• 제목/요약/키워드: K strain

검색결과 12,675건 처리시간 0.039초

Helicobacter pylori Strain 51 (Korean Isolate): Ordered Overlapping BAC Library, Combined Physical and Genetic Map, and Comparative Analysis with H. pylori Strain 26695 and Strain J99

  • KANG HYUNG-LYUN;LEE WOO-KON;SONG JAE-YOUNG;CHOI SANG-HAENG;PARK SEONG-GYU;RYU BOK-DEOK;LEE EUN-JOO;KIM JI-SUN;PARK JEONG-UCK;BAIK SEUNG-CHUL;CHOI MYOUNG-BUM;YOUN HEE-SHANG;KO GYUNG-HYUCK
    • Journal of Microbiology and Biotechnology
    • /
    • 제15권4호
    • /
    • pp.844-854
    • /
    • 2005
  • We constructed a defined physical and genetic map of H. pylori strain 51, previously isolated from a Korean patient with a duodenal ulcer, by combining a restriction analysis by pulse-field gel electrophoresis with the construction of a BAC library. A Notl-digest of H. pylori strain 51 genome yielded seven fragments, from which the genomic size was estimated to be 1,698$\pm$24 kb. The BAC library was constructed from 50 to 200 kb fragments of HindIII-digested genomic DNA. From 700 BAC clones, an ordered overlapping maxi-set of 82 BAC clones was assembled that covered the entire genome. The positions of 15 genes were localized in the strain 51 genome with 4-22 kb of resolution and were compared with their orthologues in strain 26695 and strain J99. The arrangement of the 15 genes was identical in strain 51 and strain J99, except for flaA and hpaA. The plasticity zone of strain 51, like that of strain J99, was located in the single region, and was shorter than those of strain 26695 and strain J99. The strain 51 plasticity zone consisted of ORFs common only to strain 51 and J99 or to strain 51 and 26695, as well as strain 51-specific ORFs. Three genetic translocations and/or inversions were found between orthologue ORFs in strain 51 and strain J99. These results show that the chromosomal organization of strain 51 differs from Western strains such as strain 26695 and strain J99.

Tensile Strain Characteristics of Critical Current in YBCO Coated Conductors (YBCO CC테이프 임계전류의 인장변형률 특성)

  • Shin, Hyung-Seop;Kim, Ki-Hyun;Oh, Sang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.274-275
    • /
    • 2005
  • The tensile strain dependency of critical current in YBCO coated conductors was examined at 77K and in the self magnetic field. A commercially available YBCO sample with Cu stabilizer layer was supplied. There existed a peak in the relation between the Ie and tensile strain, and the reversible variation of $I_c$ with applied tensile strain was found. In the neutral axis Ni alloy RABiTS-$Y_2O_3$/YSZ/$CeO_2$ buffered YBCO tape, the $I_c$ recovered reversibly until the applied strain reached to about 0.5%, representing that a significant residual compressive strain induced during cooling to 77 K influenced the axial strain tolerance of YBCO conductors. To investigate the strain and stress influence on the $I_c$, the stress-strain characteristics of YBCO conductors measured at 77 K were discussed.

  • PDF

Fatigue characteristics of distributed sensing cables under low cycle elongation

  • Zhang, Dan;Wang, Jiacheng;li, Bo;Shi, Bin
    • Smart Structures and Systems
    • /
    • 제18권6호
    • /
    • pp.1203-1215
    • /
    • 2016
  • When strain sensing cables are under long-term stress and cyclic loading, creep may occur in the jacket material and each layer of the cable structure may slide relative to other layers, causing fatigue in the cables. This study proposes a device for testing the fatigue characteristics of three types of cables operating under different conditions to establish a decay model for observing the patterns of strain decay. The fatigue characteristics of cables encased in polyurethane (PU), GFRP-reinforced, and wire rope-reinforced jackets were compared. The findings are outlined as follows. The cable strain decayed exponentially, and the decay process involved quick decay, slow decay, and stabilization stages. Moreover, the strain decay increased with the initial strain and tensile frequency. The shorter the unstrained period was, the more similar the initial strain levels of the strain decay curves were to the stabilized strain levels of the first cyclic elongation. As the unstrained period increased, the initial strain levels of the strain decay curves approached those of the first cyclic elongation. The tested sensing cables differed in the amount and rate of strain decay. The wire rope-reinforced cable exhibited the smallest amount and rate of decay, whereas the GFRP-reinforced cable demonstrated the largest.

Influence of Strain Rate on Tensile Properties and Dynamic Strain Aging of an Fe-24.5Mn-4Cr-0.45C Alloy (변형률 속도에 따른 Fe-24.5Mn-4Cr-0.45C 합금의 인장 특성과 동적 변형시효)

  • Lee, Seung-Yong;Hwang, Byoungchul
    • Korean Journal of Materials Research
    • /
    • 제26권5호
    • /
    • pp.281-286
    • /
    • 2016
  • In the present study, the tensile properties and dynamic strain aging of an Fe-24.5Mn-4Cr-0.45C alloy were investigated in terms of strain rate. During tensile testing at room temperature, all the stress-strain curves exhibited serrated plastic flows related to dynamic strain aging, regardless of the strain rate. Serration appeared right after yield stress at lower strain rates, while it was hardly observed at high strain rates. On the other hand, strain-rate sensitivity, indicating a general relationship between flow stress and strain rate at constant strain and temperature, changed from positive to negative as the strain increased. The negative strain-rate sensitivity can be explained by the Portevin Le Chatelier effect, which is associated with dynamic strain aging and is dependent on the strain rate because it is very likely that the dynamic strain aging phenomenon in high-manganese steels is involved in the interaction between moving dislocations and point-defect complexes.

Combined strain gradient and concrete strength effects on flexural strength and ductility design of RC columns

  • Chen, M.T.;Ho, J.C.M.
    • Computers and Concrete
    • /
    • 제15권4호
    • /
    • pp.607-642
    • /
    • 2015
  • The stress-strain relationship of concrete in flexure is one of the essential parameters in assessing the flexural strength and ductility of reinforced concrete (RC) columns. An overview of previous research studies revealed that the presence of strain gradient would affect the maximum concrete stress developed in flexure. However, no quantitative model was available to evaluate the strain gradient effect on concrete under flexure. Previously, the authors have conducted experimental studies to investigate the strain gradient effect on maximum concrete stress and respective strain and developed two strain-gradient-dependent factors k3 and ko for modifying the flexural concrete stress-strain curve. As a continued study, the authors herein will extend the investigation of strain gradient effects on flexural strength and ductility of RC columns to concrete strength up to 100 MPa by employing the strain-gradient-dependent concrete stress-strain curve using nonlinear moment-curvature analysis. It was evident from the results that both the flexural strength and ductility of RC columns are improved under strain gradient effect. Lastly, for practical engineering design purpose, a new equivalent rectangular concrete stress block incorporating the combined effects of strain gradient and concrete strength was proposed and validated. Design formulas and charts have also been presented for flexural strength and ductility of RC columns.

Interpretation of coefficient of consolidation from CRS test results

  • Jia, Rui;Chai, Jinchun;Hino, Takenori
    • Geomechanics and Engineering
    • /
    • 제5권1호
    • /
    • pp.57-70
    • /
    • 2013
  • Constant rate of strain (CRS) consolidation tests were conducted for undisturbed Ariake clay samples from three boreholes in Saga Plain of Kyushu Island, Japan. The coefficients of consolidation ($c_{\nu}$) were interpreted from the CRS test results by small- and large-strain theory. Large-strain theory was found to interpret smaller $c_{\nu}$ values and less strain rate effect on $c_{\nu}$ than that by small-strain theory. Comparing the theoretical strain distributions within a soil specimen to those obtained by numerical simulation shows that the small-strain theory can be used only for the dimensionless parameter $c_{\nu}/\dot{\varepsilon}H_0^2{\geq}50$ (where $\dot{\varepsilon}$ is strain rate and $H_0$ is the specimen height), and the large-strain theory can be used for a larger range of strain rates. Applying the criterion to undisturbed Ariake clay with a $c_{\nu}$ value of about $1{\times}10^{-7}\;m^2/s$, it is suggested that the large-strain theory should be adopted for calculating the $c_{\nu}$ value when $\dot{\varepsilon}$ > 0.03%/min.

Determination of Stress Intensity Factors by Strain Measurement (스트레인측정에 의한 응력확대계수 결정)

  • Lee, O.S.;Nah, K.C.
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제12권8호
    • /
    • pp.147-155
    • /
    • 1995
  • Recent experimental studies have been shown that strain gages can be employed to determine either static or dynamic stress intensity factors $K_{I}$ wiht relatively simple experiments. However, it does not usually provide a reliable value of stress intensity factor because of local yielding and limited regions for strain gage placement at the vicinity of the crack tip. This paper attempted to define a valid region and to indicate procedures for locating and orienting the strain gage to determine static toughness $K_{Is}$ accurately form one strain gage readings with respect to varying loadings. The strain gage methods was used for compact tension specimens made of Polycarbonate and PMMA(polymethyl methacrylate). Series expansions of the static and dynamic strain fields are applied. Strain gage orientation and location are then studied to optimize the strain response. Especially, in the dynamic experiment, the specimen employed is an oversized Charpy V-notch specimen which has been modified to provide significant constraint with a large elevation of the flow stress. The impact behavior of the specimen is monitored by placing strain gage near the crack tip. The dynamic toughness $K_{Id}$ is determined from the strain time traces of this gage.e.

  • PDF

Prediction of Liquation Crack Initiation at HAZ of Laser Weldment Based on Strain Analysis at Elevated Temperature

  • Yamamoto, Motomichi;Shinozaki, Kenji;Kitamura, Mitsuru;Shirai, Makoto
    • Proceedings of the KWS Conference
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.244-249
    • /
    • 2002
  • The purpose of this study is to develope the prediction method of liquation crack initiation in HAZ of laser weldment. Thermal two dimensional strain analyses were performed by FEM for bead-on-plate welding in order to obtain the plastic strain at elevated temperature in HAZ of the laser weldment. From these results, it became clear that the plastic strain at elevated temperature affected liquation crack initiation in HAZ, and it could be proposed that the critical strain, which controlled liquation crack initiation, existed. Moreover, an attempt was made to develop thermal and dynamic three dimensional strain analysis method for the laser weldment in order to obtain the plastic strain at elevated temperature in HAZ of the laser weldment in more detail and precisely.

  • PDF

Strain Hardening Behavior in the Tube Hydroforming (튜브 액압성형품의 가공 경화 특성 연구)

  • Park, H.K.;Yim, H.S.;Yi, H.K.;Kim, K.S.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • 제17권8호
    • /
    • pp.564-569
    • /
    • 2008
  • Strain hardening behavior during hydroforming has been experimentally investigated. The variation of flow stress was used as an index of strain hardening during respective processes and the flow stress was estimated from the correlationship between flow stress and effective strain. The local hardness after hydroformig was also predicted by effective strain. By using the inter-relationships between hardness-flow stress-effective strain at variable pre-strains, the strain hardening behavior during hydroforming has been successfully analyzed. The comparison of predicted hardness with measured hardness confirmed that the methodology used in this study was feasible and the strain hardening behavior can be quantitatively estimated.

Research on Residual Strain of Arterial Cross-Section (동맥 전단부에 분포된 원주 변형율에 대한 잔유 변형율의 영향)

  • Whang, Min-Cheol;Shin, Jung-Woog
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.151-153
    • /
    • 1995
  • Residual strain of artery is studied. There has been experimental evidence that residual strain exists in artery. When ring of artery is longitudinally cut, it is opened. Since strain has been determined without considering residual strain, the existence of residual strain is meaningful in mechanics of arterial wall. Intimal strain concentration is considered to be reduced with both account of residual strain and strain determined by loading. However, it is lack of experimental research. Therefore, this study experimentally attempts to quantify the effect of residual strain on circumferential strain which is determined under the assumption of zero strain with zero pressure.

  • PDF