• Title/Summary/Keyword: Jaw motion tracking

Search Result 8, Processing Time 0.019 seconds

Full-mouth rehabilitation of severely attrited dentition with missing posterior teeth: a case report using digital workflow with jaw motion tracking (심한 교모와 구치부 상실을 보이는 환자의 전악 수복: Jaw motion tracking과 digital workflow를 활용한 증례 보고)

  • Chan Young Park;Younghoo Lee;Seoung-Jin Hong;Janghyun Paek;Kwantae Noh;Ahran Pae;Hyeong-Seob Kim;Kung-Rock Kwon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.293-307
    • /
    • 2023
  • Jaw motion tracking, which is introduced in recent case reports, is a method which records the patient's individualized pathway of the mandibular movements along with facebow transfer, and reproduces the information in the virtual space of computer-aided-design/computer-aided-manufacturing (CAD-CAM) software. In this present case, a collapse of the occlusal plane was observed, due the loss of posterior teeth for a long period. Full-mouth rehabilitation with an increase in the occlusal vertical dimension was planned. First, the patient's mandibular movements were recorded on the newly established jaw relation by jaw tracking, and this information was assembled with the patient's intraoral data to create a virtual patient. Implant planning and diagnostic wax-up was done on the virtual patient, leading the fabrication of the provisional prosthesis. On the newly established jaw relation with an increase in the occlusal vertical dimension, canine guidance of the provisional prosthesis was checked. Finally, the provisional prosthesis was carried out to the definitive prosthesis. Using the advantages of the technologies in the digital dentistry, the patient was satisfied with the function and the esthetics after the treatment.

Magnetic wireless motion capturing system and its application for jaw tracking system and 3D computer input device

  • Shin Yabukami;Kaoru Arai;Arai, Ken-Ichi;Shinya Tsuji
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.12-12
    • /
    • 2002
  • We present the new jaw tracking system that utilizes five degrees of freedom of head and lower jaw. The proposed method does not disturb the physiology because the system does not need to fix magnetic field sensors or clutch on the patient's body or mouth. The impact of this result goes beyond the conventional optical and magnetic tracking system of jaw movement [1][2]. Position accuracy within 1mm and reasonable cost is necessary for practical use of the jaw tracking system. (omitted)

  • PDF

Complete mouth rehabilitation, using jaw motion tracking and double scan technique in a patient with osteoarthrosis: a case report (골관절증 환자에서 하악 운동 추적 장치와 이중 스캔 기법을 활용한 완전 구강 회복 증례)

  • Seo-Kyung Jeong;Jai-Young Koak;Seong-Joo Heo;Seong-Kyun Kim;Ji-Man Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.62 no.1
    • /
    • pp.82-94
    • /
    • 2024
  • This is a case report of complete mouth rehabilitation in a patient with generalized attrition and loss of posterior support. After analyzing the condition of the temporomandibular joint, multiple implants were placed to restore collapsed occlusion. Fixture/abutment level intraoral scanning was done instead of using conventional impression materials which entail multiple bite registration for cross-mounting. A 'jaw motion tracking'device, 'digital face-bow transfer', and 'double scan technique' which enables duplicating temporary restoration to definitive restoration were used to fabricate definitive prostheses. By using various digital techniques, complete mouth rehabilitation was done with minimal chair time in a patient with unstable occlusion.

Magnetic Wireless Motion Capturing System and its Application for Jaw Tracking System and 3D Computer Input Device

  • Yabukami, S.;Arai, K.;Arai, K.I.;Tsuji, S.
    • Journal of Magnetics
    • /
    • v.8 no.1
    • /
    • pp.70-73
    • /
    • 2003
  • We have developed a new tracking system of jaw movement. The system consists of two permanent NdFeB magnets and 32 elements of two-axial fluxgate sensor array, The two magnets are attached to head portion and front tooth. This system does not need any attachments of the head portion or mouth such as clutch or magnetic field sensor except magnets. The proposed system is applicable for five degree of freedom. Position accuracy within 2]m was achieved. We developed a 3D computer input device by using the above mentioned technique.

Mixed-reality simulation for orthognathic surgery

  • Fushima, Kenji;Kobayashi, Masaru
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.13.1-13.12
    • /
    • 2016
  • Background: Mandibular motion tracking system (ManMoS) has been developed for orthognathic surgery. This article aimed to introduce the ManMoS and to examine the accuracy of this system. Methods: Skeletal and dental models are reconstructed in a virtual space from the DICOM data of three-dimensional computed tomography (3D-CT) recording and the STL data of 3D scanning, respectively. The ManMoS uniquely integrates the virtual dento-skeletal model with the real motion of the dental cast mounted on the simulator, using the reference splint. Positional change of the dental cast is tracked by using the 3D motion tracking equipment and reflects on the jaw position of the virtual model in real time, generating the mixed-reality surgical simulation. ManMoS was applied for two clinical cases having a facial asymmetry. In order to assess the accuracy of the ManMoS, the positional change of the lower dental arch was compared between the virtual and real models. Results: With the measurement data of the real lower dental cast as a reference, measurement error for the whole simulation system was less than 0.32 mm. In ManMoS, the skeletal and dental asymmetries were adequately diagnosed in three dimensions. Jaw repositioning was simulated with priority given to the skeletal correction rather than the occlusal correction. In two cases, facial asymmetry was successfully improved while a normal occlusal relationship was reconstructed. Positional change measured in the virtual model did not differ significantly from that in the real model. Conclusions: It was suggested that the accuracy of the ManMoS was good enough for a clinical use. This surgical simulation system appears to meet clinical demands well and is an important facilitator of communication between orthodontists and surgeons.

Investigation of sunspot substructure using chromospheric bright patches in a merging sunspot

  • Cho, Kyuhyoun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.44.3-44.3
    • /
    • 2020
  • Sunspot substructure is an important subject to explain their stability and energy transport. Previous studies suggested two substructure models, monolithic and spaghetti model, but no clear evidence has been found supporting a particular model. To obtain the clue of the sunspot substructure the IRIS Mg II 2796Å slit-jaw images (SJI) were examined. The Mg II images formed in the chromosphere show bright patches inside umbrae which are regarded as an observational signature of upward propagating slow magnetohydrodynamic (MHD) waves. The slow MHD waves are expected to be generated by convective motion below the photosphere. By tracking the motion of the bright patches it is possible to estimate the locations of oscillation centers that correspond to the occurrence position of the convections. I investigated the spatial distribution of the oscillation center in a merging sunspot and found it is randomly distributed. It implies that the occurrence rate of the convective motion inside the sunspot is not much different from that of between the two sunspots, and supports the spaghetti model as the sunspot substructure.

  • PDF

3D Printed customized sports mouthguard (3D 프린터로 제작하는 마우스가드)

  • Ryu, Jae Jun;Lee, Soo Young
    • The Journal of the Korean dental association
    • /
    • v.58 no.11
    • /
    • pp.700-712
    • /
    • 2020
  • The conventional mouthguard fabrication process consists of elastomeric impression taking and followed gypsum model making is now into intraoral scanning and direct mouthguard 3D printing with an additive manufacturing process. Also, dental professionals can get various diagnostic data collection such as facial scans, cone-beam CT, jaw motion tracking, and intraoral scan data to superimpose them for making virtual patient datasets. To print mouthguards, dental CAD software allows dental professionals to design mouthguards with ease. This article shows how to make 3D printed mouthguard step by step.

  • PDF

Implant-supported fixed prosthesis in patient with severe defects using staged GBR via 2-step augmentations: A case report (심한 결손부의 단계적 골증대술을 통한 임플란트 지지 고정성 보철 수복 증례 보고)

  • Oh, SaeEun;Jun, Ji Hoon;Park, YoungBum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.382-394
    • /
    • 2022
  • The treatment of patients with severe periodontitis should be proceeded step-bystep through an accurate diagnosis of each patients' individual tooth and with a strategic treatment plan. Implant-supported fixed prosthetic restoration has the advantage of high patient satisfaction and stable vertical dimension compared to the removable partial denture. However, multiple teeth defect areas lacking hard tissue may be disadvantageous in aesthetic failure and longer treatment time. In addition, it takes a certain period of time to manufacture and install a conventional fixed prosthesis, and during this process, the provisional prosthesis must satisfy the mechanical, biological, and aesthetic requirements of teeth. The purpose of this article is to describe the fabrication of implant-supported fixed prosthesis through a step-by-step approach in a partially edentulous patient.