. 49개의 발거된 상악대구치 협측근관이나 하악대구치 근심근관을 3개의 군으로 나누고 레진과 플라스틱으로 제작된 mold에 투명한 교정용 레진으로 매몰하였다. 근첨에서 2.5, 5, 8mm지점에서 절단하여 각 mold에서 재조립한 후 다음과 같이 근관형성을 시행하였다. 제 1군은 SS K-file을 이용하여 step-back 방법 ; 제 2군은 Flex-R file을 이용하여 balanced force 방법 ; 제 3군은 RT file을 이용하여 step-back 방법으로 근관 형성하였다. 술 전과 술 후에 각 시편들을 체현미경으로 사진촬영하여 근관 중심 위치 이동률, 근관형성으로 삭제된 상아질양, 근관형성 후 모양을 Sigma scan/ image software program으로 계산하고 One way ANOVA로 통계적 유의성을 검증하여 다음과 같은 결론을 얻었다. 1. RT file이 치근단에서 K-file보다 유의성 있게 근관의 중심을 유지하는 것으로 보였다. 치아 중앙부에서는 RT file과 Flex-R file이 K-file에 대해 유의성 있게 우수한 것으로 나타났다. 2. 근관형성 후 삭제된 상아질양에서는 치근단에서 RT file이 적게 나왔으나 유의성은 없었다. 3. 근관형성 후 절단면 모양은 원형, 타원형, 불규칙한 형태들이 다양하게 나타났고 각 군간에 유의성 있는 차이는 없었다.

  • PDF

Nickel-Titanium file과 Stainless steel file을 이용한 근관형성시 컴퓨터 단층촬영사진상의 근관형태 변화에 관한 연구 (A STUDY ON THE ROOT CANAL MORPHOLOGY CHANGE BY NICKEL-TITANIUM AND STAINLESS STEEL FILE INSTRUMENTATION USING COMPUTERIZED TOMOGRAPHY)

  • 소문섭;임미경;이건일;이용근;이수종
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.659-669
    • /
    • 1997
  • The goals of root canal instrumentation are complete debridement of pulp tissue, removal of microbes and affected dentin, and proper cleaning and shaping of the root canal space before obturation. Instrumentation with stainless steel files has been shown to produce undesirable results in canals, regardless of the improved technique or modified file type used. Nickel-Titanium(Ni-Ti) alloy has been shown to be exceptionally elastic, having a lower bending moment and lower permanent set after torsion, compared with similar gauge stainless steel. The purpose of this study was to evaluate the change of root canal prepared by Ni-Ti rotary and stainless steel instruments. Thirty-four single rooted teeth of similar shape and canal size were divided into three groups. The teeth were scanned by computed tomography before instrumentation. In group 1, canals were instrumented using a step-back technique with K-file. In group 2, canals were prepared with K-flex file using the same technique as group 1. Group 3 was prepared with nickel-titanium(Ni-Ti) rotary instrument using a manufacture's instruction. Instrumented teeth were again scanned using computed tomography, and reformated images of the uninstrumented canals were compared with images of the instrumented canals. K-flex file and Ni-Ti file caused significantly less canal transportation than K-file in the 8mm root canal section from the apex(p<0.05). K-flex file and Ni-Ti file produced more centered canal preparation than K-file in the 2mm section(p<0.05). Ni-Ti file maintained more precisely the center of the canal than K-flex file in the 10mm section (p<0.05). There was no difference in the removed volume of canals among each groups.

  • PDF

수종 근관확대 기구의 만곡된 치근관 성형능력 (SHAPING ABILITY OF ROOT CANAL INSTRUMENTS ON CURVED ROOT CANALS)

  • 김명수;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제17권1호
    • /
    • pp.141-152
    • /
    • 1992
  • Four endodontic instruments from different manufacturers(K - file, Hedstrom - file, K - flex - file, Cavi - Endo) were used to shape 80 mesial canals of extracted posterior teeth. The instrument's ability to enlarge and shape the canals as the original canal shape was assessed by superimposing radiographs of canals obtained before and after canal shaping. The results were as follows 1. Hedstrom - file enlarged canals greater than K - file, K - flex - file, and Cavi - Endo(P<0.05). There are no differences in canal enlargement among K - flex, K - flex - file, and Cavi - Endo(P<0.05). 2. All the instruments showed no difference in canal enlargement between convex side and concave side of B point in proximal and clinical radiographic views, but at the concave side of C point canals were enlarged greater than at the convex side(proximal view of K - file: P<0.05, the others: P<0.01). 3. There was no difference m canal enlargement between convex side and concave side in proximal view of A and D points of K - file and K - flex - file(P<0.05). But in clinical view, canal enlargement at convex side of A point and concave side of D point was greater than that at concave side of A point and convex side of D point respectively. 4. Hedstrom - files showed greater canal enlargement at convex side of A points and concave side of D points (P<0.05 or P<0.01). Cavi - Endo showed no difference in canal enlargement between convex side and concave side at A and D points in proximal view(P<0.05). Bur canal enlargement was greater at concave side than at convex side of D point in clinical view. 5. K - file and Cavi - Endo showed no differences in canal enlargement between convex and concave side in proximal and clinical view (P<0.05). K - flex - file showed greater canal enlargement at concave side in proximal and clinical view(P<0.0:5). Hedstrom file showed no difference in canal enlargement between convex side and concave side in proximal view, but showed greater canal enlargement at concave side in clinical view(P<0.05).

  • PDF

File Modification Pattern Detection Mechanism Using File Similarity Information

  • Jung, Ho-Min;Ko, Yong-Woong
    • International journal of advanced smart convergence
    • /
    • 제1권1호
    • /
    • pp.34-37
    • /
    • 2012
  • In a storage system, the performance of data deduplication can be increased if we consider the file modification pattern. For example, if a file is modified at the end of file region then fixed-length chunking algorithm superior to variable-length chunking. Therefore, it is important to predict in which location of a file is modified between files. In this paper, the essential idea is to exploit an efficient file pattern checking scheme that can be used for data deduplication system. The file modification pattern can be used for elaborating data deduplication system for selecting deduplication algorithm. Experiment result shows that the proposed system can predict file modification region with high probability.

안드로이드 운영체제의 Ext4 파일 시스템에서 삭제 파일 카빙 기법 (File Carving for Ext4 File System on Android OS)

  • 김도현;박정흠;이상진
    • 정보보호학회논문지
    • /
    • 제23권3호
    • /
    • pp.417-429
    • /
    • 2013
  • 많은 리눅스 운영체제와 안드로이드 운영체제에서 Ext4 파일 시스템을 사용하고 있어 디지털 포렌식 관점에서 Ext4 파일 시스템 상의 삭제 파일 복구가 현안이 되고 있다. 본 논문은 Ext4 파일 시스템에서 파일의 할당, 삭제 시 특징을 분석함으로써 삭제된 파일에 대한 복구 방법을 제시하였다. 특히 안드로이드 운영체제의 파일 할당 정책을 바탕으로 비 할당 영역에 조각나 있는 삭제된 파일에 대한 복구 방법을 제시한다.

하둡 플랫폼을 이용한 대량의 스몰파일 처리방법 (Processing Method of Mass Small File Using Hadoop Platform)

  • 김창복;정재필
    • 한국항행학회논문지
    • /
    • 제18권4호
    • /
    • pp.401-408
    • /
    • 2014
  • 하둡(Hadoop)은 맵리듀스(MapReduce) 분산처리 프로그래밍 모델과 HDFS(Hadoop distributed file system) 분산 파일시스템으로 구성된다. 하둡은 빅데이터 처리에 적합한 프레임워크로서, 대량의 스몰파일 처리에 문제점이 있다. 하둡에서 대량의 스몰파일 처리는 하나의 파일마다 매퍼가 생성되며, 파일의 메타정보를 저장하기 위해 많은 메모리가 필요한 문제점이 있다. 본 논문은 하둡 플랫폼에서 다양한 방법으로 대량의 스몰파일 처리방법을 비교 검토하였다. 일반 압축은 데이터의 크기와 상관없이 하나의 매퍼로 처리해야 하기 때문에, 하둡 처리 포맷으로 적절하지 않다. 시퀀스 와 하둡 아카이브 파일의 처리는 스몰파일을 압축 및 병합을 통해 네임노드의 메모리 문제가 제거되었다. 하둡 아카이브 파일은 스몰파일의 병합시간이 시퀀스 파일보다 빠른 속도를 보였다. CombineFileInputFormat 클래스를 이용한 처리는 병합과정이 필요 없으며, 빅데이터 처리방법과 유사한 속도를 보였다.

Stainless steel hand file과 Ni-Ti rotary file을 이용한 근관 형성시 근단부 근관 형태의 순차적 변화에 대한 평가 (Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using Micro-computed tomography)

  • 이우진;이정호;전경아;서민석;유연지;백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제36권3호
    • /
    • pp.231-237
    • /
    • 2011
  • 연구목적: 본 연구에서는 micro CT를 사용하여 SS K-file, Profile, LightSpeed로 #25부터 #40 크기까지 근관을 형성할 때 근단부 근관 형태의 연속되는 변화를 평가하였다. 연구 재료 및 방법: 30개 하악 대구치의 근심 근관을 ProFile, LightSpeed와 SS K-file로 #25번에서 #40번까지 순차적으로 근관 형성하였고, 매 단계 확대 후 micro CT를 시행하였다. 치근단 1, 2, 3, 5 mm 에서 근관 중심 변위와 삭제되지 않은 단면의 비율을 측정하여 'repeated nested design' 분석방법과 Mann-Whitney test로 유의 수준 p = 0.05에서 검정하였다. 결과: SS K-file군에서 #30 이상 근관 형성 후 유의할 만한 근관 중심 변위가 증가하였고, 근관 형성 과정 어느 단계에서도 삭제되지 않은 면적의 비율이 유의성 있게 감소되지 않았다. ProFile군에서는 치근단 1, 2 mm에서 #40 file로 근관 형성 후 근관 중심 변위가 크게 증가하였고, 치근단 1 mm에서 #35 크기로 근관 형성한 후에 삭제되지 않은 면적의 비율이 유의성 있게 감소하였다. LightSpeed군에서는 급격한 근관 중심 변위를 관찰할 수 없었고, 근관 중심 변위가 ProFile군보다 적게 관찰되었다. 결론: SS K-file, Profile, LightSpeed에서 형성되는 근관의 변이 정도는 근단부 근관 형성 크기에 따라 다르게 나타났다.