• 제목/요약/키워드: K ion detection

검색결과 477건 처리시간 0.021초

Polymeric Lead(II)-selective Electrode Based on N,N'-Bis-thiophen-2-ylmethylene-pyridine-2,6-diamine as an Ion Carrier

  • Kim, Hee-Cheol;Lee, Hyo-Kyoung;Choi, A-Young;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권4호
    • /
    • pp.538-542
    • /
    • 2007
  • Polymeric electrodes for lead ion based on N,N'-bis-thiophen-2-ylmethylene-pyridine-2,6-diamine as an ion carrier were prepared. The membrane electrode (m-3) containing o-NPOE as a plasticizer and 50 mol% additive of ionophore gives an excellent Nernstian response (29.59 mV/decade) and the limit of detection of ?log a (M) = 5.74 to Pb2+ in Pb(NO3)2 solution at room temperature. The prepared electrode provided good sensitivity and outstanding selectivity and response for Pb2+ over a wide variety of other metal ions in pH 7.0 buffer solutions. The good sensitivity and selectivity towards lead ion are attributed to the strong complexation of lead ion to N,N'-bis-thiophen-2-ylmethylene-pyridine-2,6-diamine which has geometrically the proper cavity to coordinate to the ligand.

Pilymeric Membrane Sodium Ion-Selective Electrodes Based on Calix[4}arene Triesters

  • 김윤덕;정해상;강성옥;남계천;전승원
    • Bulletin of the Korean Chemical Society
    • /
    • 제22권4호
    • /
    • pp.405-408
    • /
    • 2001
  • New lipophilic triesters of calix[4]arene and calix[4]quinone are investigated as sodium ion-selective ionophores in poly(vinyl chloride) membrane electrodes. For an ion selective electrode based on calix[4]arene triester I, the linear response is 1 ${\times}$10-3.5 to 1 ${\times}$ 10-1 M of Na+ concentrations. The selectivity coefficients for sodium ion over alkali metal and ammonium ions are determined. The detection limit (logaNa+ = -4.50) and the selectivity coefficient (logKNa+,K+pot = -1.86) are obtained for polymeric membrane electrode containing calix[4]arene triester I.

열분무 LC/MS에 의한 인삼사포닌의 분석 (Analysis of Ginsenosides by Thermospray LC/MS)

  • Park, Man-Ki;Park, Jeong-Hill;Hwang, Gwi-Seo;Lee, Mi-Young;Park, In-Jeong
    • Journal of Ginseng Research
    • /
    • 제19권2호
    • /
    • pp.134-137
    • /
    • 1995
  • Ginseng saponins were analyzed by thermospray (TSP) LCMS method using ODS column and with acetonitrile/ammonium acetate solution. Optimal condition for TSP Lchfs was found as follows: capillary temperature: 33$0^{\circ}C$ repelled voltage: 200 V, and concentration of ammonium acetate: 0. 05 M. Panaxadiol and panaxatriol type saponins showed characteristic fragment ions. The calibration curve of ginseng saponin showed good linearity with a correlation coefficient of 0.99. Detection limits using selected ion monitoring (SIM) technique were improved by 10~200 times compared to conventional HPLCnnr detection method.

  • PDF

Mass Spectrometric Analysis of Eight Common Chemical Explosives Using Ion Trap Mass Spectrometer

  • Park, Sehwan;Lee, Jihyeon;Cho, Soo Gyeong;Goh, Eun Mee;Lee, Sungman;Koh, Sung-Suk;Kim, Jeongkwon
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권12호
    • /
    • pp.3659-3664
    • /
    • 2013
  • Eight representative explosives (ammonium perchlorate (AP), ammonium nitrate (AN), trinitrotoluene (TNT), 2,4-dinitrotoluene (DNT), cyclonite (RDX), cyclotetramethylenetetranitramine (HMX), pentaerythritol tetranitrate (PETN), and hexanitrostilbene (HNS)) were comprehensively analyzed with an ion trap mass spectrometer in negative ion mode using direct infusion electrospray ionization. MS/MS experiments were performed to generate fragment ions from the major parent ion of each explosive. Explosives in salt forms such as AP or AN provided cluster parent ions with their own anions. Explosives with an aromatic ring were observed as either $[M-H]^-$ for TNT and DNT or $[M]^{{\cdot}-}$ for HNS, while explosives without an aromatic ring such as RDX, HMX, and PETN were detected as an adduct ion with a formate anion, i.e., $[M+HCOO]^-$. These findings provide a guideline for the rapid and accurate detection of explosives once portable MS instruments become more readily available.

이온쌍-고성능 액체크로마토그래피에 의한 감기약 시럽에서 타르색소 첨가물의 동시분석 (Simultaneous Determination of Tar Color Additives in Cold Syrups by Ion Pair-high Performance Liquid Chromatography)

  • 김경옥;황호;이범규;이원재
    • KSBB Journal
    • /
    • 제25권5호
    • /
    • pp.459-465
    • /
    • 2010
  • A simple and efficient analytical method for the simultaneous determination of seven tar color additives was developed using ion pair high performance liquid chromatography. The conditions for HPLC analysis were as follows: column, ${\mu}$-Bondapak C18 (10 ${\mu}m$, 300 ${\times}$ 3.9 mm i.d.); gradient mobile phase, 0.025 mol/L ammonium acetate (containing 0.01 mol/L tetrabutylammonium bromide)-acetonitrile-methanol (65:25:10) as a mobile for fraction A and 0.025 mol/L ammonium acetate (containing 0.01 mol/L tetrabutylammonium bromide)-acetonitrilemethanol (40:50:10) as a mobile for fraction B; flow rate, 1.0 mL/ min; detection wavelength, 254/520/620 nm. We could attain to the detection limits as 0.01~0.05 ${\mu}$g/mL (254 nm) and 0.005~0.01 ${\mu}$g/mL (520 nm) for six red tar color additives, and 0.05 ${\mu}$g/mL (254 nm) and 0.002 ${\mu}$g/mL (620 nm) for Fast green FCF. This analytical method was applicable to determine the tar color additives contained in several commercial cold syrups.

SIMS 분석조건이 Bismuth Titanate 박막의 깊이방향 조성 해석에 미치는 영향 (Effect of Surface Charging on the SIMS Depth Profile of Bismuth Titanate Thin Film)

  • 김재남;이상업;권혁대;신광수;전웅;박병옥;조상희
    • 분석과학
    • /
    • 제14권6호
    • /
    • pp.486-493
    • /
    • 2001
  • 본 연구는 SIMS를 이용한 bismuth titanate 박막의 깊이방향 분석에 있어서 mesh grid를 사용한 경우와 사용하지 않은 경우, offset voltage를 사용한 경우와 사용하지 않은 경우 등 분석조건에 따른 charging effect 그리고 검출한계의 특성을 검토하고자 하였다. 결과에 따르면 -40 V의 offset voltage를 사용하였을 경우는 charging effect의 감소는 물론 검출한계도 낮출 수 있었으나 mesh grid를 사용하였을 경우에는 charging effect는 다소 줄일 수 있었으나 반면 검출 한계는 오히려 높아졌다. O- 일차이온을 적용한 경우는 -40 V의 offset voltage를 사용하였을 때와 동일한 효과를 얻을 수 있었다.

  • PDF

보조 형광증가제를 이용한 L-Dopa의 형광분광법적 정량 (Determination of L-Dopa by Spectrofluorimetry Using Co-fluorescence Enhancer)

  • 이상학;안정미
    • 대한화학회지
    • /
    • 제44권6호
    • /
    • pp.541-546
    • /
    • 2000
  • 리간드 증감 유발 형광법을 이용하여 Tb(III)-L-dopa (L-3,4-dihydroxyphenyl alanine) 착이온의 방출세기를 측정함으로써 수용액 중의 L-dopa를 정량하는 방법에 대하여 연구하였다. 들뜸파장, pH, 보조 형광증가제의 선택, Tb(III) 이온의 농도, 보조 형광증가제로 사용된 Lu(III) 이온의 농도 및 방출파장의 방출세기에 대한 영향을 조사하였다. 보조 형광증가제로서 Lu(III) 이온을 첨가하였을때 Tb(III) 이온의 방출세기가 현저히 증가함을 관찰하였고, L-dopa의 검출한계를 낮출 수 있었다. 보조 형광증가제를 첨가하지 않았을 경우에 L-dopa 검정곡선의 직선감응범위는 들뜸파장, pH 및 Tb(Ⅲ) 이온의 농도가 각각 300 nm, 8.0 및 $1.0{\times}10^{-4}$ M였을때, $5.0{\times}10^{-7}$ M~$1.0{\times}10^{-4}$ M였다. 이 조건에서의 검출한계는 $4.0{\times}10^{-8}$ M였다. 보조 형광증가제를 첨가하였을 경우에는 들뜸파장, pH, Tb(III) 이온의 농도, 보조 형광증가제로 사용된 Lu(III) 이온의 농도 및 방출파장이 각각 300 nm, 8.5, $1.0{\times}10^{-5}$ M, $1.0{\times}10^{-5}$ M 및 545 nm였을 때, 직선감응범위가 1.0×$10^{-8}$ M~2.0{\times}10^{-4}$ M였고, 이 때의 검출한계는 $1.0{\times}10^{-9}$ M였다.

  • PDF

$Ph_2O_2S_3$로 변성된 탄소반죽전극에 의한 Ag(I) 이온의 전압-전류법적 정량 (Voltammetric Determination of Ag(I) ion using Carbon Paste Electrode Modified with $Ph_2O_2S_3$)

  • 이인종
    • 분석과학
    • /
    • 제12권2호
    • /
    • pp.171-175
    • /
    • 1999
  • Carbon paste electrodes, modified with podands containing more than two sulfur atoms, have been employed for the voltammetric determination of Ag(I) ion from aqueous solution. The voltammetric response was characterized with respect to paste composition, preconcentration method, kind of anion, variation of pH, Ag(I) ion concentration, and possible interferences. Linear calibration curves were obtained for Ag(I) ion concentration ranging from $1.0{\times}10^{-6}$ to $9.0{\times}10^{-5}M$, and detection limit was $5.0{\times}10^{-7}M$.

  • PDF

주게원자로 산소와 질소를 포함하는 거대고리 리간드로 변성된 탄소반죽전극에 의한 Ag(I) 이온의 전압-전류법적 정량 (Voltammetric Determination of Ag(I) ion with Carbon Paste Electrode Modified with Macrocyclic Ligand Containing Oxygen and Nitrogen as Ligating Atoms)

  • 이인종
    • 분석과학
    • /
    • 제15권1호
    • /
    • pp.91-95
    • /
    • 2002
  • Carbon paste electrodes, modified with 5,6,14,15-dibenzo-1,4-dioxa-8,12-diazacyclopentadeca-5,14-diene containing different ligating atoms of oxygen and nitrogen, have been employed for the voltammetric determination of Ag(I) ion from aqueous solution. The voltammetric response was characterized with respect to paste composition, preconcentration method, kind of anion, variation of pH, Ag(I) ion concentration, and possible interferences. Linear calibration curves were obtained for Ag(I) ion concentration ranging from $3.0{\times}10^{-6}M$ to $8.0{\times}10^{-5}M$, and detection limit was $8.5{\times}10^{-7}M$.

Synthesis of Allyl Functionalized Silacrown Ethers and Their Application - A Review

  • Haque, Md Hasanul;Sohn, Honglae
    • 통합자연과학논문집
    • /
    • 제13권2호
    • /
    • pp.41-46
    • /
    • 2020
  • A study is reported about the synthesis processes of various silacrown ether by the reaction of alkoxysilanes with polyethylene glycols (PEG) through transesterification. Crown ether-functionalized carbosilane dendrimers and hybrid crown ethers are also discussed. We will also address the solubility enhancement, phase-transfer catalysis of different silacrown as well as their application as Ion-selective electrodes (ISEs) and as active phase of PVC electrodes for the development of potentiometric sensors for detection of alkali-Ions.