• 제목/요약/키워드: Joule 열

Search Result 50, Processing Time 0.03 seconds

The acoustical effect due to the hole of pole piece for by dynamic speaker (다이내믹 스피커에서 폴피스 구멍에 의한 음향특성연구)

  • Oh, Sei-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.5
    • /
    • pp.317-322
    • /
    • 2018
  • It has been generally known that a hole presenting on the center of pole piece for the loudspeaker can be very helpful for the heat, which is radiated by Joule Effect at the voice coil, to emit to the outside of the magnetic gap. The existence of hole can also become a cause of the changes of the acoustical properties about the loudspeaker. The resonance frequency of loudspeaker increased with the increase of hole radius. However, increasing the hole length resulted in the decrease of the resonance frequency. These results are in an excellent agreement with the theoretical predictions for the equivalent mechanical circuit of Bass-Reflex cabinet system. The acoustical property of the loudspeaker with hole can be also predicted by the theoretical interpretation of Bass-Reflex cabinet system.

Measurement of Peltier Heat at the Solid/Liquid Interface and Its Application to Crystal Growth II : Measurement and Application (고/액 계면에서의 Peltier 열 측정 및 결정성장에의 응용 II : 측정과 응용)

  • Kim, Il-Ho;Jang, Kyung-Wook;Lee, Dong-Hi
    • Korean Journal of Materials Research
    • /
    • v.9 no.11
    • /
    • pp.1112-1116
    • /
    • 1999
  • Thermoelectric effects on the temperature changes at the solid- and liquid-phase and its interface were studied by using the unidirectional solidification of $\textrm{Bi}_{2}\textrm{Te}_{3}$. Cooling or heating effects measured with current density. polarity and current passing time were quite different. By separating sole Peltier, Thomson and Joule heat theoretically and experimentally, the Peltier coefficient at the solid/liquid interface of $\textrm{Bi}_{2}\textrm{Te}_{3}$ was -1.10$\times\textrm{10}^{-1}$V, and the Thomson coefficients of solid- and liquid-phase were 7.31\times\textrm{10}^{-4}V/K, 5.77\times\textrm{10}^{-5}V/K, respectively. When D.C. passed from solid-phase to liquid-phase during the crystal growth of $\textrm{Bi}_{2}\textrm{Te}_{3}$ the crystal with more directionality was obtained owing to increase of the temperature gradient in liquid by the Peltier cooling. But in reverse current direction, the crystallinity was not changed significantly.

  • PDF

An Electric Field and Thermal Analysis of 25.8kV class Plug-in Cable Connecting System (25.8kV급 플러그인 케이블접속시스템의 최적설계를 위한 전계해석 및 열해석)

  • Kim, Tae-Young;Kim, Han-Soo;Shin, Pan-Seok;Jang, Chang-Ho;Kim, Pyung-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.34-36
    • /
    • 2004
  • Cable 접속장치인 정격 25.8kV 600/1200A Plug-in socket의 절연설계, 전계분포해석 및 열계해석을 위하여 전자계 및 열해석 프로그램인 Flux2D를 이용하여 simulation하였다. Plug-in접속장치의 shield형상을 변화하면서 각종 금구류 및 접속장치의 절연물의 연면전계강도를 계산하여 기준전계와 비교 검토하여 전계해석 하였다. 해석결과 shield 의 위치와 형상의 변화에 따라 socket내부의 전계강도를 완화시키는 중요한 역할을 하고 있음을 보여주고 있다. 열해석은 도체저항의 Joule 열원으로 입력하였으며, 정상상태에서의 은도 분포는 설계에 영향을 주지 않는 것으로 분석되었다.

  • PDF

Thermodynamics of Mixtures (I). Ideal Gases (혼합물의 열역학 (제1보). 이상기체)

  • C. K. Yun
    • Journal of the Korean Chemical Society
    • /
    • v.17 no.5
    • /
    • pp.324-331
    • /
    • 1973
  • We study a mixture of ideal gases by use of recently developed methods in continuum thermodynamics of irreversible processes. A complete form of the free energy function and the gas law for each component are derived directly from an entropy production inequality by assuming that: (1) Constitutive functions depend on the mass densities, the diffusion velocities, the temperature and its gradient only. (2) Phenomenological coefficients appearing in an extra entropy flux are material constants. (3) The internal energy density per unit mass is independent of the total mass density (Joule).

  • PDF

Polymer형 내열성 PTC 소재의 특성 연구

  • 강영구;곽봉신
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1999.06a
    • /
    • pp.249-252
    • /
    • 1999
  • 전도성 충진제가 포함된 결정성 고분자내에 대전류가 흐르게 될 경우 Joule 효과로 소재자체의 발열현상이 발생하며 온도가 증가함에 따라 고분자의 용융점 부근에서 급격한 열팽창으로 인하여 고분자 내에 분포되어 있던 전도성 충진재 입자사이의 간격이 증가하게 되며 전자들의 흐름이 방해를 받게 된다. 이에 따라 전기저항이 커져 전류의 흐름이 감소되는 철상이 발생하며 이를 PTC(Positive Temperature Coefficient)라 하고 온도 증감에 따른 전도성 충진제 간의 electron tunnelling과 고분자의 결정변화에 의해 민감한 전기저항변화 특성을 나타낸다. (중략)

  • PDF

The Beat and Flow Analysis of the Liquid Helium for the Pressurization of Liquid Rocket Propellant Tank (액체로켓 추진제 탱크 가압용 액체헬륨의 열유동 해석)

  • 조기주;정영석;조인현;김용욱;이대성
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.1
    • /
    • pp.10-17
    • /
    • 2003
  • The steady and transient thermal and flow analysis for liquid helium using for the pressurization of liquid rocket propellant tanks have been conducted numerically. The required inner diameter of helium channel that satisfy the design mass flow rate and velocity, through the steady state analyses for various thermal conditions at the wall, is determined and it is found that due to the sign of Joule-Thomson coefficient of helium, the temperature of helium increase monotonically for adiabatic wall condition. The temporal behavior of helium temperature, density, velocity are also investigated under the existence of local heat inflow on the wall.

직류 전류 이용 종양세포의 효율적 치료에 관한 시뮬레이션 연구

  • Kim, Jae-Hong;Yang, Tae-Geon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.289-289
    • /
    • 2010
  • 정상 세포로부터 암과 같은 종양세포를 제거하는 방법으로 암세포가 사멸되는 임계온도 보다 높게 악성조직에 열을 가하는 방법이 연구되어지고 있다 [1]. 전류가 흐를 수 있는 4개의 전기탐침을 종양조직에 삽입하여 국부적으로 열을 발생시키는 발열요법으로 암을 치료하는 연구가 고려되고 있다. 발열요법은 1960년대에 시작하여 우리나라에서는 1985년 연세 암센터에서 capacitive type의 RF heating 또는 전자파에 의한 국소가온법과 방사선치료와 병용으로 이용되고 있다. 주로 이용되는 방법은 Radio frequency heating, Microwave heating, ultrasound heating을 들수 있다. 라디오주파수는 보통 300 MHz 이하의 주파수를 가리킨다. 본 연구에서는 교류파 대신에 직류전원에 의해 열을 발생하는 경우에 관한 연구이다. 전극에 의해 형성되는 전기장에 대한 방정식은 전도매질에서의 DC 응용모드이고, 조직 내에서의 직류 전류에 의해 발생되는 온도 분포를 모델링하는 bioheat 방정식과 연계된 문제이다. 전기장에 의해 발생되는 열의 근원은 resistive heat 또는 Joule 열이다. 본 연구에서는 교류 전류에 의한 RF heating 대신 단순한 모델의 경우로 직류 전류에 의한 열 발생에 관한 이론적 연구를 수행하였다. 종양 조직 내에 삽입된 전극에 22V를 인가하면 60초 이내에 $80^{\circ}C$까지 급속히 증가 된 후, 서서히 $90^{\circ}C$에 까지 도달한다. 4 개의 전극에 대칭적인 전위가 인가 된 경우 $50^{\circ}C$ 이상의 온도 분포를 암 조직의 모양과 유사하게 분포하게 하여 효과적인 치료를 수행 할 수 있는 조건을 제시한다.

  • PDF

Design and Construction of a High Temperature Creep Tester for Thin Film Specimens (박막시험편용 고온 크리프 시험기의 설계 및 제작)

  • Ko, Gyoung-Dek;Lee, Sang-Shin;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.253-259
    • /
    • 2007
  • A new material tester has been developed to measure mechanical properties of thin film specimens at high temperature. It is useful for observing oxide film growth or local deformation on the surface, and for measuring creep strength. Main characteristics of the tester is as follows; First, high temperature is achieved by Joule heating generated by electricity passing through the specimen, which does not need to enclose the specimen by a furnace or a heating chamber. The exposed specimen enables one to observe the surface during the test. Because the overall size of the test rig is compact, the whole test rig can be placed in a chamber for environmental controlled tests. The loading device is from a level scales. Not only static load with fixed counter weight, but also variable load by moving counter weight controlled remotely can be applied for an ordinary creep test and creep-fatigue test, respectively. The detail of the construction, operation principle, and the specification are described. And also, an example of test result obtained using the creep tester is presented.

Structural Design and Thermal Analysis of a Module Coil for a 750 kW-Class High Temperature Superconducting Generator for Wind Turbine (풍력 터빈용 750 kW 급 고온초전도 발전기 모듈의 코일 구조 설계 및 열 해석)

  • Tuvdensuren, Oyunjargal;Go, Byeong-Soo;Sung, Hae-Jin;Park, Min-Won
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.2
    • /
    • pp.33-40
    • /
    • 2019
  • Many companies have tried to develop wind power generators with a larger capacity, smaller size and lighter weight. High temperature superconducting (HTS) generators are more suitable for wind power systems because they can reduce volume and weight compared with conventional generators. However, the HTS generator has problems such as huge vacuum vessel and the difficulty of repairing the HTS field coils. These problems can be overcome through the modularization of the HTS field coil. The HTS module coil require a current leads (CLs) for deliver DC current, which causes a large heat transfer load. Therefore, CLs should be designed optimally for reducing the conduction and Joule heat loads. This paper deals with a structural design and thermal analysis of a module coil for a 750 kW-class HTS generator. The conduction and radiation heat loads of the module coils were analysed using a 3D finite element method program. As a result, the total thermal load was less than the cooling capacity of the cryo-cooler. The design results can be effectively utilized to develop a superconducting generator for wind power generation systems.