Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

Postoperative Radiotherapy in the Rectal Cancers Patterns of Care Study for the Years of $1998\~1999$ (직장암의 방사선치료에 대한 Patterns of Care Study: $1998{\sim}1999$년도 수술 후 방사선치료 환자들의 특성 및 치료내용에 대한 분석결과)

  • Kim, Jong-Hoon;Oh, Do-Hoon;Kang, Ki-Moon;Kim, Woo-Cheol;Kim, Won-Dong;Kim, Jung, Soo;Kim, June-Sang;Kim, Jin-Hee;Kil, Hak-Jae;Suh, Chang-Ok;Sohn, Seung-Chang;Ahn, Yong-Chan;Yang, Dae-Sik
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.22-31
    • /
    • 2005
  • Purpose : To conduct a nationwide survey on the principals in radiotherapy for rectal cancer, and produce a database of Korean Patterns of Care Study. Materials and Methods : We developed web-based Patterns of Care Study system and a national survey was conducted using random sampling based on power allocation methods. Eligible patients were who had postoperative radiotherapy for rectal cancer without gross residual tumor after surgical resection and without previous history of other cancer and radiotherapy to pelvis. Data of patients were Inputted to the web based PCS system by each investigators in 19 institutions. Results : Informations on 309 patients with rectal cancer who received radiotherapy between 1998 and 1999 were collected. Male to female ratio was 59 : 41, and the most common location of tumor was lower rectum ($46\%$). Preoperative CEA was checked in $79\%$ of cases and its value was higher than 6 ng/ml in $32\%$. Pathologic stage were I in $1.5\%$, II in $32\%$, III in $53\%$, and IV in $1.6\%$. Low anterior resection was the most common type of surgery and complete resection was peformed in $95\%$ of cases. Distal resection margin was less than 2 cm in $30\%$, and number of lymph node dissected was less than 12 in $31\%$. Chemotherapy was peformed in $91\%$ and most common regimen was 5-FU and leucovorine ($59\%$). The most common type of field arrangement used for the initial pelvic field was the four field box (Posterior-Right-Left) technique ($65.0\%$), and there was no AP-PA parallel opposing field used. Patient position was prone in $81.2\%$, and the boost field was used in $61.8\%$. To displace bowel outward, pressure modulating devices or bladder filling was used in $40.1\%$. Radiation dose was prescribed to isocenter in $45.3\%$ and to isodose line in 123 cases ($39.8\%$). Percent delivered dose over $90\%$ was achieved in $92.9\%$. Conclusion : We could find the Patterns of Care for the radiotherapy in Korean rectal cancer patients was similar to that of US national survey. The type of surgery and the regimen of chemotherapy were variable according to institutions and the variations of radiation dose and field arrangement were within acceptable range.

The Study on Properties and Application of Enhanced Dynamic Wedge Factor (향상된 동적쐐기인자(Enhanced Dynamic Wedge Factor)의 특성 및 적용에 관한 고찰)

  • Kim, Dae-Sup;Ban, Tae-Joon;Yeom, Mi-Suk;Yoo, Soon-Mi;Lee, Woo-Seok;Back, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.53-60
    • /
    • 2010
  • Purpose: We try to calculate EDW-factor easily with the formula applies essential data of EDW-factor and evaluate the validity through a measurement. Materials and Methods: We used the given value of GSTT (Golden Segmented Treatment Table) for the calculation of the EDW-factor. As to the experimental device, 0.6 cc farmer-type ion-chamber, an electrometer and water- phantom were used. A measurement was made at the maximum dose depth of the photon beam energy 6 MV and 15 MV under the condition that SSD (Source to Surface Distance) was 100 cm. The angle of the EDW (Enhanced Dynamic Wedge) which we use in an experiment was 60 degree, 30 degree, 20 degree in the Y1-OUT direction. We used Eclipse planning system (Varian, USA) as RTP system and the EDW-factor was calculated about all fields and EDW direction. In order to show the EDW-factor feature, a measurement was made at the selected field that verify the influence of the dependability about X, Y jaw and off-axis field. Results: When we change the Y1 field, it influence on the EDW-Factor and measured value. But the error between measured values and calculated values was less than 1%. The experimental result indicated the tendency that the error of the result of calculation and measured value becomes smaller as the EDW angle become smaller whether the calculation point (measurement point) and iso-center are same or not. The influence of the field size and energy did not show up. We simulated with the same condition using the RTP system. And we found that it makes no difference between the MU which is calculated manually by applying the EDW-Factor obtained from the commercial program and the value which is calculated by using RTP system. Conclusion: We excluded fitting value from well-known EDW-Factor formula and calculated EDW-factor with the formula applies essential data of EDW-factor only. As a result, there are no significant difference between the measured value and calculated value and it showed errors less than 1%. Also, we implemented the commercial program to calculate EDW-Factor conveniently without measure a factor on each field.

  • PDF

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

Evaluation of Set-up Accuracy for Frame-based and Frameless Lung Stereotactic Body Radiation Therapy (폐암 정위체부방사선치료 시 고정기구(frame) 사용 유무에 따른 셋업 정확성 평가)

  • Ji, Yunseo;Chang, Kyung Hwan;Cho, Byungchul;Kwak, Jungwon;Song, Si Yeol;Choi, Eun Kyung;Lee, Sang-wook
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.286-293
    • /
    • 2015
  • The purpose of this study was to evaluate the set up accuracy using stereotactic body frame and frameless immobilizer for lung stereotactic body radiation therapy (SBRT). For total 40 lung cancer patients treated by SBRT, 20 patients using stereotactic body frame and other 20 patients using frameless immobilizer were separately enrolled in each group. The setup errors of each group depending on the immobilization methods were compared and analyzed. All patients received the dose of 48~60 Gy for 4 or 5 fractions. Before each treatment, a patient was first localized to the treatment isocenter using room lasers, and further aligned with a series of image guidance procedures; orthogonal kV radiographs, cone-beam CT, orthogonal fluoroscopy. The couch shifts during these procedures were recorded and analyzed for systematic and random errors of each group. Student t-test was performed to evaluate significant difference depending on the immobilization methods. The setup reproducibility was further analyzed using F-test with the random errors excluding the systematic setup errors. In addition, the ITV-PTV margin for each group was calculated. The setup errors for SBF were $0.05{\pm}0.25cm$ in vertical direction, $0.20{\pm}0.38cm$ in longitudinal direction, and $0.02{\pm}0.30cm$ in lateral direction, respectively. However the setup errors for frameless immobilizer showed a significant increase of $-0.24{\pm}0.25cm$ in vertical direction while similar results of $0.06{\pm}0.34cm$, $-0.02{\pm}0.25cm$ in longitudinal and lateral directions. ITV-PTV margins for SBF were 0.67 cm (vertical), 0.99 cm (longitudinal), and 0.83 cm (lateral), respectively. On the other hand, ITV-PTV margins for Frameless immobilizer were 0.75 cm (vertical), 0.96 cm (longitudinal), and 0.72 cm (lateral), indicating less than 1 mm difference for all directions. In conclusion, stereotactic body frame improves reproducibility of patient setup, resulted in 0.1~0.2 cm in both vertical and longitudinal directions. However the improvements are not substantial in clinic considering the effort and time consumption required for SBF setup.

Outcome of LINAC Radiosurgery for a Cavernous Angioma (해면상혈관종에 대한 선형가속기를 이용한 고선량 정위 방사선수술의 임상경험)

  • Hong Semie;Chie Eui Kyu;Park Suk Won;Kim Il Han;Ha Sung Hwan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.107-111
    • /
    • 2003
  • Purpose: To establish the role of stereoactic radiosurgery using a linear accelerator for the treatment of patients with cavernous angloma. Materials and Methods: Between February 1995 and May 1997, 11 patients with cavernous angioma were treated with stereotactic radiosurgery using a linear accelerator. Diagnoses were based on the magnetic resonance imaging in 8 patients, and the histological in 3. The vascular lesions were located on the brainstem (5 cases), cerebellum (2 cases) thalamus (1 case) and cerebrum (3 cases). The clinical presentation at onset included previous intracerebral hemorrhages (9 cases) and seizures (2 cases). All patients were treated with a a linac-based radiosurgery. The median dose of radiation delivered was 16 Gy ranging from 14 to 24 Gy, which was typically proscribed to the 80$\%$ isodose surface (range 50 $\~$ 80$\%$), corresponding to the periphery of the lesion with a single isocenter. Ten patients were followed-up. Results: The median follow-up was 49 months ranging from 8 to 73 months, during which time two patients developed an intracerebral hemorrhage, 1 at 8 months, with the other at 64 months post radiosurgery. One patient developed neurological deficit after radiosurgery, and two developed an edema on the T2 weighted images of the MRI surrounding the radiosurgical target. Conclusion: The use of stereotactic radiosurgery in the treatment of a cavernous angioma may be effective in the prevention of rebleedlng, and can be safely delivered. However, a longer follow-up period will be required.