• 제목/요약/키워드: Josephson junctions

검색결과 112건 처리시간 0.02초

YBaCuO계 초전도소결체 자기소자 (Preparation of Magnetic Field Sensor with YBaCuO Superconducting Ceramics)

  • 이상헌
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.109-111
    • /
    • 2000
  • A magnetic field sensor is fabricated with superconducting ceramics of Y-Ba-Cu-O system. The prepared material shows the superconductivity at about 95K. The sensor at liquid nitrogen temperature shows the increase in electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor is changed from zero to a value more than 100$\mu$V by the applied magnetic field. The change in electrical resistance depends on magnetic field. The sensitivity of this sensor is 2.9 ohm/T. The sensing limit is about $1.5\times$$10^{-5}$ (=1.5$\times$$10^{-1}$ G). The increase in electrical resistance by the magnetic field is ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material.

  • PDF

산화물 초전도체의 자기적 특성 (Magnetic Properties of Oxide Superconducting Material)

  • 이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.115-118
    • /
    • 2003
  • The sensor at liquid nitrogen temperature showed the increase of electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor was changed from zero to a value more than $100\;{\mu}V$ by the applied magnetic field. The change of electrical resistance depended on magnetic field. The sensitivity of this sensor was $2.9\;{\Omega}/T$. The sensing limit was about $1.5{\times}10^{-5}\;T$. The increase of electrical resistance by the magnetic field was ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material. Considering the observed properties of the superconductor with trapped magnetic flux, a magnetic sensor was fabricated to detect simultaneously both the intensity and the direction of the magnetic field.

  • PDF

Operation of a High-T$_c$ Rapid Single-Flux-Quantum 4-stage Shift Register

  • Park, J.H.;Kim, Y.H.;Kang, J.H.;Hahn, T.S.;Kim, C.H.;Lee, J.M.
    • Progress in Superconductivity
    • /
    • 제1권2호
    • /
    • pp.105-109
    • /
    • 2000
  • We have designed and fabricated a single-flux-quantum(SFQ) four-stage shift register using YBCO bicrystal Josephson junctions, and tested its operations using a digital measurement set-up. The circuit consists of 4 shift register stages and a read SQUID placed next to each side of the shift register. Each SQUID was inductively coupled to the nearby shift register stage. The major obstacle in testing the circuits was the interference between the two read SQUIDs, and we could get over the problem by determining the correct operation points of the SQUID from the simultaneously measured modulation curves. Loaded data ('1' or '0') were successfully shifted from a stage to the next by a controlled current pulse injected to the bias lines located between the stages, and the corresponding correct data shifts were observed with the two read SQUIDs.

  • PDF

Magnetic Sensor by Using Magnetic Effect in YBaCuO Superconductor

  • 이상헌;김찬중
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.69-71
    • /
    • 2003
  • The magnetic field sensor was fabricated with superconducting ceramics of YBaCuO system. The sensor at liquid nitrogen temperature showed the increase of electrical resistance by applying magnetic field. Actually the voltage drop across the sensor was changed from zero to a value more than 100 $mutextrm{V}$ by the applied magnetic field. The change in electrical resistance depended on magnetic field. The sensitivity of this sensor was 2.9 $\Omega$/T. The sensing limit was about $1.5\times$10$^{-5}$. The increase of electrical resistance by the magnetic field was ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material. Considering the observed properties of the superconductor with trapped magnetic flux, a magnetic sensor was fabricated to detect simultaneously both the intensity and the direction of the magnetic field.

  • PDF

SELF-FIELD EFFECT ON CRITICAL CURRENT OF LARGE JOSEPHSON JUNCTIONS

  • Kim, K.T.;Lee, S.H.;Lee, K. W.
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2002년도 동계연구발표회 논문개요집
    • /
    • pp.142-143
    • /
    • 2002
  • 최근 RSFQ (Rapid Single Flux Quantum) 기술은 초고속, 극저전력의 초전도 디지털 전자회로의 구현 가능성으로 인해 많은 관심을 모으고 있다.[1] 특히 정밀측정 및 표준 분야에 있어서, 기존의 직류 전압표준 소자에 비해 작동이 간편하며, 다양한 측정기술에 활용할 수 있는 차세대 조셉슨 전압표준용 소자에 응용가능성이 주목받고 있다. 그러나 RSFQ의 이러한 강점들이 제대로 발휘되려면 1 ㎄/$\textrm{cm}^2$ 수준의 고임계전류, 10 $\mu\textrm{m}$ 이하의 미소 조셉슨 접합을 신뢰성 있고 재현성 있게 제작할 수 있어야한다. (중략)

  • PDF

BiPbSrCaCuO 초전도 자기검출소자 (Magnetic Field Sensor using BiPbSrCaCuO Superconductor)

  • 이상헌;이성갑;이영희
    • 한국전기전자재료학회논문지
    • /
    • 제16권5호
    • /
    • pp.429-434
    • /
    • 2003
  • The magnetic field sensor was fabricated with superconducting ceramics of BiPbSrCaCuO system. The sensor at liquid nitrogen temperature showed the increase of electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor was changed from zero to a value more than 100 $\mu\textrm{V}$ by the applied magnetic field. The change of electrical resistance depended on magnetic field. The sensitivity of this sensor was 2.9 $\Omega$/T. The sensing limit was about 1.5${\times}$10$\^$-5/ T. The increase of electrical resistance by the magnetic field was ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material. Considering the observed properties of the superconductor with trapped magnetic flux, a magnetic sensor was fabricated to detect simultaneously both the intensity and the direction of the magnetic field.

세라믹 자성 센서 제조기술에 관한 연구 (Study on the Ceramics Magnetic Sensor Fabrication Technology)

  • 이상헌;이성갑
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.61-65
    • /
    • 2003
  • A magnetic field sensor is fabricated with superconducting ceramics system The prepared material shows the superconductivity at about 95K. The sensor at liquid nitrogen temperature shows the increase in electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor is changed from zero to a value more than $100{\mu}V$ by the applied magnetic field. The change in electrical resistance depends on magnetic field. The sensitivity of this sensor is 2.9 ohm/T. The increase in electrical resistance by the magnetic field is ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material.

  • PDF

고온 초전도 $\textrm{YBa}_{2}\textrm{Cu}_{3}\textrm{O}_{7-x}$ 계단형 모서리 접합의 이중접합 특성 (Characteristics of Double-junction of High-$\textrm{T}_{c}$ Superconducting $\textrm{YBa}_{2}\textrm{Cu}_{3}\textrm{O}_{7-x}$ Step-edge Junctions)

  • 황준식;성건용;강광용;윤순길;이광렬
    • 한국재료학회지
    • /
    • 제9권1호
    • /
    • pp.86-91
    • /
    • 1999
  • (001) $\textrm{SrTiO}_3$(STO) 기판위에 고온초전도 $\textrm{YBa}_{2}\textrm{Cu}_{3}\textrm{O}_{7-x}$(YBCO)박막을 이용한 계단형 모서리 임계접합을 제조하였다. STO (100) 단결정 기판위에 계단형 모서리(step-edge)를 제작하기 위한 이온밀링 마스크로 plasma enhanced chemical vapor deposition방법으로 증착된 diamond-like carbon (DLC) 박막을 사용하였고, oxygen reactive ion etch 방법으로 건식식각하였다. 이렇게 제작된 계단형 모서리 기판위에 c-축 수직한 YBCO 박막과 STO박막을 pulsed laser deposition방법으로 에피텍셜하게 증착하였다. 계단의 상층과 하층에서 모두 임계가 형성되었으며 이 접합의 임계온도는 77 K 이상이었고 16K에서 $\textrm{I}_{c}\textrm{R}_{n}$products가 7.5mV, 77 K에서 0.3mV의 값을 나타내었다. 이들 전류-전압 특성은 two noisy resistively shunted Josephson junction 모델을 잘 만족하였다.

  • PDF

저잡음 심자도측정시스템 개발을 위한 고온초전도 SQUID 센서의 제작 (Fabrication of HTS SQUID Sensors for the Application to a High S/N Ratio Magnetocardiograph System)

  • 김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • 제6권1호
    • /
    • pp.19-23
    • /
    • 2004
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal Josephson junctions on 10 mm ${\times}$ 10 mm $SrTiO_3$ substrates have been fabricated. The pickup coil of the device was designed to have 16 parallel loops with 50-fm-wide lines. We could obtain optimised direct coupled YBCO SQUID magnetometer design with field sensitivity $B_{N}$ $\Phi$/ of $4.5 nT/\Phi_{0}$ and magnetic field noise $B_{N}$ of about $22 fT/Hz^{1}$2/ with an I/f corner frequency of 2 Hz measured inside a magnetically shielded room. Preliminary results of magnetocardiograph measurement using the HTS SQUID magnetometers show signal to noise ratio of about 110, which is comparable to the quality of a commercial MCG system based on Nb-SQUIDs.

  • PDF

$28 A/cm^2~ 940 A/cm^2$의 임계전류밀도 범위로 제작된 $Nb/Al-AlO_x/Nb$ 터널접합의 전기적 특성 (Electrical Characteristics of $Nb/Al-AlO_x/Nb$ Tunnel Junction fabricated with $I_c$ Values in the Range of $28 A/cm^2~ 940 A/cm^2$)

  • 홍현권;김규태;박세일;김구현;남두우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.4-7
    • /
    • 2002
  • Samples of $Nb/Al-AlO_x/Nb$ tunnel junction with the size of $50 ${\mu}{\textrm}{m}$ {\times} 50 ${\mu}{\textrm}{m}$$ were fabricated by using self-aligning and reactive ion etching technique In the high quality samples, the $V_m$ value (the product of the critical current and subgap resistance measured at 2 mV) was 34 mV at the critical current density of $J_c: 500 A/cm^2 and the V_g$ value (the gap voltage) was 2.8 mV. For the higher $J_c$ sample, voltage fluctuation at the gap voltage was observed. The $V_m and J_c$ values for this sample were 8 mV and 900 A/cm$^2$, respectively. Also, the relationship between critical current density $J_c$ and specific normal conductance $G_s$ of the junctions with $J_c$ in the range of 28 A/cm$^2$~940 A/cm$^2$was investigated.