• Title/Summary/Keyword: Jitter Analysis

Search Result 246, Processing Time 0.028 seconds

Analysis of STSAT-3 Jitter due to the Reaction Wheel Disturbance (반작용 휠의 외란에 의한 STSAT-3 지터 분석)

  • Kim, Dong-Hoon;Cheon, Dong-Ik;Oh, Hwa-Suk;Lee, Sangchul;Bang, Hyochoong;Rhee, Seung-Wu
    • Journal of Aerospace System Engineering
    • /
    • v.1 no.3
    • /
    • pp.32-36
    • /
    • 2007
  • When the reaction wheel rotates, the disturbance occurs mainly due to the mass imbalance. It is necessary to predict the effect of disturbance on the attitude stability of the satellite. The disturbance forces and torques are identified and the attitude jitter of the satellite is analyzed depending on the configuration of the wheels. On the analysis the equation of the satellite motion is combined with the translational and rotational dynamics of the wheels. The accuracy of analysis is verified by simulation of STSAT-3 satellite.

  • PDF

Analysis of Pointer Adjustment Jitter Generated in Degraded Mode with Computer Simulation (비정상인 모드에서 발생되는 포인터조정지터의 컴퓨터 시뮬레이션에 의한 분석)

  • Choe, Seung-Guk
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.4
    • /
    • pp.561-566
    • /
    • 1995
  • In the degraded mode, there is frequency-misalignment between the node clocks in a synchronous network. Therefore the phase differences between node clocks fluctuate greatly. To keep the phase difference under allowable level the pointer adjustment technique is used Unfortunately these processes cause an inherent pointer adjustment jitter, that accumulates in a chain of pointer adjustment systems. To analyze the jitter, computer simulation is carried and the results is compared with experimental jitter values.

  • PDF

VCR DRUM ASSEMBLY에 적용한 오일윤활 빗살무늬 저어널 베어링 해석

  • 강경필;임윤철;성기로
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.36-40
    • /
    • 1996
  • A numerical analysis is performed about the static and dynamic characteristics of the oil-lubricated herringbone-grooved journal bearing which has circular groove profile. Some tests of jitter and W/F measurements are carried out to verify the performance of the newly designed drum assembly.

  • PDF

Voice Analysis of Vocal Polyp and Vocal Nodule Before and after Microlaryngeal Surgery (후두미세수술 전후의 성대 용종 및 결절 환자의 음성분석)

  • Hong, Jong-Chul;Lee, Kang-Dae;Kim, Woo-Sung;Jang, Ae-Lan;Kim, Kyung-A;Kwon, Soon-Bok
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.20 no.1
    • /
    • pp.42-46
    • /
    • 2009
  • Background and Objectives : Vocal polyps and nodules are representative chronic benign laryngeal disease. Treatment options for vocal polyp and nodule in general include voice therapy or laryngeal microsurgery. The purpose of this study was to analyze voice results before and after laryngeal microsurgery. Materials and Method: Vocal polyp and vocal nodule patients were treated by laryngeal microsurgery from March 2004 to December 2006 at Kosin University Hospital. All were women. Voice analysis studies were done before and after laryngeal microsurgery. Five measurements were performed: MPT, Fo, jitter, shimmer and NHR. Results: There was significant improvement in the vocal polyp patients regarding MPT, jitter, shimmer and NHR. Also there was significant improvement in the vocal nodule patients regarding MPT, jitter and shimmer. Conclusion: MPT, jitter, shimmer and NHR will be effective acoustic parameters in documenting the quantitative changes in the vocal polyp patients. MPT, jitter and shimmer will be effective acoustic parameters in documenting the quantitative changes in the vocal nodule patients before and after laryngeal microsurgery.

  • PDF

Measurement of Cardiac Function Improvement by Auricular Acupuncture Applying Speech Signal Analysis (음성신호 분석을 적용한 이침요법(耳針療法)에 따른 심장 기능 향상 측정)

  • Kim, Bong-Hyun;Cho, Dong-Uk;Han, Kil-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5588-5593
    • /
    • 2011
  • In this paper, measure of change the speech analysis parameter by stimulating ears blood points corresponding to cardiac. To do this, we collected voice of before and after a stimulation corresponding points to ears to select normal heart having 10 subjects. We analyzed changes before and after corresponding points to ear in cardiac to apply Jitter, the second zFormant Frequency Bandwidths related to heart of elements of voice analysis. As a result of us experiment, we were able to analyze correlation of voice with cardiac according to corresponding points to ears decreased values of Jitter, the Second Formant Frequency Bandwidths of 90% of subjects. Finally, the effectiveness of proposed method is demonstrated by several experiments.

An Analysis of Service Quality affected by Allowing Maximum Delay Jitter (최대 지연지터의 허용이 서비스 품질에 미치는 영향에 대한 분석)

  • Lee, Keun-Wang
    • Journal of KIISE:Information Networking
    • /
    • v.27 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • It is important interest for us to solve skew problem in intermedia synchronization and to solve jitter problem in intramedia synchronization. It propose multimedia synchronization model to represent mixed media which contain temporal media and spatial media, and that helps us to develop multimedia application software efficiently. The proposed paper use four parameters to deal with QoS of intermedia synchronization and relative duration time algorithm and jitter-compensatory time algorithm are presented. When key medium is destroyed we make a delay as much as maximum delay jitter of the key medium in order to playout the other medium as much as that. The result is that the application of maximum delay jitter improves the service quality.

  • PDF

Acoustic Qualities of Phonation in Hearing-impaired Male Adults (청각장애 성인 남성의 음성 특성)

  • Sehr, Kyoung-Hee
    • MALSORI
    • /
    • no.65
    • /
    • pp.37-49
    • /
    • 2008
  • The purposes of this experiment were to compare and analyze some voice parameters of the hearing impaired male adults and to suggest a basic data on the speech intervention for the hearing impaired. Voice analysis of four sustained vowels(/a/, /i/, /${\partial}$/, /u/, fundamental Sequency(F0), jitter percent, shimmer percent, and Noise to Harmonic Ratio(NHR) was conducted for the deaf young male adults using a sign laguage(N=5, aged 16-20) and the normal hearing young male adults(N=10, aged 18-20) by using MDVP(Multi-Dimensional Voice Program) in CSL. F0, jitter, and shimmer in the deaf group were significantly higher than those in the normal hearing group. The average of F0 was 151 Hz, which was lower than the results of the previous studies, and there were no significant differences among the sustained vowels. In both groups, the values of the voice parameters were stable on the /a/ or /${\partial}$/, those closed to the standard scores.

  • PDF

The acoustical analysis of knee sound for non-invasive diagnosis of articular pathology (비침습적 관절 질환 모니터링을 위한 슬관절 음향분석)

  • Kim Keo-Sik;Park Gyung-Se;Kim Kyeong-Seop;Song Chul-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.12
    • /
    • pp.737-740
    • /
    • 2005
  • This paper describes the possibility of evaluating and classifying arthritic pathology using the acoustical analysis of knee joint sound. Six normal subjects and 11 patients with knee problems were enrolled. Patients were divided into the 1st patient group which required an orthopeadic surgery and the 2nd patient group of osteoarthritis. During sitting and standing periods, subjects' active knee flexion and extension were monitored. Fundamental frequency, mean amplitude of pitch, jitter and shimmer were analyzed according to the position. The results demonstrate that the values of fundamental frequency, jitter and shimmer of the 2nd patient group were larger than others and changed unstably. The values of the standing position were larger than the sitting position.

Voice Change Associated with Swallowing Disorder Caused by a Stroke After Neuromuscular Electrical Stimulation (뇌졸중으로 인한 삼킴장애 환자의 경부근육전기자극치료에 따른 음성 변화)

  • Byeon, Hae-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1665-1671
    • /
    • 2012
  • The purpose of this study was to look into changes in voice using acoustic analysis during the process of neuromuscular electrical stimulation targeting dysphagia treatment. Fifteen man with dysphagia caused by stroke was treated neuromuscular electrical stimulation for two months and intensity of voice, $F_0$, Jitter, Shimmer, NNE were measured. The results of this study that improvement in functions of dysphagia and Jitter, Shimmer were stabilized. But there was not significantly changes of $F_0$. NNE was improved after the intervention, but still showed abnormal levels. This result suggests a possibility of effects that Neuromuscular electrical stimulation has on stabilization of Jitter, Shimmer and intensity of voice.

Analysis of Correlation between Sleep Interval Length and Jitter Buffer Size for QoS of IPTV and VoIP Audio Service over Mobile WiMax (Mobile WiMAX에서 IPTV 및 VoIP 음성서비스 품질을 고려한 수면구간 길이와 지터버퍼 크기의 상관관계 분석)

  • Kim, Hyung-Suk;Kim, Tae-Hyoun;Hwang, Ho-Young
    • The KIPS Transactions:PartC
    • /
    • v.17C no.3
    • /
    • pp.299-306
    • /
    • 2010
  • IPTV and VoIP services are considered as killer applications over Mobile WiMAX network, which provideshigh mobility and data rate. Among those which affect the quality of voice in those services, the jitter buffer or playout buffer can compensate the poor voice quality caused by the packet drop due to frequent route change or differences among routes between service endpoints. In this paper, we analyze the correlation between the sleep interval length and jitter buffer size in order to guarantee a predefined level of voice quality. For this purpose, we present an end-to-end delay model considering additional delay incurred by the WiMAX PSC-II sleep mode and a VoIP service quality requirement based on the delay constraints. Through extensive simulation experiments, we also show that the increase of jitter buffer size may degrade the voice quality since it can introduce additional packet drop in the jitter buffer under WiMAX power saving mode.