• 제목/요약/키워드: Jet Temperature

검색결과 694건 처리시간 0.03초

Glidarc 워터젯 플라즈마를 이용한 톨루엔 분해 특성 (Decomposition Characterist of Toluene Using a Glidarc Water-jet Plasma)

  • 김성천;전영남
    • 한국대기환경학회지
    • /
    • 제24권3호
    • /
    • pp.329-335
    • /
    • 2008
  • Volatile organic compounds emitted to the atmosphere can cause adverse effects on human health and participate in photochemical smog formation reactions. The destruction of a series of VOCs has been carried out by non-thermal plasma in other researches. And the characteristic of non-thermal plasma was operated at atmospheric pressure and low temperature. A new type non-thermal plasma reactor was investigated combined Glidarc plasma with water jet in this research. Also, it was found that the water-jet had an significant effect on the toluene removal efficiency. But too much water content does not favor toluene decomposition by decreasing of reaction temperature. The input toluene concentration, gas flow rate, water flow rate and specific energy input were used as experiment variables. The toluene removal efficiency, energy efficiency and specific energy input were 75.3%, 146.6 g/kWh and $1.12kWh/m^3$ at a water flow rate of 100 mL/min.

가스 및 분무화염의 연소소음 특성에 관한 실험연구 (Combustion Noise Characteristics in Gas and Liquid Flames)

  • 김호석;백민수;오상헌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권1호
    • /
    • pp.81-91
    • /
    • 1994
  • Combustion noise involved with chemical heat release and turbulent process in turbopropulsion systems, gasturbine, industrial furnaces and internal engines is indeed noisy. The experimental study reported in this paper is made to identify a dominant combustion noise in jet flames. Gaseous propane and kerosene fuel have been used with air as the oxidizer in a different jet combustion systems. Combustion and aerodynamic noise are studied through far field sound pressure measurements in an anechoic chamber. And also mean temperature and velocities and turbulent intensities of both isothermal and reacting flow fields were measured. It is shown that axial mean velocity of reacting flow fields is higher about 1 to 3m/sec than that of cold flow in a gaseous combustor. As the gaseous fuel flow rate increases, the acoustic power increases. But the sound pressure level for the spray flame decreases with increasing equivalence ratio. The influence of temperature in the combustion fields due to chemical heat release has been observed to be a dominant noise source in the spray flame. The spectra of combustion noise in gaseous propane and kerosene jet flame show a predominantly low frequency and a broadband nature as compared with the noise characteristics in an isothermal air jet.

  • PDF

전개확산제트화염과 정체점 확산화염과의 유사성 (Similarity between a stagnant point diffusion flame and an evolving jet diffusion flame)

  • 박정;신현동
    • 대한기계학회논문집B
    • /
    • 제21권4호
    • /
    • pp.494-502
    • /
    • 1997
  • Experiments on corresponding jet flames with stagnant point diffusion flames have been carried out in initial injection periods. A compensated measurement of maximum flame temperature, which is based on the ion signal, has been employed to inspect flame responses to time-varying strain rates. The flame responses are obtained at two conditions for the slowly time-varying strain rate and the case of flame extinction, and analyzed to confirm similarity between a stagnant point diffusion flame and an evolving jet diffusion flame. Nonsteady effects are addressed via the comparison between several time scales. The time variation with low strain rates, in which illustrates the flame behavior of the upper branch far from extinction in the well-known S-curve, is confirmed to produce a quasi-steady flame response through the nonsteady experiments. The time variation with strain rates in the case of flame extinction indicates an unsteady effect of flame response. It is therefore found that the flame responses near jet tip depend on time histories of characterized strain rates in the developing process.

PIV 기법을 이용한 비등온 부력제트의 유동구조에 관한 연구 (Velocity Field Measurements of a Vertical Turbulent Buoyant Jet Using a PIV Technique)

  • 신대식;윤정환;이상준
    • 대한기계학회논문집B
    • /
    • 제25권5호
    • /
    • pp.611-618
    • /
    • 2001
  • The flow characteristics of a turbulent buoyant jet were experimentally investigated using a single-frame PIV system. The Reynolds number based on the nozzle exit velocity and nozzle diameter was about Re=5$\times$10$^3$. The instantaneous velocity fields in the streamwise plane passing the jet axis were measured in the near field X/D <11 with and without the temperature gradient. By ensemble averaging the instantaneous velocity fields, the spatial distributions of mean velocity, vorticity, and higher-order statistics up to third order were obtained. The temperature difference of 10$\^{C}$ does not affect a significant influence to the flow structure in the near field, but the total entrainment rate is increased slightly. The entrainment rate shows a linear variation with the streamwise distance in the region after X/D=5.0.

평면충돌제트에 의한 고온 판 냉각과정의 열전달 해석 (Analysis of Heat Transfer in Cooling of a Hot Plate by Planar Impingement Jet)

  • 안대환;김동식
    • 대한기계학회논문집B
    • /
    • 제33권1호
    • /
    • pp.17-27
    • /
    • 2009
  • Water jet impingement cooling is used to remove heat from high-temperature surfaces such as hot steel plates in the steel manufacturing process (thermo-mechanical cooling process; TMCP). In those processes, uniform cooling is the most critical factor to ensure high strength steel and good quality. In this study, experiments are performed to measure the heat transfer coefficient together with the inverse heat conduction problem (IHCP) analysis for a plate cooled by planar water jet. In the inverse heat transfer analysis, spatial and temporal variations of heat transfer coefficient, with no information regarding its functional form, are determined by employing the conjugate gradient method with an adjoint problem. To estimate the two dimensional distribution of heat transfer coefficient and heat flux for planar waterjet cooling, eight thermo-couple are installed inside the plate. The results show that heat transfer coefficient is approximately uniform in the span-wise direction in the early stage of cooling. In the later stage where the forced-convection effect is important, the heat transfer coefficient becomes larger in the edge region. The surface temperature vs. heat flux characteristics are also investigated for the entire boiling regimes. In addition, the heat transfer rate for the two different plate geometries are compared at the same Reynolds number.

Measurement of electron density of atmospheric pressure Ar plasma jet by using Michelson interferometer

  • Lim, Jun-Sup;Hong, Young June;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.195.1-195.1
    • /
    • 2016
  • Currently, as Plasma application is expanded to the industrial and medical industrial, low temperature plasma applications became important. Especially in medical and biology, many researchers have studied about generated radical species in atmospheric pressure low temperature plasma directly adapted to human body. Therefore, so measurement their plasma parameter is very important work and is widely studied all around world. One of the plasma parameters is electron density and it is closely relative to radical production through the plasma source. some kinds of method to measuring the electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods have very expensive cost and complex configuration to composed of experiment system. We selected Michelson interferometer system which is very cheap and simple to setting up, so we tried to measuring electron density by laser interferometer with laser beam chopping module for measurement of temporal phase difference in plasma jet. To measuring electron density at atmospheric pressure Ar plasma jet, we obtained the temporal phase shift signal of interferometer. Phase difference of interferometer can occur because of change by refractive index of electron density in plasma jet. The electron density was able to estimate with this phase difference values by using physical formula about refractive index change of external electromagnetic wave in plasma. Our guiding laser used Helium-Neon laser of the centered wavelength of 632 nm. We installed chopper module which can make a 4kHz pulse laser signal at the laser front side. In this experiment, we obtained more exact synchronized phase difference between with and without plasma jet than reported data at last year. Especially, we found the phase difference between time range of discharge current. Electron density is changed from Townsend discharge's electron bombardment, so we observed the phase difference phenomenon and calculated the temporal electron density by using phase shift. In our result, we suggest that the electron density have approximately range between 1014~ 1015 cm-3 in atmospheric pressure Ar plasma jet.

  • PDF

가을철 동해 표층 수온과 태평양 순년 진동의 상관성 분석 (Correlation between the Pacific Decadal Oscillation and East/Japan Sea SST in the Autumn)

  • 박균도
    • 한국해양학회지:바다
    • /
    • 제24권4호
    • /
    • pp.509-518
    • /
    • 2019
  • 다양한 표층 수온 자료를 통해 1979년부터 2018년 기간 동안의 가을철 동해 공간 평균 표층 수온이 태평양 순년 진동과 높은 상관관계를 나타내는 것을 확인하였다. 이 해역에서 제트류의 활동이 가장 강한 200 hPa에서의 바람과 동해 표층 수온의 회귀 분석 결과, 가을철 동해 표층 수온이 상승할 때 제트류의 중심축이 북상하면서 전반적으로 제트류가 약화하는 경향을 보이며, 동해 수온이 하강할 때는 제트류의 중심축이 남하하면서 제트류가 강화되는 경향을 보였다. 이러한 분석 결과는 제트류의 강도 변화와 중심축의 남북 진동이 동해 표층 수온과 태평양 순년 진동의 커플링과 관련되어 있음을 시사한다. 여름철의 약한 제트류와 겨울철 및 이른 봄철의 강한 동아시아 동계계절풍 효과는 동해와 태평양 순년 진동의 커플링이 가을철 외의 다른 계절에 잘 나타나지 않게 하는 이유로 생각해볼 수 있다.

디지털 프린팅용 세라믹 잉크의 유약표면 인쇄적성 및 특성평가 (Printability of digital color ceramic ink on glazed surface of ink-jet printed ceramic tile)

  • 김진호;황광택;조우석;한규성
    • 한국결정성장학회지
    • /
    • 제27권5호
    • /
    • pp.256-262
    • /
    • 2017
  • $1000^{\circ}C$ 이상의 고온에서도 안정적인 발색 특성을 보이는 세라믹 잉크를 활용한 디지털 프린팅 기술은 우수한 내구성을 가지는 제품을 다양한 디자인을 적용하여 생산할 수 있는 친환경 공정이라는 장점으로 인해 최근 관심이 높아지고 있다. 특히 건축용 세라믹 타일 산업에서 잉크젯 프린팅 기술 도입을 통한 디지털 공정으로의 전환은 점점 가속화되고 있으며, 이와 관련된 프린팅 시스템 및 고온발색 세라믹 잉크에 관한 연구가 활발히 진행되고 있다. 본 연구에서는 세라믹 타일의 표면 유약층에서 고온발색 세라믹 잉크의 인쇄적성을 분석하였다. 디지털 4원색인 Cyan, Magenta, Yellow, Black 색상의 고온발색 세라믹 잉크가 프린팅된 세라믹 타일의 표면 및 단면의 미세구조를 분석함으로써 세라믹 잉크의 종류에 따른 인쇄특성에 대해 비교하였다. 또한 고온 열처리 공정이 필수적으로 요구되는 세라믹 소재의 특성상 잉크젯 프린팅 후 세라믹 잉크 패턴의 열처리 공정에 따른 거동변화에 관하여 고찰하였으며, 세라믹 타일 유약층에서 세라믹 잉크의 인쇄적성은 미세구조 및 고온 소성 과정에 큰 영향을 받고 있음을 확인하였다.

IN VITRO STUDY ON EXOTHERMIC REACTION OF POLYMER-BASED PROVISIONAL CROWN AND FIXED PARTIAL DENTURE MATERIALS MEASURED BY DIFFERENTIAL SCANNING CALORIMETRY

  • Ko, Mun-Jeung;Pae, Ahran;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.690-698
    • /
    • 2006
  • Statement of problems. The heat produced during polymerization of polymer-based provisional materials may cause thermal damage to the vital pulp. Purpose. This study was performed to evaluate the exotherm reaction of the polymerbased provisional materials during polymerization by differential scanning calorimetry and to compare the temperature changes of different types of resins. Material and methods. Three dimethacrylate-based materials (Protemp 3 Garant, Luxatemp Plus, Luxatemp Fluorescence) and five monomethacrylate- based material (Snap, Alike, Unifast TRAD, Duralay, Jet) were selected. Temperature changes of polymer-based provisional materials during polymerization in this study were evaluated by D.S.C Q-1000 (TA Instrument, Wilmington, DE, USA). The following three measurements were determined from the temperature versus time plot: (1) peak temperature, (2) time to reach peak temperature, (3) heat capacity. The data were statistically analyzed using one-way ANOVA and multiple comparison Bonferroni test at the significance level of 0.05. Results. The mean peak temperature was $39.5^{\circ}C({\pm}\;1.0)$. The peak temperature of the polymer-based provisional materials decreased in the following order: Duralay > Unifast TRAD, Alike > Jet > Luxatemp Plus, Protemp 3 Garant, Snap, Luxatemp Fluorescence. The mean time to reach peak temperature was 95.95 sec $({\pm}\;64.0)$. The mean time to reach peak temperature of the polymer-based provisional materials decreased in the following order: Snap, Jet > Duralay > Alike > Unifast TRAD > Luxatemp Plus, Protemp 3 Garant, Luxatemp Fluorescence. The mean heat capacity was 287.2 J/g $({\pm}\;107.68)$. The heat capacity of the polymer-based provisional materials decreased in the following order: Duralay > TRAD, Jet, Alike > Snap, Luxatemp Fluorescence, Protemp 3 Garant, Luxatemp Plus. Conclusion. The heat capacity of materials, determined by D.S.C., is a factor in determining the thermal insulating properties of restorative materials. The peak temperature of PMMA was significantly higher than others (PEMA, dimethacrylate). No significant differences were found among PEMA (Snap) and dimethacrylate (P >0.05). The time to reach peak temperature was greatest with PEMA, followed by PMMA and dimethacrylate. The heat capacity of PMMA was significantly higher than others (PEMA, dimethacrylate). No significant differences were found among PEMA and dimethacrylate (P >0.05).

2次元 亂流 Stepped Wall Jet 의 流動特性 (Flow Characteristics of Two-Dimensional Turbulent Stepped Wall Jet)

  • 부정숙;김경천;박진호;강창수
    • 대한기계학회논문집
    • /
    • 제9권6호
    • /
    • pp.732-742
    • /
    • 1985
  • 본 논문에서는 이 2차원 재부착분류(본문에서는 stepped wall jet라 명명함) 유동장을 재부착상류 부분, 재부착점 근방, 재부착 이후의 재발전 벽면분류 지역의 세 영역으로 구분하여 재부착 길이, 평균속도, 벽면정압을 측정하고 on-line에 의한 디지 틀 데이터 처리기법을 이용하여 난류강도, 레이놀즈 전단응력, 속도의 3승적(triple velocity product), integral length scale, Taylor's microscale 등을 실험적으로 구 하여 재부착 상류 부분에서는 자유분류와 비교하고, 재부착 이후에서는 2차원 벽면분 류와 비교하기로 한다.그리하여 초기 교란을 받는 분류가 벽면에 재부착하여 2차원 벽면분류로 재발전되어 가는 과정에 있어서의 평균 유동장과 급격한 변화를 갖는 난류 특성을 상세히 조사하여, 보다 일반적으로 적용될 수 있는 난류모델을 개발함에 있어 서 실험적인 자료를 제공하고자 한다. Fig. 1은 본 실험의 유동장에 대한 개약도를 보여주고 있다.