Effects of aspect ratio on natural convective heat transfer from a vertical isothermal cylinder immersed in cold pure water (저온의 순수물속에 잠겨있는 등온수직 원기둥에 의한 자연대류 열전달에 종횡비가 미치는 영향)

  • 유갑종;엄용균;이성진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.677-684
    • /
    • 1991
  • A numerical analysis is performed about the effects of aspect ratio on natural convective heat transfer from a vertical isothermal cylinder of 0.deg. C immersed in cold pure water. The results of analysis include velocity profiles, temperature profiles and mean Nusselt number of the steady flow region. As aspect ratio of vertical cylinder increases, the flow and heat transfer characteristics of vertical isothermal cylinder approach to those of vertical isothermal flat plate. Numerical solutions obtained for Rayleigh number and aspect ratio indicate the cylinders can be classified as short cylinder and long cylinder. In the cases of short cylinder and long cylinder, new heat transfer correlations are presented. Here, the coefficient values C of new heat transfer correlations are presented as the function of density extremum parameter $R^*/. Numerical results show that theoretical results are in close agreement with experimental results.ts.

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF

Heat Transfer Response of an Isothermal Cylinder to Fluctuating Cross Flow (맥동류에 놓인 등온 원통의 열전달 응답)

  • 권영필;이병호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.706-712
    • /
    • 1986
  • The unsteay heat transfer from an isothermal circular cylinder in fluctuating cross flow is simulated numerically, for the case where the amplitude of the oscillating velocity is small compared with the mean velocity. By solving the linear perturbation equations derived from the unsteady full Navier-Stokes and the energy equations, the amplitude and the phase of heat transfer response are obtained in the range of Reynolds number R$_{3}$ < 40. The effects of the velocity, the cylinder radius and the frequency on the response are expressed graphically in terms of the normalized velocity and the cylinder radius.

Effect of Sound Field on the Forced Convection Heat Transfer from an Isothermal Cylinder (음장이 등온원통으로부터의 강제대류 열전달에 미치는 영향)

  • 권영필
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.373-380
    • /
    • 1988
  • The effect of sound on the heat transfer from an isothermal cylinder in cross flow is investigated by numerical analysis. The modeling is made for the laminar incompressible flow fluctuating in the range of the Reynolds number, 5.leq.Re.leq.35, by the sinusoidal acoustic field. The instantaneous response of the flow and heat transfer is simulated for various frequencies. It is shown that the heat transfer amplitude decreases and the phase lags behind the flow velocity with increase in the frequency. The time-mean effects of the acoustic field on the flow field and heat transfer, known as the acoustic and thermoacoustic streaming, are analyzed. The time-mean heat transfer coefficients are decreased around the forward stagnation point but increased in the wake region. Such a local difference in heat transfer coefficients is a function of the frequency and becomes greatest at some frequency. However, with balance between the local increase and decrease, the overall heat transfer coefficient is almost unaffected by sound.

Free Convection due to Vertical Isothermal Wires Immersed in Water near its Density Extremum (최대밀도점 부근의 물 속에 잠겨있는 수직 등온 강선에 의한 자연대류)

  • Eom, Y.K.;Riu, K.J.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.338-350
    • /
    • 1996
  • A numerical analysis is carried out to study the two-dimensional steady state natural convection from vertical wires immersed in cold pure water. The surface of the wire is $0^{\circ}C$ unifrom temperature. Results of the analysis are presented for free stream temperature from $0^{\circ}C$ to $25^{\circ}C$ and the aspect ratio N from $5.26{\times}10^{-3}$ to $1.0{\times}10^{-3}$. The effects of the density extremum and aspect ratio on the flow pattern and the heat transfer characteristics are discussed As the aspect ratio N becomes larger, in the range of $1.0^{\circ}C{\leq}T_{\infty}{\leq}4.4^{\circ}C$ and $6{^{\circ}C}{\leq}T_{\infty}{\leq}17^{\circ}C$, the effect of Pr number on the heat transfer is shown to be more significant than the aspect ratio. Investigating into the effect of the density extremum on the heat transfer from wires, the new heat transfer correlations are suggested with the relation of average Nu mumber vs. modified Ra number. Here, the coefficient values C of correlations are presented as the function of density extremum parameter $R^*$. The effects of the density extremum parameter are also discussed.

  • PDF

Mixed convection of air in a horizontal cylindrical annulus with rotating outer cylinder (회전하고 있는 바깥쪽 실린더를 갖고 있는 수평 원주형 환형 내에서의 공기의 혼합 대류)

  • Yu, Ju-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.4
    • /
    • pp.551-561
    • /
    • 1997
  • Mixed convection of air in a horizontal concentric cylindrical annulus is investigated numerically. Isothermal boundary conditions are prescribed at the inner and outer cylinders, with the inner cylinder being warmer. The forced flow is induced by the outer cylinder which is rotating slowly with constant angular velocity with its axis at the center of the annulus. The effect of the forced flow on the flow pattern and heat transfer of natural convection is investigated for the annulus of (inner-cylinder radius/gap width) = 1. There appear two eddies, one eddy or no eddy according to the Rayleigh and Reynolds numbers. Map of the three flow regimes is constructed on the Ra-Re plane. (author). 28 refs., 9 figs., 2 tabs.

Forced Convection Modelling of a Solar Central Receiver using Nonisothermal Cylinders in Crossflow (비등온 실린더 모델을 이용한 태양로의 강제 대류에 의한 열 손실 분석)

  • Chun, Won-Gee;Jeon, Myung-Seok;Jeon, Hong-Seok;Auh, P. Chung-Moo;Boehn, Robert F.
    • Solar Energy
    • /
    • v.10 no.3
    • /
    • pp.13-18
    • /
    • 1990
  • When nonuniform thermal boundary conditions are imposed on the surface of a circular cylinder in crossflow, the heat transfer characteristics can be quite different compared to what is found for isothermal or constant heat flux boundary conditions. In the present analysis, two kinds of nonuniform boundary conditions along the circumference of the cylinder are considered in a uniform stream of air: step changes and linear profiles. Step changes in temperature can arise on the surface of an external, cylindrical, solar central receiver. As the working fluid(water) flows through the vertical tubes that ring the circumference of Solar One(a solar central receiver in Barstow, California), the solar flux on the receiver heats the water from a liquid to a superheated state. In this process, portions of the receiver panels, and thus portions of the circumference of the cylinder, function as a preheater, boiler, or superheater. Hence the surface temperature can vary significantly around the cylinder. Common engineering practice has been to use an average wall temperature with an isothermal cylinder heat transfer coefficient when estimating the convective loss in these kinds of situations.

  • PDF

Experimental Study of Natural Convection Adjacent to an Isothermal Vertical Ice Cylinder in Cold Pure Water (저온인 순수물 속의 등온 수직얼음 원기둥에 의해 야기되는 자연대류의 실험적 연구)

  • 유갑종;예용택;박상희
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.5
    • /
    • pp.1737-1746
    • /
    • 1991
  • 본 연구에서는 저온의 순수물 속의 등온 수직원기둥에 의해 야기되는 열전달 특성을 구명함에 있어서 짧은 원기둥 범주에 속하는 종횡비 0.5인 얼음 원기둥을 이용 하여 실험적으로 열전달 특성을 구명하였다. 그리고 전 유동장을 가시화 하였으며, 얼음의 융해율로써 누셀트(Nusselt)수를 측정하여 기존의 결과들과 비교검토하였다.

A Study on the Measurement Method of Leakage for Pneumatic Cylinder (공기압실린더의 누설유량 계측에 관한 연구)

  • Jang, J.S.;Ji, S.W.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.98-102
    • /
    • 2007
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measured from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing the steel wool into it. Therefore, a wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

A Study on the Measurement Method of Leakage Flow-rate for Pneumatic Cylinder (공압실린더의 누설유량 계측방법에 관한 연구)

  • Jang J.S.;Ji S.W.;Jeong J.H.;Kang B.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.1
    • /
    • pp.15-19
    • /
    • 2006
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measure from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF