• Title/Summary/Keyword: Journal of Korean Surgical Society

Search Result 8,500, Processing Time 0.038 seconds

Superciliary Keyhole Approach for Unruptured Anterior Circulation Aneurysms : Surgical Technique, Indications, and Contraindications

  • Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.5
    • /
    • pp.371-374
    • /
    • 2014
  • Neurosurgeons have been trying to reduce surgical invasiveness by applying minimally invasive keyhole approaches. Therefore, this paper clarifies the detailed surgical technique, its limitations, proper indications, and contraindications for a superciliary keyhole approach as a minimally invasive modification of a pterional approach. Successful superciliary keyhole surgery for unruptured aneurysms requires an understanding of the limitations and the use of special surgical techniques. Essentially, this means the effective selection of surgical indications, usage of the appropriate surgical instruments with a tubular shaft, and refined surgical techniques, including straightforward access to the aneurysm, clean surgical dissection, and the application of clips with an appropriate configuration. A superciliary keyhole approach allows unruptured anterior circulation aneurysms to be clipped safely, rapidly, and less invasively on the basis of appropriate surgical indications.

A Study on Wearing and Manufacturing of Surgical Gowns (수술가운의 생산 및 착용현황에 관한 연구)

  • 박상희
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.3
    • /
    • pp.65-71
    • /
    • 2004
  • Surgical operating gowns are worn by doctors and nurses in operating theater to address dual function of preventing transfer microorganisms like bacteria and body fluids from the operating staffs to patients. and also from patients to staff. They must allow necessary mobility without rubbing and must resist tearing. These gown must be designed to fit a diversity of body shapes and sizes with a limited range of sizes as hospitals will stock limited quantities. Also they must proper in various operating situations. In order to suggest improving design features of surgical gowns, it has been done to analyze current situation of medical uniform manufacturing and wearing. Surgical gown were made with plain fabric of cotton 100% and had a little size system without sexual division. Many doctors were unsatisfied with surgical gown size and wearing comfort. Surgical operating gowns need continuos research for new material and design as surgical situation, and new sizing system.

Surgical Treatment for Trigeminal Neuralgia

  • Park, Chang Kyu;Park, Bong Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.615-621
    • /
    • 2022
  • Various treatments for trigeminal neuralgia (TN) are known to yield initial satisfactory results; however, the surgical treatment has excellent long-term outcomes and a low recurrence rate. Surgical treatment addresses the challenge of vascular compression, which accounts for 85% of the causes of TN. As for surgical treatment for TN, microvascular decompression (MVD) has become the surgical treatment of choice after Peter J. Jannetta reported the results of MVD surgery in 1996. Since then, many studies have reported a success rate of over 90% for the initial surgical treatment. Most MVDs aim to separate (decompress) the culprit vessel from the trigeminal nerve. To increase the success rate of surgery, accurate indications for MVD and management of the offender vessels without complications are critical. In addition, if there is no vascular compression, partial sensory rhizotomy or internal neurolysis can be performed to improve surgical outcomes.

Computer Integrated Surgical Robot System for Spinal Fusion

  • Kim Sungmin;Chung Goo Bong;Oh Se Min;Yi Byung-Ju;Kim Whee Kuk;Park Jong Il;Kim Young Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.265-270
    • /
    • 2005
  • A new Computer Integrated Surgical Robot system is composed of a surgical robot, a surgical planning system, and an optical tracking system. The system plays roles of an assisting surgeon and taking the place of surgeons for inserting a pedicle screw in spinal fusion. Compared to pure surgical navigation systems as well as conventional methods for spinal fusion, it is able to achieve better accuracy through compensating for the portending movement of the surgical target area. Furthermore, the robot can position and guide needles, drills, and other surgical instruments or conducts drilling/screwing directly. Preoperatively, the desired entry point, orientation, and depth of surgical tools for pedicle screw insertion are determined by the surgical planning system based on CT/MR images. Intra-operatively, position information on surgical instruments and targeted surgical areas is obtained from the navigation system. Two exemplary experiments employing the developed image-guided surgical robot system are conducted.

Aneurysm of the Posterior Inferior Cerebellar Artery: Clinical Features and Surgical Results

  • Rhim, Jong-Kook;Sheen, Seung-Hun;Oh, Sung-Han;Noh, Jae-Sub;Chung, Bong-Sub
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.6
    • /
    • pp.399-404
    • /
    • 2005
  • Objective: Aneurysms arising from the posterior inferior cerebellar artery(PICA) are uncommon. We review literature on that and surgical results on aneurysmal treatment by choice of surgical approach. Methods: On the basis of radiologic findings & charts, we review retrospectively the surgical results of 12 cases from Mar 1999 to Dec 2003. Results: The mean age of the 12 patients was 55.8(ranged from 36 to 71) and female was predominant (female:male = 8:4). Locations of PICA aneurysms revealed variously(vertebral artery - PICA junction: 8, lateral medullary segment: 2, PICA - anterior inferior cerebellar artery common trunk: 1, telovelomedullary : 1). Surgical approaches & treatments were attempted in 11 cases and embolization was done in 1 case(Far lateral transcondylar or supracondylar approach & clipping: 9, Far lateral transcondylar or supracondylar approach and trapping: 2, suboccipital approach & clipping: 1). The surgical result were 8 of 12 patients were good outcome, 1 of 12 was severely disabled and 3 of 12 were died. Conclusion: First, we choose surgical approach by the laterality of aneurysms and surgical or interventional treatment is attempted as soon as possible. The PICA aneurysm is regarded as having a relatively good surgical outcome without drilling of the posterior arch of the atlas.

Effect of the Exchange of Saline Used in Surgical Procedures on Surgical Site Infection (수술에 사용하는 생리식염수의 교환이 수술부위감염에 미치는 효과)

  • 조옥연;윤혜상
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.3
    • /
    • pp.467-476
    • /
    • 2004
  • Purpose: The purpose of this study was to identify the effect of the exchange of saline used in surgical procedures on surgical site infections. Method: Patients with stomach cancer were assigned to the experimental group or to the control group by random sampling, respectively. The experimental group received an exchange of saline during the operation right after the excision of the stomach in a gastrectomy but the control group did not. Data were collected from the medical charts of 34 patients from Dec. 1, 2002 through May 31, 2003. Result: The surgical site infection rate of the experimental group was 5.9% while surgical site infection rate of the control group was 17.6%. In total, the surgical site infection rate was 11.8%. The experimental group maintained a normal level of WBC on post operative day 3; however, the control group, showed an increase of WBC on post operative day 3. Conclusion: The exchange of saline used in an operation immediately after the excision of the stomach in a gastrectomy decreases the contamination level of saline used in the operation, and can prevent surgical patients from a surgical site infection.

An Analysis of Cost and Profit of a Nursing Unit using Performance-Based Costing: Case of a General Surgical Ward in a General Hospital (시행기준 원가계산을 적용한 간호단위 원가 및 수익 인식에 관한 연구: 1개 종합병원 일반외과병동 사례를 중심으로)

  • Lim, Ji-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.1
    • /
    • pp.161-171
    • /
    • 2008
  • Purpose: The aim of this study was to analysize net income of a surgical nursing ward in a general hospital. Method: Data collection and analysis was conducted using a performance-based costing and activity-based costing method. Result: Direct nursing activities in the surgical ward were 68, indirect nursing activities were 10. The total cost volume of the surgical ward was calculated at \119,913,334.5. The cost volume of the allocated medical department was \91,588,200.3, and the ward consumed cost was \28,325,134.2. The revenue of the surgical nursing ward was \33,269,925.0. The expense of a surgical nursing ward was \28,325,134.2. Therefore, the net income of a surgical nursing ward was \4,944,790.8. Conclusion: We suggest that to develop a more refined nursing cost calculation model, a standard nursing cost calculation system needs to be developed.

Development of Air-powered Handpiece for Surgical Operation (외과 수술용 Air-Powered Handpiece 개발)

  • 윤길상;이영훈;허영무;서태일;최길운
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.3
    • /
    • pp.188-193
    • /
    • 2004
  • The purpose of this paper is concerned with a development of an air-powered handpiece for surgical operation. The handpiece is the tool of surgical instruments and it can be used to interchange multiple attachments for drilling, pinning, sawing, driving screws and reaming. Most of domestic medical instruments bring in overseas and the air-powered handpiece imported from foreign countries at 100% too. Therefore we develop new air powered handpiece. we research in 2D and 3D modeling, design of air line, analyze structure. The air-powered handpiece composes of body, power supply air-line, elements for mechanical power transmission, attachment, and surgical tools. The handpiece is developed by several processes that 3D design, machining, heat treatment and coating. The developed handpiece is experimented to confirm check the efficiency.

Supraorbital Keyhole Approach for Intracranial Aneurysms : Transitioning from Concerns to Confidence

  • Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.1
    • /
    • pp.4-13
    • /
    • 2020
  • For surgical minimalism to reduce iatrogenic traumatization, a supraorbital keyhole approach has already been successfully applied to treat many unruptured anterior circulation aneurysms. However, using this minimal approach also raises several technical concerns due to the small cranial opening and cosmetic impact of a facial incision. Yet, such technical limitations can be overcome by using favorable surgical indications, slender surgical instruments, and optimized surgical techniques, while excellent cosmetic outcomes can be achieved using a short skin incision located <1 cm from the supraorbital margin, reconstruction of any bone defects around the bone flap, and meticulous wound closure. Thus, given such reassuring surgical results, in terms of the clipping status, neurological effects, and cosmetic outcomes, any concerns can be transitioned into confidence.

Iatrogenic Delayed Aortic Injury Following a Surgical Stabilization of Flail Chest

  • Seok, Junepill;Cho, Hyun Min;Kim, Seon Hee;Kim, Ho Hyun
    • Journal of Trauma and Injury
    • /
    • v.31 no.3
    • /
    • pp.174-176
    • /
    • 2018
  • Most of aortic injuries after blunt chest trauma usually occur at the aortic isthmus and are identified in the emergency department soon after arrival. Delayed aortic injures by fractured posterior ribs, however, are relatively rare and have been reported only a few times. We recently experienced an iatrogenic descending aortic injury sustained as a result of a direct puncture by a sharp rib end after surgical stabilization of rib fractures.