• Title/Summary/Keyword: Isokinetic torque

Search Result 145, Processing Time 0.025 seconds

The Change of Isokinetic Trunk Muscle Strength after Reduction of Body Weight (비만치료 전후 체간 근력 변화에 관한 연구)

  • Hong, Seo-Young;Park, Ji-Hyun;Lee, Han-Kil;Kim, Hyun-Soo
    • Journal of Haehwa Medicine
    • /
    • v.18 no.2
    • /
    • pp.13-20
    • /
    • 2009
  • Objectives : In order to investigate change of isokinetic trunk muscle strength according to decrease of body composition analysis parameter after obesity treatment. Methods : 2 obese patients have been treated with oriental medical obese treatment for 1 month. One patient got the exercise treatment, another didn't. Before and after treatment, the segmental bioelectrical impedance analysis, isokinetic trunk muscle strength test were performed. Then we analyzed the relationship of data. Results : After obesity treatment, BMI(Body Mass Index), PBF(Percentage of Body Fat), WHR(Waist Hip Ratio) were decreased in all patient and LBM(Lean Body Mass) was increased. In non-exercise patient, Ext.PT(extension Peak Torque) was decreased and Flex.PT(flexion Peak Torque) was increased. In exercise patient showed the opposite results. E/F ratio became more imbalance. Conclusions: Ext.PT was decreased in non-exercise patient but increased in exercise patient. And the trunk muscle strength became imbalance in both patients, right after the treatment. So trunk muscle exercise should be carried out and it is necessary to do long term study.

  • PDF

Effect on Improvement of Muscle Strength for Loading Pattern using Electric Exercise Instrument (전동식 운동기기의 부하방식에 따른 근력증진 효과)

  • Kang, Seung-Rok;Kim, Kyung;Jeong, Gu-Young;Seo, Young-Bum;Jeong, Jang-Sik;Kim, Jung-Ja;Kwon, Tae-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.2
    • /
    • pp.229-238
    • /
    • 2012
  • This study is to compare muscle strength between isotonic exercise and isotonic & isokinetic exercise. Participants are 12-man and 10-woman whom they are healthy without medical history in shoulder, elbow and lumbar joint. We performed experiment total 4-weeks that exercise 3-days a week each exercise pattern. We measured shoulder, elbow and lumbar joint torque with BIODEX and circumference of muscle in upper arms once a week. The result showed that isotonic & isokinetic exercise pattern significantly more improved joint torque in shoulder, elbow, lumbar than isotonic exercise pattern. Because that isotonic & isokinetic exercise pattern supplied muscle strengthen and caused muscle contraction. This exercise pattern can be used new exercise training method for major athlete and normal people. Also this pattern can be used rehabilitation treatment.

Effect of Wearing a Thermal Compression Sleeve on Isokinetic Strength and Muscle Activity of Wrist Flexors and Extensors

  • Kim, Ki Hong;Jeong, Hwan Jong;Hong, Chan Jeong;Kim, Hyun Sung;Kim, Byung Kwan
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.183-191
    • /
    • 2022
  • The purpose of this study, the wearing conditions of functional pressure clothing applied with the thermotherapy device were determined by three types (NW, CW, TCW) and the difference in isokinetic strength, muscle activity around the forearm was investigated and the effects of products mixed with thermotherapy and pressure treatment were verified. Ten men in their 20s were selected as subjects, and all subjects were randomly assigned three wearing conditions, and wrist flexion/extension exercise was performed at 30° and 90° angular velocity in isokinetic equipment. Peak torque, average power, and EMG were measured during exercise in all conditions. For peak torque, CW was significantly highest at velocity of 30°/sec flexion. Average power showed no significant difference by condition. In the angular velocity of 90°/sec, flexion was significantly higher in CW and TCW than in NW. As a result, wearing clothes with pressure effect and heat effect can show high efficiency in high muscle strength development and fast contraction activity during low speed exercise, and it is thought that it can show improvement of exercise ability through efficient recruitment of motor unit.

Isokinetic Test of the Extensors and Flexors in Total Knee Replacement Patients (슬관절 전치환술 환자의 슬관절 신전근 및 굴곡근에 대한 등속성운동검사)

  • Lee, Keun-Heui;Lee, Hyun-Ok;Lee, In-Sil;Seo, Hyun-Kyu;Kim, Seung-Joon;Bae, Sung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.3
    • /
    • pp.585-596
    • /
    • 2001
  • The twenty one individuals with total knee replacement who were admitted to Kang-Dong Hospital for comprehensive physical therapy were studied in order to demonstrate the effectiveness of an isokinetic test program using the Cybex 6000 machine. The subjects were divided into three groups with the isometric exercise group receiving isometric exercise, the isokinetic eccentric exercise group, and isokinetic concentric exercise group receivind isokinetic exercise(eccentric, concentric) to knee flexors and extensors muscles for a six weeks' period using the Cybex 6000. The results are follow: 1. The extensors were increased significantly at all groups after 6 weeks training(p<.05). The flexors were increased significantly at isokinetic eccentric and isokinetic concentric group but no significantly differences at isometric group(p>.05) 2. At the effect of extensors and flexors after 6 weeks training. higher to 30$^{\circ}$ /sec of isokinetic concentric exercise, lower to 120$^{\circ}$ /sec of isometric exercise. 3. The peak torque was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups. 4. The total work was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups. 5. The ratio of peak torque to body weight were more increased significantly in the flexors and extensors of the isikinetic conccentric exercise among three groups. 6. The average power was more increased significantly in the flexors and extensors of the isikinetic conccentric exercise among three groups. 7. The average R.O.M in the pre-exercise and post-exercise was not different significantly in all three groups. According to the above results, In the muscle strength recovery for total knee replacement patients, isokinetic concentric exercise group was significantly greater than the isokinetic eccentric and isometric exercise groups after a six weeks training.

  • PDF

Comparison of Body Composition, Physical Fitness, Isokinetic Strength between a major in EMT Students and a major in Physical Education Students (응급구조 전공과 체육 전공학생의 신체구성, 체력 및 슬관절 등속성 근기능 비교 연구 - 대전·충남을 중심으로 -)

  • Cho, Byung-Jun;Kim, Hak-Soo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.2
    • /
    • pp.129-136
    • /
    • 2005
  • The purpose of this study was to compare the level of physical fitness and isokinetic strength, between EMT student and physical education students. Nine a major in EMT student volunteers, and nine a major in physical education student volunteers participated in that study as subjects. The basic physical body composition, fitness and isokinetic strength were measured. The data obtained in the study was analyzed by SPSS PC+ for window version 10.0. The difference in the mean of each variable between the two groups was analyzed by using the independent t-test and the significance level for all analysis was set at <.05. The results were as follows ; 1. There was a significant difference in the basic physical fitness between the two groups with the exception flexibility. The difference showed the statistical significance on back strength, balance and power in physical education students. 2. There were significant difference in body composition between the two groups with the exception of lean body fat. The difference showed the statistical significance on body fat%, body fat mass in the physical education students. 3. There was significant defference in the isokinetic strength between the two group. The difference showed the statistical significance on peak torque, peak torque B/W%. It was concluded that the physical education students may not have an effect of flexibility; however, back strength, balance, power, body composition, isokinetic strength, could be enhanced due to the long-term period of training. Based on the findings of this study, the regular participation of regular exercise help the untrained men achieve health-related fitness.

  • PDF

Isikinetic evaluation of the knee flexors and extensors on muscle strength in 100 men and women aged 21 - 68yr (21-68세 남녀 100명의 슬관절 굴근과 신근의 근력에 대한 등속성 평가)

  • Nam, Hyoung-Chun
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.2
    • /
    • pp.967-976
    • /
    • 2001
  • The purpose of the present study was to the investigate the effect of aging in men and women on muscle strength of knee extensor and flexors by using the cybex 6000 isokinetic dynamometer. A total of 100 volunteers participated in this study and were divided into five groups according to their chronological age as follows: 20s, 30s, 40s, 50s, 60s, 10 men and 10 women in each decade respectively. Isokinetic ($60^{\circ}{\cdot}s-l$) knee extensor and flexor peak torque, peak torque to body weight ratio, opposing muscles(flexor/extensor) peak torque ratio, deficit of peak torque between dominant and non-dominant were measured. The results obtained were as follows: 1) In men, While the aged increased. the peak torque of the knee flexor and extensor statistically sig nificant decreased in the dominant and non-dominant side. 2) In women, Statistically significant difference of knee extensor peak torque was found as the aged increased in the dominant and non-dominant side, but significant difference of knee flexor peak torque did not that. 3) In men, No significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the non-dominant side, but statistically significant difference in the peak torque of knee flexor to body weight weight ratio was found as the aged increased in the dominant side. 4) In women. No significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the dominant side, but statistically significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the non-dominant side. 5) In men and women, While the aged increased, statistically significant difference was found the dominant and non-dominant side in the peak torque of knee extensor to body weight ratio. 6) Peak torque of hamstring to quadriceps ratio of dominant and non-dominant side in men and women were not significantly different as the age increases. 7) Mean deficit of peak torque between dominant and non-dominant side in men and women were not significantly different as the age increases. From these results we conclude a proper exercise program is need before 50s decade to preserve in muscle strength of knee flexors and extensors.

  • PDF

Isokinetic Evaluation of the Trunk Flexors and Extensors of Operated Laminectomy & Disectomy Patients (요추간판 수핵탈출중 수술환자의 체간부 굴근 및 신근의 등속성 운동 평가)

  • Choi, Byung-Ok
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.2
    • /
    • pp.951-961
    • /
    • 1996
  • Isokinetic exercise is dynamic, but the spped of movement must be regulated so that the resistance is in ratio to the force applied at each point throughout the full range of motion. The purpose of this study is to comparise with trunk flexors & extensors of isokinetic evaluation of pre-exercise and post-exercise in operated laminectomy & disectomy patients. 7 subjects were examined at $120^{\circ}$/sec and $60^{\circ}$/sec each 15 days. The results were as follows; 1. Peak torque of extensors on $60^{\circ}$/sec showed significant difference statistically(p<0.05), but peak torque of flexors on $60^{\circ}$/sec showed no significant difference statistically. 2. Trunk flexors/extensors ratio of peak torque of $60^{\circ}$/sec showed no significant difference ststistically. 3. Peak torque % B.W of extensors on $60^{\circ}$/sec showed significant difference statistically(p<0.05), but peak torque % B.W of flexors on $60^{\circ}$/sec showed no significant difference statistically. 4. TAE of extensors on $60^{\circ}$/sec showed significant difference statistically (p<0.05), but TAE of flexors on $60^{\circ}$/sec showed no significant difference. 5. Total work of flexors & extensors on $60^{\circ}$/sec showed significant difference statistically (p<0.05). 6. Average power of flexors & extensors on $120^{\circ}$/sec showed significant difference statistically(p<0.05). 7. Endurance ratio of flexors & extensors on $120^{\circ}$/sec showed no significant difference statistically. 8. Set total work of flexors & extensors on $120^{\circ}$/sec showed significant difference statistically(p<0.05). 9. TAE of extensors on $120^{\circ}$/sec showed significant difference statistically(p<0.05), TAE of flexors on $120^{\circ}$/sec showed no significant difference statistically. 10. Total work of flexors & extensors on $120^{\circ}$/sec showed significant difference statistically (p<0.05).

  • PDF

Effects of 3D Compression Pants and Kinesio Taping on Isokinetic Muscular Function of Leg During Knee Joint Flexion Motion (3D 밀착형 팬츠와 키네시오 테이핑이 무릎관절의 등속성 굴곡 운동 시 하지의 근기능에 미치는 영향)

  • Choi, Jiyoung;Park, Heegeun;Lee, Wanglok;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.2
    • /
    • pp.240-257
    • /
    • 2016
  • This study determines the effect of 3D compression pants and Kinesio taping on muscular function of the leg during knee joint flexion and extension. Eight males participated in the experiment, wearing basic pants (BP), Kinesio taping on bare skin (KT), 3D compression pants with (KTP) and without Kinesio taping (CP). The test protocol for isokinetic muscular function was composed of four sets at three angular velocities (60, 180, $240^{\circ}/sec$) using Cybex 660. Peak torque and work per repetition of the lower limbs of eight males were analyzed from the result of Cybex. Agility and power of the subjects were examined from side step and sergeant jump. Peak torque, average power, work per repetition, force decay time of subjects wearing CP and KTP were significantly better than BP or KT, especially at low angular velocity of $60^{\circ}/sec$. The time to generate peak torque of subjects wearing BP was the longest, while the force-decay time of BP was the shortest. The application of Kinesio tape on skin did not increase muscle peak torque, work and power, but did shorten the time to generate peak torque.

Tight sportswear and physiological function - Effect on muscle strength and EMG activity -

  • Dai, Xiao-Qun;Li, Yu-Ping;Cai, Juan-Juan;Lu, A-Ming;Wang, Guo-Dong
    • The Research Journal of the Costume Culture
    • /
    • v.21 no.4
    • /
    • pp.606-611
    • /
    • 2013
  • It has been reported that tight sportswear could have complicated influence on physiological function of human body. The purpose of this present study was to investigate the effect of wearing gradient compression tights (GCT) on muscle strength and EMG activity during repeated isokinetic muscle contractions. Four healthy male undergraduate students performed maximal voluntary isokinetic concentric muscle contractions on biomechanical test and training systems with GCT and loose pants as control (Cont) respectively. During each test, the peak torque of extensor and flexor contractions and the surface electromyography (sEMG) of the rectus femoris and medial gastrocnemius was recorded simultaneously, the peak torque was recorded as an indicator of muscle strength, and the average amplitude and mean power frequency of sEMG were calculated as indicators of EMG activity. The results showed that: the peak torque decreased gradually during continuous muscle contractions both when the Cont and GCT were worn, average sEMG and mean power frequency declined along with the repetitions of muscle contractions for both wearing conditions, and the change tendency was consistence with that of peak torque. There was no obvious difference between the peak torque recorded wearing the Cont or wearing GCT, but when GCT were worn, average sEMG was lower and mean power frequency was higher than the Cont condition. In 24 samples obtained from four subjects, 80% of results showed the same trend. So we could make a conclusion that wearing GCT had no obvious effect on the improvement of muscle strength, but it would affect the EMG activity positivly.

Effects of Resting Periods Between Exercise Sets During Isokinetic Exercise on Muscle Performances and Physiological Variables in Middle-aged Women (중년여성에서 등속성 운동 시 세트간의 휴식시간이 등속성 근기능 및 생리적 변인에 미치는 영향)

  • Choi, Bo-Sung;Han, Sang-Wan
    • Physical Therapy Korea
    • /
    • v.8 no.3
    • /
    • pp.77-95
    • /
    • 2001
  • The purpose of this study was to investigate the effects of resting periods between exercise sets during isokinetic contraction on recovery from muscle fatigue, strength, heart rate, blood pressure, and lactate level. Sixteen women performed 10 repetitions of isokinetic exercise for three sets in three different conditions. During the sets, they rested 50, 100, and 150 seconds in each condition. And the results were: 1) In this population, the peak torque of extensor during the isokinetic exercise in 100 second resting condition was significantly higher than that in 50 and 150 second resting conditions (p<.01). The total work of extensor was significant in the second and third sets in 50 and 100 second resting conditions (p<.01). 2) During the isokinetic exercise, the heart rate was progressively increased as the sets were advanced in all resting conditions (p<.01). And the increase was significant during the second and third sets than the first in 50 second resting condition (p<.01), while it was significantly greater after the third set than the first in 100 and 150 second resting conditions (p<.01). 4) No difference was found between the resting periods in blood lactate level and blood pressure during the isokinetic exercise. However, differences were found between the sets in these variables (p<.01).

  • PDF