• 제목/요약/키워드: Joule-Thomson effect

검색결과 12건 처리시간 0.028초

마이크로 충돌제트에서의 냉각 특성 (Cooling perfermance of micro-impinging jet)

  • 홍봉환;황상동;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1717-1723
    • /
    • 2003
  • Experimental study is conducted to investigate the cooling performance of impinging jet from microtube using Joule-Thomson effect to apply practical applications. And also the heat transfer characteristics of a impinging jet itself and the impinging jet with Joule-Thomson effect are tested to make a comparative study of the two different general ideas. For this propose, two kinds of copper microtubes which have 200 tim and 300 tim in inner diameter respectively were tested and $N_2$ was used as a working fluid. In case of impinging jet without Joule-Thomson effect, heat transfer coefficients distributions were similar to those of normal impinging jet. But in impinging jet with Joule-Thomson effect, the heat transfer coefficients decrease as jet-to-surface increases contrary to the case of the normal jet. As a result, much higher heat transfer coefficients are obtained with Joule-Thomson effect than those of the normal jet without J-T effect.

  • PDF

분자동역학 모의실험을 이용한 아르곤 기체의 Joule-Thomson 반전 곡선

  • 송연호;진희정;원난영
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제2회(2013년)
    • /
    • pp.179-191
    • /
    • 2013
  • NPT ensemble을 이용하여 Joule-Thomson 반전 곡선 (Joule-Thomson inversion curve, JTIC)를 구하는 기존의 모의실험 방법들과는 달리, 본 연구에서는 NVT 분자동역학 모의실험을 이용하여 JTIC를 구하는 방법을 개발하고, 이 방법을 이용하여 아르곤 기체의 JTIC를 구할 수 있음을 보인다. 본 연구 결과를 실험 및 다른 이론들과 비교, 분석한 결과, 낮은 온도에서의 JTIC는 실험 및 이론 결과와 유사한 반면, 높은 온도에서는 일정 정도의 차이를 나타냄을 알 수 있다. 이 차이는 분자동역학 모의실험에 사용하는 적은 입자 수와 모의실험 시간, 그리고 curve fitting 방법 등에 기인하는 것으로 여겨진다. 또한 본 연구를 통하여 NVT 분자동역학 모의실험 방법만 가능한, EDISON 계산화학 프로그램 중 하나인 "Mixed LJ(12-6) particles MD"가 JTIC를 구하는데 유용하게 사용될 수 있고, 이를 통해 학부생들이 열역학의 기본 개념을 이해하는데 도움을 줄 것으로 기대한다.

  • PDF

Joule-Thomson 효과를 고려한 천연가스 배관내의 온도 변화 (Temperature Variations in the Natural Gas Pipeline with the Joule-Thomson Effect)

  • 김윤제
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 1997년도 추계학술발표회 논문집
    • /
    • pp.14-19
    • /
    • 1997
  • A numerical method for determining the temperature vartiation in a natural gas transmission line is presented. By considering an element of the gas pipeline and assuming radially lumped heat transfer at steady-state conditions, the energy equation is developed. The integration of the developed nonlinear differential equation is done numerically using the fourth order Runge-Kutta scheme. The results of the present study have been compared with the results of Coulter equations, and show a fairly good agreement.

  • PDF

극한지 장거리 천연가스 배관의 운전조건 평가 (Evaluation of Operating Conditions for the Natural Gas Transmission Pipeline in the Arctic Environment)

  • 김영표;김호연;김우식
    • 한국가스학회지
    • /
    • 제21권1호
    • /
    • pp.72-79
    • /
    • 2017
  • 극한지 천연가스 배관의 운전온도 범위는 가스 공급을 최적화하고 운전동안 극한지 환경에 대한 충격을 최소화하기 위해 기본적으로 제어되어야 한다. 배관에 흐르는 가스의 온도는 Joule-Thomson 효과와 배관과 토양의 열전달에 의존한다. 따라서 본 연구에서는 매설 천연가스 배관의 열전달과 Joule-Thomson 효과를 상세히 고려하였다. 토양온도는 $0{\sim}-20^{\circ}C$, 총괄열전달계수는 $0{\sim}5.5W/m^2K$로 가정하였다. 토양온도와 총괄열전달계수 변화에 따른 배관 길이방향의 가스온도 변화와 압력손실을 동시에 계산하였다. 또한, 본 연구에서는 HYSYS 프로그램을 사용하여 토양온도와 총괄열전달계수에 따른 상변화와 하이드레이트 생성을 예측하였다.

보텍스튜브에서 랭퀴-힐쉬효과와 줄-톰슨효과가 에너지분리에 미치는 영향 (The Influence of Ranque-Hilsch Effect and Joule-Thomson Effect to Energy Separation in a Vortex Tube)

  • 유갑종;방창훈;김병하
    • 설비공학논문집
    • /
    • 제12권8호
    • /
    • pp.703-710
    • /
    • 2000
  • Energy separation characteristic occurring in a counterflow vortex tube was studied experimentally, where air, $C_2$, and R22 were used as working fluids. The experiments were carried out with pressure ratio from 3 to 8 and cold mass fraction(y) from 0.1 to 0.9. As results, Ranque-Hilsch effect showed different results from adiabatic expansion process. Temperature difference in vortex tube outlet was affected by Joule-Thomson effect as well as Ranque-Hilsch effect. The more effective the energy separation was, the more increased the entropy in the cold oulet of vortex tube was.

  • PDF

쥴톰슨냉동기의 열교환기 성능에 관한 연구 (Study of the Performance of the Fin-Tube Heat Exchanger of the Miniature Joule-Thomson Refrigerator)

  • 홍용주;김효봉;박성제;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권1호
    • /
    • pp.55-59
    • /
    • 2009
  • Miniature Joule-Thomson refrigerators have been widely used for rapid cooling of infrared detectors, probes of cryosurgery, thermal cameras, missile homing head and guidance system, due to their special features of simple configuration, compact structure and rapid cool-down characteristics. The thermodynamic performance of J-T refrigerator highly depends on the hydraulic and heat transfer characteristics of the recuperative heat exchanger. The typical recuperative heat exchanger of the J-T refrigerator has the double helical tube and fin configuration. In this study, effectiveness-NTU approach was adopted to predict the thermodynamic behaviors of the heat exchanger for the J-T refrigerator. The thermodynamic properties from the REFPROP were used to account the real gas effects of the gas. The results show the effect of the operating conditions on the performance of the heat exchanger and refrigerator for the given heat exchanger. The influences of mass flow rate and the supply pressure on the effectiveness of heat exchanger and the ideal cooling capacity are discussed in details.

CO2 기반 금형 급속 냉각기술의 수치해석적 연구 (Numerical Analysis of CO2-Based Rapid Mold Cooling Technology)

  • 최재혁
    • Design & Manufacturing
    • /
    • 제17권3호
    • /
    • pp.61-66
    • /
    • 2023
  • In this study, we developed a simulation methodology for a technology that rapidly cools molds by directly spraying them with CO2 in its liquefied gaseous state. Initially, a simulation verification process was conducted using ANSYS Fluent's heat transfer analysis based on temperature values measured in prior research experiments, ensuring a comparable temperature could be calculated. Subsequently, the validated analysis method was employed to evaluate design factors that exert the most significant influence on cooling. An evaluation was conducted based on three factors: part thickness, mold thickness, and the melting temperature of material. Using a full factorial design approach, a total of 27 analyses were completed and subsequently calculated through analysis of means. The impact assessment was carried out based on the temperature values at the product's core. The results indicated that the thickness of the mold had the highest influence, while the melting temperature of material had the least.

모델링 및 시뮬레이션을 통한 수소충전 프로토콜 영향인자 평가 (Evaluation of Influential Factors of Hydrogen Fueling Protocol by Modeling and Simulation)

  • 채충근;강수연;김한나;채승빈;김용규
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.513-522
    • /
    • 2019
  • It is not easy to refuel quickly and safely with 70 MPa hydrogen. This is because the temperature in the vehicle tank rises sharply due to Joule-Thomson effect, etc. Thus protocols such as SAE J2601 in the United States and JPEC-S 0003 in Japan were established. However, they have the problem of over-complexity and lack of versatility by setting the preconditions for hot and cold cases and introducing a number of look-up tables. This study was conducted with the ultimate goal of developing new protocols based on complete real-time communication. Thermodynamic models were made and programs were developed for hydrogen refueling simulations. Simulation results confirmed that there are five parameters in the influencing factors of the hydrogen refueling protocol.

고자기장용 자석을 위한 밀폐순환형 냉각장치 (Closed-Loop Cooling System for High Field Mangets)

  • 최연석;김동락;이병섭;양형석
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권1호
    • /
    • pp.59-64
    • /
    • 2006
  • A closed-loop cryogenic cooling system for high field magnets is presented. This design is motivated by our recent development of cooling system for 21 tesla Fourier Transform ion Cyclotron Resonance (FT-ICR) superconducting magnets without any replenishment of cryogen. The low temperature superconducting magnets are immersed in a subcooled 1.8 K bath, which is connected hydraulically to the 4.2 K reservoir through a narrow channel. Saturated liquid helium is cooled by Joule-Thomson heat exchanger and flows through the JT valve, isenthalpically dropping its pressure to approximately 1 6 kPa, corresponding saturation temperature of 1.8 K. Helium gas exhausted from pump is now recondensed by two-stage cryocooler located after vapor purify system. The amount of cryogenic Heat loads and required mass flow rate through closed-loop are estimated by a relevant heat transfer analysis, from which dimensions of JT heat exchanger and He II heat exchanger are determined. The detailed design of cryocooler heat exchanger for helium recondensing is performed. The effect of cryogenic loads, especially superfluid heat leak through the gap of weight load relief valve, on the dimensions of cryogenic system is also investigated.