• Title/Summary/Keyword: K-EMS

Search Result 535, Processing Time 0.037 seconds

Effects of Inhibitors on Cross-Adaptive Response to Ultraviolet Radiation or Ethyl methanesulfonate in Chinese Hamster Ovary Cells

  • Lee, Dong-Wook;Shin, Eun-Joo;Kim, Seon-Young;Um, Kyung-Il
    • Environmental Mutagens and Carcinogens
    • /
    • v.16 no.2
    • /
    • pp.83-87
    • /
    • 1996
  • This study was performed by the sister chromatid exchanges (SCEs) to investigate the effects of Aphidicolin (APC) or 2, 4-dinitrophenoi (DNP) on cross-adaptive response to ultraviolet radiation (UV) or ethyl methanesulfonate (EMS) in Chinese hamster ovary (CHO) cells. The pretreatment with 1 J/m$^2$ UV decreased the yield of SCEs induced by subsequent treatment with 8 mM EMS in CHO cells. And the treatment with 10 $\mu$g/ml APC or 50 $\mu$M DNP during incubation after pretreatment with 1 J/m$^2$ UV increased the yield of SCEs induced by 8 mM EMS. The pretreatment with 2 mM EMS decreased the yield of SCEs induced by subsequent treatment with 5 J/m$^2$ UV. The treatment with 10 $\mu$g/ml APC during incubation after 2 mM EMS increased the yield of SCEs induced by 5 J/m$^2$ UV. These results suggest that APC and DNP inhibit cross-adaptive response to pretreatment with UV and subsequent treatment with EMS, and also cross-adaptive response to pretreatment with EMS and subsequent treatment with UV is inhibited by APC in CHO cells.

  • PDF

EMS Rules for Balanced Factorial Designs under No Restriction on Interaction

  • Choi Byoung-Chul
    • Communications for Statistical Applications and Methods
    • /
    • v.12 no.1
    • /
    • pp.47-59
    • /
    • 2005
  • Expected mean square(EMS) is an important part of conducting the analysis of variance in the experimental design problem, especially in mixed or random models. We present a set of EMS rules for balanced factorial designs under no restriction on interaction. Also we point out how to use the variance component of SPSS or SAS procedure to obtain EMS.

Design and Implementation of KPX's next control center (전력거래소 차기 계통운영시스템 설계에 관한 연구)

  • Choi, Young-Min;Park, Min-Ryung;Lee, Jin-Su;Lee, Gun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.380-381
    • /
    • 2011
  • 전력거래소는 2014년 나주본사이전 이후 1억kW 대용량 전력계통을 운영하기 위한 차기 계통운영시스템(이하 차기EMS) 구축을 계획하고 있다. EMS(Energy Management System)는 전국의 발, 변전소에서 계통정보를 실시간으로 취득하여 전력계통을 감시하며, 연료비 기반의 최적 경제점을 찾아 발전기를 제어하고, 전력계통을 수식화한 상태추정 결과를 기반으로 상정사고분석, 고장전류계산 등 전력계통운영을 위한 종합시스템이다. 국내 EMS의 역사는 1979년 미국의 L&N 시스템 도입을 시작으로 1988년 일본의 Toshiba EMS, 2001년 Alstom사의 NEMS를 구축하여 현재 운영중에 있다. 하지만, 외산 제품 도입에 따른 기술이전, 유지보수의 어려움을 타개하기 위해 2004년 한국형 EMS(이하 K-EMS) 연구개발계획을 수립하고 전력거래소를 주축으로 한 산학연을 구성하여 2010년 K-EMS 개발을 성공적으로 완료하였다. 차기 EMS는 국내 기술력으로 개발된 정부연구과제 성과물인 K-EMS를 기반으로 구축이 이루어지며, 총 3년간의 개발 및 시험과정을 거쳐 실계통운영을 담당할 예정이다. 차기EMS가 설치되어 운영예정인 급전소는 전력수급 균형유지와 발전소 운영 총괄 지휘 및 765kV, 345kV 송전망 운영역할을 담당할 나주급전소와 154kV 비수도권 송전망 운영을 담당할 천안급전소, 154kV 수도권 송전망 운영을 책임질 서울급전소 이상 3곳이다. 차기EMS는 발전 및 송, 변전 설비의 대형화, 다양한 FACTS 설비, 신재생에너지원으로 대표되는 분산전원의 등장과 같은 급변하는 전력계통 변화에 능동적인 역할을 성공적으로 수행할 것으로 기대하고 있다.

  • PDF

A Comparison of the Grain Size of Semisolid A356 Aluminum Alloy Obtained by EMS Stirring and Grain Refinement (전자 교반과 결정립 미세화에 의한 반용융 A356 재료의 결정립 크기 비교)

  • Yang Z.;Seo P. K.;Ko J. H.;Jung Y. S.;Kang C. G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.148-151
    • /
    • 2004
  • Different kinds of feedstock of semisolid a356 aluminum alloy manufactured by EMS stirring only, inoculation of Al-5Ti-B only and combination of inoculation and EMS stirring were investigated. It is found that the grain size of these feedstock are $350{\mu}m$ for EMS casting only, $320{\mu}m$ for inoculation by Al-5Ti-B, and $100{\mu}m$ for the combination of EMS stirring and inoculation of Al-5Ti-B master alloys. The microstructure of the sample obtain by combination of inoculation and EMS system show the best homogeneousness and finest grains.

  • PDF

A Survey of Musculoskeletal Symptoms & Risk Factors for the 119 Emergency Medical Services (EMS) Activities (119 구급대원 구급활동의 근골격계 증상 및 위험실태)

  • Kim, Day-Sung;Moon, Myung-Kug;Kim, Kyoo-Sang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.2
    • /
    • pp.211-216
    • /
    • 2010
  • Fire service personnel and ambulance paramedics suffer musculoskeletal disorders as they lift and carry patients while performing Emergency Medical Services (EMS). The objective of the current study was performed to examine the association between working environment and musculoskeletal disorders of 119 paramedics and to analysis the EMS activities for them through basic survey (including task characteristics, risk factors, symptoms and illnesses). Observational job analysis of EMS activities indicated the squatting posture during first-aid performed on floor and the abrupt use of force during carrying heavy load including stretcher with patients on as hazard factors, and excessive low back twisting and bending during stairway transfer was observed. In addition, work-physiological assessment revealed various but rather high lumbar muscle usage rate among the study subjects, being 14.6~32.8% compared with Maximum Voluntary Contraction (MVC) during patients transfer work. Resting heart rate showed 65/min, on the other hand, heart rate on mobilization indicated maximum 124~156/min. Therefore, the results of analysis to the EMS activities, rescuer activities and medical tasks were accompanied with high possibility of accident and musculoskeletal disorders. Also, EMS activities indicated high muscle fatigue and energy consumption, and accumulated muscle fatigue with during continued work.

Development of Real Time SCADA Database in Korean EMS (한국형 EMS의 실시간 SCADA 데이터베이스 설계에 관한 연구)

  • Lee, Hyo-Sang;Kim, Wan-Hong;Park, Min-Ryung;Yoon, Yeo-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.404-405
    • /
    • 2007
  • 한국의 전력계통 운영환경에 적합한 한국형 에너지 관리 시스템(이하 K-EMS)의 개발에 있어 실시간 SCADA 데이터베이스의 설계는 EMS의 성공을 가늠하는 핵심 요소이다. 특히, 계통규모가 커지고 다양한 계통 어플리케이션들이 개발, 활용됨에 따라 방대한 양의 현장 데이터를 실시간으로 취득하여 관리하고 어플리케이션에 필요한 데이터 인터페이스를 제공하는 EMS SCADA 데이터베이스의 중요성이 증대되고 있다. 이에 K-EMS 개발의 일환으로 개발 중인 K-EMS SCADA 시스템의 개요 및 데이터베이스 설계에 대해 소개하고자 한다

  • PDF

Production of Biosurfactant by Pseudomonas aeruginosa EMS1 from Soybean Oil and Whey

  • Cha, Mi-Sun;Kim, Min-Joo;Lee, Kyung-Min;Son, Hong-Joo;Park, Eun-Hee;Lee, Sang-Joon
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_1
    • /
    • pp.41-45
    • /
    • 2001
  • Pseudomonas aeruginosa EMS1, isolated from activated sludge, was able to grow an produce a biosurfactant on 4.5 % soybean oil, used as the source of energy and carbon. Pseudomonas aeruginosa EMS1 was cultivated at 3$0^{\circ}C$ in a reciprocal shaking incubator, and the highest biosurfactant production was observed after 3 days. Furthermore, Pseudomonas aeruginosa EMS1 was also able to use whey as a co-substrate for biosurfactant production and growth

  • PDF

Effects of Colchicine and EMS on Induction of Variants in Wasabia japonica MATSUM (Colchicine과 EMS 처리에 의한 고추냉이의 변이체 유도)

  • Park, Kie-In;Yoon, Myung-Ja;Kwon, Sung-Whan;Choi, Sun-Yong;Lee, Kang-Soo
    • Korean Journal of Medicinal Crop Science
    • /
    • v.4 no.1
    • /
    • pp.12-18
    • /
    • 1996
  • This study was investigated to improve the rate of the seed germination of Wasabia japonica with $GA_3$ and BAP. The germination rate was 36% with 100ppm $GA_3$ only and 32% with 10ppm BAP only, while that was 65% with combination of 100ppm $GA_3$ and 10ppm BAP compared to that of 7.5% in control. This results show us that the most effect of germination rate was with 100ppm $GA_3$ and 10ppm BAP. Mutagenesis was induced with mutagen, EMS and colchicine. Before the germination, the survival rate was 62% with 0.5% colchicine compared to that of 7% in control. After the germination, the 85% of developed seed was alive with treatment of 0.5% colchicine and 55% of those was alive with 0.06% EMS compared to that of 8% in control. We analyzed the karyotype and isozyme pattern of Wasabia japonica induced with colchicine and EMS. The tetratype of Wasabia japonica was observed from Wasabia japonica treated with 0.5% colchicine. whereas it was not observed with 0.06% EMS. The peroxidase pattern of colchicine treated Wasabia japonica was different from nontreatment. but that of EMS treated Wasabia japonica was the same with normal one.

  • PDF