• 제목/요약/키워드: Isothermal Cylinder

검색결과 22건 처리시간 0.016초

저온의 순수물속에 잠겨있는 등온수직 원기둥에 의한 자연대류 열전달에 종횡비가 미치는 영향 (Effects of aspect ratio on natural convective heat transfer from a vertical isothermal cylinder immersed in cold pure water)

  • 유갑종;엄용균;이성진
    • 대한기계학회논문집
    • /
    • 제15권2호
    • /
    • pp.677-684
    • /
    • 1991
  • A numerical analysis is performed about the effects of aspect ratio on natural convective heat transfer from a vertical isothermal cylinder of 0.deg. C immersed in cold pure water. The results of analysis include velocity profiles, temperature profiles and mean Nusselt number of the steady flow region. As aspect ratio of vertical cylinder increases, the flow and heat transfer characteristics of vertical isothermal cylinder approach to those of vertical isothermal flat plate. Numerical solutions obtained for Rayleigh number and aspect ratio indicate the cylinders can be classified as short cylinder and long cylinder. In the cases of short cylinder and long cylinder, new heat transfer correlations are presented. Here, the coefficient values C of new heat transfer correlations are presented as the function of density extremum parameter $R^*/. Numerical results show that theoretical results are in close agreement with experimental results.ts.

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • 유공압시스템학회논문집
    • /
    • 제5권1호
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF

맥동류에 놓인 등온 원통의 열전달 응답 (Heat Transfer Response of an Isothermal Cylinder to Fluctuating Cross Flow)

  • 권영필;이병호
    • 대한기계학회논문집
    • /
    • 제10권5호
    • /
    • pp.706-712
    • /
    • 1986
  • 본 연구는 맥동류의 진동 속도가 평균 유속에 비하여 매우 작은 경우로서 Re- ynolbs수가 40 이하 층류유동에 관한 것이다. 부력은 무시하고 비압축성의 점성유체 에 관한 비정상 Navier-Stokes 방정식과 에너지방정식의 선형 섭동방정식을 구하고, 진동성분의 복소진폭을 수치적으로 풀어서 저항력과 함께 열전달 응답의 진폭과 위상 을 구하였다.

음장이 등온원통으로부터의 강제대류 열전달에 미치는 영향 (Effect of Sound Field on the Forced Convection Heat Transfer from an Isothermal Cylinder)

  • 권영필
    • 대한기계학회논문집
    • /
    • 제12권2호
    • /
    • pp.373-380
    • /
    • 1988
  • 본 연구의 목적은 음장의 입자속도가 기류의 평균속도와 비슷한 크기인 경우에 원통으로부터 열전달의 동특성과 한 사이클의 평균값인 평균열전달이 음장에 의하여 어떠한 영향을 받는가를 구하기 위한 것이다.

최대밀도점 부근의 물 속에 잠겨있는 수직 등온 강선에 의한 자연대류 (Free Convection due to Vertical Isothermal Wires Immersed in Water near its Density Extremum)

  • 엄용균;유갑종
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.338-350
    • /
    • 1996
  • A numerical analysis is carried out to study the two-dimensional steady state natural convection from vertical wires immersed in cold pure water. The surface of the wire is $0^{\circ}C$ unifrom temperature. Results of the analysis are presented for free stream temperature from $0^{\circ}C$ to $25^{\circ}C$ and the aspect ratio N from $5.26{\times}10^{-3}$ to $1.0{\times}10^{-3}$. The effects of the density extremum and aspect ratio on the flow pattern and the heat transfer characteristics are discussed As the aspect ratio N becomes larger, in the range of $1.0^{\circ}C{\leq}T_{\infty}{\leq}4.4^{\circ}C$ and $6{^{\circ}C}{\leq}T_{\infty}{\leq}17^{\circ}C$, the effect of Pr number on the heat transfer is shown to be more significant than the aspect ratio. Investigating into the effect of the density extremum on the heat transfer from wires, the new heat transfer correlations are suggested with the relation of average Nu mumber vs. modified Ra number. Here, the coefficient values C of correlations are presented as the function of density extremum parameter $R^*$. The effects of the density extremum parameter are also discussed.

  • PDF

회전하고 있는 바깥쪽 실린더를 갖고 있는 수평 원주형 환형 내에서의 공기의 혼합 대류 (Mixed convection of air in a horizontal cylindrical annulus with rotating outer cylinder)

  • 유주식
    • 대한기계학회논문집B
    • /
    • 제21권4호
    • /
    • pp.551-561
    • /
    • 1997
  • Mixed convection of air in a horizontal concentric cylindrical annulus is investigated numerically. Isothermal boundary conditions are prescribed at the inner and outer cylinders, with the inner cylinder being warmer. The forced flow is induced by the outer cylinder which is rotating slowly with constant angular velocity with its axis at the center of the annulus. The effect of the forced flow on the flow pattern and heat transfer of natural convection is investigated for the annulus of (inner-cylinder radius/gap width) = 1. There appear two eddies, one eddy or no eddy according to the Rayleigh and Reynolds numbers. Map of the three flow regimes is constructed on the Ra-Re plane. (author). 28 refs., 9 figs., 2 tabs.

비등온 실린더 모델을 이용한 태양로의 강제 대류에 의한 열 손실 분석 (Forced Convection Modelling of a Solar Central Receiver using Nonisothermal Cylinders in Crossflow)

  • 천원기;전명석;전홍석;오정무;로버트벰
    • 태양에너지
    • /
    • 제10권3호
    • /
    • pp.13-18
    • /
    • 1990
  • 표면 온도가 균일하지 않은 원통을 균속도 유동장에 가로 놓았을 경우, 표면에서의 열전달 특성은 표면이 등온이거나 일정한 heat flux가 주어졌을 때와는 판이하게 다르다. 본 연구에서는 공기의 균속도 유동장내에서 두가지 경우(step형 및 선형변화)의 비등은 경제조건이 원통면을 따라 원주방향으로 주어졌을 때 표면에서의 열전달 특성을 고찰하였다. Step형 변화는 원통형 태양로의 표면에서 관찰될 수 있다. Solar One(Califomia주의 Barstow시에 있는 태양로)의 경우, 작동유체(물)는 표면을 따라 원주방향과 수직으로 설치된 튜브를 따라 흐르면서 액체상태로부터 고온고압의 증기로 변한다. 이 과정에서 태양로 표면의 receiver panel은 그 위치에 따라, preheater, boiler, 그리고 superheater의 역할을 수행하며 표면의 온도도 균일하지 않은 분포를 나타낸다. 이와 같은 경우 표면의 평균 온도를 가지고 대류에 의한 열 손실을 계산하면 큰 오류를 범할 가능성이 있다.

  • PDF

저온인 순수물 속의 등온 수직얼음 원기둥에 의해 야기되는 자연대류의 실험적 연구 (Experimental Study of Natural Convection Adjacent to an Isothermal Vertical Ice Cylinder in Cold Pure Water)

  • 유갑종;예용택;박상희
    • 대한기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.1737-1746
    • /
    • 1991
  • 본 연구에서는 저온의 순수물 속의 등온 수직원기둥에 의해 야기되는 열전달 특성을 구명함에 있어서 짧은 원기둥 범주에 속하는 종횡비 0.5인 얼음 원기둥을 이용 하여 실험적으로 열전달 특성을 구명하였다. 그리고 전 유동장을 가시화 하였으며, 얼음의 융해율로써 누셀트(Nusselt)수를 측정하여 기존의 결과들과 비교검토하였다.

공기압실린더의 누설유량 계측에 관한 연구 (A Study on the Measurement Method of Leakage for Pneumatic Cylinder)

  • 장지성;지상원
    • 동력기계공학회지
    • /
    • 제11권4호
    • /
    • pp.98-102
    • /
    • 2007
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measured from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing the steel wool into it. Therefore, a wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

공압실린더의 누설유량 계측방법에 관한 연구 (A Study on the Measurement Method of Leakage Flow-rate for Pneumatic Cylinder)

  • 장지성;지상원;정지현;강보식
    • 유공압시스템학회논문집
    • /
    • 제3권1호
    • /
    • pp.15-19
    • /
    • 2006
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measure from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF