• Title/Summary/Keyword: Isodose curve

Search Result 51, Processing Time 0.031 seconds

Research of 6 MeV Electron Dose Distribution (6 MeV Electron Therapy에서의 Electron Dose Distribution에 관한 연구)

  • Je Jae-Yong;Park Chul-Woo;Jin Sung-Jin;Park Eun-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.161-166
    • /
    • 2005
  • Purpose : Electron is used for the treatment of skin cancer, breast cancer, and head and neck cancer in clinic. Our study is performed to check the isodose distribution in source surface distance(SSD)and source bolus distance(SBD)setup, nipple influence to isodose distribution of electron, junctional area isodose variation of photon and electron field. Materials and Methods : The electron dose distribution measures the diameter for 20 cm hemisphere paraffin phantom 2 made. It inserted the film between 2 paraffin phantom and it investigated it got radiation and dose distribution curve. Results : The 8% of isodose difference is with the surface distance(SSD)and source bolus distance(SBD)setup. The electon when the nipple exists inside the field, as nipple size it cuts the bolus and when it puts out and there is a possibility of getting the dose distribution which is homogeneous. When in the junction of electron and photon it uses the bolus it uses in the electron field whole, there is a possibility of getting the dose distribution which is homogeneous. Conclusion : The dose distribution decrease from the SBD setup. To reduce the influence of nipple, corresponding volume of bolus should be removed. And bolus covering all the electron field reduced hot and cold spot of junctional area of photon. In the future becomes the research which sees an effective electron therapy.

  • PDF

Study on the Dose Calculation for Iridium and Cessium Sources (이리듐과 세슘의 혼합선원을 이용한 강내치료의 선량계획에 관한 연구)

  • Kang, Jeong-Ku;Kim, Soo-Kon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.42-46
    • /
    • 2005
  • The Dose calculation program for the Buchler remote after-loading system was developed. We use iridium source for the tandem and cessium for the ovoids. We determined the source length and distributions by dividing the program disk to 72 points. The dose rate for the each program disk were calculated and stored to the tables for the xy coordinates. The dose rate for the interesting points for the patients were calculated by using these tables. We also made isodose curve from the calculations. By using the program, we could calculate the dose rate for the various points of the patient quickly and accurately.

  • PDF

The Study on Scattered Ray by C-arm in Operation Room (수술실 내 C-arm 장치의 산란선 분포에 대한 연구)

  • Park, Seung-Hyun;Park, Joo-Mi;Kim, Hyun-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.21-26
    • /
    • 2011
  • A radiation imaging system used in a surgery room is mainly using C-arm which is purposed to fluoroscope. C-arm is often use to watch an operation's accuracy and progress, but not only being bombed to this first beam but also affected to this scattered beam, so now we are look for the way to reduce bombed amount of doctor, nurses and radiological technologists. We measured the exposure dose in $0^{\circ}$ spot according to the distance to find out frequency distribution of scattered ray in an operation room and found the spot which has the same exposure dose from $30^{\circ}$ distance of all directions and wrote isodose curve. We analyzed the data and found out the sudden reduction of scattered ray according to the long direction also found out that scattered ray was not related to the directions. Operators must recognize the reduction of exposure dose. Because reducing scattered ray from all directions in an operation room is really difficult. So every operators must use shelters to reduce the exposure dose and notice the safety.

  • PDF

The Dose Distribution of Arc therapy for High Energy Electron (고에너지 전자선 진자조사에 의한 선량분포)

  • Chu, S.S.;Kim, G.E.;Suh, C.O.;Park, C.Y.
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.29-36
    • /
    • 1983
  • The treatment of tumors along curved surfaces with stationary electron beams using cone collimation may lead to non-uniform dose distributions due to a varying air gap between the cone surface and patient. For large tumors, more than one port may have to be used in irradiation of the chest wall, often leading to regions of high or low dose at the junction of the adjacent ports. Electron-beam arc therapy may elimination many of these fixed port problems. When treating breast tumors with electrons, the energy of the internal mammary port is usually higher than that of the chest wall port. Bolus is used to increase the skin dose or limit the range of the electrons. We invertiaged the effect of various arc beam parameters in the isodose distributions, and combined into a single arc port for adjacent fixed ports of different electron beam eneries. The higher fixed port energy would be used as the arc beam energy while the beam penetration in the lower energy region would be controlled by a proper thickness of bolus. We obtained the results of following: 1. It is more uniform dose distribution of electron to use rotation than stationary irradiation. 2. Increasing isocenter depth on arc irradiation, increased depth of maximum dose, reduction in surface dose and an increasing penetration of the linear portion of the curve. 3. The deeper penetration of the depth dose curve and higher X-ray background for the smaller field sized. 4. If the isocenter depth increase, the field effect is small. 5. The decreasing arc beam penetration with decreasing isocenter depth and the isocenter depth effect appears at a greater depth as the energy increases. 6. The addition of bolus produces a shift in the penetration that is the same for all depths leaving the shape of the curves unchanged. 7. Lead strips 5 mm thick were placed at both ends of the arc to produce a rapid dose drop-off.

  • PDF

Bragg-curve simulation of carbon-ion beams for particle-therapy applications: A study with the GEANT4 toolkit

  • Hamad, Morad Kh.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2767-2773
    • /
    • 2021
  • We used the GEANT4 Monte Carlo MC Toolkit to simulate carbon ion beams incident on water, tissue, and bone, taking into account nuclear fragmentation reactions. Upon increasing the energy of the primary beam, the position of the Bragg-Peak transfers to a location deeper inside the phantom. For different materials, the peak is located at a shallower depth along the beam direction and becomes sharper with increasing electron density NZ. Subsequently, the generated depth dose of the Bragg curve is then benchmarked with experimental data from GSI in Germany. The results exhibit a reasonable correlation with GSI experimental data with an accuracy of between 0.02 and 0.08 cm, thus establishing the basis to adopt MC in heavy-ion treatment planning. The Kolmogorov-Smirnov K-S test further ascertained from a statistical point of view that the simulation data matched the experimentally measured data very well. The two-dimensional isodose contours at the entrance were compared to those around the peak position and in the tail region beyond the peak, showing that bone produces more dose, in comparison to both water and tissue, due to secondary doses. In the water, the results show that the maximum energy deposited per fragment is mainly attributed to secondary carbon ions, followed by secondary boron and beryllium. Furthermore, the number of protons produced is the highest, thus making the maximum contribution to the total dose deposition in the tail region. Finally, the associated spectra of neutrons and photons were analyzed. The mean neutron energy value was found to be 16.29 MeV, and 1.03 MeV for the secondary gamma. However, the neutron dose was found to be negligible as compared to the total dose due to their longer range.

Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy (방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구)

  • Na, Soo-Kyung
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF

The Measurement of Ho-166 Absorbed Dose for the Endovascular Irradiation with a Balloon Angio Catheter Using a GafChromic Film (GafChromic 필름을 이용한 Ho-166 의 혈관내 방사선조사를 위한 선량분포 측정)

  • 강해진;조철우;박찬희;오영택;전미선;김영미;박경배
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.151-157
    • /
    • 1999
  • The GafChromic film was used for the dosimetry of a balloon angio catheter filled with the radioisotope HO-166 for endovascular irradiation. The balloon angio catheter was 2 cm long and 3 mm in diameter when inflated. The isotope, Ho-166, was produced by the neutron bombardment using the research reactor in Korea Atomic Energy Research Insititute. Co-60 teletherapy beam was used for making H-D curve for the Gaf-Chromic film. The film dosimetry was measured with a videodensitometer. The radial dose distribution indicated that the absorbed dose dropped to about 20% of the surface dose at the 1 mm away from the balloon surface and at 5 mm position the dose decreased to below 1% of the surface dose. The result also shows that with the specific activity of Ho-l66, 250 mCi/ml it takes 230 seconds to deliver 1200 cGy to the region where is 1mm away from the balloon surface. The concentric isodose curves were also presented. The Ho-166 is an another alternative for endovascualr irradiation to prevent restenosis after PTCA (Percutaneous Trans Coronary Angioplasty)

  • PDF

Comparison of CT based-CTV plan and CT based-ICRU38 plan in Brachytherapy Planning of Uterine Cervix Cancer (자궁경부암 강내조사 시 CT를 이용한 CTV에 근거한 치료계획과 ICRU 38에 근거한 치료계획의 비교)

  • Cho, Jung-Ken;Han, Tae-Jong
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • Purpose : In spite of recent remarkable improvement of diagnostic imaging modalities such as CT, MRI, and PET and radiation therapy planing systems, ICR plan of uterine cervix cancer, based on recommendation of ICRU38(2D film-based) such as Point A, is still used widely. A 3-dimensional ICR plan based on CT image provides dose-volume histogram(DVH) information of the tumor and normal tissue. In this study, we compared tumor-dose, rectal-dose and bladder-dose through an analysis of DVH between CTV plan and ICRU38 plan based on CT image. Method and Material : We analyzed 11 patients with a cervix cancer who received the ICR of Ir-192 HDR. After 40Gy of external beam radiation therapy, ICR plan was established using PLATO(Nucletron) v.14.2 planing system. CT scan was done to all the patients using CT-simulator(Ultra Z, Philips). We contoured CTV, rectum and bladder on the CT image and established CTV plan which delivers the 100% dose to CTV and ICRU plan which delivers the 100% dose to the point A. Result : The volume$(average{\pm}SD)$ of CTV, rectum and bladder in all of 11 patients is $21.8{\pm}6.6cm^3,\;60.9{\pm}25.0cm^3,\;111.6{\pm}40.1cm^3$ respectively. The volume covered by 100% isodose curve is $126.7{\pm}18.9cm^3$ in ICRU plan and $98.2{\pm}74.5cm^3$ in CTV plan(p=0.0001), respectively. In (On) ICRU planning, $22.0cm^3$ of CTV volume was not covered by 100% isodose curve in one patient whose residual tumor size is greater than 4cm, while more than 100% dose was irradiated unnecessarily to the normal organ of $62.2{\pm}4.8cm^3$ other than the tumor in the remaining 10 patients with a residual tumor less than 4cm in size. Bladder dose recommended by ICRU 38 was $90.1{\pm}21.3%$ and $68.7{\pm}26.6%$ in ICRU plan and in CTV plan respectively(p=0.001) while rectal dose recommended by ICRU 38 was $86.4{\pm}18.3%$ and $76.9{\pm}15.6%$ in ICRU plan and in CTV plan, respectively(p=0.08). Bladder and rectum maximum dose was $137.2{\pm}50.1%,\;101.1{\pm}41.8%$ in ICRU plan and $107.6{\pm}47.9%,\;86.9{\pm}30.8%$ in CTV plan, respectively. Therefore, the radiation dose to normal organ was lower in CTV plan than in ICRU plan. But the normal tissue dose was remarkably higher than a recommended dose in CTV plan in one patient whose residual tumor size was greater than 4cm. The volume of rectum receiving more than 80% isodose (V80rec) was $1.8{\pm}2.4cm^3$ in ICRU plan and $0.7{\pm}1.0cm^3$ in CTV plan(p=0.02). The volume of bladder receiving more than 80% isodose(V80bla) was $12.2{\pm}8.9cm^3$ in ICRU plan and $3.5{\pm}4.1cm^3$ in CTV plan(p=0.005). According to these parameters, CTV plan could also save more normal tissue compared to ICRU38 plan. Conclusion : An unnecessary excessive radiation dose is irradiated to normal tissues within 100% isodose area in the traditional ICRU plan in case of a small size of cervix cancer, but if we use CTV plan based on CT image, the normal tissue dose could be reduced remarkably without a compromise of tumor dose. However, in a large tumor case, we need more research on an effective 3D-planing to reduce the normal tissue dose.

Interstitial Vaginal Needle Implantation in Gynecological Tumors : Design and Construction of Applicator (부인과암에서 조직내 삽입 방사선치료 - Applicator의 고안 및 제작-)

  • Kang, Seung-Hee;Chun, Mi-Son;Kang, Hae-Jin;Jung, Chil;Son, Jeong-Hyae
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.167-175
    • /
    • 1998
  • Purpose : It is not a simple task to achieve the ideal isodose curve with a standard vaginal applicator or sing1e plane needle impant in the paravaginal tissue when primary or recurrent gynecological neoplasms(cervical cancers, vaginal cancers and vulvar cancers) are treated as a boost following external beam radiotherapy. The authors introduce the development and construction of a simple, inexpensive, customized applicator for volume implant to maximize the radiation dose to the tumor while minimizing the dose to the rectum and the bladder. Materials and Methods : Nine patients underwent Ir-192 transperineal interstitial implantation for either recurrent(5 cases) or primary(3 cases) cervical cancers or primary vaginal cancer(1 case) between August 1994 and February 1998 at Ajou university hospital. First 3 cases were performed with a sing1e plane implant guided by digital palpation. Because of inadequate isodose coverage in the tumor volume in first 3 cases, we designed and constructed interstitial vaginal applicator for volume implant to improve tumor dose distribution and homogeneity while sparing the surrounding normal tissue. Our applicators consist of vaginal obturator and perineal template that made of the clear acrylamide and dental mold material$(Provil^{(R)})$. The applicators were customized individually according to the tumor size and its location Both HDR and LDR irradiation were given with these applicators accomodating 6 Fr needles(Microselectron Nucletron). The pretreatment planning prior to actual implant was performed whenever possible. Results : Needles can be inserted easily and evenly into the tumor volume through the holes of templates, requiring less efforts and time for the implant procedure. Our applicators made of materials available from commercial vendors. These have an advantage that require easy procedure, and spend relatively short time to construct. Also it was possible to fabricate applicators to individualize according to the tumor size and its location and to achieve the ideal isodose coverage. We found an accurate needle arrangement and ideal dose distribution through the CT scan that was obtained in 3 cases after needle implant. Three patients with primary cervical and vaginal cancers were controlled locally at final follow up. But all recurrent cases failed to do so. Conclusion : The authors introduce inexpensive, simple interstitial vaginal templates which were self-designed and constructed using materials available from commercial vendors such as acrylanide and dental mold material $(Provil^{(R)})$.

  • PDF

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.