• Title/Summary/Keyword: Junction Area

Search Result 341, Processing Time 0.032 seconds

A Study on the Changes of Vertical height in Teeth and Alveolar Bone with Age (증령에 따른 치아 및 치조골의 고경 변화에 관한 연구)

  • Se-Sook Kang;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.13 no.1
    • /
    • pp.13-21
    • /
    • 1988
  • The author studied the vertical height of tooth crown and the amounts of alveolar bone resorption with age. All 84 subjects(44 male, 40female) who visited Dental hospital of Wonkwang University with no history of sever periodontal disease and no experience of periodontal surgery. 84 subject were divided into 3 groups by age, that is, group I(28-32yrs), group II(38-42yrs), and group III(48-52yrs). Informal radiogram with bite wing film(horizontal angulation : $0^{\circ}$, vertical angulation : $+5^{\circ}~+10^{\circ}$) were taken on premolar and molar area. The distances from cusp tip to cementoenamel junction (vertical height of tooth crown) and from cementoenamel junction alveolar crest(amount of alveolar bone resorption) were measured, and then recorded data from 946 teeth were statistically analysed. This study was undertaken to obtain the data for age estimation by the changes of tooth crown height and alveolar bone resorption in the point of forensic odontology. The obtained results were as follows : 1. The average crown height of mandibular right 1st. molar was 7.1mm in group I, 6.7mm in group II, and 6.6mm group III, and the average amount of alveolar bone resorption on mandibular right 1st. molar were 1.8mm in group I, 2.5mm in group II, and 3.0mm in group III. Ratio of tooth crown height to amount of alveolar bone resorption was 4.0:1 in groupI, 2.7:1 in group II, and 2.2:1 in group III, the ratio was decreased with age. 2. In comparison with upper teeth and lower teeth in ipsilateral side, the average value of tooth crown height and amount of alveolar bone resorption were slightly higher in upper arch than those in lower arch, but there was not a statistically significant difference. 3. The ratio of height of tooth crown to amount of alveolar bone resorption was decreased with age, and which depended mainly upon the change of amount of alveolar bone resorption rather than the change of tooth crown height.

  • PDF

A Study on the Device Characteristics of NMOSFETs Having Elevated Source/drain Made by Selective Epitaxial Growth(SEG) of Silicon (실리콘 선택적 결정 성장 공정을 이용한 Elevated Source/drain물 갖는 NMOSFETs 소자의 특성 연구)

  • Kim, Yeong-Sin;Lee, Gi-Am;Park, Jeong-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.3
    • /
    • pp.134-140
    • /
    • 2002
  • Deep submicron NMOSFETs with elevated source/drain can be fabricated using self-aligned selective epitaxial growth(SEG) of silicon for enhanced device characteristics with shallow junction compared to conventional MOSFETs. Shallow junctions, especially with the heartily-doped S/D residing in the elevated layer, give hotter immunity to Yt roll off, drain-induced-barrier-lowering (DIBL), subthreshold swing (SS), punch-through, and hot carrier effects. In this paper, the characteristics of both deep submicron elevated source/drain NMOSFETs and conventional NMOSFETs were investigated by using TSUPREM-4 and MEDICI simulators, and then the results were compared. It was observed from the simulation results that deep submicron elevated S/D NMOSFETs having shallower junction depth resulted in reduced short channel effects, such as DIBL, SS, and hot carrier effects than conventional NMOSFETs. The saturation current, Idsat, of the elevated S/D NMOSFETs was higher than conventional NMOSFETs with identical device dimensions due to smaller sheet resistance in source/drain regions. However, the gate-to-drain capacitance increased in the elevated S/D MOSFETs compared with the conventional NMOSFETs because of increasing overlap area. Therefore, it is concluded that elevated S/D MOSFETs may result in better device characteristics including current drivability than conventional NMOSFETs, but there exists trade-off between device characteristics and fate-to-drain capacitance.

Generation of 3D Building Model by Grouping of 3D Line Segments (3차원 선소의 Grouping에 의한 3차원 건물 모델 발생)

  • Kang, Yon-Uk;Woo, Dong-Min
    • Journal of IKEEE
    • /
    • v.10 no.1 s.18
    • /
    • pp.40-48
    • /
    • 2006
  • This paper presents a new rooftop surface estimation method from 3D line segments. 3D rooftop surface estimation is based on the hierarchical grouping and initiated by 3D line merging for the disconnected 3D line segments. Merged 3D lines are applied to the detection of rooftop by surface estimating technique. To estimate surfaces we detect L-corner and T-corner points, and find fixed reliable junction points. The hypothesis of the possible rooftop surfaces are estimated as polygonal surfaces by these fixed junction points and building's rooftop models are generated by testing the possible surfaces in terms of assumptions of building surface properties. We carried out experiments by synthetic images on Avenches data set and the experimental results showed that we could reliably build 3D model with 3D surfaces, errors of which came up with 0.4 - 1.3 meter, 2.5 times more accurate than the elevation date from the conventional area-based stereo.

  • PDF

Fabrication and Characteristics of 300V Mo-MPS Rectifier (300V용 Mo-MPS 정류기의 제조 및 그 특성)

  • 최형호;박근용;김준식;최시영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.6
    • /
    • pp.393-399
    • /
    • 2003
  • The current paper presents a new Mo-MPS rectifier using molybdenum as barrier metal to improve on the low forward voltage drop and power dissipation of the coventional Al-MPS and Pt-MPS rectifier. Electrical characteristics of the fabricated Mo-MPS rectifier are imvestigated compared with Al-MPS and Pt-MPS rectifier. At the same current level, the forward voltage drop of the Mo-MPS was reduced by 0.11V~0.24V compared to that of the conventional MPS rectifier. Accordingly, since the Power dissipation of a rectifier mostly depends on the forward current density and forward voltage drop, the Mo-MPS rectifier achieved improved power dissipation when compared to the conventional MPS rectifier. The reverse breakdown voltage of a Mo-MPS rectifier with 68% Schottky junction area was about 304y. Despite having a lower forward voltage drop than a conventional MPS rectifier, the Mo-MPS rectifier still exhibited a higher reverse breakdown voltage.

Impact of Pig Slurry from WangGoong Farm Cluster on Water Quality of the Iksan Stream

  • Choi, Hong-Lim;Suresh, A.;Babu, T.;Mansyur, Mansyur
    • Journal of Animal Science and Technology
    • /
    • v.53 no.6
    • /
    • pp.549-561
    • /
    • 2011
  • Livestock wastewater is being discharged without treatment from Hasen's pig farm cluster in WangGoong (WG) area into the Iksan Stream, eventually flowing into the ManGyung (MG) at the upstream junction. Although it is well known that before discharge, wastewater must satisfy the pig slurry discharge standards; because of ongoing remodeling, proper treatment is not being performed. According to public records, wastewater from the WG pig farm cluster is responsible for 3.6% of MG River pollution and 2.0% of the SaeManGuem (SMG) Reservoir pollution. As a result, upstream water treatment quality has become primary concern for development of the SMG project. All physicochemical constituents and pathogenic microbes, such as chemical oxygen demand ($COD_{Cr}$), biochemical oxygen demand ($BOD_5$), total suspended solids (TSS), total nitrogen (TN), total phosphorous (TP), fecal coliforms, Escherichia coli and Salmonella at the effluent of WG Plant (S-1) exceed the effluent standards. This is mainly due to insufficient wastewater treatment: the WG Plant is under renovation to increase water purification efficiency. By comparing the water quality at the S-7 junction, where the the Iksan Stream (pig farms) and the Wanggoong Stream (no pig farms) merge, it is clear that farming facilities and improper treatment can critically affect surrounding water quality. While it is clear throughout this study that the level of all physicochemical parameters and pathogenic microbes along the Stream decreased due to sedimentation, biodegradation and/or dilution. An alarming problem was discovered: the existence of pathogenic microbe count(E coli, Salmonella) in the lagoon wastewater and the stream water. Not only were high concentrations of these pathogens themselves found, but the potential existence of more serious pathogens could rise to more dangerous conditions.

Investigation on Water Quality Variation Characteristics during Dry Season in Namhan River Drainage Basin (남한강수계 저수기 수질변동 특성에 관한 연구)

  • Lee, H.J.;Kong, D.S.;Kim, S.H.;Shin, K.S.;Park, J.H.;Kim, B.I.;Kim, S.M.;Jang, S.H.;Cheon, S.U.
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.889-896
    • /
    • 2007
  • From the direct outflow of Chungju Dam to the junction of water body and watershed in Paldang lake is the scope of this research. This study performed to investigate the main cause of water quality deterioration and the influenced region in the middle field range of the Namhan river Basin with the onsite measurement of water quality and flow rate simultaneously during spring dry season. The purpose of this study is to find out the time-spatial variation characteristics of water quality and flow rate. Following the flow direction $BOD_5$ and $COD_{Mn}$ concentration increased to the highest value of 3.7 mg/L, 5.9 mg/L at Wolgesa respectively. Chl.a concentration increased to $50mg/m^3$ or so at Kangsang, after that it decreased to $37mg/m^3$ at the junction of Paldang lake. Organic matter concentration variation trend showed similar than that of Chl.a. Also $BOD_5$ concentration tendency was similar to Chl.a in every measuring sites except Paldang lake mixing zone. The major factors of water quality deterioration in Namhan river and Paldang lake during dry season were algal bloom and followed internal production. High phosphorus load from Dalcheon and Seom river caused dry season algal bloom and internal production in transitional zone which was stagnant area in downstream of Namhan river.

Analysis of Water Depth and Velocity through Discharge Condition from Sewerage Outlet at Near Channel Junction (하천 합류부 주변내 하수관거 방류조건에 따른 수위 및 유속 영향분석)

  • Chung, Yeon-Jung;Choi, Gye-Woon;Kim, Young-Kyu;Cho, Sang-Wook
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.49-56
    • /
    • 2006
  • The rainfall runoff is drained through sewerage outlet at urban area. But, there is no guideline or standard to install sewerage outlet, so the sewerage outlet are designed or installed by discretion of engineers or constructors. In this paper, for the sake of supporting basic data to design, it would be suggested a guideline for less influenced to flow at the channel flow condition through hydraulic experiment by variation of lateral inflow discharge, sewerage outlet projecting part, sewerage outlet direction and position. Through 10 cases of experiments, it would be less influenced two sewerage outlet at up and down stream than one installed at up or down stream even though the same discharge. And installed conditions which are installed angle and protecting part will be influenced to increase water depth and to decrease velocity at upstream. So when sewerage outlet is installed, it would be try to find a installing way to be less influence with more careful.

Evaluation of Inland Inundation Risk in Urban Area using Fuzzy AHP (Fuzzy AHP 기법을 이용한 도시지역의 내수침수위험도 평가)

  • Shin, Ji Yae;Park, Yei Jun;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.9
    • /
    • pp.789-799
    • /
    • 2014
  • This study presented how to evaluate the inland inundation risk considering the characteristics of inland flood. Fuzzy AHP (Analytic Hierarchy Process), which can deal with the uncertainty or ambiguousness of the decision-making process, was used to estimate the inundation risk. The criteria used for inland inundation risk include the physical index, social index and inland flood. Each index contains three detailed indicators then total nine indicators were employed in this study. The inundation risk evaluation was carried out for each node (manhole) within the drainage system, not to the administrative extent, which enabled us to point out nodes with high risk. The proposed Fuzzy AHP was applied to Geoje district in Busan. The results indicated that the junction of Oncheoncheon and Geojecheon has high risk which is consistent with the fact that this junction has already experienced floods in the past. The proposed method can be used for evaluating inland inundation risk and preparing flood prevention plans in inland flood-prone urban areas.

$NiFe/Co/Al_2O_3/Co/IrMn$ 접합의 터널링 자기저항효과

  • 홍성민;이한춘;김택기
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.6
    • /
    • pp.291-295
    • /
    • 1999
  • $NiFe/Co/Al_2O_3/Co/IrMn$ tunneling junctions were grown on (100)Si wafer and their spin-valve tunneling magnetoresistance (TMR) was studied. The tunneling junctions were grown by using a 5-gun RF/DC magnetron sputter. $Al_2O_3$ barrier layer was formed by exposing Al layer to oxygen atmosphere at 6$0^{\circ}C$ for 72 hours. Strong exchange coupling interaction is observed between the ferromagnetic Co and the antiferromagnetic IrMn of Co/IrMn bilayer when IrMn is 100$\AA$ thick. $NiFe(183\;{\AA})/Co(17\;{\AA})/Al_2O_3(16\;{\AA})/Co(100\;{\AA})/IrMn(100\;{\AA})$ tunneling junction shows best TMR ratio of about 10% in the applied magnetic field range of $\pm$20 Oe. The TMR ratio is improved about 23% and electrical resistance is decreased about 34% when annealed at 200 $^{\circ}C$ for 1 hour in magnetic field of 330 Oe, parallel to the bottom electrode. With increasing the active area of junction the TMR ratio increases while electrical resistance decreases.

  • PDF

RELAP5/MOD3 Analysis for Hydraulic Load Calculation of the SEBIM POSRV Discharge Riping System (SEBIM POSRV 방출배관계통의 수력학적 하중계산을 위한 RELAP5 / MOD3 분석)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.225-236
    • /
    • 1994
  • The sudden discharge of the loop seal water, which is present upstream of the SEBIM POSRV, creates large momentum and inertia forces on the downstream of the discharge piping system. This study provides the procedures and results of analysis of the thermal-hydraulic transient in the SEBIM POSRV discharge piping during the valve opening. The analysis is peformed by RELAP5/MOD3. The appropriate modeling of the discharge piping system, SEBIM POSRV opening characteristics, and loop seal water discharge for the RELAP5/MOD3 analysis is suggested. Also performed is the sensitivity study for the selection of proper options for the junction and volume control. flags. The analysis results demonstrate the adequacy of the RELAP5/HOD3 for the thermal-hydraulic transient analysis of the loop seal water discharge of the SEBIM POSRV discharge piping system. From the sensitivity analysis results, it is shown that the smooth area change option with reasonable geometric pressure drop distribution, non-equilibrium option, and proper time step should be selected for loop seal water discharge analysis.

  • PDF