• Title/Summary/Keyword: Isolation Technique

Search Result 387, Processing Time 0.027 seconds

Enhanced OLSR for Defense against DOS Attack in Ad Hoc Networks

  • Marimuthu, Mohanapriya;Krishnamurthi, Ilango
    • Journal of Communications and Networks
    • /
    • v.15 no.1
    • /
    • pp.31-37
    • /
    • 2013
  • Mobile ad hoc networks (MANET) refers to a network designed for special applications for which it is difficult to use a backbone network. In MANETs, applications are mostly involved with sensitive and secret information. Since MANET assumes a trusted environment for routing, security is a major issue. In this paper we analyze the vulnerabilities of a pro-active routing protocol called optimized link state routing (OLSR) against a specific type of denial-of-service (DOS) attack called node isolation attack. Analyzing the attack, we propose a mechanism called enhanced OLSR (EOLSR) protocol which is a trust based technique to secure the OLSR nodes against the attack. Our technique is capable of finding whether a node is advertising correct topology information or not by verifying its Hello packets, thus detecting node isolation attacks. The experiment results show that our protocol is able to achieve routing security with 45% increase in packet delivery ratio and 44% reduction in packet loss rate when compared to standard OLSR under node isolation attack. Our technique is light weight because it doesn't involve high computational complexity for securing the network.

Control Performance Evaluation of Mid-Story Isolation System for Residence-Commerce Complex Building (주상 복합 구조물에 적용된 중간층 면진 시스템의 성능 검토)

  • Park, Kwang-Seob;Kim, Yun-Tae;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.19 no.3
    • /
    • pp.33-40
    • /
    • 2019
  • A seismic isolation system is one of the most effective control devices used for mitigating the structural responses due to earthquake loads. This system is generally used as a type of base isolation system for low- and mid-rise building structures. If the base isolation technique is applied to high-rise buildings, a lot of problems may be induced such as the movement of isolation bearings during severe wind loads, the stability problem of bearings under large compression forces. Therefore, a mid-story isolation system was proposed for seismic protection of high-rise buildings. Residence-commerce complex buildings in Korea have vertical irregularity because shear wall type and frame type structures are vertically connected. This problem can be also solved by the mid-story isolation system. An effective analytical method using super elements and substructures was proposed in this study. This method was used to investigate control performance of mid-story isolation system for residence-commerce complex buildings subjected to seismic loads. Based on numerical analyses, it was shown that the mid-story isolation system can effectively reduce seismic responses of residence-commerce complex tall buildings.

Development of the Optimal Design Technique for the Pneumatic Vibration Isolation System by Nonlinear Modeling and Analysis (공압방진시스템의 비선형 모델링과 해석을 통한 최적설계기술 개발)

  • 문준희;박희재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.151-154
    • /
    • 2001
  • The pneumatic vibration isolation systems have been widely used in industry and laboratories, but the full mathematical analysis and nonlinear modeling techniques have not been reported yet, even while the nonlinear features of the pneumatic vibration isolation system decide the main characteristics. For instance, the orifice in a pneumatic vibration isolator has been traditionally considered as a simple viscous damper, which was too much simplified to explain the performance of the isolation system. In this paper, the nonlinear characteristics are considered for the orifice and chamber, etc. The numerical simulation is carried out by the MATLAB/Simulink software. From the analysis result, a clear trend of the nonlinear features is shown: the vibration transmissibility changes not only due to the excitation frequency but also due to the amplitude of the vibration excitation. Therefore various design parameters are optimally chosen for the vibration isolation system. The proposed methods show good compatibility between the analysis results and the experiments.

  • PDF

Identification of a Technique Optimized for the Isolation of Spermatogonial Stem Cells from Mouse Testes

  • Han, Na Rae;Park, Hye Jin;Lee, Hyun;Yun, Jung Im;Choi, Kimyung;Lee, Eunsong;Lee, Seung Tae
    • Journal of Embryo Transfer
    • /
    • v.33 no.4
    • /
    • pp.327-336
    • /
    • 2018
  • To date, there are no protocols optimized to the effective separation of spermatogonial stem cells (SSCs) from testicular cells derived from mouse testes, thus hindering studies based on mouse SSCs. In this study, we aimed to determine the most efficient purification method for the isolation of SSCs from mouse testes among previously described techniques. Isolation of SSCs from testicular cells derived from mouse testes was conducted using four different techniques: differential plating (DP), magnetic-activated cell sorting (MACS) post-DP, MACS, and positive and negative selection double MACS. DP was performed for 1, 2, 4, 8, or 16 h, and MACS was performed using EpCAM ($MACS^{EpCAM}$), Thy1 ($MACS^{Thy1}$), or GFR ${\alpha}1$ ($MACS^{GFR{\alpha}1}$) antibodies. The purification efficiency of each method was analyzed by measuring the percentage of cells that stained positively for alkaline phosphatase. DP for 8 h, $MACS^{Thy1}$ post-DP for 8 h, $MACS^{GFR{\alpha}1}$, positive selection double $MACS^{GFR{\alpha}1/EpCAM}$, and negative selection double $MACS^{GFR{\alpha}1/{\alpha}-SMA}$ were identified as the optimal protocols for isolation of SSCs from mouse testicular cells. Comparison of the purification efficiencies of the optimized isolation protocols showed that, numerically, the highest purification efficiency was obtained using $MACS^{GFR{\alpha}1}$. Overall, our results indicate that $MACS^{GFR{\alpha}1}$ is an appropriate purification technique for the isolation of SSCs from mouse testicular cells.

Model-Free Hybrid Fault Detection and Isolation For UAV Inertial Measurement Sensors (무인기 관성측정 센서의 비모델 복합 고장진단기법)

  • Kim, Seung-Keun;Kim, You-Dan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.3
    • /
    • pp.200-206
    • /
    • 2005
  • In this paper, a redundancy management system for aircraft is studied, and FDI (Fault Detection and Isolation) algorithm of inertial sensor system is proposed. UAV system cannot allow triple or quadruple hardware redundancy due to the limitations on space and weight. In the UAV system with dual sensors, it is very difficult to identify the faulty sensor. Also, conventional FDI method cannot isolate multiple faults in a triple redundancy system. In this paper, hardware based FDI technique is proposed, which combines a parity equation approach with the wavelet based technique, which is a model-free FDI method. To verify the effectiveness of the proposed FDI method, numerical simulations are performed.

Parametric Study of Asymmetric Base-Isolation Coupling Control System for Vibration Control of Adjacent Twin Buildings (쌍둥이 인접구조물의 진동 제어를 위한 비대칭 지진격리 연결 제어시스템의 매개변수연구)

  • Kim, David;Park, Wonsuk;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.3
    • /
    • pp.45-51
    • /
    • 2022
  • This paper focuses on a recently proposed asymmetric base-isolation coupling control system (ABiCS) for the vibration control of adjacent twin buildings. The ABiCS consists of inter-story diagonal dampers, a connecting damper between the two buildings, and a seismic isolation device at the base floor of one building. To investigate the control characteristics of ABiCS, a parametric study was performed by numerically simulating the 20-story twin buildings. In the parametric study, the control capacities of the inter-story diagonal dampers, connecting damper, and seismic isolation device were considered as varying parameters. The parametric study results indicate that the connecting damper between the two buildings reduces the responses of both buildings only at optimal or near-optimal capacity. In addition, adjusting the stiffness of the base isolation is found to be the most effective method for improving seismic performance and achieving cost-effectiveness. Accordingly, we presented a scenario-based performance improvement approach in which reducing the stiffness of the base isolation device could be an effective technique to improve the seismic performance of both buildings. However, note that checking the maximum allowable displacement of the base isolation device is essential.

Assessment of a dual isolation system with base and vertical isolation of the upper portion

  • Sasan Babaei;Panam Zarfam;Abdolreza Sarvghad Moghadam;Seyed Mehdi Zahrai
    • Structural Engineering and Mechanics
    • /
    • v.88 no.3
    • /
    • pp.263-271
    • /
    • 2023
  • Base isolation is a widely used technique for the seismic control of structures as it reduces the structural seismic demand. However, displacement of the isolation layer is not economically feasible in congested urban areas. To resolve the issue, an innovative system is proposed here to isolate both horizontally at the base and vertically in the upper portion of the structure. A simplified linear three degree-of-freedom (3DOF) model of the system that considers the mass and stiffness ratios of the substructure has been introduced and analyzed in MATLAB by spectrum analysis. The 3DOF model results revealed that, when the period of the soft substructure reaches 2.5 times that of the stiff substructure, the isolation and the lower substructure responses decrease by 65% and 51%, respectively. Time-history analysis of a MDOF system at three frequency ratios under a wide range of ground motions indicated that, at the expense of accepting a certain large drift by the soft substructure in the upper portion of the structure, base isolation displacement can be decreased by 10%.

An Approach to Isolation of Thromboxane Synthase (TX-SYN) by Ligand Tethered Affinity Techniques

  • Andersen Niels H.;Rhee Jaekeol
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.2
    • /
    • pp.119-122
    • /
    • 1992
  • The affinity chromatographic technique was applied to the isolation of Thromboxane Synthase, with a variety of imidazolyl alkanoic acids coupled Sepharose 2B including a gel (G in Table 4) which has one free COOH group in the bound affinity ligand. The effect of ligand structure on the "affinity" and "selectivity" for thromboxane synthase isolation is described.

A Study on the Manufacturing and Dynamic Charateristics of Vibration Absorber Using Piezoceramics and Isolation Pad (압전세라믹과 방진고무를 이용한 진동흡수장치의 제작과 동적특성 연구)

  • Heo, Seok;Kwak, Moon-k
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.477-482
    • /
    • 2002
  • This research is concerned with the study of an active vibration absorber using piezoelectric actuators and Isolation pad. The active isolation system consists of 4-pairs of PZT actuators bonded on the surface of an aluminum plate and a passive damping material. The active system is connected to the passive system in series. The Signals of the accelerometers are fed into the PZT actuator through the controller. We proposed a new control technique which can deal with the shock as well as the base excitation in this study. The Positive Acceleration Feedback(PAE) tuned to the natural frequency of the vibration isolation system is used to suppress the vibrations caused by the shock using the top accelerometer signal. The Negative Acceleration Feedback (NAF) based on the base acceleration signal is used to counteract the base motion. Experimental results show that the proposed active vibration isolation system can suppress vibrations.

  • PDF

Isolation of Eckol from Ecklonia cava via Centrifugal Partition Chromatography (CPC) and Characterization of it's Anti-inflammatory Activity (고속원심분배 크로마토그래피를 이용한 감태(Ecklonia cava)로부터 Eckol의 분리 및 항염증 활성)

  • Kim, Yoon Taek;Lee, Ji-Hyeok;Ko, Ju-Young;Oh, Jae-Young;Lee, Won-U;Sok, Chang Hyun;Hong, Jin Tae;Jeon, You-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.3
    • /
    • pp.301-307
    • /
    • 2015
  • Phlorotannins and marine algal polyphenols, including dieckol, 6,6-bieckol, phloroglucinol, phlorofucofuroeckol-A, and eckol, were isolated from brown seaweeds. These compounds have beneficial bioactivities, and Ecklonia cava has become widely used for the extraction and isolation of phlorotannins. Eckol, in particular, has been to shown to have antioxidant, anti-inflammatory, anticoagulatory, and photoprotective properties. However, due to its low abundance in weaweed, the isolation and purification of eckol are difficult. Its limited availability renders the isolation and purification of eckol labor-intensive processes. Centrifugal partition chromatography (CPC) is an efficient technique for the isolation and purification of eckol. In this study, eckol was isolated from the ethyl acetate fraction of the 70% ethanol extract of E. cava using CPC with a two-phase solvent system of a n-hexane:EtOAc:methanol:water (2:8:3:7, v/v) solution. The purity and anti-inflammatory activity of the isolated eckol were verified by high-performance liquid chromatography and by assaying lipopolysaccharide-induced inflammatory responses in an immortalized murine BV2 microglial cell line, respectively. In conclusion, CPC is a useful technique for simple and efficient isolation of eckol from E. cava.