• Title/Summary/Keyword: Isokinetic torque

Search Result 145, Processing Time 0.028 seconds

Comparison between Isokinetic Peak Torque and Isotonic 1RM on the Knee Joint

  • Jaehyun Yoo
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.2
    • /
    • pp.201-205
    • /
    • 2023
  • Objective: Resistance exercise is a necessary element to improve quality of life, and measurement and evaluation of muscle strength provide important information for prescription and management of rehabilitation and exercise programs. This study analyzed the correlation between direct and indirect 1RM for isokinetic maximum torque of the knee joint in order to provide useful information in the field of exercise programs. In addition, the flexion-extension ratio and the difference in left-right deviation were verified. Design: A cross-sectional study Methods: The subjects of this study were 33 healthy adult men and women without medical problems who participated in the health exercise class program at S University in Seoul. The correlation between isokinetic maximum torque and direct and indirect 1RM was analyzed, and a dependent t-test was performed to analyze the flexion-extension ratio and left-right deviation. Results: There was a high correlation between the isokinetic maximum torque and direct and indirect 1RM, and no statistically significant difference was shown between the test methods in the analysis of the flexion-extension ratio and left-right deviation. Conclusions: Isokinetic muscle function measuring equipment is expensive, so it is difficult to use it in local exercise rehabilitation and training sites. Through this study, it was found that direct and indirect 1RM isokinetic maximum torque showed a high correlation, and there was no difference in evaluating muscle function such as flexion-extension ratio and left-right deviation. Therefore, it is considered that the muscle function evaluation using 1RM in general field can be usefully utilized.

Evaluation of the Identification method of Joint Mechanical Properties Using Isokinetic Movement (등속운동을 이용한 관절계 역학적 특성치 정량화 방법의 유용성 평가)

  • 이창한;허지운;김철승;엄광문
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1190-1193
    • /
    • 2004
  • The purpose of this study is to evaluate the possibility of identifying joint damping property through commercially available isokinetic ergometer (BIODEX). The proposed method is to estimate the damping torque of the knee joint from the difference between the external joint torque for maintaining isokinetic movement and the gravity torque of the lower leg. The damping torque was estimated at various joint angular velocities, from which the damping property would be derived. Measurement setup was composed of the BIODEX system with an external force sensor and Labview system. Matlab was used in the analysis of the damping property. The experimental result showed that the small variation in angular velocity due to acceleration and deceleration of the crank arm resulted in greater change of inertial torque than the damping torque, so that the estimation of damping property from the isokinetic movement is difficult.

  • PDF

A Study on the Effect of Quadriceps Torque at the Isokinetic Mode in Patients with Hemiplegia and Healthy Subjects (Case-Control Study) (편마비 환자 및 정상인에 있어서 등속성모드로 측정한 대퇴사두근 근력에 관한 연구)

  • Jang, Moon-Heon;Ko, Joo-Yeon
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.4
    • /
    • pp.229-240
    • /
    • 1999
  • I examined the isokinetic knee extension mean torque in 30 patients with hemiplegia and 30 healthy subjects matched by age, sex, height, and weight at knee extension velocities of $30^{\circ},\;60^{\circ},\;90^{\circ}$, and $120^{\circ}$/sec. The purpose of this study is as follows: first, to compare isokinetic data between the involved and uninvolved side of patients and healthy subjects. secondly, to determine whether the relative decreases in knee extension mean torque at velocities greater than $30^{\circ}$/sec were different on the two sides. Mean torque of quadriceps on both sides of patients with hemiplegia was significantly less than the mean torque of muscle of healthy subjects at various speeds. Relative decreases in knee extension mean torque differed between speeds, but not between sides. Torque at speed greater than $30^{\circ}$/sec were correlated significantly with the torque at $30^{\circ}$0/sec. These finding indicated that isokinetic testing can provide objective information about quadriceps muscle performance in hemiplegia, and suggested that hemiplegia may have difficulty in moving forcefully at higher speeds than $30^{\circ}$/sec because they are weak. Therapeutic intervention, therefore, might be most beneficial when they are directed toward helping patients with hemiplegia activate their muscle weakness.

  • PDF

The Effects of Treadmill Aerobic Exercise Training on Isokinetic Muscle Strength in Students with Cerebral Palsy (트레드밀 유산소 운동이 뇌성마비학생의 등속성 근력에 미치는 영향)

  • Kang Soon-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.4
    • /
    • pp.1-10
    • /
    • 2004
  • The purpose of this study was to investigate the effects of treadmill aerobic exercise training on isokinetic muscle strength in students with cerebral palsy. The subjects consisted of 9 female students with cerebral palsy between the ages of 10 to 22. The subjects performed treadmill aerobic exercise training with $0\%$ grade by free speed with three times a week for 20 minutes a session and 12 weeks. Concentric peak torque of knee flexors and knee extensors was measured before training and after training at $30^{\circ}/sec$ and $60^{\circ}/sec$ by isokinetic dynamometer. Paired t-test was used to assess changes in variables of isokinetic muscle strength. The results of analysis are as followings. 1) After training, concentric peak torque of the least affected knee flexors(p<.01) and the most affected knee flexors (p<.01) and concentric peak torque of the least affected knee extensors(p<.01) and the most affected knee extensors(p<.01) at $30^{\circ}/sec$ significantly increased. 2) After training, concentric peak torque of the least affected knee flexors(p<.05) and the most affected knee flexors(p<.01) and concentric peak torque of the least affected knee extensors(p<.05) and the most affected knee extensors(p<.01) at $60^{\circ}/sec$ significantly increased. These findings provide evidence that treadmill aerobic exercise training improves isokinetic muscle strength in students with cerebral palsy.

  • PDF

Application Effects of Various Solidity of Mouth Guard on Torque and Power at Isokinetic Contraction in Shoulder : A Pilot Study (다양한 경도의 마우스가드의 착용이 어깨관절의 등속성 수축 시 토크 및 파워에 미치는 영향 : 예비 실험)

  • Lee, Sang-Yeol
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.4
    • /
    • pp.567-571
    • /
    • 2013
  • PURPOSE: This study find out the effect of torque and power through various solidity of mouth guard on shoulder flexion and extension. METHODS: This study was conducted with healthy adults in their 20s Korean. Cybex system was used to measure the torque and power fo shoulder joint flexion/extension during isokinetic contraction when the various solidity mouth guard was used and no mouth guard was used. RESULT: The results of this study were summarized as follows: relative torque and average power was showed significantly difference between non applying mouth guard and applying hard type mouth guard during shoulder flexion and extension at isokinetic contraction. CONCLUSION: The application of hard type mouth guard was increased torque and power in joint of body. which may be clinically useful.

Isokinetic Effect of the Extensors and Flexors in Total Knee Replacement Patients (슬관절전치환술 환자의 슬관절 신전근 및 굴곡근에 대한 등속성운동 효과)

  • Bae, Sung-Soo;Nam, Kun-Woo;Lee, Keun-Heui
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.1
    • /
    • pp.19-31
    • /
    • 2001
  • The twenty one individuals with total knee replacement who were admitted to Kang-Dong Hospital for comprehensive physical therapy were studied in order to demonstrate the effectiveness of an isokinetic test program using the Cybex 6000 machine. The subjects were divided into three groups with the isometric exercise group receiving isometric exercise. the isokinetic eccentric exercise group, and isokinetic eccentric exorcise group receiving isokinetic exercise(eccentric. concentric) to knee flexors and extensors muscles for a six weeks period using the Cybex 6000. The results were follow :1 . The peak torque was increased significantly in the flexors and extensors of the isokinetic conccentric exorcise among three groups(p<.05). 2. The progress of peak torque was increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups(p<.05). 3. The total work was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups(p<.05). 4. The progress of total work was more increased significantly in the flexors and extensors of the isokinetic conccentric exercise among three groups(p<;.05). 5. The ratio of endurance was not increased significantly in all three groups. 6. The extensors in the peak torque was likely to recover rapidly than the flexors. 7.The average R.O.M in the pre-exercise and post-exercise was not different significantly in all three groups. According to the above results, In the muscle strength recovery for total knee replacement patients, isokinetic concentric exercise group was significantly greater than the isokinetic eccentric and isometric exercise groups after a six weeks training.

  • PDF

The Comparative Study with Isokinetic and Isotonic Exercise Knee Joint Involved Side in Hemiplegia Patients (편마비 환자들의 환측 슬관절 중심으로 등속성 및 등장성 운동 비교연구 -Cybex II+ Isokinetic Dynamometer를 이용한 평가를 기준으로-)

  • Chae, Soo-Sung;Jun, Gun-Sik;Moon, Sung-Ki
    • Journal of Korean Physical Therapy Science
    • /
    • v.1 no.1
    • /
    • pp.165-173
    • /
    • 1994
  • The purpose of this study was to find out the effect of muscular strength of quadriceps, hamstring of knee joint to isokintic, isotonic exercise treatment in stroke. Data was collected from 80 stroke from January 10. 1994 to april 10, 1994 in a Chungnam university hospital. The results were as follows; 1. Peak torque was higher isokinetic than isotonic excercise group both in quadriceps and hamstring of knee joint, 6 weeks, 8 weeks 10 weeks showed statistically significant in isokinetic exercise training group. 2. Total work was high isokinetic than isotonic exercise group both in quadricaps and hamstring of knee joint, 10 weeks 12 weeks showed statistically significant in isokinetic exercise training group. 3. Average peak torque and total work was higher isokinetic than isotonic excercise group both in quadriceps and hamstring of knee joint, showed statistically significant in isokinetic exercise training group (p<0.05).(p<0.01). Isokinetic and isotonic exercise treatment were needed for sutable walk training in stroke. But I think that better method was isokinetic exercise treatment in muscular strength and endurance.

  • PDF

Isokinetic Evaluation of Knee Muscles in Female Youth Group (여자 중학생들의 슬관절 근육의 등속성 운동평가)

  • Han, Ki-Hoon;Kim, Hwan-Soon
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.1-12
    • /
    • 2003
  • This study was performed to provide normative isokinetic strength of knee muscles of middle school non-athletic and athletic populations for rehabilitation and pre-season screening for injury prevention. Seven non-athletic subjects and 8 hockey players participated in this investigation. Each subject was tested at speeds of $60^{\circ}/sec$, $180^{\circ}/sec$, and $300^{\circ}/sec$. The free weight of lower leg was measured at speed of $60^{\circ}/sec$ to take gravity effect Into consideration when peak torque of knee muscles occurred. The results showed that the relative peak torque production of knee flexors did not change but the relative peak torque of knee extensors decreased significantly. Mamstring/quadriceps ratios increased mainly due to significant decreases in knee extensors torque production. No significant differences were found between groups. The hamstring/quadriceps ratios for both groups were significantly lower when the gravity effect was not eliminated.

Evaluation of Plantarflexion Torque of the Ankle-Foot Orthosis Using the Artificial Pneumatic Muscle (인공공압근육 엑츄에이터를 이용한 족관절 보조기의 족저굴곡 토크 평가)

  • Kim, Kyung;Kwon, Tae-Kyu;Kang, Seung-Rok;Piao, Yong-Jun;Jeong, Gu-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.6
    • /
    • pp.82-89
    • /
    • 2010
  • Ankle-foot orthosis with an artificial pneumatic muscle which is intended for the assistance of plantarfelxion torque was developed. In this study, power pattern of the device in the various pneumatics and the effectiveness of the system were investigated. The pneumatic power was provided by ankle-foot orthosis controlled by user‘s physiological signal, that is, muscular stiffness in soleus muscle. This pneumatic power can assist plantarflexion torque of ankle joint. The subjects performed maximal voluntary isokinetic plantarflexion motion on a biodexdynamometer in different pneumatics, and they completed three conditions: 1) without wearing the orthosis, 2) wearing the orthosis with artificial muscles turned off, 3) wearing the orthosis activated under muscular stiffness control. Through these experiments, we confirmed the effectiveness of the orthosis and muscular stiffness control using the analyzing isokinetic plantarflexion torque. The experimental results showed that isokinetic torques of plantarflexion motion of the ankle joints gradually increased in incremental pneumatic. The effectiveness of the orthosis was -7.26% and the effectiveness of the muscular stiffness control was 17.83% in normalized isokinetic plantarflexion torque. Subjects generated the less isokinetic torques of the ankle joints in wearing the orthosis with artificial muscles turned off, but isokinetic torques were appropriately reinforced in condition of wearing the orthosis activated under muscular stiffness control(17.83%) compared to wearing the orthosis(-7.26%). Therefore, we respect that developed powered orthosis is applied in the elderly that has weak muscular power as the rehabilitation equipment.

Effects of Static, Dynamic, PNF Stretching on the Isokinetic Peak Torque

  • Lim, Chang-Hun
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.6
    • /
    • pp.37-42
    • /
    • 2011
  • Purpose: The aim of this study is to suggest the basic materials for proposing effective and efficient methods when stretching by measuring isokinetic muscular strength according to static, dynamic and PNF stretching. Methods: This study was conducted on 45 healthy persons (male and female) in their twenties who are attending universities. The subjects are randomly divided into three (3) groups, and static stretching is applied in group 1, dynamic stretching is applied in group 2 and PNF stretching is applied in group 3. After carrying out static, dynamic and PNF stretching, peak torque was measured using isokinetic muscular strength measurement. Results: According to the results, at $60^{\circ}$/sec and $180^{\circ}$/sec isokinetic peak torque of the knee joint according to types of stretching, the largest changes were shown in Group 2 extension and flexion, and the least changes were shown in Group 1. There were significant differences among the three groups (p<0.05), and the result of after-analysis by LSD showed that there were significant differences between Groups 1 and 2, and Groups 1 and 3 (p<0.05). Conclusion: The intention of this study was to determine the peak torque using Cybex after applying three stretching methods to hamstring muscles, and the case of dynamic and PNF stretching was found to be more significant in both the $60^{\circ}$/sec and $180^{\circ}$/sec angular speeds than that of static stretching. Using the results of such studies, if dynamic and PNF stretching are applied together with warming-up before performing sports, the risk of suffering wounds would reduce and the exactness of sports would increase.