• Title/Summary/Keyword: Jet Injection

Search Result 346, Processing Time 0.02 seconds

Reduction of a Numerical Grid Dependency in High-pressure Diesel Injection Simulation Using the Lagrangian-Eulerian CFD Method (Lagrangian-Eulerian 기법을 이용한 고압 디젤 분무 시뮬레이션의 수치해석격자 의존성 저감에 관한 연구)

  • Kim, Sa-Yop;Oh, Yun-Jung;Park, Sung-Wook;Lee, Chang-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.39-45
    • /
    • 2012
  • In the standard CFD code, Lagrangian-Eulerian method is very popular to simulate the liquid spray penetrating into gaseous phase. Though this method can give a simple solution and low computational cost, it have been reported that the Lagrangian spray models have numerical grid dependency, resulting in serious numerical errors. Many researches have shown the grid dependency arise from two sources. The first is due to unaccurate prediction of the droplet-gas relative velocity, and the second is that the probability of binary droplet collision is dependent on the grid resolution. In order to solve the grid dependency problem, the improved spray models are implemented in the KIVA-3V code in this study. For reducing the errors in predicting the relative velocity, the momentum gain from the gaseous phase to liquid particles were resolved according to the gas-jet theory. In addition, the advanced algorithm of the droplet collision modeling which surmounts the grid dependency problem was applied. Then, in order to validate the improved spray model, the computation is compared to the experimental results. By simultaneously regarding the momentum coupling and the droplet collision modeling, successful reduction of the numerical grid dependency could be accomplished in the simulation of the high-pressure injection diesel spray.

ADVANCED DVI+

  • Kwon, Tae-Soon;Lee, S.T.;Euh, D.J.;Chu, I.C.;Youn, Y.J.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.727-734
    • /
    • 2012
  • A new advanced safety feature of DVI+ (Direct Vessel Injection Plus) for the APR+ (Advanced Power Reactor Plus), to mitigate the ECC (Emergency Core Cooling) bypass fraction and to prevent switching an ECC outlet to a break flow inlet during a DVI line break, is presented for an advanced DVI system. In the current DVI system, the ECC water injected into the downcomer is easily shifted to the broken cold leg by a high steam cross flow which comes from the intact cold legs during the late reflood phase of a LBLOCA (Large Break Loss Of Coolant Accident)For the new DVI+ system, an ECBD (Emergency Core Barrel Duct) is installed on the outside of a core barrel cylinder. The ECBD has a gap (From the core barrel wall to the ECBD inner wall to the radial direction) of 3/25~7/25 of the downcomer annulus gap. The DVI nozzle and the ECBD are only connected by the ECC water jet, which is called a hydrodynamic water bridge, during the ECC injection period. Otherwise these two components are disconnected from each other without any pipes inside the downcomer. The ECBD is an ECC downward isolation flow sub-channel which protects the ECC water from the high speed steam crossflow in the downcomer annulus during a LOCA event. The injected ECC water flows downward into the lower downcomer through the ECBD without a strong entrainment to a steam cross flow. The outer downcomer annulus of the ECBD is the major steam flow zone coming from the intact cold leg during a LBLOCA. During a DVI line break, the separated DVI nozzle and ECBD have the effect of preventing the level of the cooling water from being lowered in the downcomer due to an inlet-outlet reverse phenomenon at the lowest position of the outlet of the ECBD.

Effect of Injection Angle and Length to Diameter Ratios on Drop and Penetration Characteristics in Cross-flow (아름속 횡단 기체 유동장에서 노즐 형상 변화와 분사각 변화가 액적크기와 침투거리에 미치는 영향)

  • Lee, Bong-Soo;Ko, Jung-Bin;Cho, Woo-Jin;Koo, Ja-Ye
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.6
    • /
    • pp.51-58
    • /
    • 2006
  • The spray characteristics of liquid jet injected into subsonic cross-flow were investigated experimentally. Spray trajectories were captured using CCD camera. Droplet sizes were measured using PDPA and Image Express. The nozzle diameter was 0.5 mm, and its length-to-diameter ratios (L/D) ran$4.11{\times}10^6$ged from 1.0 to 6.0. Experimental results indicate that the breakup point is delayed by increasing gas momentum ratio and the penetration length is decreased by increasing Weber number. At low injection angle(${\theta}$ < $90^{\circ}$), Weber number is dominant parameter for trajectories, but at high injection angle(${\theta}$ > $90^{\circ}$), L/D is dominant parameter for trajectories rather than Weber number.

Combustion Characteristics Study using Hyper-mixer in Low-enthalpy Supersonic Flow (하이퍼 혼합기를 사용한 저엔탈피 초음속 유동장 내연소 특성 연구)

  • Kim, Chae-Hyoung;Jeung, In-Seuck
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.6
    • /
    • pp.75-80
    • /
    • 2013
  • In this study, a forced ignition method with a plasma jet torch is studied in Mach 2 laboratory scaled wind-tunnel. The hyper-mixer is used as a mixer. For two normal injection cases, the one is collided against a wedge plate of the hyper-mixer and the other is directly injected into the cold main flow. For the first case, the hyper-mixer disperses the injected fuel, leading to the mixing enhancement. Furthermore, the fuel-air mixture is provided into the plasma hot gas, which enhances the combustion performance. However, the direct injection into the main flow method spends amount of fuel without ignition in the cold supersonic flow. In the end, for the forced combustion, it is important to supply the fuel-air mixture into the heat source.

Combustion Characteristics of a Double-cone Partial Premixed Nozzle with Various Fuel hole Patterns (이중 콘형 부분 예혼합 GT 노즐의 연료 분사구 형상 변화에 대한 연소특성)

  • Kim, Han Seok;Cho, Ju Hyeong;Kim, Min Kuk;Hwang, Jeongjae;Lee, Won June
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.25-31
    • /
    • 2020
  • Experimental investigations were conducted to examine the combustion characteristics of a swirl-stabilized double cone premixed burner nozzle used for industrial gas turbines for power generation. Several variants with different fuel injection patterns are tested to compare the combustion characteristics such as NOx and CO emissions, stability, and wall temperature distributions. Main results show that NOx emissions and stability are decreased either when the fuel hole diameter is decreased with the same number of fuel holes, or when the number of fuel holes is reduced with the same total area of fuel holes, both of which are due to a higher penetration of fuel into the air stream. Not only is NOx reduced but also stability is enhanced when the fuel hole diameter varies in an alternating manner with the same total area of fuel holes, showing that NOx reduction is due to a higher penetration of mean fuel injection path while stability enhancement is due to a lowered penetration of minimum fuel injection path.

Analysis of effect of hydrogen jet fire on tunnel structure (수소 제트화염이 터널 구조체에 미치는 영향 분석)

  • Park, Jinouk;Yoo, Yongho;Kim, Whiseong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.535-547
    • /
    • 2021
  • A policy to expand the hydrogen economy has been established in Korea and the supply of FCEV is being expanded to realize a hydrogen society. Therefore, the supply of FCEV is expected to increase rapidly, and a solution to respond to accidents of FCEV is required. In this study, an experimental study was conducted to analyze the effect of the hydrogen jet flame generated by a FCEV on the inner wall of the tunnel and the characteristics of the internal radiant heat. For the experiment, the initial pressure of hydrogen tank was set to 700 bar, and the injection nozzle diameter was set to 1.8 mm in order to make the same as the conditions generated in the FCEV. In addition, a tunnel fire resistance test specimen having the same strength as the compressive strength of concrete applied to general tunnels of 40 MPa was manufactured and used in the experiment. The results were analyzed for the separation distance (2 m and 4 m) between the hydrogen release nozzle and the tunnel fire resistance test concrete. As the result, the maximum internal temperature of the test concrete was measured to 1,349.9℃ (2 m separation distance), and the radiant heat around the jet flame was up to 39.16 kW/m2.

A Study Pressure drop Variance of Pulse interval, injection distance in Pulse-Jet Type Fabric Filter (충격기류식 여과집진장치의 펄스간격 및 분사거리에 따른 압력손실변화에 관한 연구)

  • 서정민;정찬호;최금찬;박정호
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.102-103
    • /
    • 2003
  • 최근 고도 경제성장으로 인한 공업화와 그에 따른 업종이 다양해짐에 따라 여기에 수반되어 발생되는 대기오염물질이 증가할 뿐만 아니라 종류도 여러가지로 다양해지고 있다. 대부분 산업공정에서 배출되는 미세먼지 입자는 기존의 집진장치로 거의 포집제거가 불가능하여 대부분이 대기중으로 방출되고 있는 실정이다. 분진 중에서도 입경 l$\mu\textrm{m}$이하의 분진들은 침강 속도가 작아 거의 gas와 동일한 거동을 하기 때문에 기관 또는 폐포에 침착하여 호흡기에 영향을 미치므로 그 발생량과 화학적 성상이 문제화되고 있는 추세이다. (중략)

  • PDF

Development of a Simplified Design Method for LBB Application to Nuclear Piping (원전 배관의 LBB 개념 적용을 위한 간략 설계기법 개발)

  • 허남수;이철형;김영진;석창성;표창률
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.32-41
    • /
    • 1999
  • If the Leak-Before-Break (LBB) concept is applicable to the nuclear piping design, it is not necessary to consider the dynamic effect due to pipe rupture. Therefore, the construction cost can be significantly reduced by eliminating unnecessary pipe whip restraints and jet impingement devices. The objective of this paper is to develop the Piping Evaluation Diagram (PED) for efficient application of LBB concept to piping system at an initial piping design stage. For this purpose, the 3-D finite element analyses were performed to evaluate the crack stability. And the stress-strain curve based on the pipe material tests were used to calculate the detectable leakage crack length. Finally, the present PED which was composed as a function of NOP load and allowable SSE load, was developed for an application of LBB concept to the safety injection and shutdown cooling line in Korean Next Generation Reactor (KNGR).

  • PDF

NUMERICAL ANALYSIS OF A 150KW HUELS TYPE ARC HEATER (150kW급 Huels형 아크 히터 내부의 유동 해석)

  • Han, S.H.;Byeon, J.Y.;Kim, K.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2010.05a
    • /
    • pp.562-566
    • /
    • 2010
  • Numerical analysis of 150kW Huels-type arc jet was performed using compressible Navier-Stokes CFD code. To consider chemical reaction by high temperature, the flow was assumed to be chemical equilibrium states. As a turbulence and a radiation model, the two-equation k-epsilon model and the 3-band radiation model were adopted, respectively. Mass flow rate and current density were given as conditions for calculations. In this study, two kinds of mechanisms for injection of air flow wire considered. One is that air is provided by left wall surface and the other is that air is injected from upper wall surface. The pressure, density and temperature contours of two cases were compared and heat transfer rates were estimated. The numerical results of two cases were not much different to each other. However, in real 150KW device, air is injected from upper wall surface with swirl. To calculate more accurately, swirl effect is must be considered.

  • PDF

External Spray Characteristics of Deflector Nozzle (충돌형 노즐의 분무형상 연구)

  • Kim, K.H.;Choi, Y.H.;Yoon, S.J.
    • Journal of ILASS-Korea
    • /
    • v.7 no.1
    • /
    • pp.29-35
    • /
    • 2002
  • This study describes the external spray characteristics of deflector nozzle such as the breakup procedures of liquid sheet, spray angle, breakup length and bubble behaviors of spray at deflector nozzle. In order to visualize the spray behaviors shadow graphy technique were used. According to the increase injection pressure, deveopment of the spray passes through the dribbling, distoted jet, closed bubble due to the contraction by form a conical sheet like as the simplex swirl atomizer. As trying the analysis of the ratio of bubble length and width it was found that the ratios is comparable. Spray cone angle was nearly $90^{\circ}$.

  • PDF