• Title/Summary/Keyword: Jar-test

Search Result 154, Processing Time 0.023 seconds

Automatic Determination of Coagulant Dosing Rate Using Fuzzy Neural Network (Fuzzy Neural Network에 응집제 투입률의 자동결정)

  • Chung, Woo-Seop;Oh, Sueg-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.1
    • /
    • pp.101-107
    • /
    • 1997
  • Recently, as the raw water quality becomes to be polluted and the seasonal and local variation of water quality becomes to be severe, an exact control of coagulant dosing have been required in the water treat- ment plant. The amounts of coagulant is related to the raw water quality such as turbidity, alkalinity, water temperature, pH and edectrical conductivity. However the process of chemical reaction has not been clarified so far, so the dosing rate has been decided by jar-test, which is taken one or two hours. For the sake of this coagulant dosing control, fuzzy neural network to fuse fuzzy logic and neural network was proposed, and the scheme was applied to automatic determination of coagulant dosing rate. This controller can automatically identify the if-then rules and tune the membership functions by utilizing expert's cintrol data. It is shown that determination of coagulant dosing rate according to real time sensing of water quality is very effect.

  • PDF

Repeated-Dose Toxicity Testing of Scolopendrid Pharmacopuncture in Sprague-Dawley Rats

  • Jang, Jongwon;Seo, Wookcheol;Chu, Hongmin;Park, Kyungtae;Kim, SunKyung;Park, Ju-Hun;Shin, Joon young;Choi, Dong ho;Kang, Hyung Won;Kim, Sungchul
    • Journal of Acupuncture Research
    • /
    • v.37 no.2
    • /
    • pp.110-117
    • /
    • 2020
  • Background: The aim of this pilot study was to assess the safety and dosing of scolopendrid pharmacopuncture (SPP). Methods: A total of 40 healthy Sprague-Dawley rats (males and 20 females 20) were selected following a 7-day inspection and acclimation period. SPP was administered via intramuscular injection, over a 2-week period using 3 doses including a high-dose [0.84 mg of scolopendrid per kg of body weight (BW)], a med-dose (0.42 mg/kg BW), and a low-dose (0.21 mg/kg BW). The control group was injected with sterile water into the muscles. Unusual changes caused by administration of the test substance were observed. Weight, feed intake, organ weight, and hematological examinations were compared among the groups. Using the SPSS statistical program, Levene's test was performed to evaluate the homogeneity of variances, and a one-way ANOVA test was subsequently performed to assess the significance between each test group. Results: During the experiment no animals died. Weight change, food consumption, organ weight, hematological test, and blood biochemical tests showed no significant differences in the treatment groups compared to controls. Conclusion: No toxicological changes related to the administration of test substances were observed. Therefore, the LD50 (lethal-dose that kills 50%) of scolopendrid pharmacoupuncture in rats was greater than 0.84 mg/kg.

A study on coagulant dosing process in water purification system (상수처리시스템의 응집제 주입공정 모델링에 관한 연구)

  • 남의석;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.317-320
    • /
    • 1997
  • In the water purification plant, chemicals are injected for quick purification of raw water. It is clear that the amount of chemicals intrinsically depends on the water quality such as turbidity, temperature, pH and alkalinity etc. However, the process of chemical reaction to improve water quality by the chemicals is not yet fully clarified nor quantified. The feedback signal in the process of coagulant dosage, which should be measured (through the sensor of the plant) to compute the appropriate amount of chemicals, is also not available. Most traditional methods focus on judging the conditions of purifying reaction and determine the amounts of chemicals through manual operation of field experts or jar-test results. This paper presents the method of deriving the optimum dosing rate of coagulant, PAC(Polymerized Aluminium Chloride) for coagulant dosing process in water purification system. A neural network model is developed for coagulant dosing and purifying process. The optimum coagulant dosing rate can be derived the neural network model. Conventionally, four input variables (turbidity, temperature, pH, alkalinity of raw water) are known to be related to the process, while considering the relationships to the reaction of coagulation and flocculation. Also, the turbidity in flocculator is regarded as a new input variable. And the genetic algorithm is utilized to identify the neural network structure. The ability of the proposed scheme validated through the field test is proved to be of considerable practical value.

  • PDF

Application of Ultra Rapid Coagulation for Securing Water Resource II: Study of organic, metals, and nutrients removal (수자원 확보를 위한 URC공법의 적용 I: 유기물, 중금속, 영양염의 제거특성에 관한 연구)

  • Park, Se Jin;Yoon, Tai Il;Kim, Jae Hyung;Cho, Kyung Chul
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.27-38
    • /
    • 2000
  • A physicochemical process called Ultra Rapid Coagulation(URC) can dramatically remove organics, metals, and phosphates in wastewater by adding weighted coagulation additive(WCA) and recycling sludge into the coagulation basin to increase the growth rate and adsorption ability of floc. Also this process can improve floc settling rate than conventional coagulation process and reduce the pollutants loaded into the receiving water for securing water source. It was evaluated that WCA and sludge added have effects on the removal efficiency and estimated the possibilities of reusing the effluent from this process.

  • PDF

Minimizing of Residual Aluminum in Water Treatment Process (정수처리공정에서 잔류 알루미늄 최소화 방안)

  • 이미영;조덕희;박종현
    • Proceedings of the Korean Sanitation Conference
    • /
    • 2004.11a
    • /
    • pp.54-65
    • /
    • 2004
  • Use of aluminum salts as coagulants In water treatment may lead to increased concentrations of aluminum in finished water. Aluminum is a suspected causative agent of neurological disorders such as Alzheimer's disease. The objective of this study was to examine variation and minimizing in residual aluminum concentration during water treatment process. The aluminum sources at Bokjeong Water Plant were present naturally aluminum in the raw water and derived due to use of PACS as a coagulant. Much of the raw water total aluminum were in particulate and suspended aluminum. In this study was compared the optimize condition to minimize the concentration of residual aluminum using Jar-test with the various coagulants such as alum, PAC, PACS. The results indicated that PACS was more effective than alum, PAC and insufficient or excessive alum, PAC, PACS addition led to increase residual aluminum. Adjustment raw water pH $6.5\~7.0$ before coagulation using PACS was capable of minimizing total and dissolved aluminum. Thus it is important that the optimal dosage of coagulant and the optimal pH adjustment before coagulation can decided to minimize the concentration of residual aluminum in treated water.

  • PDF

Spatial and Temporal Electrodynamics in Acuzones: Test-Induced Kinematics and Synchronous Structuring. Phenomenological Study

  • Babich, Yuri F.;Babich, Andrey Y.
    • Journal of Acupuncture Research
    • /
    • v.38 no.4
    • /
    • pp.300-311
    • /
    • 2021
  • Background: So far there is no confidence in the basics of acupoint/meridian phenomena, specifically in spatial and temporal electrical manifestations in the skin. Methods: Using the skin electrodynamic introscopy, the skin areas of 32 × 64 mm2 were monitored for spectral electrical impedance landscape with spatial resolution of 1 mm, at 2 kHz and 1 MHz frequencies. The detailed baseline and 2D test-induced 2 kHz-impedance phase dynamics and the 4-parameter time plots of dozens of individual points in the St32-34 regions were examined in a healthy participant and a patient with mild gastritis. Non-thermal stimuli were used: (1) (for the sick subject), microwaves and ultraviolet radiation applied alternately from opposite directions of the meridian; and (2) (for the healthy one) microwaves to St17, and cathodic/anodic stimulation of the outermost St45, alternately. Results: In both cases, the following phenomena have been observed: emergence of in-phase and/or antiphase coherent structures, exceeding the acupoint conditional size of 1 cm; collective movement along the meridian; reversible with a reversed stimulus; counter-directional dynamics of both whole structures and adjacent points; local abnormalities in sensitivity and dynamics of the 1 MHz and 2 kHz parameters indicating existence of different waveguide paths. Conclusion: It is assumed that these findings necessitate reconsideration of some basic methodological issues regarding neurogenic/acupuncture points as spatial and temporal phenomena; this requires development of an appropriate approach for identifying the acuzones patterns. These findings may be used for developing new approaches to personalized/controlled therapy/treatment.

Phosphorus Removal from Advanced Wastewater Treatment Process Using PAC (PAC를 이용한 하수의 고도처리공정에서의 인 제거)

  • Park, Wan-Cheol;Lee, Mi-Ae;Sung, Il-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.2
    • /
    • pp.96-102
    • /
    • 2014
  • To meet the reinforced discharge standards, effect of coagulant PAC (Poly aluminium chloride, 10.4% as $Al_2O_3$) on phosphorous removal in advanced wastewater treatment process (a modified $A^2$/O). 15 mg/L of PAC determined by jar-test was added to influent of settling basin in a modified $A^2$/O consists of anaerobic, anoxic, and oxic chamber which contains Bio-clod and porous polyurethane media. Performance of PAC was tested by supernatant after settling. The removal efficiencies of BOD, COD, TP (total phosphorus) and SP (soluble phosphorus) on biological process with PAC were 96.1%, 88.8%, 97.0% and 98.6%, compared with those on biological process without PAC were 95.4%, 72.4%, 71.6% and 59.5% respectively. 18.4% of TP and 39.1% of SP removal efficiency was increased, although increase of BOD and COD removal rate was not significant. Only PAC addition to influent of settling basin in $A^2O$ process can help total phosphorus removal to 0.13 mg/L with following discharge standard.

Urban Stormwater Runoff Treatment by the RFS (RFS를 이용한 도시유출수처리)

  • Lee, Jun-Ho;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.1
    • /
    • pp.159-167
    • /
    • 2000
  • In recent years, combined and separated sewer overflows (CSOs, SSOs) have been recognized as a significant pollution problem. To solve this problem a series of experiments were performed in a small scale Rapid Floc Settler (RFS) device to determine its ability in removing micro particles and dissolved materials from polluted waters. The RFS device is a compact physico-chemical wasterwater treatment system. Polyacrylamide (PAM) is used as a coagulant for treating stormwater in the RFS. The results of Jar test showed that PAM could be an excellent coagulant as compared with aluminum sulfate. and ferric chloride. In several experimental conditions, the influence of different variation parameters was tested to measure the efficiency of the RFS. Tests have been carried out with typical CSOs concentrations (50~1.000mg SS/L). The treatment efficiency with regard to SS and COD, which can be obtained at an overflow rate of $130m^3/m^2/day$, are 90% and 80%, respectively. Comparing other sedimentation technologies with RFS, the overflows rate of RFS is ten times faster. The distribution of particle size and number were analyzed. The RFS is suitable for the treatment of CSOs and also the removal of settleable and dissolved materials in urban stormwater runoff.

  • PDF

Treatment of Dredging Suspended Solids Using Chitosan Coagulant (Chitosan 응집제를 이용한 준설토 부유물질 처리)

  • Lee, Jun-Ho;Yang, Seung-Ho;Shin, Yiung-Kyewn;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.834-846
    • /
    • 2011
  • The objective of this study is to development of IDFIS system, that are consisted of hydrocyclone, rapid flocculation and inclined settler with chitosan coagulant. As the results of Jar test, a chitosan optimum dosage of 40 mg/L for river sediment, and 5 mg/L for tunnelling wastewater sediment, which these conditions leaves of residual turbidity of less than 5 NTU. Because of the effectiveness of chitosan in removing turbidity was independent on pH, the operation of IDFIS system would be simple. The synthesized turbidity was made with clay particles, river sediment, river suspended sediment, and tunnelling wastewater sediment. Results indicate that the mean overall removal efficiency of turbidity, SS, COD and TP were 98%, 99%, 85% and 95%, respectively. Chitosan is very efficient in removing turbidity in the entire turbidity range examined. IDFIS system would have possibility with compact design, because of the increase of floc size favours the floc settling speed and reduces the settling time.

The Evaluation of the Single-Dose Toxicity and Safety of 4-Carvomenthenol in ICR Mice

  • Yigun Lim;Jihoon Kong;Jiwon Lee;Gabsik Yang;Taehan Yook
    • Journal of Acupuncture Research
    • /
    • v.40 no.4
    • /
    • pp.344-350
    • /
    • 2023
  • Background: 4-carvomenthenol[4-methyl-1-(1-methylethyl)-3-cyclohexen-1-ol] is a main component of Origanum vulgare L., Zanthoxylum piperitum (L.) DC., and other plants. It has been reported to exhibit anti-inflammatory, antibacterial, and anti-tumor effects. Furthermore, it is necessary to conduct a toxicity test on 4-carvomenthenol to ensure its safety. Methods: This study included 5-week-old Institute of Cancer Research mice that were categorized into 3 treatment groups (12, 25, and 50 mg/kg 4-carvomenthenol dose levels) and a control group (10% dimethyl sulfoxide, 40% polyethylene glycol 300, 5% Tween 80, and 45% normal saline injection of the final volume), with 5 male mice and 5 female mice per group. All groups were observed for clinical symptoms and body weight in a period of 14 days and were subjected to gross necropsy after euthanasia. Results: No deaths were recorded. No test substance-related clinical signs in the female mice of the 12 mg/kg dose group were observed. Abnormal gait was observed in 1 male from day 1 to day 3 in the 12 mg/kg dose group; 1-3 males from day 1 to day 7 and 1-5 females from day 1 to day 15 in the 25 mg/kg dose group; and 2-5 males and 2-5 females from day 1 to day 15 in the 50 mg/kg dose group. No test substance-related effect on the body weight and necropsy findings was observed. Conclusion: The results of this study suggested that the lethal dose of 4-carvomenthenol could be greater than 50 mg/kg. However, further research is needed, especially repeated-dose toxicity studies, to confirm the efficacy and safety of 4-carvomenthenol.