• Title/Summary/Keyword: Joule-Heat

Search Result 148, Processing Time 0.022 seconds

Characteristics of ITO/Ag/ITO Hybrid Layers Prepared by Magnetron Sputtering for Transparent Film Heaters

  • Kim, Jaeyeon;Kim, Seohan;Yoon, Seonghwan;Song, Pungkeun
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.807-812
    • /
    • 2016
  • Transparent film heaters (TFHs) based on Joule heating are currently an active research area. However, TFHs based on an indium tin oxide (ITO) monolayer have a number of problems. For example, heating is concentrated in only part of the device. Also, heating efficiency is low because it has high sheet resistance ($R_s$). To address these problems, this study introduced hybrid layers of ITO/Ag/ITO deposited by magnetron sputtering, and the electrical, optical, and thermal properties were estimated for various thicknesses of the metal interlayer. The $R_s$ of ITO(40)/Ag/ITO(40 nm) hybrid TFHs were 5.33, 3.29 and $2.15{\Omega}/{\Box}$ for Ag thicknesses of 10, 15, and 20 nm, respectively, while the $R_s$ of an ITO monolayer (95 nm) was $59.58{\Omega}/{\Box}$. The maximum temperatures of these hybrid TFHs were 92, 131, and $145^{\circ}C$, respectively, under a voltage of 3 V. And that of the ITO monolayer was only $32^{\circ}C$. For the same total thickness of 95 nm, the heat generation rate (HGR) of the hybrid produced a temperature approximately $100^{\circ}C$ higher than the ITO monolayer. It was confirmed that the film with the lowest $R_s$ of the samples had the highest HGR for the same applied voltage. Overall, hybrid layers of ITO/Ag/ITO showed excellent performance for HGR, uniformity of heat distribution, and thermal response time.

Comparative analysis on darcy-forchheimer flow of 3-D MHD hybrid nanofluid (MoS2-Fe3O4/H2O) incorporating melting heat and mass transfer over a rotating disk with dufour and soret effects

  • A.M. Abd-Alla;Esraa N. Thabet;S.M.M.El-Kabeir;H. A. Hosham;Shimaa E. Waheed
    • Advances in nano research
    • /
    • v.16 no.4
    • /
    • pp.325-340
    • /
    • 2024
  • There are several novel uses for dispersing many nanoparticles into a conventional fluid, including dynamic sealing, damping, heat dissipation, microfluidics, and more. Therefore, melting heat and mass transfer characteristics of a 3-D MHD Hybrid Nanofluid flow over a rotating disc with presenting dufour and soret effects are assessed numerically in this study. In this instance, we investigated both ferric sulfate and molybdenum disulfide as nanoparticles suspended within base fluid water. The governing partial differential equations are transformed into linked higher-order non-linear ordinary differential equations by the local similarity transformation. The collection of these deduced equations is then resolved using a Chebyshev spectral collocation-based algorithm built into the Mathematica software. To demonstrate how different instances of hybrid/ nanofluid are impacted by changes in temperature, velocity, and the distribution of nanoparticle concentration, examples of graphical and numerical data are given. For many values of the material parameters, the computational findings are shown. Simulations conducted for different physical parameters in the model show that adding hybrid nanoparticle to the fluid mixture increases heat transfer in comparison to simple nanofluids. It has been identified that hybrid nanoparticles, as opposed to single-type nanoparticles, need to be taken into consideration to create an effective thermal system. Furthermore, porosity lowers the velocities of simple and hybrid nanofluids in both cases. Additionally, results show that the drag force from skin friction causes the nanoparticle fluid to travel more slowly than the hybrid nanoparticle fluid. The findings also demonstrate that suction factors like magnetic and porosity parameters, as well as nanoparticles, raise the skin friction coefficient. Furthermore, It indicates that the outcomes from different flow scenarios correlate and are in strong agreement with the findings from the published literature. Bar chart depictions are altered by changes in flow rates. Moreover, the results confirm doctors' views to prescribe hybrid nanoparticle and particle nanoparticle contents for achalasia patients and also those who suffer from esophageal stricture and tumors. The results of this study can also be applied to the energy generated by the melting disc surface, which has a variety of industrial uses. These include, but are not limited to, the preparation of semiconductor materials, the solidification of magma, the melting of permafrost, and the refreezing of frozen land.

Separation of Soybean Protein by Free-flow Electrophoresis (자유유동 전기이동법에 의한 대두단백질 분리)

  • 한재갑;류화원
    • KSBB Journal
    • /
    • v.10 no.1
    • /
    • pp.63-70
    • /
    • 1995
  • The effect of operating conditions on separation of soybean proteins in a home-made free-flow electrophoresis apparatus was investigated. Measurement of the pH, conductivity, and UV-absorbance(280 nm) were carried out at each run and the purity of the sample was tested with SDS-PAGE analysis. The soybean extract pretreated with Tris and boric acid was mixed with the amino acids composed of glutamic acid, histidine, arginine, glycine(1 mM each) with glycyl-glycine(2mM) and KCl(1mM). When the cellulose acetate was used as a compartment between the electrode and the buffer solution in the cell, pH distribution in the separation cell varied from 3.0 at the anodic side to 8.0 at the cathodic side and had two inflection point. The applied voltage was from 300V to 1000V and the separation was better at a higher voltage but the voltage was limited by the capability of the cooling system due to Joule heat. The proteins focused near the middle of the channel. From the change of pH and conductivity it was found that the ions in the channel moved out to the electrodes through the membrane. In the case when the concentration of the buffer solution was increased 5 times, proteins were focused at 300V. We could not increase up to the ten times of the concentration since the temperature difference between inlet and outlet was more than $25^{\circ}C$ and denaturation of proteins was expected. When ion-exchange membranes were used U-type pH distribution was set up due to the ionic polarization near the membrane. The commercial ampholytes, instead of the mixed amino acids showed not much improvements in purity of the separated sample.

  • PDF

The Structure of Tidal Front in the Earstern Yellow Sea in the Summer of 1982 (1982년 하계 서해안 조석전선의 구조)

  • CHOO Hyo Sang;CHO Kyu Dae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.2
    • /
    • pp.83-91
    • /
    • 1984
  • The formation and structure of tidal front in the eastern part of the Yellow Sea were studied based on the oceanographic data compiled during the periods of $1982{\sim}1983$ and $1966{\sim}1970$. Well-defined fronts occurring in the Yellow Sea in summer mark the boundary between the stratified and vertically mixed regimes. The occurrence of vertically mixed regimes may be interpreted in terms of available turbulent kinematic energy of tidal currents. The tidal frontal regions were determined by horizontal gradients of temperature, salinity and dissolved oxygen, and were verified by water colour and transparency. In summer the tidal fronts were found at depths of $15{\sim}25m$ at about 20 miles from the shore. Potential energy of vortical stratification in the tidal frontal region was 10 $Joule/m^3$. The stratification parameter in the frontal region computed from the numerical tidal model was $S_p=1.0.$ Tidal front is formed in regions with $S_p=1-1.5,$ if surface heat flux are constant. Waters in the stratified region have the layer structures of wind-mixed surface layer, thermocline and tidal-mixed bottom layer. In the vertically mixed region, however, sea water is nearly homogeneous. in winter no distinctive tidal front was seen.

  • PDF

Comparative Study on Numerical Analysis using Co-simulation and Experimental Results for High Frequency Induction Heating on SCM440 Round Bar (연동해석을 통한 SCM440 환봉의 고주파 유도가열 해석 및 실험 비교분석에 관한 연구)

  • Lee, Inyoung;Tak, Seungmin;Pack, Inseok;Lee, Seoksoon
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.3
    • /
    • pp.1-7
    • /
    • 2017
  • The applications of high-frequency induction heating has recently been studied in various industrial fields. In this study, induction heating is applied to a SCM440 specimen that is widely used in industry. The specimen was made up of a cylinder 20 mm in diameter and 160 mm long. An induction heating power supply module was used to generate heat in the cylinder at a high frequency (approximately 85 kHz) for 50 seconds. The temperature of the specimen was measured at the 150 mm length in 5 second intervals. Results such as joule heat and temperature are compared with the numerical model analysis using an electromagnetic-thermal co-simulation technique. The analytical model of the cylinder was modeled by considering the skin effect. The median measured temperature after induction heating was conducted for 50 seconds was $57.65^{\circ}C$, compared to a predicted analytical value of $57.27^{\circ}C$. Thus, the analytical results are in good agreement with the experimental results, and this model can predict the induction heating phenomenon numerically.

Mechanical and Electrical Reliability of Silver Nanowire Film on Flexible Substrate (유연기판 위에 제작된 Silver Nanowire 필름의 기계 및 전기적 신뢰성 연구)

  • Lee, Yo Seb;Lee, Won Jae;Park, Jin Yeong;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.93-99
    • /
    • 2016
  • In this paper, we investigated the mechanical and electrical reliability of silver nanowire (AgNW) films. In particular, the durability and reliability of AgNW films were studied when the AgNW film was subjected to the bending deformation under current flow. The electrical durability of AgNW was evaluated by observing changes in heat generation and current density occurring in AgNW through voltage and current tests. The AgNW film showed a constant resistance change up to a bending radius of 2 mm and 200,000 cycles in the bending fatigue tests. The over-coating layer has an effect of improving the durability of the AgNW film. In the case of AgNW with the over-coating layer, heat was uniformly dissipated on the surface of AgNW film, whereas in the case of AgNW film without the over-coating layer, heat was generated locally. In the bending test under the current flow, the current density of the AgNW film was continuously decreased up to 52.4%. During bending, the AgNW was deformed due to mechanical deformation such as tensile, bending and sliding of the AgNW, consequently contact resistance of the AgNW was increased, leading to a electrical breakdown of AgNW by Joule heating. It was found that the application of the over-coating layer can improve the electrical and mechanical reliability of the AgNW film.

Assessment of Resistance Spot Weldability of Dissimilar Joints of Austenitic Stainless Steels/IF Steels and Ferritic Stainless Steels/IF Steels (페라이트계 및 오스테나이트계 스테인리스강과 IF강의 이종 접합부의 저항 점 용접성 평가)

  • Lee, Jin-Beom;Kim, Dong-Cheol;Nam, Dae-Geun;Kang, Nam Hyun;Kim, Soon-Kook;Yu, Ji-Hun;Rhym, YoungMok;Park, Yeong-Do
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.1
    • /
    • pp.64-72
    • /
    • 2011
  • The spot weldability of dissimilar metal joints between austenitic stainless steels (STS316)/IF steels and ferritic stainless steels (STS430)/IF steels was investigated. This study was aimed to determine the spot welding parameters for a dissimilar metal joint and to evaluate the dissimilar metal joint's weldability, including its welding nugget shape, tensile-shear strength, hardness, and microstructure. The comparison of these results was described in terms of fracture behavior. Compared with the weld lobe of similar metal joints, dissimilar metal joints (STS430/IF) had reduced weld current range. However, the weld lobe of STS316/IF steel joint showed increased weld current range. This is because the dilution of chemical composition in the molten weld pool suppressed the heat input being caused by Joule heat with current flow through the samples. The microstructure of the fusion zone was fully martensite and mixture of ferrite and martensite for austenitic stainless steel/IF steel and ferritic stainless steel/IF steel combination, respectively. The experimental results showed that the shape of nugget was asymmetric, in which the fusion zone of the austenitic and ferritic stainless steel sheet was larger due to the higher bulk-resistance. The predicted microstructure by using the Schaeffler diagram was well matched with experimental results. After peel test, the fracture was initiated from heat affected zone of ferritic stainless steel sheet side, however the final fracture was propagated into the IF steel sheet side due to its lower strength.

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF

Development of the closed-loop Joule-Thomson cryoablation device for long area cooling

  • Lee, Cheonkyu;Park, Inmyong;Yoo, Donggyu;Jeong, Sangkwon;Park, Sang Woo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.3
    • /
    • pp.40-48
    • /
    • 2013
  • Cryoablation device is a surgical instrument to produce the cooling effect to destroy detrimental biological tissue by utilizing low temperature around 110 K. Usually, this device has the concentrated cooling region, so that it is suitable for concentrated and thick target. Accordingly, it is hard to apply this device for the target which is distributed and thin target. In this study, the design procedure of a closed-loop cryoablation device with multiple J-T expansion part is developed for the treatment of incompetent of great saphenous vein. The developed cyoablation device is designed with the analysis of 1-dimensional (1-D) bio-heat equation. The energy balance is considered to determine the minimum mass flow rate of refrigerant for consecutive flow boiling to develop the uniform cooling temperature. Azeotropic mixed refrigerant R410A and zeotropic mixed refrigerant (MR) of R22 ($CHClF_2$) and R23 ($CHF_3$) are utilized as operating fluids of the developed cryoablation device to form the sufficient temperature and to verify the quality of the inside of cryoablation probe. The experimental results of R410A and the zeotropic MR show the temperature non-uniformity over the range are $244.8K{\pm}2.7K$ and $239.8K{\pm}4.7K$ respectively. The experimental results demonstrate that the probe experiences the consecutive flow boiling over the target range of 200 mm.

Design and Analysis of Cryogenic Turbo Expander for HTS Power Cable Refrigeration System (초전도 전력 케이블 냉각 시스템 적용을 위한 극저온 터보 팽창기 설계 및 해석)

  • Lee, Changhyeong;Kim, Dongmin;Yang, Hyeongseok;Kim, Seokho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.3
    • /
    • pp.141-148
    • /
    • 2015
  • The cryogenic cooling system should maintain the HTS power cable below 77 K. As the length of HTS power cables has increased, there have been many efforts to develop large capacity cryocoolers. Brayton, Joule-Thomson, and Claude refrigerators were considered for the large capacity cryocooler. Among the various cryocoolers, the Brayton refrigerator is the most competitive in terms of the HTS power cable. At present, it is thought that a 10-kW class refrigerator will be able to be used as a unit cooling system for the commercialization of HTS power cables in the near future. The Brayton refrigerator is composed of recuperative heat exchangers, a compressor, and a cryogenic turbo expander. Among the various components, the cryogenic turbo expander is the part that decreases the temperature, and it is the most significant component that is closely related with overall system efficiency. It rotates at high speed using high-pressure helium or neon gas at cryogenic temperatures. This paper describes the design of a 300-W class Brayton refrigeration cycle and the cryogenic turbo expander as a downscale model for the practical 10-kW class cycle. Flow and structural analyses are performed on the rotating impeller and nozzle to verify the efficiency and the design performance.