• Title/Summary/Keyword: Joule loss

Search Result 21, Processing Time 0.024 seconds

Calculation of Resistance of Cage Rotor End Ring using 3-D Finite Element Method (3차원 유한요소법을 이용한 농형유도전동기 단락환의 저항계산)

  • Bak, Min-Woo;Lee, Bok-Yong;Jung, Hae-Duk;Lee, Ki-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.92-94
    • /
    • 1995
  • This paper is to describe a method for calculating resistance of cage rotor end-ring, based on 3-D finite element method using magnetic vector potential $\vec{A}$ and electric scalar potential ${\phi}$. The induced current of a cage rotor flows through the bars of a cage rotor. The current completes their closed paths by passing around the end-ring. The end-ring may contribute a significant influence to the performance of machine. The resistance under consideration of skin effect is calculate by using Joule's loss equation.

  • PDF

Analysis of Temperature Characteristic According to Variation of Air Duct of the Cast Resin Transformer (몰드변압기의 공기덕트의 구조 변화에 따른 온도특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.256-260
    • /
    • 2015
  • In this paper, achieved rise temperature distribution about degradation phenomenon of 24 MVA distribution cast resin transformer using CFD(Computational Fluid Dynamics). Usually, life of transformer is depended on temperature distribution of specification region than thermal special quality of transformer interior. Specially, life of transformer by decline of dielectric strength decreases rapidly in case rise by strangeness transformer interior hot spot temperature value permits. Because calculating high-voltage(HV) winding and low-voltage(LV) winding of cast resin transformer and Joule's loss of core for improvement these life, forecasted heat source, and HV winding and LV winding of cast transformer rise temperature distribution of core for supply of electric power and temperature distribution of highest point on the basis of the results. Also, calculated temperature rise limit of cast resin transformer and permission maximum temperature using analysis by electromagnetic heat source. Calculated and forecasted rise temperature distribution by heat source of thermal analysis with calculated result.

RECENT DEVELOPMENTS OF MEMBRANE TECHNOLOGY IN JAPAN

  • Kimura, Shoji
    • Membrane Journal
    • /
    • v.1 no.1
    • /
    • pp.5-12
    • /
    • 1991
  • Since the discovery of the Loeb-Sourirajan reverse osmosis membrane, thirty years have passed and many membrane technologies and new membranes for applications have been developed in the world. In the early stage of these developments Japan has not contributed much, but from the middle of 70ties Japan has started its own R&D projects starting from the desalination technology, and now various private industries and government ministries are actively engaging in R & D of membrane technologies in Japan. In Table 1 the chronological developments of important events of developments and projects relating membrane technologies inside and outside of Japan are introduced and their details will be explained. The first membrane technology applied in the Japanese industry was a electrodialysis(ED) process using ion-exchange membranes. These membranes were first developed in early 50ties and the Japanese government decided to use this method for concentration of sea-water to produce salt, which was then produced by solar evaporation. This development program started from 1960 by the Japan Monopoly Corp.(at that time). To apply ED process for sea-water concentration it was necessary to develop ion-exchange membranes having very low electric resistance to avoid energy loss due to Joule heat, and those having selectivity to permeate single valent ions only to avoid scale formation in the ED stacks. Three Japanese companies, Asahi Glass, Asahi Chemical and Tokuyama Soda, have succeeded to develop such membranes, and until 1971 all of the seven salt manufacturing companies had adopted ED for production of food salt.

  • PDF

Application Study of An On-site Hydrogen Production System for Power Generator Cooling (발전기 냉각용 On-Site 수소 생산 시스템 적용연구)

  • Moon, Jeon-Soo;Lee, Jae-Kun;Park, Pyl-Yang;Park, Kyoung-Il
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.5
    • /
    • pp.410-415
    • /
    • 2009
  • A hydrogen cooling method is used in a power generator for removing the unnecessary heat due to the windage loss of a rotor and the joule heat of a stator. A MEA (Membrane Electrolyte Assembly) hydrogen generator has been developed and applied as a hydrogen supplying system for the cooling of a 350MW power generator. As a field application result, the average potential of eleven cells and the voltage efficiency were measured 2.26V/cell and 65.4% (Higher Heating Value) respectively at the hydrogen pressure of 6 Bar, the hydrogen flow rate of 9.1L/min, and the current of 150A.

Deformation Technology for Thick Plate Using Single Pass Line Heating by High Frequency Induction Heating (고주파 유도 단일패스 선상가열 유기 후판 성형 기술)

  • Lee, K.S.;Eom, D.H.;Kim, C.W.;Pyun, S.Y.;Son, D.H.;Gong, G.Y.;Kim, B.M.;Lee, J.H.
    • Transactions of Materials Processing
    • /
    • v.20 no.6
    • /
    • pp.439-449
    • /
    • 2011
  • The temperature distribution and subsequent permanent deformation of SS400 carbon steel plate subjected to an induction-based line heating process were studied by a numerical method involving coupled 3-D electromagnetic-thermal-structural analysis. The numerical study revealed that the amount of permanent deformation is strongly related to the Joule loss caused by such process conditions as input power and moving speed of the heat source. To validate the numerical analysis results, line heating experiments were carried out with a high frequency(HF) induction heating(IH) equipment capable of bending thick plate with the moving accuracy of ${\pm}0.1mm$ in heating coil position. The amount of permanent deformation increased with decreasing moving speed and increasing input power.

Prediction of Temperature Rise in Power Appratus (초고압 전력기기의 온도상승 예측)

  • Kim, S.W.;Park, J.H.;Hahn, S.C.;Lee, B.Y.;Park, K.Y.;Song, W.P.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.113-115
    • /
    • 2001
  • In order to design the power appratus such ac bus bar, the current carrying ampacity should be determined, Since it is limited by maxium operating temperature, it is very important to predict temperature-rise on it. The main causes to raise temperature are joule's loss in the current carrying conductor and induced circulating and eddy current in the tank. The heat transfer is divided into convection and radiation on boundary, determining convection heat transfer coefficient is not easy. This paper propose a new technique that can be used to estimate the temperature rise in the extra high voltage bus bar. The heat transfer coefficient is analytically calculated by applying Nusselt Number depending on temperature as well as model geometry. The analytic method which use heat transfer coefficient is coupled with finite element method. The temperature distribution in the bus bar by the proposed method shows good agreement with experimental data.

  • PDF

Design of 1 MW High-temperature Superconducting Motor with Water-cooled Armature (수냉식 전기자로 구성된 1 MW 고온초전도 동기모터의 설계)

  • Baik, S.K.;Lee, J.D.;Kim, S.H.;Lee, E.Y.;Sohn, M.H.;Kwon, Y.K.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Lee, J.Y.;Hong, J.P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1258-1260
    • /
    • 2005
  • Superconducting synchronous motors and generators have the field coil composed of superconductor with almost zero resistance at superconducting state. Therefore, co or loss at the conventional field coil is eliminated and the superconducting machine gets higher efficiency. The armature coil of the superconducting machine is composed of cower wire and supported by non-magnetic material such as FRP(Fiber Reinforced Plastic). Although a fully-superconducting machine with superconducting armature coil has been researched, it was not developed toward industrial application because of AC transporting loss and difficulty in construction of the cooling structure and so on. This paper contains the design procedure of a 1 MW superconducting synchronous motor using high-temperature superconductor only for the field coil. Especially, the armature coil is designed by water-cooling in order to dissipate Joule heat easily. Moreover, 3-dimensional electromagnetic design is conducted to get a proper design result and reduce design errors from 2-dimensional approach.

  • PDF

Failure Mechanism Analysis of SAW Device under RF High Power Stress (RF 고전력 스트레스에 의한 SAW Device의 고장메카니즘 분석)

  • Kim, Young-Goo;Kim, Tae-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.215-221
    • /
    • 2014
  • In this paper, the improved power durability test system and method for an reliability analysis of SAW device is proposed and the failure mechanism through failure analysis is analyzed. As a result of the failure analysis using microscope, SEM and EDX, the failure mechanism of the SAW device is electromigration due to joule heating under high current density and high temperature condition. The electromigration makes voids and hillocks in the IDT electrode and the voids and hillocks can lead to short circuit and open circuit faults, respectively, increasing the insertion loss of an SAW filter. The accelerated life testing of the SAW filter for 450MHz CDMA application using the proposed power durability test system and method is carried out. $B_{10}$ lifetime of the SAW filter using Eyring model and Weibull distribution is estimated as about 98,500 hours.

Extreme Enhancements in GPS TEC on 8 and 10 November 2004

  • Chung, Jong-Kyun;Jee, Gun-Hwa;Kim, Eo-Jin;Kim, Yong-Ha;Cho, Jung-Ho
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.30.2-30.2
    • /
    • 2010
  • It is a mistaken impression that the midlatitude ionosphere was a very stable region with well-known morphology and physical mechanism. However, the large disturbances of midlatitude ionospheric contents in response to global thermospheric changes during geomagnetic storms are reported in recent studies using global GPS TEC map and space-born thermospheric UV images, and its importance get higher with the increasing application areas of space navigation systems and radio communication which are mostly used in the midlatitudes. Positive and negative storm phases are used to describe increase and decrease of ionospheric electron density. Negative storms result generally from the enhanced loss rate of electron density according to the neutral composition changes which are initiated by Joule heating in high-latitudes during geomagnetic storms. In contrast, positive ionospheric storms have not been well understood because of rare measurements to explain the mechanisms. The large enhancements of ground-based GPS TEC in Korea were observed on 8 and 10 November 2004. The positive ionospheric storm was continued except for dawn on 8 November, and its maximum value is ~65 TECU of ~3 times compared with the monthly mean TEC values. The other positive phase on 10 November begin to occur in day sector and lasted for more than 6 hours. The O/N2 ratios from GUVI/TIMED satellite show ~1.2 in northern hemisphere and ~0.3 in southern hemisphere of the northeast Asian sector on 8 and 10 November. We suggest the asymmetric features of O/N2 ratios in the Northeast Asian sector may play an important role in the measured GPS TEC enhancements in Korea because global thermospheric wind circulation can globally change the chemical composition during geomagnetic storms.

  • PDF

A Canine Model of Tracheal Stenosis Using Nd-YAG Laser (Nd-YAG laser를 이용한 기관협착 동물모델의 개발)

  • Kim, Jhin-Gook;Suh, Gee-Young;Chung, Man-Pyo;Kwon, O-Jung;Suh, Soo-Won;Kim, Ho-Joong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.1
    • /
    • pp.54-61
    • /
    • 2002
  • Background: Tracheal stenosis is an urgent but uncommon disease. Therefore, primary care clinicians have limited clinical experience. Animal models of a tracheal stenosis can be used conveniently for the learning, teaching, and developing new diagnostic and therapeutic modalities for tracheal stenosis. Recently, a canine model of a tracheal stenosis was developed using a Nd-YAG laser. To describe the methods and results of developed animal model, we performed this study. Methods : Six Mongrel dogs were generally anesthetized and the anterior 180 degree of tracheal cartilage of the animal was photo-coagulated using a Nd-YAG laser. The animals were bronchoscopically evaluated every week for 4 weeks and a pathologic evaluation was also made. Results : Two weeks after the laser coagulation, the trachea began to stenose and the stenosis progressed through 4 weeks. All animals suffered from shortness of breath, wheezing, and weight loss in the 3 weeks after the laser treatment, and two died of respiratory failure just before the fourth week. The gross pathologic findings showed the loss of cartilage and a dense fibrosis, which resulted in a fibrous stricture of the trachea. Microscopy also showed that the fibrous granulation tissue replaced destroyed cartilage. Conclusion : The canine model can assist in the understanding and development of new diagnostic and therapeutic modalities for tracheal stenosis.