• Title/Summary/Keyword: Isolation network

Search Result 239, Processing Time 0.028 seconds

Design of Observer-Based Fault Detection and Isolation techniques for Induction Motors (유도전동기를 위한 관측기 기반의 고장 감지 및 분리 기법 설계)

  • Han, Byung-Jo;Park, Gi-Kwang;Koo, Kyung-Wan;Yang, Hai-Won
    • Proceedings of the KIEE Conference
    • /
    • 2009.04a
    • /
    • pp.77-79
    • /
    • 2009
  • Nonlinear system fault detection and isolation of this paper is about the failure of unknown function approximation using neural network for fault detection and isolation techniques of induction motors were applied. observer-based fault signal residual value was used. Induction motor using the speed controller of the backstepping controller. Proposed fault detection and isolation to prove the performance of the simulation was applied to and the actual system.

  • PDF

Model-based fault detection and isolation of a linear system (선형시스템의 모델기반 고장감지와 분류)

  • 이인수;전기준
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.1
    • /
    • pp.68-79
    • /
    • 1998
  • In this paper, we propose a model-based FDI(fault detetion and isolation) algorithm to detect and isolate fault in a linear system. The proposed algorithm is gased on an HFC(hydrid fault classifier) which consists of an FCART2(fault classifier by ART2 neural network) and an FCFM(fault classifier by fault models) which operate in parallel to isolate faults. The proposed algorithm is functionally composed of three main parts-parameter estimation, fault detection, and isolation. When a change in the system occurs, the estimated parameters go through a transition zone in which errors between the system output and the stimated output and the estimated output cross a predetermined thrseshold, and in this zone the estimated parameters are tranferred to the FCART2 for fault isolation. On the other hand, once a fault in the system is detected, the FCFM statistically isolates the fault by using the error between ach fault model out put and the system output. From the computer simulation resutls, it is verified that the proposed model-based FDI algorithm can be performed successfully to detect and isolate faults in a position control system of a DC motor.

  • PDF

A Study on the Intrusion Detection Method using Firewall Log (방화벽 로그를 이용한 침입탐지기법 연구)

  • Yoon, Sung-Jong;Kim, Jeong-Ho
    • Journal of Information Technology Applications and Management
    • /
    • v.13 no.4
    • /
    • pp.141-153
    • /
    • 2006
  • According to supply of super high way internet service, importance of security becomes more emphasizing. Therefore, flawless security solution is needed for blocking information outflow when we send or receive data. large enterprise and public organizations can react to this problem, however, small organization with limited work force and capital can't. Therefore they need to elevate their level of information security by improving their information security system without additional money. No hackings can be done without passing invasion blocking system which installed at the very front of network. Therefore, if we manage.isolation log effective, we can recognize hacking trial at the step of pre-detection. In this paper, it supports information security manager to execute isolation log analysis very effectively. It also provides isolation log analysis module which notifies hacking attack by analyzing isolation log.

  • PDF

Fault Diagnosis of the Nonlinear Systems Using Neural Network-Based Multi-Fault Models (신경회로망기반 다중고장모델에 의한 비선형시스템의 고장진단)

  • 이인수
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.115-118
    • /
    • 2001
  • In this paper we propose an FDI(fault detection and isolation) algorithm using neural network-based multi-fault models to detect and isolate single faults in nonlinear systems. When a change in the system occurs, the errors between the system output and the neural network nominal system output cross a threshold, and once a fault in the system is detected, the fault classifier statistically isolates the fault by using the error between each neural network-based fault model output and the system output.

  • PDF

(Efficient Fault Diagnosis of Stuck-at-Faults in Multistage Interconnection Networks) (다단계 상호연결망의 고착고장에 대한 효율적인 고장진단 기법)

  • Kim, Yeong-Jae;Jo, Gwang-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.1
    • /
    • pp.24-32
    • /
    • 2002
  • This paper is concerned with the fault diagnosis for stuck-at faults of a multistage interconnection network(MIM) which is a kind of interconnection networks in multicomputer systems. Up to the present, a fault diagnosis scheme has dealt with a fault model of all types, which results in complicated algorithms. In the literature, it is shown that a number of steps and computation are required for the fault detection and isolation algorithms for a class of MINs. In this paper, we propose a simple and easily implementable algorithm for the detection and isolation of the stuck-at fault in MIM. specifically, we develope an at algorithm for the isolation of the source fault in switching elements whenever tile stuck-at fault is detected in MINs. After all, the proposed algorithm is illustrated by an example of 16$\times$16 baseline networks of MINs.

An Analysis of Green Space Base for Networking in Daegu Metropolitan Municipality (녹지연계망 조성을 위한 거점 분석 -대구광역시의 사례 -)

  • 나정화;사공정희
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.29 no.6
    • /
    • pp.37-49
    • /
    • 2002
  • The objective of this research was an investigation of the important green spaces in Daegu and to present the basic frame of green network in Daegu. Present the condition of the significant green spaces is as follows: In the 3km radius of the city center, the isolation and discontinuation of the green spaces was extensive, caused by crowding of houses and funeral parlours. Consequently, the isolation relaxation which leads to the additional creation of the green spaces and a buffering plan were demanded. In the transfer area of a 3∼6km radius, which is located between the city center's congested area and the suburb green spaces, the significant green spaces had high connection and buffering characteristic, but in the northwest and the south, serious discontinuation appeared between the suburb green spaces and the city conte green spaces. In the 6∼9km radius, the suburb important green spaces accomplished the function which extended the back core green spaces to the city center area. But creation of buffering green spaces was necessary in part because of proximity to the resident area. The results suggest a connection between green spaces on the base of the distribution of the important green spaces, were as follows: In the 3km radius, irregular direction lines appeared while a schedule one direction line appeared in 3∼6km and 6∼9km radius. The discontinued parts of the green network were caused by industrial complexes, house crowding, and cultivation areas. Consequently, reservation and creation plans of green spaces in response to this were demanded. Through the additional creation of green spaces in the discontinued parts, the basic frame of green network in Daegu was the radiation annular form. And it was suitable to activate the parks and the general green spaces.

Patient Management to Improve the Efficiency of Infectious U-MAS System Design (전염성 환자관리의 효율성을 개선하기 위한 U-MAS 시스템 설계)

  • Shin, Yoon-Hwan;Shin, Ye-Ho;Ryu, Keun-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.9
    • /
    • pp.75-84
    • /
    • 2009
  • In this paper, the EPC Network as the most important technologies in the field of applied technology research and special attention to the use of RFID to better manage the disease in infected U-MAS (U-Medical Administrative Services) system was designed. U-MAS system, the Center for Disease Control in the illness, depending on the type of isolate and treat infected patients, recovery, discharge, isolation wards and intensive italian to manage and increase efficiency, manual and use a simple computer program improve the qualify of the current level, using RFID tags to improve the management of the patient everything that a little more and be out of the isolation ward, if competent disease management districts, such as the location to respond more quickly to facilitate the purpose is to contribute to. First, EPC Network and related technology for mobile RFID systems and related technology research. U-MAS system design offers. If you take advantage of the proposed U-MAS system for monitoring infectious disease patients and patients in the isolation ward, when the unauthorized departure location to shorten the time it takes to improve the effectiveness of disease management and present the elected effects was.

(Fault Detection and Isolation of the Nonlinear systems Using Neural Network-Based Multi-Fault Models) (신경회로망기반 다중고장모델에 의한 비선형시스템의 고장감지와 분류)

  • Lee, In-Su
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.1
    • /
    • pp.42-50
    • /
    • 2002
  • In this paper, we propose an FDI(fault detection and isolation) method using neural network-based multi-fault models to detect and isolate faults in nonlinear systems. When a change in the system occurs, the errors between the system output and the neural network nominal system output cross a threshold, and once a fault in the system is detected, the fault classifier statistically isolates the fault by using the error between each neural network-based fault model output and the system output. From the computer simulation results, it is verified that the proposed fault diagonal method can be performed successfully to detect and isolate faults in a nonlinear system.

An Eight-Element Compact Low-Profile Planar MIMO Antenna Using LC Resonance with High Isolation

  • Kwon, DukSoo;Lee, Soo-Ji;Kim, Jin-Woo;Ahn, ByungKuon;Yu, Jong-Won;Lee, Wang-Sang
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.3
    • /
    • pp.194-197
    • /
    • 2016
  • An eight-element compact low-profile multi-input multi-output (MIMO) antenna is proposed for wireless local area network (WLAN) mobile applications. The proposed antenna consists of eight inverted-F antennas with an isolation-enhanced structure. By inserting the isolation-enhanced structure between the antenna elements, the slot and capacitor pair generates additional resonant frequency and decreases mutual coupling between the antenna elements. The overall size of the proposed antenna is only $33mm{\times}33mm$, which is integrated into an area of just $0.5{\lambda}{\times}0.5{\lambda}$. The proposed antenna meets 5-GHz WLAN standards with an operation bandwidth of 4.86 - 5.27 GHz and achieves an isolation of approximately 30 dB at 5 GHz. The simulated and measured results for the proposed antenna are presented and compared.

An Algorithm for Searching On-Off Valves to Isolate a Subsystem in a Water Distribution System (상수관망의 부분적 격리를 위한 제수밸브 탐색 알고리듬)

  • Jun, Hwan Don;Kim, Joong Hoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.35-43
    • /
    • 2006
  • Concerns related to protecting, identifying, and isolating of subsystems of a water distribution network have led to the realization of the increased importance of valves in the system. The most important purpose of valves in water distribution systems is to isolate a subsystem due to breakage, maintenance activities, or contamination. A subsystem called segment is isolated by the closure of adjacent valves. Minimizing the pipe failure impact, an efficient algorithm is required to identify adjacent valves quickly. In this paper, an algorithm to identify adjacent valves to be closed to isolate a subsystem from the remainder of a network when a pipe failure is presented. The algorithm is operated on a matrix called the valve location matrix containing the information of valve locations. An application to an existing water distribution system demonstrates the developed algorithm efficiently locates the adjacent valves for the isolation of a broken pipe.