• Title/Summary/Keyword: Junction's Condition

Search Result 66, Processing Time 0.022 seconds

A Study on the Detection of Interfacial Defect to Boundary Surface in Semiconductor Package by Ultrasonic Signal Processing (초음파 신호처리에 의한 반도체 패키지의 접합경계면 결함 검출에 관한 연구)

  • Kim, Jae-Yeol;Hong, Won;Han, Jae-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.369-377
    • /
    • 1999
  • Recently, it is gradually raised necessity that thickness of thin film is measured accuracy and managed in industrial circles and medical world. Ultrasonic signal processing method is likely to become a very powerful method for NDE method of detection of microdefects and thickness measurement of thin film below the limit of ultrasonic distance resolution in the opaque materials, provides useful information that cannot be obtained by a conventional measuring system. In the present research. considering a thin film below the limit of ultrasonic distance resolution sandwiched between three substances as acoustical analysis model, demonstrated the usefulness of ultrasonic signal processing technique using information of ultrasonic frequency for NDE of measurements of thin film thickness. Accordingly, for the detection of delamination between the junction condition of boundary microdefect of thin film sandwiched between three substances the results from digital image processing.

  • PDF

Noise Reduction Characteristic of Total Quiet Pavement System (저소음 포장체의 소음저감 특성)

  • Lee, Kwan-Ho;Park, Woo-Jin
    • International Journal of Highway Engineering
    • /
    • v.14 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • The rapid economic development induced the massive road constructions, becoming bigger and high-speed of the vehicles. However, it brings lots of social problems, such as air pollutions, traffic noise and vibration. Special concrete block for the base course of asphalt pavement is needed to decrease traffic noise such as tire's explosive and vehicles sound, applying Helmholtz Resonators theory to asphalt pavement. If it is applied to the area where it happens considerable noise such as a junction, the street of a housing complex and a residential street, it is one of alternative methods to solve the social requirements of noise problems. This research examines couple of laboratory tests for the sound absorption effect of the concrete block and the base concrete block for quiet pavement. The specimens, which is fixed hall-size, space, depth as the condition of this research, are analysed of noise reduction effect using different noise levels of vehicles. Judging from the analysis of test results with vehicle noise volume, measurement distance, a form and size of the hall using the base concrete block, the use of special concrete base and quiet asphalt surface showed a good alternative solution for decreasing traffic noise level, from 4dB to 9dB.

Primary Renal Hemangiosarcoma Complicated with Hematuria and Hemoperitoneum in a Dog (개에서 발생한 혈뇨와 복강 내 출혈을 동반한 신장원성 혈관육종)

  • Yeo, Jung-Jin;Sur, Jung-Hyang;Eom, Ki-Dong;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.165-168
    • /
    • 2012
  • A 14-year-old intact male Siberian Husky was presented with hematuria, lethargy, and anorexia of 1-month duration. The physical examination revealed mild abdominal distension and pain. The hematology and serum chemistry revealed anemia and severe azotemia. The radiographic examination revealed renomegaly and the ultrasonographic examination, indistinct cortico-medullary junction, increased renal cortex echogenicity, and irregular margination. The urinalysis showed proteinuria and hematuria. The differential diagnosis included renal failure, cystitis, pyelonephritis, and neoplasia. The patient's condition continued to deteriorate, and the dog eventually died. The gross findings from the necropsy revealed hemoperitoneum and a bilateral renal mass. HSA was diagnosed by histopathological examination. This case report describes primary bilateral renal hemangiosarcoma (HSA), which is uncommon in dogs.

Fabrication of Polymeric Microcapsules in a Microchannel using Formation of Double Emulsion (마이크로채널 내 이중유화 액적 형성을 통한 마이크로캡슐 제조)

  • Nam, Jin-Oh;Choi, Chang-Hyung;Kim, Jongmin;Kang, Sung-Min;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.51 no.5
    • /
    • pp.597-601
    • /
    • 2013
  • In this study, we present simple microfluidic approach for the synthesis of monodisperse microcapsules by using droplet-based system. We generate double emulsion through single step in the microfluidic device having single junction while conventional approaches are limited in surface treatment for the generation of double emulsion. First, we have injected disperse fluid containing FC-77 oil and photocurable ethoxylated trimethylolpropane triacrylate (ETPTA) and water containing 3 wt% poly(vinyl alcohol) (PVA) as continuous phase into microfluidic device. Under the condition, we easily generate double emulsion with high monodispersity by using flow focusing. The double emulsion droplets are transformed into microcapsules under the UV irradiation via photopolymerization. In addition, we control thickness of double emulsion's shell by controlling flow rate of ETPTA. We also show that the size of double emulsions can be controlled by manipulation of flow rate of continuous phase. Furthermore, we synthesize microcapsules encapsulating various materials for the application of drug delivery systems.

The Photovoltaic Properties & Fabrication of $n^{+}$-p InP Homojunction Diodes ($n^{+}$-p InP 동종접합 다이오드의 제작과 광기전력 특성)

  • 최준영;문동찬;김선태
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1992.05a
    • /
    • pp.110-113
    • /
    • 1992
  • $n^{+}$-p homojunction InP diodes were fabricated using thermal diffusion of Sulfur into p-type InP substrates(Zn doped, LEC grown, p=2.3${\times}$10$^{16}$c $m^{-3}$). The Sulfur diffusion was carried out at 550$^{\circ}C$, 600$^{\circ}C$, 700$^{\circ}C$ for 4 hours in a sealed quartz ampule(~2ml in volume) containing 5mg I $n_2$ $S_3$ and Img of red phosphorus. The formed junction depth was below 0.5$\mu\textrm{m}$. After the removal of diffused layer on the rear surface of the wafer, the beak ohmic contacts to the p-side were made with a vacuum evaporation of An-Zn(2%) followed by an annealing at 450$^{\circ}C$ for 5 minutes in flowing Ar gas. The front contacts were made with a vacuum evaporation of Au-Ge(12%) followed by an annealing at 500$^{\circ}C$ for 3 minutes in flowing Ar gas. The remarkable sprctral response of the cells obtained at the region of 6000-8000${\AA}$ region. The open circuit voltage $V_{oc}$ , short circuit current density $J_{sc}$ , fill factor and conversion efficiency η of the fabricated pattern solar cells(diffusion condition : at 700$^{\circ}C$ for 4 hours) were 0.660V, 14.04㎃/$\textrm{cm}^2$, 0.6536 and 10.09%, respectively.y.

  • PDF

A TEM STUDY OF THE RESIN-DENTIN INTERDIFFUSION ZONE FORMED BY ONE-BOTTLE DENTIN ADHESIVE SYSTEMS (단일용기 상아질 접착제 처리 후 레진-상아질 경계면에 대한 투과전자현미경적 연구)

  • Yang, Dong-Woon;Park, Seong-Ho;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.180-192
    • /
    • 2000
  • One bottle system was recently developed in order to simplify the clinical skills and save chair time after continuous improvements on dentin bonding agents. There has been many studies to measure the bond strength of one bottle systems but no actual work has been done on micromorphologic study of resin-dentin interdiffusion zone after one bottle system application. To evaluate the bonding patterns of various commercially available one bottle systems to dentin, observation of resin-dentin interdiffusion zone under TEM was performed. Caries-free human third molars within one month of extractions were chosen for the experiments. The molars were sectioned 1mm above the cementoenamel junction and got rid of the root portions. Crown portions of the teeth were sectioned parallel to occlusal surface so that dentin discs of 1mm in thickness were remained. 7 one bottle systems and 1 two bottle system were applied according to manufacturer's instructions and followings were the results. 1. In every experimental groups, cross bandings of collagen fiber were distinguishable and tight bon dings between the bonding agents and dentin were observed. 2. Hybrid layer was clearly observed in ONE-STEP$^{(R)}$, Prime & Bond$^{(R)}$ 2.1, Syntac$^{(R)}$ SC, MAC-BOND II groups but it was not clear in Single Bond, D-Liner Dual PLUS, ONE COAT BOND groups. 3. Electron-density of hybrid layer was uniform in pattern in MAC-BOND II, Prime & Bond$^{(R)}$ 2.1 groups but not so uniform in ONE-STEP$^{(R)}$ group. 4. Electron-dense amorphous phase in most superior layer of the resin-dentin interdiffusion zone was characteristically observed in Single Bond, Syntac$^{(R)}$ SC, ONE COAT BOND groups. It can be concluded that bondings between the dentin bonding agents and dentin can be various in pattern according to their chemical compositions and the condition during applications.

  • PDF

Neural Bases of Empathy in Competitive vs. non-Competitive situation (경쟁과 비경쟁 상황에서 공감의 신경학적 기제)

  • Hwang, Su-Young;Yoon, Mi-Sun
    • Korean Journal of Cognitive Science
    • /
    • v.27 no.3
    • /
    • pp.441-467
    • /
    • 2016
  • This fMRI study is aim to investigate effects of competitive environment in cognitive empathic process in human brain. Empathy is known as a crucial factor for human's adaptive behavior in aspects of social cognition and it is almost automatic process, on the other hand competitive situation is psychologically devastated environment to win someone for getting rewards. We hypnotized that reading and understanding of other person's mind are a specific characteristic related to survival evolutionarily, however competition would have an effect on the empathic cognitive process because of mechanisms of competition. To manipulate the competitive atmosphere, one researcher took a role of competitor against participants and they were instructed to get monetary rewards when their performance was better than a competitor. 21 participants(9 males and 12 females) performed to judge the emotional valence of the empathic task consisted of illustrated images with various situation could be experienced in real world as on $1^{st}$ person perspective in both competitive and non-competitive condition, and did same performance with objects stimulus in control condition. In order to examine the competition effects on empathic process,, hemodynamic response were obtained during fMRI session and the imaging data were analyzed to identify brain regions where responses to each condition across the two consecutive runs. Participants' reaction time in competitive condition was faster statistically significant than non-competitive one. Activation for competitive condition increased in the following areas: ACC, mPFC, SMG, thalamus extended caudate and Nacc, parahippocampal gyrus, and for non-competitive condition increased paracingulate gyrus, temporal pole, vmPFC, superior occipital gyrus. As a result of regression analysis using empathic scores as covariance, the rSMG, IFG, fusiform gyrus, thalamus, putamen were correlated with higher empathic levels, and TPJ were correlated with lower empathic scores. We suggest that these observations could mean competitive environment have an effect on neural base of cognitive empathic process.

Development of Base Concrete Block for Quiet Pavement System (저소음 포장용 기층 콘크리트 블록 개발)

  • Lee, Kwan-Ho;Park, Woo-Jin;Kim, Kwang-Yeom
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 2010
  • The rapid economic development induced the massive road constructions, becoming bigger and high-speed of the vehicles. However, it brings lots of social problems, such as air pollutions, traffic noise and vibration. Special concrete block for the base course of asphalt pavement is needed to decrease traffic noise such as tire's explosive and vehicles sound, applying Helmholtz Resonators theory to asphalt pavement. If it is applied to the area where it happens considerable noise such as a junction, the street of a housing complex and a residential street, it is one of considerable method to solve the social requirements of noise problem. This research examines couple of laboratory tests for the sound absorption effect of the concrete block and the base concrete block. There are specimens which is fixed hall-size, space, depth as the condition of this research, and these are analysed of noise decrease effect using different condition of the first noise of each vehicle. As a result of analysis data according to vehicle noise volume, measurement distance, a form and size of the hall using the base concrete block, the use of special concrete base showed a good alternative solution for decreasing traffic noise level, from 4 dB to 9 dB.

Total Body Irradiation for MyastHenia Gravis with Thvmoma - Case Report - (흉선종을 동반한 중증근무력증 환자에서 전신 방사선치료)

  • Kang, Ki-Mun;Choi, Ihl-Bohng;Kim, In-Ah
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.146-150
    • /
    • 1999
  • Myasthenia gravis (MG) is relatively rare ouuring as one of important autoimmune disease to affect neuromuscular junction. This study was clinically to evaluate total body irradiation (TBI) against two patients including 33-year and 39-year females for chronic MG with thymoma who hospitalized in the St. Mary's Hospital, Catholic University since 1994 as well as who showed no response by thymectomy, immunotherapy and hormonal therapy. TBI designed by the dose of 150$\~$180 cGy consisting of 10 cGy per fraction, three times a week, for 5~e weeks using linear accelerator of 6 MV. During the treatment of TBI, they did complain acute side effect such as vomiting and also appear improved physical condition from 4$\~$6 weeks after TBI. Through the follow-up period of 18 or 42 months after TBI, they did not have any symptomatic recurrence. Consequently, the results suggest that TBI can be used as an alternative tool for the patients concurrently for MG with thymoma who had been refractory to various conventional therapies like thymectomy, immunotherapy and hormonal therapy.

  • PDF

Spontaneous bone regeneration after surgical extraction of a horizontally impacted mandibular third molar: a retrospective panoramic radiograph analysis

  • Kim, Eugene;Eo, Mi Young;Nguyen, Truc Thi Hoang;Yang, Hoon Joo;Myoung, Hoon;Kim, Soung Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.4.1-4.10
    • /
    • 2019
  • Background: The mandibular third molar (M3) is typically the last permanent tooth to erupt because of insufficient space and thick soft tissues covering its surface. Problems such as alveolar bone loss, development of a periodontal pocket, exposure of cementum, gingival recession, and dental caries can be found in the adjacent second molars (M2) following M3 extraction. The specific aims of the study were to assess the amount and rate of bone regeneration on the distal surface of M2 and to evaluate the aspects of bone regeneration in terms of varying degree of impaction. Methods: Four series of panoramic radiographic images were obtained from the selected cases, including images from the first visit, immediately after extraction, 6 weeks, and 6 months after extraction. ImageJ software® (NIH, USA) was used to measure linear distance from the region of interest to the distal root of the adjacent M2. Radiographic infrabony defect (RID) values were calculated from the measured radiographic bone height and cementoenamel junction with distortion compensation. Repeated measures of analysis of variance and one-way analysis of variance were conducted to analyze the statistical significant difference between RID and time, and a Spearman correlation test was conducted to assess the relationship between Pederson's difficulty index (DI) and RID. Results: A large RID (> 6 mm) can be reduced gradually and consistently over time. More than half of the samples recovered nearly to their normal healthy condition (RID ≤ 3 mm) by the 6-month follow-up. DI affected the first 6 weeks of post-extraction period and only showed a significant positive correlation with respect to the difference between baseline and final RID. Conclusions: Additional treatments on M2 for a minimum of 6 months after an M3 extraction could be recommended. Although DI may affect bone regeneration during the early healing period, further study is required to elucidate any possible factors associated with the healing process. The DI does not cause any long-term adverse effects on bone regeneration after surgical extraction.