• Title/Summary/Keyword: Joint condition

Search Result 1,241, Processing Time 0.029 seconds

A Counterplan of temperature crack control by a heat of hydration of Subway concrete box structure concerned External Temperature (대기온도를 고려한 지하철 콘크리트 Box 구조물의 수화열에 의한 온도균열제어 대책)

  • Roh, Hyun-Sup;Kim, Eun-Kyum;Yang, Sin-Chu
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.581-584
    • /
    • 2007
  • The subway concrete box structure can`t establish expansion joint because of animal power delivery of the subway rail. In this case, As increase of structure volume, it is subjected to cause temperature crack. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box structure, examined a condition of temperature crack occurrence by a heat of hydration concerned external temperature from analysing by a three dimensional finite element method.

  • PDF

ADVANCED DOMAIN DECOMPOSITION METHOD BY LOCAL AND MIXED LAGRANGE MULTIPLIERS

  • Kwak, Junyoung;Chun, Taeyoung;Cho, Haeseong;Shin, Sangjoon;Bauchau, Olivier A.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.18 no.1
    • /
    • pp.17-26
    • /
    • 2014
  • This paper presents development of an improved domain decomposition method for large scale structural problem that aims to provide high computational efficiency. In the previous researches, we developed the domain decomposition algorithm based on augmented Lagrangian formulation and proved numerical efficiency under both serial and parallel computing environment. In this paper, new computational analysis by the proposed domain decomposition method is performed. For this purpose, reduction in computational time achieved by the proposed algorithm is compared with that obtained by the dual-primal FETI method under serial computing condition. It is found that the proposed methods significantly accelerate the computational speed for a linear structural problem.

Evaluation of Reliability for Welded thick steel joint (후판 강용접부의 신뢰성 평가)

  • 최원두;이영호;길두송;박상기
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.327-329
    • /
    • 2004
  • Reliability evaluation of the welded structure for industrial structures/facilities such as power plant and petro-chemical refinery facilities is very important, and especially the reliability diagnosis of the structure is based on the exact evaluation of materials properties. But, the conventional Pre-Qualification test had the difficulty of evaluating the real material properties in the field because the test was made on the specimen with the simulated welding for the in-field welding condition. Therefore, a continuous indentation technique was proposed for simple and non-destructive testing of in-field structures and for selective testing of local range such as heat affected zone and weldment.

  • PDF

A Study on Fatigue Strength Characteristics of Weld Joint using Metal Type Flux Cored Wire (금속계 플럭스들이 용접이음부의 피로강도 특성에 관한 연구)

  • 강성원;신동진;김환식
    • Journal of Welding and Joining
    • /
    • v.12 no.4
    • /
    • pp.151-161
    • /
    • 1994
  • FCAW has wide application in ship fabrication, maintenance and field erection. It has many advantages over SMAW.SAW and GMAW process. In many applications, the FCAW provides highquality weld metal. This method can reduce weld defects especially porosity and spatter. But the fatigue characteristics of those deposited metal have been rarely investigated. The purpose of this study is to investigate the cyclic stress-strain behavior and fatigue tests by the constant strain control were carried out on the rounded smooth specimen with deposited metal using the metal type flux cored wire. As the results of this study for the deposited metal welded by the metal type flux cored wire, the hardening or softening characteristics under cyclic load were investigated and cyclic stress-strain curve, strain-fatigue life curve, stress-strain function and fatigue life relation which are useful to estimate the fatigue life under the stress concentration condition were obtained.

  • PDF

A Study on Mechanical Properties for Pb-free Solders of Electronic Packages (전자부품의 Pb-free 솔더에 대한 기계적 특성에 관한 연구)

  • 허우진;백승세;정영훈;권일현;양성모;유효선
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.83-85
    • /
    • 2003
  • This paper is investigated the shear strength by using the micro shear-punch test method for Sn-37Pb alloy, binary and ternary alloys of environment-friendly Pb-free solder alloys which would be surely applicable to the electronic packages. As a result, in case of Max. shear strength, Sn-4Ag-0.5Cu has the highest value and Sn-37Pb has the lowest value on every condition of experiment temperature. Also, In case of Pb-free solder joint specimens, it was found that Pb-free solder alloys have higher value of shear strength than eutectic Sn-Pb solder alloy and Sn-4Ag-0.5Cu has the highest value.

  • PDF

Giant Cell Tumor in Talar Body - A Case Report - (거골 체부에 생긴 거대세포종 - 증례보고 -)

  • Suh, Jeung-Tak;Jung, Ju-Young;Yoo, Chong-Il
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.5 no.4
    • /
    • pp.229-234
    • /
    • 1999
  • Giant cell tumor of the talus is an extremely rare condition and therapeutic options are ill defined. Recently we experienced a case of giant cell tumor of the talar body in a 20-year-old male treated by curettage and bone graft. There was no recurrence at 1year follow-up. A case report and review of the literature are presented.

  • PDF

A Study on the Analysis and Corner Joint Design of Underground R.C Box Structure (지하의 철근콘크리트 박스구조물의 해석 및 우각부 설계에 관한 연구)

  • 오병환;채성태;신호상;김의성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.04a
    • /
    • pp.253-257
    • /
    • 1996
  • A basic assumption in the current design and analysis of reinforced concrete(RC) box structures, which are constructed by the open cut and fill method, is that the displacements and forces are uniform in the longitudinal direction of the structure. The solution may be therefore obtatined from the analysis of a unit wide strip along longitudinal axis. This strip is said to be in a plane strain condition, meaning that the out of plane deformations are vanished. The current design of box structure is carried out by the result of planar frame model for the sake of simplicity. The purpose of this study is to show more rational design method of box culverts considering a rigid zone of corner joints. The current analysis of box structures will be compared with the plane strain analysis as well as 3-d shell model. Reinforcement quantity is also determined to resist the tensile force in corner joints of box structures using strut-tie model which has been developed through the elastic analysis.

  • PDF

An Experimental Study on the Structural Behavior of Strengthened Reinforced Concrete Columns (보강된 철근콘크리트 기둥의 구조거동에 관한 실험적 연구)

  • 이승엽;정성원;황규표;장성재;음성우;이수곤
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.665-672
    • /
    • 1997
  • In this paper, sixteen column specimens were tested under the concentrated and excentric load condition to examine the structural behavior of strengthened columns. 16 column specimens were divided into four groups. One group is not strengthened, the other three groups are strengthened by the materials : 1) steel plate, 2) carbon fiber sheet, and 3) glass fiber sheet, each group is composed of four specimens. As a result, strengthened columns have larger bearing capacity and energy absorption after ultimate load than unstrengthened columns. The column group strengthened with steel plate has the best bearing capacity among the strengthened column groups. Also, the columns strengthened with the carbon fiber sheet are similar to glass fiber sheet in bearing capacity. If necessary to strengthen columns in trouble, car should be taken to treat the joint between beam and column because of crack propagation in tension side.

  • PDF

Bond characteristics by joint condition between old and. new concrete (신ㆍ구 콘크리트의 접합면 조건에 다른 부착특성)

  • 주봉철;김영진;김병석;박성룡;김덕진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.859-864
    • /
    • 2003
  • In these days, the deterioration of bridges make it necessary for decks to be replaced and it is inevitable to apply the precast decks to minimize the traffic control induced from the deck placement. This precast deck construction makes the physically discontinuous interface between old and new concrete. Usually, the adhesive force at this interface are ignored. However, for crack behavior and reliable long term behavior, it is required to evaluate the exact value of the cohesive force at the interface. This research investigates the cohesive characteristics at the interface. Four different interface surface conditions are tested and three different methods are used to measure the cohesive strength at the interface. In addition, cohesive characteristic at the surface between precast panels are investigated with different interface surface conditions.

  • PDF

Grouting Effect of Rock Joint (암반절리면에서의 그라우팅 효과)

  • 이영남;천병식;김대영
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.265-270
    • /
    • 2000
  • AESTRACI: The shmr behior of sawtoothed artrjicial joints grouted with cement milk rm investiguted in the lahotconstant normal stress conditions. Tests were amducted on joints with asperities h i n g inclinations cf 16.7" and 26.6" ,strengths h i n g 15MPa and 47MPa under a given nmge of n o d stresses wrying frcm 0.76 to 1.g MPa md at a freepitching, rolling and dihtmuy. Results show that the gect of asperities on shmr strength increme is signifamt up to as,to grout thidness (t/a) mtio 4 0.3-1.0. Increme of ahesim is the nmn muse cf shmr strength increme in cemmtoothed artificial iointsed artificial ioints

  • PDF