• Title/Summary/Keyword: Joint range of motion

Search Result 881, Processing Time 0.03 seconds

Effect of gender difference and change of load on lower extremity kinetics in step descent (계단 하강 시 성별차이와 중량 변화가 하지역학에 미치는 영향)

  • Seunghyun, Hyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.1
    • /
    • pp.109-116
    • /
    • 2023
  • The purpose of this study was to investigate the influence of gender and load carriage difference on the lower extremity kinetics during stair descent. Ten healthy males and 10 healthy females were recruited (n=20). In the Maximum resultant velocity, it showed more velocity was decreased with difference by the change of gender (males>females) and load carriage (30%, 20%, 10%> 10%). And, resultant velocity showed interaction between gender and a load (load>gender). Main effect by gender during stair descent showed leg length was decreased in females than that of males at initial contact phase. Also, main effect by gender during stair descent showed more hip, knee flexed and plantar flexion of ankle joint in females than that of males. In the kinetics variables, main effect by gender during stair descent showed more higher reaction force of medial-lateral direction, and leg stiffness in males than that of females. We found that females successfully accommodated a load during stair descent by decreasing the range of motion of the hip joint angle and resultant velocity of movement. Males, on the other hand, require greater medial-lateral, vertical reaction force, and leg stiffness to accommodate a load, and control of momentum.

Percutaneous Radiofrequency ablation for the Treatment of Osteoid osteoma (유골골종의 경피적 고주파 열 치료)

  • Seo, Jai-Gon;Jung, Kwang-Hoon;Yang, Il-Soon
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.8 no.3
    • /
    • pp.83-89
    • /
    • 2002
  • Purpose: To analyze the postoperative functional and radiographic follow-up results in patients who underwent percutaneous radiofrequency ablation therapy after the diagnosis of osteoid osteoma. Materials and Methods: Seven patients, who were clinically and radiographically diagnosed with osteoid osteoma from July 1999 to January 2001, and received percutaneous radiofrequency ablation therapy. The average follow-up period was 15.5 months(range, 8~25 months). For the diagnosis and accurate localization of the lesion, simple radiography, computed tomography and magnetic resonance imaging(MRI) were performed preoperatively. Simple radiographs and MRI were taken periodically for the follow-up studies. Results: In all 7 patients, symptoms completely disappeared within 3 days after the operation. The average period of hospitalization was 2.4 days, excluding 1 patient who needed an additional burn treatment. The average postoperative night and day pain scores were 1.8 and 1.3, respectively. The average vocational and recreational activity scores were 1 and 0.6, respectively. Conclusions: Satisfactory functional results were obtained with percutaneous radiofrequency ablation therapy for the elimination of osteoid osteoma. Compared to conventional treatment, the advantages of this therapy were short hospitalization period, no internal fixation and bone graft for preventing fracture, and no limitation of joint motion by long fixation period.

  • PDF

Acutrak Screw Fixation for Radial Head Fracture -7 Cases Report- (Acutrak 나사를 이용한 요골두 골절의 치료 -7례 보고-)

  • Kim, Kwang-Yul;Lim, Moon-Sup;Shin, Heung-Sub;Choi, Shin-Kwon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.75-80
    • /
    • 2006
  • Purpose: To evaluate the efficiency of Acutrak screw fixation for radial head fracture (Mason type 2) without considering the safe Bone of radial head. Materials and Methods: Consecutive seven radial head fracture of Mason type II underwent internal fixation with Acutrak screws from May 2001 to February 2003. The mean follow-up period was 1.2years (ranged, $6 months{\sim}2.5 years$). The mean age of patients was 47 years old (ranged, $36{\sim}60years$ old). The cause of injury were fall down -4 cases and traffic accident -3 cases. The results were evaluated by Mayo Clinic results scoring system. Results: Functional Rating Index of Mayo Clinic was excellent- 2 cases and good- 5 cases. There were no nonunion, loosening, heterotopic ossification, infection or degenerative changes. The postoperative range of motion in elbow joint is nearly full for flexion, extension, pronation and supination in this study Conclusion: Consideration of safe zone is not necessary when Acutrak screws are used for radial head fracture. It seems to be a useful method that Acutrak screw fixation for radial head fracture (Mason type II) could achieve good radiologic and clinical results without influencing proximal radio-ulnar joint and has powerful fixation.

  • PDF

Influence on Intra-limb Coordination in Individuals Wearing a Knee Extension Constraint Brace during Walking (무릎 신전 제한형 보조기 착용이 보행 시 하지 내 협응에 미치는 영향)

  • Chang, Yoonhee;Jeong, Bora;Kang, Sungjae;Ryu, Jeicheong;Kim, Gyu Seok;Mun, Museong;Ko, Chang-Yong
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.207-214
    • /
    • 2016
  • The aim of this study was to evaluate Influence on intra-limb coordination in individuals wearing knee brace during walking. Seven healthy male adults ($32.3{\pm}2.7$ years old, $175.2{\pm}3.8cm$, $76.2{\pm}8.7kg$) participated. They wore knee brace or didn't wear any knee brace and were asked to walk along a 10 m long walkway. Spatiotemporal parameters, angles of the lower limbs, and intra-limb continuous relative phase (CRP) were measured and calculated. No differences of spatiotemporal parameters were shown (all p > 0.05). There were no changes in the angle and its range of motion (ROM) in the hip for the subjects as wearing knee brace, while ROM ($65.5{\pm}3.7^{\circ}$ vs. $60.5{\pm}3.5^{\circ}$, p < 0.05) of the angle and maximum flexion angles (stance: $31.9{\pm}4.6$ vs. $25.6{\pm}5.5$, swing: $76.7{\pm}3.1$ vs. $68.9{\pm}3.4$, all p < 0.05) in the knee significantly decreased. No changes in ROM of angle in the ankle were shown, whereas maximum dorsiflexion decreased ($22.4{\pm}2.6$ vs. $19.2{\pm}2.1$, p < 0.05) and maximum plantarflexion increased ($9.5{\pm}3.0$ vs. $15.7{\pm}2.2$, p<0.05). There were no changes in most of CRP between joints. CRP between the hip and knee joints decreased ($93.0{\pm}7.8$ vs, $84.7{\pm}4.9$, p < 0.05). Most of CRP standard deviation increased (between the hip and ankle joint during swing: $25.1{\pm}6.7$ vs. $32.4{\pm}1.9$, between the knee and ankle joint during stance: $46.0{\pm}12.9$ vs. $80.1{\pm}31.1$, between the knee and ankle joint during swing: $34.5{\pm}4.1$ vs. $37.6{\pm}3.1$, all p < 0.05). These results indicated that wearing knee brace affected joint angle and intra-limb coordination, but less affected gait features.

Comparative evaluation of the safety and efficacy of recombinant FVIII in severe hemophilia A patients

  • Abolghasemi, Hassan;Panahi, Yunes;Ahmadinejad, Minoo.;Toogeh, Gholamreza;Karimi, Mehran;Eghbali, Aziz;Mirbehbahani, Nargess Bigom;Dehdezi, Bighan Keikhaei;Badiee, Zahra;Hoorfar, Hamid;Eshghi, Peyman;Maghsoudi, Nader;Sahebkar, Amirhossein;Gholami-Fesharaki, Mohammad
    • Journal of Pharmacopuncture
    • /
    • v.21 no.2
    • /
    • pp.76-81
    • /
    • 2018
  • Objective: This study compared the safety and efficacy of $Safacto^{(R)}$ versus $xyntha^{(R)}$ in patients with severe hemophilia A. Methods: Thirty-three male patients with severe hemophilia A were randomly divided into two groups. Seventeen patients received $Safacto^{(R)}$ and 16 patients received $Xyntha^{(R)}$ for four consecutive times. The dosage of FVIII was 40-50 IU/kg for each injection. Plasma level of FVIII activity was evaluated before every injection, 15 minutes after the injection and one month after the start of the trial. The rate of factor VIII activity, pain and joint motion were also assessed before and after the treatment. Results: Plasma level of FVIII clotting activity in $Safacto^{(R)}$ and $Xyntha^{(R)}$ were $1.96{\pm}0.5IU/dl$ and $1.63{\pm}0.5IU/dl$ and increased to $88.84{\pm}25.2IU/dl$ and $100.09{\pm}17.8IU/dl$, respectively (P<0.001). Pain score and range of motion improvement were $9.3{\pm}0.9$ and $8.7{\pm}0.1$ in $Safacto^{(R)}$ (P=0.17); and $9.4{\pm}0.8$ and $8.8{\pm}0.3$ in $Xyntha^{(R)}$ (P=0.35), respectively. No allergic or other unfavorable reactions was observed with either of the preparations. Conclusion: This study showed that $Safacto^{(R)}$ has a favorable efficacy and safety profile.

Kinematic and Ground Reaction Force Analyses of the Forehand Counter Drive in Table Tennis (탁구 포핸드 카운터 드라이브 동작의 운동학적 변인 및 지면 반력 분석)

  • Lee, Young-Sik;Lee, Chong-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.2
    • /
    • pp.155-165
    • /
    • 2010
  • The purpose of this study was to analyze kinematic quantitative factors required of a forehand counter drive in table tennis through 3-D analysis. Four national table tennis players participated in this study. The mean of elapsed time for total drive motion was $1.009{\pm}0.23\;s$. At the phase of impact B1 was the fastest as 0.075 s. This may affect efficiency in the initial velocity and spin of the ball by making a powerful counter drive. The pattern of center of mass showed that it moved back and returned to where it was then moved forward. At the back swing, lower stance made wide base of support and a stronger and safer stance. It may help increasing the ball spin. Angle of the elbow was extended up to $110.75{\pm}1.25^{\circ}$ at the back swing and the angle decreased by $93.75{\pm}3.51^{\circ}$ at impact. Decreased rotation range of swinging arm increased linear velocity of racket-head and impulse on the ball. Eventually it led more spin to the ball and maximized the ball speed. Angle of knee joint decreased from ready position to back swing, then increased from the moment of the impact and decreased at the follow thorough. The velocity of racket-head was the fastest at impact of phase 2. Horizontal velocity was $7796.5{\pm}362\;mm/s$ and vertical velocity was $4589.4{\pm}298.4\;mm/s$ at the moment. It may help increase the speed and spin of the ball in a moment. The means of each ground reaction force result showed maximum at the back swing(E2) except A2. Vertical ground reaction force means suggest that all males and females showed maximum vertical power(E2), The maximum power of means was $499.7{\pm}38.8\;N$ for male players and $519.5{\pm}136.7\;N$ for female players.

Clinical Features of Distal Tibial Fractures and Treatment Results of Minimally Invasive Plate Osteosynthesis (원위 경골 골절의 임상양상 및 최소 침습적 금속판 고정술의 결과)

  • Kim, Weon-Yoo;Ji, Jong-Hun;Kwon, Oh-Soo;Park, Sang-Eun;Kim, Young-Yul;Kil, Ho-Jin;Jeong, Jae-Jung
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.2
    • /
    • pp.94-100
    • /
    • 2012
  • Purpose: The purpose of this study is to analyze the clinical features of distal tibia fractures and to evaluate the treatment outcomes of minimally invasive plate osteosynthesis (MIPO). Materials and Methods: From January 2004 to December 2009, 84 cases of 81 patients treated with plate fixation for distal tibia fracture were enrolled in this retrospective review. We investigated age, sex, injury mechanism, fracture patterns, and complications, and the clinical features were analyzed. To evaluate the treatment outcomes of MIPO, we divided into two groups. MIPO group consisted of 55 patients were treated with MIPO technique and conventional group consisted of 18 patients were treated with open reduction and internal fixation with conventional anterolateral plating. The results were compared between two groups by assessing bony union time, operation time, amount of blood loss, range of ankle motion, clinical score by American Orthopaedic Foot and Ankle Society (AOFAS) score, and post-operative complications. Results: The mean age of 81 patients with distal tibia fracture was 54.8 years. According to AO classification, A1:2:3 were 16, 20, 16 patients, B1:2:3 were 2, 8, 7, C1:2:3 were 1, 3, 11 patients. According to injury mechanism, slip down injury was patients, traffic accident was 26, fall from height injury was 14 patients respectively. The type A fractures were lower energy trauma and more older patients. The type C fractures were higher energy trauma and younger patients. MIPO group was better than conventional group in operative time, blood loss, bony union time, and ankle joint motion. In complications, MIPO group showed no nonunion and infection, one malunion, one skin necrosis, nine skin irritations, and one screw breakage. Conventional group showed two nonunion, four infections, two skin necrosis, and one metal failure. Conclusion: Distal tibial fractures caused by low energy trauma were on the increase. Minimal invasive plate osteosynthesis was shorter bony union time and operation time, less blood loss, and larger ankle motions than conventional open reduction and plate fixation.

Operative Treatment of Terrible Triad in Elbow of Adults (성인 주관절의 요골두와 구상돌기 골절을 동반한 탈구의 수술 적 치료 (성인 주관절에 발생한 위험3증주의 수술적 치료))

  • Kim, Byung-Heum;Park, Jong-Seok;Choi, Ho-Rim;Lee, Sang-Sun;Rah, Soo-Kyun;Lee, Hyun-Wook
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.1
    • /
    • pp.50-59
    • /
    • 2006
  • Purpose: The nonoperative outcome of elbow dislocations with associated radial head and coronoid fractures are often unsatisfactory because of chronic instability and stiffness from proloned immobilization, Therefore we managed these injuries with well programed surgical appproaches. Method: Ten patients with this injury were evaluated retrospectively from May 1998 to June 2004 after a minimum of 12 months. These injuries include elbow dislocation and associated fractures of both the radial head and the coronoid process. All ten patients were treated by one clinic operatively with similar scheduled surgical methods which started on the lateral side and terminated on the medial side of the elbow. Radial head and neck fractures were classified Mason types, as two and three types respectively with six and four cases and six cases were fixated. Coronoid process were fixated with screws anteroposterior directly or anchor suture in all cases, each type was classified one, two and three. where were three type one, four type two, and three type three were according to Regan and Morrey classification. Results: The outcome was three resulting in excellent, four good, two normaland and the remaining case was one poor according to the Mayo Elbow Performance score. At a terminal follow up, the range of motion of the elbow averaged flection contracture, $6^{\circ}(0{\sim}20^{\circ})$ and further flection, $129^{\circ}(115{\sim}140^{\circ})$. Two patients had complications requiring additional care. One, displaced coronoid process which was repaired with capsule and the other patient experienced, palsy of ulnar nerve and contracted elbow joint. Conclusions: Usage of early operation as the minimum injury of medial ligaments complex and the rigid fixation of fractures to prompt motion with our scheduled management for elbow dislocations with associated radial head and coracoid fractures provided excellent results.

Estimation of Human Lower-Extremity Muscle Force Under Uncertainty While Rising from a Chair (의자에서 일어서는 동작 시 불확실성을 고려한 인체 하지부 근력 해석)

  • Jo, Young Nam;Kang, Moon Jeong;Chae, Je Wook;Yoo, Hong Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.10
    • /
    • pp.1147-1155
    • /
    • 2014
  • Biomechanical models are often used to predict muscle and joint forces in the human body. For estimation of muscle forces, the body and muscle properties have to be known. However, these properties are difficult to measure and differ from person to person. Therefore, it is necessary to predict the change in muscle forces depending on the body and muscle properties. The objective of the present study is to develop a numerical procedure for estimating the muscle forces in the human lower extremity under uncertainty of body and muscle properties during rising motion from a seated position. The human lower extremity is idealized as a multibody system in which eight Hill-type muscle force models are employed. Each model has four degrees of freedom and is constrained in the sagittal plane. The eight muscle forces are determined by minimizing the metabolic energy consumption during the rising motion. Uncertainty analysis is performed using a first-order reliability method. The one-standard-deviation range of agonistic muscle forces is calculated to be about 150-300 N.

Shoulder Arthrodesis in Brachial Plexus Injury Patient (상완신경총 손상 환자에서 시행한 견관절고정술)

  • Han, Chung-Soo;Chung, Duke-Whan;Lee, Jae-Hoon;Jeong, Bi-O;Park, Hyun-Chul;Kim, Jin-Young;Song, Jong-Hoon;Seo, Jae-Wan
    • Archives of Reconstructive Microsurgery
    • /
    • v.18 no.2
    • /
    • pp.55-61
    • /
    • 2009
  • Purpose: To analyze the clinical and radiologic results of the shoulder arthrodesis in brachial plexus injury patients with flail upper extremity. Material and Method: From Aug 1978 to April 2008, 29 shoulders in 29 patients with brachial plexus injury with shoulder fusion, we evaluated 20 shoulders in 20 patients, more than 1 year follow up. The average follow-up period was 6.45years (range: 1year~24years). There were 13 men and 7 women, and the mean age at the time of trauma was 32.0years(2~65 years). The type of injury was a motorcycle accident in 11 patients, in car accident in 5, pedestrian accident in 3, and fall from a height in 1. The lesion of injury was root and trunk in 1 patient, trunk and cord in 1, trunk in 18. Surgery was performed on the whole arm type paralysis in 12 patients, lower arm type paralysis in 8 patients. The preoperative visual analog scale score was 8.7(7~10). When the trapezius and serratus anterior muscle were in function, operation was performed. 18 patients were processed to the additional operation. Gracilis free flap in 6 patients, neurotization in 3, Steindler flexor plasty in 6, and tendon transfer in 3 were performed. Fixation was conducted with cancellous screws in 13 patients, Knoles pins in 5, and cancellous screws and Knoles pins in 2. The position of the arthrodesis at operation was $28.5^{\circ}$($20~45^{\circ}$) in abduction, $30.3^{\circ}$($20~45^{\circ}$) in flexion, and $30.8^{\circ}$($20~40^{\circ}$) in internal rotation. Result: The follow up visual analog scale score was 3.4(0~7). Postoperatively, shoulder spica cast was applied for 15.3weeks(8-20weeks). The median time to bony union was 17.7weeks(9~28weeks). Average range of motion was $32.0^{\circ}$($15~40^{\circ}$) of abduction, $24.0^{\circ}$($10~40^{\circ}$) of flexion, and $18.5^{\circ}$($10~30^{\circ}$)of internal rotation. Conclusion: The shoulder fusion in brachial plexus injury patients is one of the good methods to relieve pain, improve the function and stabilize the flail shoulder joint.

  • PDF