• 제목/요약/키워드: Isolation plate

검색결과 173건 처리시간 0.035초

내진시험을 통한 IRB 시스템의 성능 평가 (Performance Evaluation of IRB System Using Seismic Isolation Test)

  • 박영기;하성훈;우제관;최승복;김현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.401-406
    • /
    • 2013
  • This paper presents experimental evaluation of IRE (isolation roller bearing) seismic isolation device. From the combination of base isolation on the IRE system displacement response spectrum and acceleration response spectrum, the compressive strength and the coefficient of friction experiments. Also the IRE system is evaluated by environment test according to KS standards. Both the resonance and seismic experiments using a combination of the IRE and Natural Rubber Bearing (NRB) are performed in order to analyze the seismic isolation of the IRE system dynamic characteristics. For the given load and exciting frequency, the resonant frequency becomes lower, but the resonant magnification remains to be same. However, it is shown that when we consider the IRE only, the vibration on the table with the horizontal movement and the independent horizontal displacement due to the rolling motion of the plate and roller are significantly reduced. This result verifies that the proposed optimal design method of the IRE system is very effective.

  • PDF

멀티 오리피스를 이용한 에어스프링 동특성 개선에 관한 연구 (The Study on the improvement of dynamic characteristics with multi-orifice in airspring)

  • 김인수;황성호;한문성;고철수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.97-103
    • /
    • 2002
  • Vibration isolation technology using an air spring and laminated rubber bearing is widely used because it has excellent vibration isolation characteristics. In the part of that, we usually make use of the self-damped air suing. It is occupied two chambers, restrictor, diaphragm and load plate. Two chambers contain compressed air and the volume of chambers and the area of load plate give a definition of stiffness and load. The restrictor and the volume ratio of two chambers give a definition of damping ratio. The conventional model of restrictor is made of one orifice and it causes turbulent flow in the orifice at the region of large deflection. The stillness of air suing is larger and the damping is lower in the region of large deflection. In the multi-orifice case, the stiffness is similar to air spring with one orifice but damping ratio is larger than conventional air spring. And damping ratio is smaller than conventional air suing in small deflection region. Deflection is small in the region of high frequency so small damping is better than large damping. As a result, we can reduce the storage stiffness of air suing in the wide region of deflection and increase the damping ratio in the region of large deflection. After this, we will try to and the relation of Reynolds Number and Flow Resistance then we are going to make another restrictor for air spring to improve damping ratio and stiffness.

  • PDF

전자빔건 헤드유니트의 설계와 제작 (Establishment of Gun Head Unit for Electron Beam Machining System)

  • 강재훈;이찬홍;최종호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1875-1878
    • /
    • 2005
  • It is not efficient and scarcely out of the question to use commercial expensive electron beam lithography system widely used for semiconductor fabrication process for the manufacturing application field of various devices in the small business scope. Then scanning electron microscope based electron beam machining system is maybe regarded as a powerful model can be used for it simply. To get a complete suite of thus proper system, column unit build up with electron beam gun head unit is necessarily required more than anything else to modify scanning electron microscope. In this study, various components included ceramic isolation plate and main body which are essentially constructed for electron beam gun head unit are designed and manufactured. And this electron beam gun head unit will be used for next connected study in the development step of scanning electron microscope based electron beam machining system.

  • PDF

미세 간극 수직 콤을 이용한 저 전압 고 격리도 단결정 RF MEMS 스위치 (Low-voltage high-isolation RF MEMS switch based on a single crystalline silicon structure with fine gap vertical comb)

  • 문성수;김현철;전국진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.953-956
    • /
    • 2005
  • Low voltage actuation and high isolation characteristics are key features to be solved in electrostatic RF switch design. Since these parameters in the conventional parallel plate MEMS switch design are in trade-off relation, both requirements cannot be met simultaneously. In vertical comb design, however, the actuation voltage is independent to the vertical separation distance between the contact electrodes. Then, we can design the large separation distance between contact electrodes to get high isolation. We have designed an RF MEMS switch which has -40dB isolation at 5 GHz and 6 V operation voltages. The characteristics of the fabricated switch are being evaluate.

  • PDF

See-saw Type RF MEMS Switch with Narrow Gap Vertical Comb

  • Kang, Sung-Chan;Moon, Sung-Soo;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권3호
    • /
    • pp.177-182
    • /
    • 2007
  • This paper presents the see-saw type RF MEMS switch based on a single crystalline silicon structure with narrow gap vertical comb. Low actuation voltage and high isolation are key features to be solved in electrostatic RF MEMS switch design. Since these parameters in conventional parallel plate RF MEMS switch designs are in trade-off relationship, both requirements cannot be met simultaneously. In the vertical comb design, however, the actuation voltage is independent of the vertical separation distance between the contact electrodes. Therefore, the large separation gap between contact electrodes is implemented to achieve high isolation. We have designed and fabricated RF MEMS switch which has 46dB isolation at 5GHz, 0.9dB insertion loss at 5GHz and 40V actuation voltage.

128${\times}$144 pixel array 지문인식센서 설계 (Design of a Fingerprint Authentication Sensor with 128${\times}$144 pixel array)

  • 정승민;김정태;이문기
    • 한국정보통신학회논문지
    • /
    • 제7권6호
    • /
    • pp.1297-1303
    • /
    • 2003
  • 반도체 방식의 capacitive type 지문인식센서의 신호처리를 위한 개선된 회로를 설계하였다. 최 상위 sensor plate가 지문의 굴곡을 감지한 capacitance의 변화를 전압의 신호로 전환하기위해서 charge-sharing 방식의 회로를 적용하였다. 지문센서 감도저하의 가장 큰 원인인 sensor plate에 존재하는 parasitic capacitance를 최소화하고 ridge와 valley 사이의 전압차를 향상시키기 위하여 기존과는 다른 아날로그버퍼회로를 설계하였다. 센서전압과 기준전압 신호를 비교하기 위해서 비교기를 설계하였으며, 센서어레이의 수직, 수평간 isolation 대책을 통하여 ESD 및 노이즈방지를 위한 설계를 제안하였다. 제안된 신호처리회로는 128${\times}$l44 pixel 규모의 회로로 구현되었다. 본 설계회로는 향후 생체인식을 이용한 정보보호용 지문인식 시스템에 응용될 수 있으리라본다.

Rapid Screen for Bacteria Solubilzing Insoluble Phoshpate on Agar Plate

  • Son, Hong-Joo;Kang, Sung-Il;Kim, Yong-Gyun;Kim, Hee-Goo;Lee, Sang-Joon
    • Journal of Life Science
    • /
    • 제10권1호
    • /
    • pp.64-65
    • /
    • 2000
  • Insoluble phosphate-solubilizing bacteria are routinely screened by a plate assay method using Pikovskaya agar and a modified Pikovskaya medium. A modified Pikovskaya medium to improve the clarity of the yellow-colored halo has not necessarity improved the plate assay. Colonies of phosphate-solubilizing bacteria tested could be redily selected after 48 h of incubation by green-colored colony formation on plate in which bromcresol green(BCG) was included. Among them, two bacterial strains did not produce distinct yellow halos after 48 h of incubation. We suggest that the green colony formation on plate medium containing BCG is advantageous ofr rapid isolating phosphate-solubilizing bacteria directly from soil.

Vibration mode decomposition response analysis of large floating roof tank isolation considering swing effect

  • Sun, Jiangang;Cui, Lifu;Li, Xiang;Wang, Zhen;Liu, Weibing;Lv, Yuan
    • Earthquakes and Structures
    • /
    • 제15권4호
    • /
    • pp.411-417
    • /
    • 2018
  • To solve the seismic response problem of a vertical floating roof tank with base isolation, the floating roof is assumed to experience homogeneous rigid circular plate vibration, where the wave height of the vibration is linearly distributed along the radius, starting from the theory of fluid velocity potential; the potential function of the liquid movement and the corresponding theoretical expression of the base shear, overturning the moment, are then established. According to the equivalent principle of the shear and moment, a simplified mechanical model of a base isolation tank with a swinging effect is established, along with a motion equation of a vertical storage tank isolation system that considers the swinging effect based on the energy principle. At the same time, taking a 150,000 m 3 large-scale storage tank as an example, a numerical analysis of the dampening effect was conducted using a vibration mode decomposition response spectrum method, and a comparative analysis with a simplified mechanical model with no swinging effect was applied.

LRB 댐퍼 조합형 지진격리장치 개발 및 특성평가실험 (Development of Seismic Isolation Device with LRB and Shock Transmission Units and Its Verification Tests)

  • 서주원;김남식;임진석;유문식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.383-390
    • /
    • 2002
  • The new seismic isolation system (StLRB) is developed, which can separate non-seismic displacements which come from the thermal expansion etc. in LRB design. The StLRB has 3 components, sliding system (PTFE + stainless plate), LRB (lead rubber bearing) and STU (shock transmit units). In this project, the StLRB is designed to apply to the bridge structure by analyzing the characteristics of each component and also the dynamic behavior of the structure was analyzed by non-linear analysis. The verification test was performed to show the two stages separated by STU units. Test results show the effectiveness of both the separation and the seismic isolation performance.

  • PDF

압전세라믹을 이용한 능동진동제어장치의 개발 (Development of the Active Vibration Absorber Using Piezoelectric Actuators)

  • 곽명훈;허석;곽문규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.476-481
    • /
    • 2001
  • This research is concerned with development of the active vibration absorber using piezoelectric actuators. This active isolation system consists of a-pairs of PZT actuators bonded on a S-shaped aluminum plate and the passive damping material. The active system is connected to the passive system in series. In this paper, one of the popular control techniques which have been successfully applied to the smart structure is the Positive Position Feedback(PPF) control. The digital PPF control lows downloaded to the DSP chip and a main program, which runs SISO PPF algorithm. The structure and dynamic characteristics of the proposed active vibration isolation system and described in detail. To demonstate the effectiveness of the active vibration control, the PPF controller is first employed. Experimental results show that the active vibration isolation is possible by means of the proposed system.

  • PDF